Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-1030692

RESUMEN

ObjectiveTo establish a standardized and professional service quality evaluation index system for extracorporeal membrane oxygenation (ECMO) animalexperimental platform.Methods The literature research and expert consultation were used to establish a factor set for the quality evaluation of ECMO animal experimental platform. Then, experts used the 1/9-9 scale method to compare and score pair-two indicators. Based on the principles of fuzzy analytic hierarchy process and expert scoring results, the ECMO animal experimental platform quality evaluation system was constructed. In order to verify the actual efficacy of this system, a case study was carried out on the ECMO animal experiment platform of FW Animal Experimental Center (FAEC) laboratory.Results A total of 10 experts were included in this study, the questionnaire recovery rate was 100%, the judgment coefficient (Ca) and familiarity coefficient (Cs) were both greater than 0.50, the expert authority was high (Cr>0.80), the validity test was P<0.01, and the coordination was good. The quality evaluation system of ECMO animal experiment platform includes two levels. There are 4 first-level indicators, with professionalism, safety, functionality, and stability ranked from high to low in terms of their weights. There are 15 second-level indicators, and the top 5 weights are personnel's technical expertise, attractiveness of hardware facility, auditability of data, confidentiality capabilities of data, and professionalism in service process. To facilitate the popularization and application of the system, this study also proposed a "star" system to represent the evaluation results of an ECMO animal experimental platform quality. The quality evaluation system established in this study was used to evaluate the FAEC laboratory as a case study, and the evaluation result was five-star. The actual potency value of FAEC laboratory was 0.910, reaching the five-star level, but the average actual appraisal valuesof "service continuity" and "sufficiency of project completion" were lower than 0.80, which needs to be improved.ConclusionA standardized and professional ECMO animal experimental platform quality evaluation system was established in this study, which would provide a measurable basis for the demander to select the supplier and a method for the supplier to complete the animal experiment of ECMO research and development with high quality.

2.
Artículo en Chino | WPRIM | ID: wpr-744148

RESUMEN

Objective To compare the effects between the dual-cycle intensive training mode (DCITM) of "teaching-in vitro-in vivo-summary-in vitro-in vivo-assessment" and the single-cycle basic training mode (BTM) of "teaching-in vitro-tn vivo-assessment" on training graduate students majoring in cardiovascular surgery.Methods Eight graduate students majoring in cardiovascular surgery received the basic training of coronary artery bypass vascular anastomosis under the mode of BTM or DCITM.Then the training effects were evaluated by scoring of experts.Besides,SPSS 17.0 statistical software was used to analyze the evaluation results.Results Compared with students who received BTM,the postgraduates trained by DCITM became more skilled in vascular anastomosis.In vitro,the average number of anastomosis completed by trainee increased significantly [(2.0 ± 1.0) vs.(5.0 ± 1.5),P<0.05] over a specified period of time,the vascular leakage rate was significantly reduced [(92 ± 5)% vs.(30 ± 2)%,P<0.05],and the average time per anastomosis was significantly shorter [in vitro:(20.1 ± 2.5) min vs.(12.6 ± 3.3) min,P<0.05].There was also a statistically significant difference in the average time of each anastomosis in miniature pigs with coronary vascular anastomosis [in vivo:(30 ± 2) min vs.(21 ± 3) min,P<0.05].Conclusion Taken into together,DCITM is a highly efficient mode for promoting the quality of cardiovascular-surgery-teaching and enhancing the effectiveness of training in clinical surgical skills.

3.
Artículo en Chino | WPRIM | ID: wpr-706809

RESUMEN

Objective: To analyze the trend of lung cancer incidence rate among rural residents in Feicheng city between the years 2000 and 2012,and predict the incidence rate between the years 2013 and 2018,and subsequently provide baseline data for lung can-cer control and prevention.Methods:With the cancer registration data in Feicheng rural areas,the time trend of lung cancer inci-dence rate and the annual percentage change(APC)were calculated by the Joinpoint model,while the incidence of lung cancer from 2013 to 2018 were predicted by the ARIMA(p,d,q)model.Results:A total of 3,908 new cases of lung cancer were diagnosed be-tween 2000 to 2012.The incidence rate was 40.77/105,the age-specific cancer incidence rate in the Chinese population(ASRC)and world population(ASRW)were 32.95/105 and 32.97/105,respectively.The incidence was 2.14 times higher among males than females (P<0.001).The incidence of lung cancer which apparently rose from 25.13/105to 64.92/105 with an APC value of 9.74%(P<0.001),was increasing every year.The change in the trend of lung cancer with respect to age could be divided into three segments,the incidence rate in the 0 to 59 years group showed a rapid upward trend(APC=113.38,P<0.001),which was lower in the 60 to 79 years group (APC=20.39,P<0.05)and began to decline in the 80 years or older group(APC=-21.20,P>0.05).The incidence of lung cancer was also observed to be increasing yearly from 2013 to 2018,and with an average annual growth rate of 4.92%,was predicted to reach 87.92/105 in 2018.Conclusions:The occurrence of lung cancer was closely related to population aging,unhealthy habits,and environmental risk factors.Due to the increasing aging population,the incidence of lung cancer will continue to increase.In order to formulate specif-ic strategies,the control and prevention of lung cancer must be based on its incidence features.

4.
Artículo en Chino | WPRIM | ID: wpr-456049

RESUMEN

Objective To explore the feasibility of establishing mini-pig model of type 1 diabetes by single intrave-nous injection of high dose streptozotocin .Methods Eight male Zhonghua mini-pigs (22.6 ±1.8 kg) were administrated with high-dose streptozotocin (150 mg/kg) into the ear vein .Before and 10, 30, 90 minutes, 1, 3 and 7 days after adminis-tration of streptozotocin , blood samples were obtained respectively , and used to dynamically monitor the fasting blood-glucose. C peptide and insulin levels were evaluated by IVGTT test .Results Since 24 hours after STZ administration , the fasting blood-glucose level was increased significantly compared with that of pre-administration and maintained at 16.7-20.6 mmol/L, while the C peptide and insulin levels were decreased significantly .IVGTT results showed that blood sugar levels at 1 h af-ter intravenous injection of 50%glucose were much higher than 11.1 mmol/L and failed to restore to fasting glucose levels until 2 h, insulin and c-peptide did no response after injection of glucose , always kept at a trace level .Conclusion A sin-gle high-dose streptozotocin injection can be used to establish a mini-pig model of type 1 diabetes successfully .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA