China Medical Equipment ; (12): 143-149, 2023.
Artículo en Chino | WPRIM | ID: wpr-1026420

RESUMEN

Objective:To explore the configuration conditions and type-selections of positron emission tomography/computed tomography(PET/CT)and positron emission tomography/magnetic resonance(PET/MR)system under the national new policies during the 14th Five-Year Plan period,so as to provide references for configuration and type-selection of PET/CT and PET/MR equipment of medical institutions.Methods:According to the management polices of relevant configurations of PET/CT and PET/MR,which included configuration licensing,use management and configuration plan,and which were issued by China 14th Five-Year Plan,as well as the development trend and characteristics of PET/CT and PET/MR new techniques,the configuration conditions and type-selection plan of PET/CT and PET/MR equipment were analyzed.Results:Under the new polices during national 14th Five-Year Plan,medical institutions should configure PET/CT and PET/MR depended on the condition of institutions,personnel condition,work basis,the supporting facilities and other conditions,and should select the type of PET/CT and PET/MR which can meet the requirements of medical institutions depended on the technique parameters and performance indicators of PET/CT and PET/MR.Conclusions:Since the 14th Five-Year Plan,there were significant changes in the new policies related to the configurations of PET/CT and PET/MR compared to previous policies.The medical institutions should apply configurations and use PET/CT and PET/MR as new requirement,and configure the PET/CT and PET/MR equipment and conduct type-selection of them as various requirements of each institution.

2.
China Medical Equipment ; (12): 36-39, 2018.
Artículo en Chino | WPRIM | ID: wpr-706516

RESUMEN

Objective: To explore the diagnostic dosage of enhanced computed tomography (CT) of chest and its influence factor through analyzed the data of radiation dosage of enhanced CT of chest. Methods: The scanning data of 297 patients who were implemented scan on 4 different CT devices were compared by using retrospective analysis. And they were divided into A, B, C and D group as different device. The differences of scan sequence among different devices were compared, and volume computed tomography dose index(CTDIvol), dose length product(DLP) and effective dose(ED) were recorded and analyzed. Results: The CTDIvols of 4 groups were (12.18±4.13), (8.86±3.18), (10.70±5.18) and 13.59mGy, respectively, and the differences among them were significant (F=38.58, P<0.05). And the DLPs of the 4 groups were (433.54±145.18), (311.62±112.75), (368.04±181.22) and (475.75±34.25)mGy·cm, and the differences among these groups were significant (F=36.33, P<0.05). Besides, the EDs of the 4 groups were (6.07±2.03), (4.36±1.58), (5.15±2.54) and (6.66±0.48) mSv, and the differences among these groups also were significant (F=36.32, P<0.05). And the comparison between any two means of radiation dosage were significant. Conclusion: The exposure dose of patients who received enhanced CT of chest was correlative with the type of CT device and acquisition parameters. And the effective dosage of patients under automatic tube current module was lower than that of fixed tube current module. And the modulation technique of current of ray tube as angle can efficiently reduce the effective dose. In clinical practice, patients' radiation dosage can be reduced by optimizing the scanning parameters.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA