Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-878445

RESUMEN

OBJECTIVES@#This study aims to evaluate the short-term clinical outcomes and patient satisfaction of anterior and pterygoid implants in the rehabilitation of edentulous maxilla with posterior atrophy.@*METHODS@#Given a minimum follow-up of 1 year, 25 patients with fixed maxillary rehabilitation over anterior and pterygoid implants were enrolled in this retrospective study. The implant survival rates, peri-implant soft tissue status (including probing depth, modified sulcus bleeding index, and plaque index), marginal bone loss, and patient satisfaction were measured.@*RESULTS@#The survival rates for anterior and pterygoid implants at 1-year follow-up were 96.5% and 97.8%, respectively (@*CONCLUSIONS@#For the edentulous maxilla with posterior atrophy, full-arch fixed prostheses supported by anterior and pterygoid implants has an acceptable short-term clinical outcome and excellent patient satisfaction. It may be considered as a predictable and feasible method for maxillary rehabilitation.


Asunto(s)
Humanos , Atrofia/patología , Implantación Dental Endoósea , Implantes Dentales , Prótesis Dental de Soporte Implantado , Estudios de Seguimiento , Arcada Edéntula/cirugía , Maxilar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
2.
Artículo en Chino | WPRIM | ID: wpr-246093

RESUMEN

In the study, the inhibitory effect of epigallocatechin gallate (EGCG) on Calcium oxalate nephrolithiasis and its possible mechanism were investigated. The rat Calcium oxalate nephrolithiasis model was induced through the combined oral administration of ethylene glycol and ammonium chloride, which was intervened with EGCG. Rat blood samples were collected to detect blood creatinine (Cr), blood urea nitrogen (BUN) and blood calcium. Rat urine samples were collected to observe and compare 24-hour urine volume, oxalic acid (Ox) and calcium in urine. Renal samples were collected to prepare tissue slices and observe the pathological changes in Calcium oxalate nephrolithiasis. The expression of osteopontin (OPN) in renal tissues was evaluated by Real-time PCR and Western blot. According to the results, compared with normal rats, rats in the nephrolithiasis model showed significant increases in Cr, BUN, urine Calcium, urine Ox and renal OPN expression (P < 0.05), but obvious decrease in 24-hour urine volume (P < 0.05); Compared with rats with nephrolithiasis, those processed with EGCG revealed remarkable declines in Cr, BUN, urine Calcium and urine Ox (P < 0.05), with significant rise in 24-hour urine volume (P < 0.05) in a concentration-dependent manner. Additionally, compared with the control group, nephrolithiasis rats showed significant pathological changes in Calcium oxalate calculus. After ECCG treatment, the renal pathological changes and OPN expression attenuated significantly in a concentration-dependent manner. The results showed that EGCG inhibits the formation of calcium oxalate nephrolithiasis in rats and shows a notable protective effect on renal functions.


Asunto(s)
Animales , Humanos , Masculino , Ratas , Nitrógeno de la Urea Sanguínea , Calcio , Sangre , Oxalato de Calcio , Metabolismo , Catequina , Creatinina , Sangre , Modelos Animales de Enfermedad , Riñón , Metabolismo , Nefrolitiasis , Sangre , Quimioterapia , Genética , Osteopontina , Genética , Metabolismo , Ratas Wistar
3.
Artículo en Inglés | WPRIM | ID: wpr-269638

RESUMEN

The objective of this study was to investigate the mechanical characteristics of implant-abutment interface design in a dental , using nonlinear finite element analysis (FEA) method. This finite element simulation study was applied on three commonly used commercial dental implant systems: model I, the reduced-diameter 3i implant system (West Palm Beach, FL, USA) with a hex and a 12-point double internal hexagonal connection; model II, the Semados implant system (Bego, Bremen, Germany) with combination of a conical (450 taper) and internal hexagonal connection; and model III, the Brinemark implant system (Nobel Biocare, Gothenburg,Sweden) with external hexagonal connection. In simulation, a force of 170 N with 45" oblique to the longitudinal axis of the implant was loaded to the top surface of the abutment. It has been found from the strength and stiffness analysis that the 3i implant system has the lowest maximum von Mises stress, principal stress and displacement while the Br Bnemark implant system has the highest. It was concluded from our preliminary study using nonlinear FEA that the reduced-diameter 3i implant system with a hex and a 12-point double internal hexagonal connection had a better stress distribution, and produced a smaller displacement than the other two implant systems.


Asunto(s)
Humanos , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Implante Dental-Pilar , Diseño de Prótesis Dental , Análisis del Estrés Dental , Métodos , Análisis de Elementos Finitos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA