Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Presiones Respiratorias Máximas/instrumentación , Calor , Respiración Artificial/instrumentación , Capacidad Vital/fisiología , Estudios Transversales , Respiración con Presión Positiva/instrumentaciónRESUMEN
Some patients with coronavirus disease (COVID-19) present with severe acute respiratory syndrome, which causes multiple organ dysfunction, besides dysfunction of the respiratory system, that requires invasive procedures. On the basis of the opinions of front-line experts and a review of the relevant literature on several topics, we proposed clinical practice recommendations on the following aspects for physiotherapists facing challenges in treating patients and containing virus spread: 1. personal protective equipment, 2. conventional chest physiotherapy, 3. exercise and early mobilization, 4. oxygen therapy, 5. nebulizer treatment, 6. non-invasive ventilation and high-flow nasal oxygen, 7. endotracheal intubation, 8. protective mechanical ventilation, 9. management of mechanical ventilation in severe and refractory cases of hypoxemia, 10. prone positioning, 11. cuff pressure, 12. tube and nasotracheal suction, 13. humidifier use for ventilated patients, 14. methods of weaning ventilated patients and extubation, and 15. equipment and hand hygiene. These recommendations can serve as clinical practice guidelines for physiotherapists. This article details the development of guidelines on these aspects for physiotherapy of patients with COVID-19.
Asunto(s)
Humanos , Neumonía Viral/terapia , Terapia Respiratoria/métodos , Modalidades de Fisioterapia , Infecciones por Coronavirus/terapia , Coronavirus , Pandemias , Neumonía Viral/epidemiología , Respiración Artificial , Brasil , Infecciones por Coronavirus/epidemiología , Fisioterapeutas , Betacoronavirus , SARS-CoV-2 , COVID-19RESUMEN
RESUMO Objetivo: Avaliar as possíveis alterações do volume corrente, volume-minuto e frequência respiratória causadas pela utilização de trocadores de calor e umidade em pacientes submetidos à ventilação mecânica na modalidade pressão de suporte, e quantificar a variação da pressão de suporte necessária para compensar o efeito causado pelo trocador de calor e umidade. Métodos: Os pacientes sob ventilação mecânica invasiva na modalidade pressão de suporte foram avaliados utilizando umidificadores aquecidos e trocadores de calor e umidade. Caso o volume encontrado com uso de trocadores de calor e umidade fosse menor que o achado com o umidificador aquecido, iniciava-se o aumento da pressão de suporte, perante o uso de trocadores de calor e umidade, até ser encontrado um valor de pressão de suporte que possibilitasse ao paciente gerar um valor próximo do volume corrente inicial com umidificador aquecido. A análise foi realizada por meio do teste t pareado, e os valores de incremento foram expressos em porcentagem de aumento necessário. Resultados: Foram avaliados 26 pacientes. O uso de trocadores de calor e umidade aumentou a frequência respiratória, e reduziu o volume corrente e o volume-minuto, quando comparados com o uso do umidificador aquecido. Com o uso de trocadores de calor e umidade, os pacientes precisaram de um incremento de 38,13% na pressão de suporte para manter os volumes prévios. Conclusão: O trocador de calor e umidade alterou os parâmetros de volume corrente, volume-minuto e frequência respiratória, sendo necessário um aumento da pressão de suporte para compensar estas alterações.
ABSTRACT Objective: To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. Methods: Patients under invasive mechanical ventilation in pressure support mode were evaluated using heated humidifiers and heat and moisture exchangers. If the volume found using the heat and moisture exchangers was lower than that found with the heated humidifier, an increase in pressure support was initiated during the use of the heat and moisture exchanger until a pressure support value was obtained that enabled the patient to generate a value close to the initial tidal volume obtained with the heated humidifier. The analysis was performed by means of the paired t test, and incremental values were expressed as percentages of increase required. Results: A total of 26 patients were evaluated. The use of heat and moisture exchangers increased the respiratory rate and reduced the tidal and minute volumes compared with the use of the heated humidifier. Patients required a 38.13% increase in pressure support to maintain previous volumes when using the heat and moisture exchanger. Conclusion: The heat and moisture exchanger changed the tidal and minute volumes and respiratory rate parameters. Pressure support was increased to compensate for these changes.
Asunto(s)
Humanos , Masculino , Femenino , Anciano , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar , Frecuencia Respiratoria/fisiología , Humidificadores , Estudios Prospectivos , Calor , Persona de Mediana EdadRESUMEN
INTRODUÇÃO: A relevância do parênquima pulmonar distal na fisiopatologia da asma tem sido intensamente enfatizada. Vários estudos sugerem a inibição da Rho quinase como uma intervenção benéfica e promissora na asma. Entretanto, não há estudos anteriores que avaliaram os efeitos destes inibidores na modulação da mecânica do parênquima pulmonar e suas alterações histopatológicas em um modelo animal de inflamação pulmonar alérgica crônica. OBJETIVO: Avaliar a inibição da Rho quinase (Y-27632) na modulação da responsividade, inflamação, remodelamento da matriz extracelular e ativação do estresse oxidativo no parênquima pulmonar de cobaias com inflamação pulmonar alérgica crônica. MÉTODOS: As cobaias receberam sete inalações de ovalbumina (1-5 mg / ml; grupo OVA) ou salina (grupo SAL) ao longo de quatro semanas. A partir da quinta inalação, os animais do grupo Rho quinase foram submetidos a inalação com Y-27632, 10 minutos antes de cada inalação com OVA ou SAL. Setenta e duas horas após a sétima inalação, os animais foram anestesiados e exanguinados, e das tiras do tecido pulmonar foram realizadas a mecânica oscilatória, sob condições basais e após o desafio de ovalbumina (0,1%). Após a mecânica, as fatias de pulmão foram submetidas a análise histológica por meio da morfometria. RESULTADOS: A inibição de Rho quinase nos animais expostos à ovalbumina atenuou a elastância e a resistência tecidual, o número de eosinófilos, a expressão de IL-2, IL-4, IL-5, IL-13, TIMP-1, MMP-9, TGF-, IFN-g, NF-kB e iNOS e o conteúdo de 8-iso-PGF2, fibras elásticas, fibras colágenas e actina em comparação com o grupo OVA (P<0,05). CONCLUSÃO: A inibição da Rho quinase contribui para o controle da capacidade de responsividade do parênquima pulmonar, da inflamação eosinofílica, das respostas Th1/Th2, ao controle do remodelamento da matriz extracelular em um modelo animal de inflamação pulmonar alérgica crônica...
RATIONALE: Previous studies with Rho-kinase inhibitors suggest a beneficial influence of these drugs in asthma. The relevance of distal lung tissue in functional asthmatic impairment has been intensely emphasized. There have not been any previous studies evaluating the effects of these inhibitors on the modulation of distal lung mechanics and histopathological alterations in an animal model of chronic pulmonary inflammation. OBJECTIVE: To evaluate if Rho-kinase inhibition (Y- 27632) modulates distal lung responsiveness, inflammation, extracellular matrix remodeling and oxidative stress activation in guinea pigs with chronic allergic inflammation. METHODS: Guinea pigs received seven inhalations of ovalbumin (1-5 mg/ml; OVA group) or saline (SAL group) over 4 wk. From the 5th inhalation, the Rho-kinase group animals were submitted to Y-27632 inhalation 10 min before each inhalation with OVA or SAL. Seventy-two hours after the seventh inhalation, the animals were anesthetized and exsanguinated, and oscillatory mechanics of the lung tissue strips were performed under the baseline condition and after the ovalbumin challenge (0.1%). Afterwards, the lung slices were submitted to morphometry. RESULTS: The Rho-kinase inhibition in the ovalbumin-exposed animals attenuated the tissue elastance and resistance, eosinophils, the IL-2, IL-4, IL-5, IL-13, TIMP-1, MMP-9, TGF-, IFN-g, NF-kB, iNOS-positive cells and the 8-iso-PGF2, elastic, collagen and actin content compared with the OVA group (P<0.05). CONCLUSION: Rho-kinase inhibition contributes to the control of distal lung responsiveness and the eosinophilic and Th1/Th2 responses to the control of extracellular matrix remodeling in an animal model of chronic allergic inflammation. It may be considered a future pharmacological tool for the treatment of chronic pulmonary diseases.