Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Practical Radiology ; (12): 2030-2033, 2023.
Artículo en Chino | WPRIM | ID: wpr-1020136

RESUMEN

Objective To study the efficacy and safety of bronchial artery embolization(BAE)with tris-acryl gelatin microspheres(TAGM)combined with platinum spring coil with fiber(microcoils)in the treatment of acute severe hemoptysis caused by bronchiectasis.Methods A retrospective analysis of 48 patients with bronchiectasis was performed.After the lesion vessels were confirmed by angiography,the distal capillary bed was embolized with TAGM(300-500 μm),the middle blood flow was embolized with microcoils according to the diameter of the small artery,and then the proximal vessels were embolized with TAGM(500-700 μm)again.In patients with pulmonary artery/vein fistula,appropriate TAGM(500-700 μm)was selected according to the size of the fistula and the blood flow velocity,followed by dense embolization with multiple microcoils.The complete occlusion of the lesion vessel was confirmed again by arteriography after embolization.Results The overall success rate of operation was 95.83%.There were 36 patients with immediately stopped bleeding,6 cases with effective treatment,4 cases with improved treatment,1 case with invalid treatment due to the leakage of the responsible blood vessel,which was improved after the second embolization.There was 1 case died in surgery due to sudden massive hemoptysis,choking and suffocation.During the 3-51 months follow-up,1 patient died due to sudden massive hemoptysis;4 patients had recurrent hemoptysis due to poor control of infection and collateral circulation,which were controlled after reemboliza-tion,and 1 patient with bronchiectasis and pulmonary tuberculosis had repeated hemoptysis caused by multiple pulmonary lesions and severe pulmonary infection,performing on four times embolization.There was no patient with recurrent hemoptysis occurring recanalization of primary embolized vessel.During the follow-up,the overall survival rate was 97.87%,and the hemoptysis control rate was 87.23%.Conclusion TAGM combined with microcoils is safe and effective in the treatment of acute massive hemoptysis,which has good short-term effect and long-term prognosis.

2.
Chinese Journal of Radiology ; (12): 135-139, 2018.
Artículo en Chino | WPRIM | ID: wpr-707908

RESUMEN

Objective To explore the recyclability and safety of Celect retrievable filter placement in the prevention of pulmonary embolism in patients with deep venous thrombosis(DVT).Methods The data of 120 DVT patients with Celect retrievable filter were collected from the Second Hospital of Shanxi Medical University from August 2015 to March 2017 and analyzed retrospectively. The Celect filter was placed in the inferior vena cava(IVC)at the inferior margin of the renal vein for 1 to 2 cm by puncturing the contralateral femoral vein or right internal jugular vein.The filter retrieve risk was assessed within 8 weeks after being implanted. The filters would be recovered through the right jugular vein when meeting the recovery standard, and the retrieve methods included conventional method, removing the guide wire into a loop trap method and guiding wire into a loop combined with balloon assisted method.The perforation of the vena cava was observed and the tilt angle of the filter was measured.The success rate of Celect filter retrieve was evaluated by the Kaplan-Meier method. Results Celect filters were successfully implanted in 120 patients with DVT.The IVC filters were implanted through femoral vein in 111 patients and 2 cases via right internal jugular vein.No complications,asymptomatic pulmonary embolism and related death was found in all patients.Twenty four patients did not reach the standard of filter retrieve,and were follow-uped.Ninety six cases were treated with Celect retrievable filter,among which,93 cases were successfully recovered with the filter indwelling time ranging from 7 to 144 days and the median being 50 days.The failure of the filter retrieve occurred in 3 cases because of the serious tilt of the filter or the encapsulation of filter by inferior vena cava thrombus.Perforation of vena cava with no clinical symptoms occurred in 21 cases.Filter tilt was found in 35 cases,among which,15 cases had inclined angle>15 degrees or the recovery hook closed to the IVC wall.Thirteen cases with filter tip or recovery hook attached to the wall were successfully removed by using the guide wire into a loop or trap guide wire into a loop combined with balloon assisted method instead of routine removal method.The retrieve rate was 100% when the retention time of Celect filter in the body was within 106 days. Conclusion Celect retrievable filter can be implanted in DVT patients with long retrieve time window and high retrieve rate,but the filter inclination rate and vena cava perforation rate are high.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA