Artículo en Chino | WPRIM | ID: wpr-1026304

RESUMEN

Objective To compare the value of 7 different thyroid imaging reporting and data systems(TI-RADS)for differentiating benign and malignant thyroid nodules under the context of Hashimoto thyroiditis(HT).Methods A total of 338 thyroid nodules in 200 HT patients were enrolled,including 167 benign and 171 malignant ones.Kwak-TIRADS,American Thyroid Association(ATA)guideline,American Association of Clinical Endocrinologists(A ACE)/American College of Endocrinology(ACE)/Associazione Medici Endocrinologi(AME)guideline,K-TIRADS of Korean Society of Thyroid Radiology,EU-TIRADS of European Thyroid Association,American College of Radiology(ACR)-TIRADS and 2020 Chinese guidelines for malignant risk stratification of thyroid nodules by ultrasound proposed by the superficial organs and vessels group of the ultrasound medicine branch of the Chinese Medical Association(C-TIRADS)were used for grading of benign and malignant thyroid nodules.Taken pathological results as gold standards,the diagnostic efficacy of 7 kinds of TI-RADS were analyzed.Results The sensitivity of Kwak-TIRADS,ATA guideline,A ACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS for differentiating benign and malignant thyroid nodules under the context of HT was 97.08%,98.25%,99.42%,95.91%,99.42%,90.06%and 99.42%,respectively,the specificity was 88.02%,83.23%,82.04%,88.02%,82.04%,86.83%and 84.43%,respectively,and the area under the curve(AUC)was 0.946,0.913,0.907,0.934,0.909,0.916 and 0.960,respectively.The sensitivity of C-TIRADS,EU-TIRADS and A ACE/ACE/AME guideline were all higher than that of K-TIRADS and ACR-TIRADS(all P<0.05),and the specificity of Kawk-TIRADS and K-TIRADS were both higher than that of C-TIRADS,ATA guideline,EU-TIRADS and AACE/ACE/AME guideline(all P<0.05),while AUC of C-TIRADS and Kawk-TIRADS were both higher than that of the rest 5 kinds of TI-RADS(all P<0.05).According to Kwak-TIRADS,ATA guideline,AACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS,the malignant rate of different grades nodules identified with the same TI-RADS were significant different(all P<0.05),which all raised with the increase of TI-RADS grade.Conclusion C-TIRADS and Kawk-TIRADS had better value for differentiating benign and malignant thyroid nodules under the context of HT,among which C-TIRADS had higher sensitivity and Kawk-TIRADS had higher specificity.

2.
Artículo en Chino | WPRIM | ID: wpr-756428

RESUMEN

Objective To investigate the capability oftomography ultrasound (TUI) in evaluating the development of the normal anorectal structure to provide a reference for prenatal diagnosis of imperforate anus.Methods From June 2017 to July 2018,315 singleton pregnant women at 19-40 weeks of gestational age were selected from Beijing Tiantan Hospital,and they ranged in age from 23 to 40 years,with an average age of 29±3 years.The TUI technique was applied to measure the fetal anal sphincter diameter (ASD),anal canal diameter (ACD),and anal canal length (ACL).The correlation between ASD,ACD,or ACL and gestational age was analyzed by Pearson correlation analysis,and the regression equation and curve were established.The intraclass correlation coefficient (ICC) and 95% confidence interval (CI) were used to evaluate the repeatability of the measurement ofASD,ACD,and ACL.Results The display rate of fetal anorectum in all fetuses by the TUI technique was 97.8% (308/315).Pearson correlation analysis showed that the normal fetal ASD,ACD,and ACL were positively correlated with the gestational age of the fetus,and the regression equations are:ASD,Y=-0.001X2 + 0.421X-1.726 (r=0.83,P < 0.01);ACD,Y=0.418X-4.207 (r=0.89,P < 0.01);and ACL,Y=0.526X-1.062 (r=0.87,P < 0.01).Conclusion TUI for assessment of fetal anorectum is feasible.This method can be applied to improve the display rate of fetal anorectum.

3.
China Oncology ; (12): 112-116, 2016.
Artículo en Chino | WPRIM | ID: wpr-491853

RESUMEN

Because of development and popularization of the ultrasound techniques, the detection rate of nodal thyroid has increased. Surgery is the long-established therapeutic option. However, due to the surgical trauma, compli-cations and the effect on quality of life, various minimally invasive treatments have been proposed and widely used. A large number of foreign studies have shown that ultrasound-guided percutaneous ethanol injection is a more commonly used minimally invasive way to treat benign pure cystic and predominantly cystic thyroid nodules. This article provides an up-to-date review of the overseas studies and summarized on percutaneous ethanol injection for the treatment of benign cystic thyroid nodules.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA