Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Artículo en Chino | WPRIM | ID: wpr-1022841

RESUMEN

Corneal refractive surgery is a safe and effective way to correct ametropia.Although the biomechanical stability of the cornea is reduced due to the change in corneal tissue integrity after surgery, the vast majority of postoperative corneal structures are safe.Patients with preoperative risk factors, such as high diopters, thin cornea, irregular corneal topography, high astigmatism, binocular asymmetry, allergic constitution, eye rubbing, etc., may experience postoperative refractive regression and corneal ectasia.Corneal collagen cross-linking can enhance the biomechanical properties of cornea and effectively prevent the occurrence and progression of corneal ectasia, keratoconus or other ectatic diseases.In recent years, many researchers at home and abroad have tried a new design of refractive surgery, that is, corneal refractive surgery with prophylactic corneal collagen cross-linking to improve the biomechanical stability of the cornea after refractive surgery, and then potentially prevent corneal ectasia and refractive regression.A number of studies have found that combined surgery has a good visual acuity and refractive prognosis, especially in patients at high risk for postoperative ectasia.This article reviews the efficacy, safety, predictability, stability, and complications of combined surgery.

2.
Arq. bras. oftalmol ; 87(4): e2023, 2024. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1557099

RESUMEN

ABSTRACT We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.

3.
Arq. bras. oftalmol ; 87(3): e2021, 2024. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1520219

RESUMEN

ABSTRACT A 33-year-old male presented with unilateral subacute infectious keratitis 4 weeks after surgery. Corneal inflammation was resistant to standard topical antibiotic regimens. During diagnostic flap lifting and sampling, the corneal flap melted and separated. Through flap lifting, corneal scraping, microbiological diagnosis of atypical mycobacteria, and treatment with topical fortified amikacin, clarithromycin, and systemic clarithromycin, clinical improvement was achieved.


RESUMO Paciente do sexo masculino, 33 anos, apresentou ceratite infecciosa subaguda unilateral 4 semanas após a cirurgia. A inflamação da córnea foi resistente aos regimes de antibióticos tópicos padrão. A aba da córnea foi derretida e seccionada durante o levantamento e amostragem para diagnóstico. A melhora clínica só foi alcançada após levantamento do retalho, raspagem e diagnóstico microbiológico de micobactérias atípicas e tratamento com amicacina fortificada tópica, claritromicina e claritromicina sistêmica.

4.
Rev. bras. oftalmol ; 83: e0036, 2024. graf
Artículo en Inglés | LILACS | ID: biblio-1565367

RESUMEN

ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Results: Analysis of 52 eyes from 26 patients revealed mean differences in vertex-optical distance of 12.25mm (right eye) and 11.75mm (left eye). A 2mm change in vertex-optical distance resulted in a 0.05D change for a 5D spherical equivalent and 0.20D for a 10D equivalent. Conclusion: Vertex-optical distance varies among patients and is influenced by forehead adjustment. These variations impact refraction accuracy and treatment evaluation. Adjusting the forehead to the third position on the Vision-S™ 700 is recommended.


RESUMO Objetivo: Estudar a variação da distância vértice-óptico, de acordo com o ajuste da testa, e estimar seu impacto na refração manifesta. Métodos: Estudo prospectivo realizado em clínica privada. A refração foi realizada utilizando cinco posições preestabelecidas com o Vision-Sa 700. A testa disposta na terceira posição apresentou distância vértice do refrator mais próxima de 12mm. Resultados: Foram analisados 52 olhos de 26 pacientes. A diferença média da distância vértice do refrator no olho direito foi de 12,25mm (variação de 11,50mm) e, no olho esquerdo, 11,75mm (variação de 12,00mm). O impacto foi de 2mm na distância vértice do refrator, fomentando em uma mudança de 0,05D para um equivalente esférico de 5D e 0,20D para um equivalente de 10D. Conclusão: A distância vértice do refrator varia entre pacientes, estando relacionada ao ajuste da testa. As variações afetam a precisão da refração, impactando no ajuste dos óculos, das lentes de contato e na avaliação pós-operatória de cirurgia refrativa. Sugerimos ajustar a posição da testa para terceira posição no Vision-S™ 700, se a distância vértice do refrator não for medida em todos os pacientes.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Optometría/instrumentación , Optometría/métodos , Refracción Ocular/fisiología , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Lentes , Postura , Errores de Refracción , Cefalometría , Estudios Prospectivos , Procedimientos Quirúrgicos Refractivos , Óptica y Fotónica , Posicionamiento del Paciente
5.
Arq. bras. oftalmol ; 86(1): 38-45, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1403477

RESUMEN

ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were used, and checked the results. Methods: Scleral contact lens fittings in a private clinic setting were prospectively analyzed in a sequential, non-randomized, and non-comparative manner. All the patients underwent a complete ophthalmic examination and had an indication for scleral lens use (Zenlens, Alden Optical). Results: Scleral fit was analyzed in 80 eyes of 45 patients. Regarding diagnosis, 72% of the patients had keratoconus; 12%, radial keratotomy; 5%, post-refractive surgery ectasia; 5%, dry eye; and 3%, high myopia. In 66 (82.5%) of the 80 eyes studied, parameters were modified when the lenses were ordered. The reasons that led to the modifications were apical touch or decreased sagittal height, increased sagittal height, cylindrical over-refraction, poor visual acuity, lens flexure, peripheral touch, 360° edge compression, horizontal edge compression, and vertical edge compression. Conclusion: In this study, the use of Zenlens scleral lenses was shown to be a promising corrective treatment for patients requiring the use of scleral lenses. Although the study suggests a learning curve, as many adjustments were allowed, the lens could be customized according to the patients' needs. This increased the success rates of fitting and wearing, and consequently, use of the lens became a great option for the visual rehabilitation of patients.


RESUMO Objetivo: Avaliar o processo de adaptação de uma lente escleral que permite vários ajustes de parâmetros durante os testes e após o período inicial do seu uso; verificar quais os ajustes foram necessários, quais foram os mais utilizados, as suas indicações, a frequência com que estes recursos foram utilizados, e avaliar os resultados das mudanças realizadas. Métodos: A adaptação da lente de contato escleral foi analisada prospectivamente, de forma sequencial, não aleatória e não comparativa. Todos os pacientes foram submetidos a um exame oftalmológico completo e tinham indicação para o uso de lentes esclerais. Foi utilizada a lente Zenlens (Alden Optical). Resultados: Foi analisada a adaptação de lentes de contato esclerais em 80 olhos de 45 pacientes. Quanto ao diagnóstico, 72% tinham ceratocone, 12% tinham sido submetidos a ceratotomia radial, 5% tinham ectasia pós-cirurgia refrativa, 5% tinham olho seco, e 3%, alta miopia. Em 66 dos 80 olhos estudados (82,5%), os parâmetros foram modificados quando as lentes foram encomendadas. As razões foram: toque apical ou diminuição da altura sagital, aumento da altura sagital, sobre-refração cilíndrica, baixa acuidade visual, flexão da lente, toque periférico, compressão da borda em 360° e compressão da borda horizontal e/ou vertical. Conclusão: O uso de lentes esclerais Zenlens demonstrou ser uma forma de correção muito promissora para os pacientes que requerem o uso de lentes esclerais. Embora o estudo sugira uma curva de aprendizagem, é possível personalizar as lentes de acordo com as necessidades de cada pacientes. Este fato melhora a adaptação e aumenta a chance de sucesso do uso.

6.
Journal of Chinese Physician ; (12): 1597-1600, 2023.
Artículo en Chino | WPRIM | ID: wpr-1026002

RESUMEN

In recent years, corneal refractive surgery has flourished, but some patients have developed visual adverse symptoms such as decreased nighttime vision, glare, and halo after surgery. As one of the important factors affecting postoperative visual quality, accurate measurement and evaluation of the effective optical area is particularly important. This not only provides guidance for the selection of preoperative surgical methods and the design of optical areas, but also provides better postoperative visual quality for patients. This article reviews the research progress on the design and effective optical area of corneal refractive surgery.

7.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1507881

RESUMEN

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Complicaciones Posoperatorias , Colgajos Quirúrgicos/patología , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/métodos , Dilatación Patológica/etiología , Láseres de Excímeros/efectos adversos , Errores de Refracción , Córnea/cirugía , Córnea/patología , Topografía de la Córnea/métodos , Tomografía de Coherencia Óptica , Dilatación Patológica/diagnóstico , Procedimientos Quirúrgicos Refractivos/métodos , Láseres de Excímeros/uso terapéutico
8.
Rev. bras. oftalmol ; 82: e0006, 2023. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1423620

RESUMEN

RESUMO Objetivo: Desenvolver e aplicar um questionário eletrônico para avaliação do conhecimento em cirurgia refrativa na população analisada. Métodos: Foi aplicado um questionário eletrônico a uma população composta de 840 participantes voluntários maiores de 18 anos. Resultados: A média da idade dos participantes foi 37,85 anos, sendo 60,1% do feminino. Dentre os participantes, 20,95% reportaram ter sido submetidos a alguma cirurgia ocular prévia, sendo 73,86% com objetivo refrativo. Entre estes, 73,08% mostraram-se satisfeitos/muito satisfeitos com o resultado. O critério mais importante na escolha de um cirurgião refrativo foi a indicação por um conhecido que realizara a cirurgia (43,81%). Destaca-se que os participantes submetidos à cirurgia refrativa discordaram que "a cirurgia é um procedimento simples e isento de riscos" mais do que as demais pessoas (p=0,0045) e também que "o objetivo principal da cirurgia é 'zerar' o grau" (p=0,0252). Conclusão: Nota-se a necessidade de melhorar o conhecimento pré-operatório da população sobre cirurgia refrativa e também de educação continuada para os oftalmologistas. Este estudo fomenta o desenvolvimento de novas ferramentas de educação com informações claras e de fácil acesso, que tenham caráter informativo, e não de convencimento.


ABSTRACT Objective: The purpose of this study was to develop and apply an online questionnaire to assess knowledge in Refractive Surgery in the analyzed population. Methods: An online questionnaire was applied to a population composed of 840 volunteer participants over 18 years of age. Results: The mean age of population was 37.85 years, of whom 60.1% were female. 20.95% of the participants reported having undergone previous eye surgery, 73.86% of which had a refractive objective. Among these, 73.08% were satisfied / very satisfied with the result. The most important criterion when choosing a refractive surgeon was the indication by a friend who underwent the procedure (43.81%). It is noteworthy that the participants who underwent refractive surgery disagreed more than the other people that "the surgery is a simple and risk-free procedure" (p = 0.0045) and that "the main objective of the surgery is to "zero" the diopter" (p = 0.0252). Conclusion: It is essential to improve population's preoperative knowledge about Refractive Surgery, as well as continuing education for ophthalmologists. Therefore, this study encourages the development of new education tools with clear and easily accessible information, which should be informative, and not convincing.

9.
Indian J Ophthalmol ; 2022 May; 70(5): 1533-1537
Artículo | IMSEAR | ID: sea-224298

RESUMEN

Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront?based objective refraction may be useful in the evaluation of patients. So far, the reliability of objective refraction as measured using the Pentacam® AXL Wave has not been published in the literature. Methods: This was a prospective study including a total of 168 eyes belonging to 84 young non?presbyopic patients evaluated for refractive surgery. Pentacam® AXL Wave full sequence was taken for all patients. Then, a clinician who was unaware of the objective refraction results performed a full physical examination, including manifest refraction starting from an autorefractometer value. All refraction values were transferred to astigmatic power vectors as per the Thibos method. Reliability of the different vectors and a unifying blur value were compared using Spearman correlation, Bland–Altman plot, and intraclass correlation coefficient. Results: The mean age was 28.8 ± 5.4 years, with a female preponderance (60.7%). The correlation between both eyes was high. The difference in M vector between subjective and objective refraction was 0.16 D, while the difference was 0.04 and 0.01 D for the J0 and J45 vectors, respectively. Paired samples Student t was non?significant for all comparisons. Spearman rho correlations were high (0.666–0.924, all P < 0.001). Intraclass correlation coefficients were also high (0.890–0.966). Bland–Altman plots did not demonstrate any systematic errors. Conclusion: Wavefront?based refractive refraction obtained using the Pentacam® AXL Wave is highly agreeable and correlated with measurements obtained by manifest subjective refraction.

10.
Artículo en Chino | WPRIM | ID: wpr-908625

RESUMEN

Refractive surgery is one of the important methods for refractive error correction, which include corneal refractive surgery and intraocular refractive surgery.In recent years, refractive surgery has a rapid development, and there is still development space and potential market demand.The clinical application of various new technologies has brought the refractive surgery to a new stage.The ultimate aim of refractive surgery is to pursue safer minimally invasive approaches and more customized correction for better visual quality.The new approaches including the guidance of corneal topography and wavefront aberration, the Q-value adjustment, Kappa angle adjustment, and customized corneal cross-linking during the surgery have been developed.The integration of various surgical approaches and research is also a new development direction.The combination with intelligent operation to improve the efficiency and accuracy of treatment seems to be one new direction, too.Ophthalmologists should pay attention to the current development and the possible future directions and trends of refractive surgery in China.

11.
Arq. bras. oftalmol ; 83(1): 65-68, Jan.-Feb. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1088960

RESUMEN

ABSTRACT We describe a case of keratomycosis caused by Arthographis kalrae after excimer laser keratomileusis. A 38-year-old female developed stromal keratitis eight weeks after refractive surgery. She developed severe corneal stromal infiltration and mild anterior segment inflammation, which could not be treated with topical voriconazole 1%, but topical natamycin 5% ameliorated her condition. A reactivation of keratomycosis symptoms was observed; therefore, longer treatment was administered to the patient. It has been reported that A. kalrae keratomycosis is associated with exposure to soil and contact lens usage. However, the patient, who lived in a rural location, was neither involved in gardening activities nor had a history of wearing contact lenses. This is the first case of post-refractive A. kalrae keratomycosis.


RESUMO Descrevemos um caso de ceratomicose por Arthographis kalrae após ceratomileusis por excimer laser. Uma mulher de 38 anos desenvolveu ceratite estromal oito semanas após a cirurgia refrativa. Ela desenvolveu infiltração estromal grave da córnea e uma leve inflamação do segmento anterior, que não pode ser tratada com voriconazol tópico a 1%, mas a natamicina tópica a 5% melhorou sua condição. Uma reativação dos síntomas de ceratomicose foi observada; portanto, tratamento mais prolongado foi administrado a paciente. Tem sido relatado que a ceratomicose por A. kalrae está associada à exposição ao solo e ao uso de lentes de contato. No entanto, a paciente, que vivía em um local rural, não estava envolvida em atividades de jardinagem e nem tinha histórico de uso de lentes de contato. Este é o primeiro caso de ceratomicose pós-refrativa por A. kalrae.


Asunto(s)
Humanos , Femenino , Adulto , Infecciones Fúngicas del Ojo/microbiología , Queratitis/microbiología , Ascomicetos/aislamiento & purificación , Infecciones Fúngicas del Ojo/tratamiento farmacológico , Natamicina/uso terapéutico , Queratomileusis por Láser In Situ/efectos adversos , Voriconazol/uso terapéutico , Queratitis/tratamiento farmacológico
12.
Arq. bras. oftalmol ; 83(1): 76-81, Jan.-Feb. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1088947

RESUMEN

ABSTRACT The point of centration for refractive surgery is a theme of great importance that generates considerable discussion among specialists and surgeons in the field. Notably, any changes in light can alter the size of the pupil, and the visual axis of the fixation line to the fovea is unique in each patient. A variety of options have been described in the literature with respect to centration in refractive surgery, and the results differ among these methods. No consensus has been established regarding the ideal refractive surgery technique for evaluation of centration in each patient that will yield a satisfactory surgical result.


RESUMO O ponto de centralização da cirurgia refrativa é tema de grande importância e gera muita discussão entre especialistas e cirurgiões da área. Afinal, qualquer alteração na luz pode alterar o tamanho da pupila, além disso, o eixo visual da linha de fixação para a fóvea é particular em cada paciente. Existem opções para centralização em cirurgia refrativa com resultados diferentes na literatura. Ainda não há consenso sobre a melhor técnica em cirurgia refrativa que avalie cada caso específico visando um resultado cirúrgico final satisfatório.


Asunto(s)
Humanos , Pupila/fisiología , Córnea/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros , Refracción Ocular , Córnea/patología , Fijación Ocular
13.
Artículo en Chino | WPRIM | ID: wpr-799389

RESUMEN

Although binocular vision problems do not appear to be one of the common complications of refractive surgery, the available evidence suggests that these problems can occur after refractive surgery, and preoperative binocular vision status may predict the risk of postoperative binocular vision anomalies.Furthermore, because ophthalmologists usually do not clearly recognize binocular vision, or they do not pay enough attention to it, the existing literature may underestimate the actual prevalence of binocular vision problems after refractive surgery.This paper discusses the existing literature on refractive surgery-related binocular vision anomalies and recommends a screening protocol and risk stratification.It also discusses the expected results of binocular vision testing, the diagnostic criteria for common binocular vision problems, and strategies for treating these anomalies before and after refractive surgery.

15.
Artículo en Chino | WPRIM | ID: wpr-865230

RESUMEN

Although binocular vision problems do not appear to be one of the common complications of refractive surgery,the available evidence suggests that these problems can occur after refractive surgery,and preoperative binocular vision status may predict the risk of postoperative binocular vision anomalies.Furthermore,because ophthalmologists usually do not clearly recognize binocular vision,or they do not pay enough attention to it,the existing literature may underestimate the actual prevalence of binocular vision problems after refractive surgery.This paper discusses the existing literature on refractive surgery-related binocular vision anomalies and recommends a screening protocol and risk stratification.It also discusses the expected results of binocular vision testing,the diagnostic criteria for common binocular vision problems,and strategies for treating these anomalies before and after refractive surgery.

16.
Artículo en Inglés | WPRIM | ID: wpr-760054

RESUMEN

PURPOSE: To investigate the clinical effects of different orientation and magnitude of cyclotorsion on the compensation capacity of the WaveLight EX500 photorefractive keratectomy (PRK) platform. METHODS: This retrospective study comprised 400 eyes of 200 patients who underwent bilateral simultaneous PRK due to compound myopic astigmatism. The subjects were separated according to the orientation of cyclotorsion into incyclotorsion and excyclotorsion groups, and by the magnitude of cyclotorsion into group 1 (0.50 to 2.50 degrees), group 2 (3.00 to 5.00 degrees), group 3 (5.50 to 7.50 degrees), and group 4 (8.00 to 9.50 degrees). RESULTS: The mean magnitude of cyclotorsion was 3.50 ± 2.4 degrees (0.50 to 9.50 degrees) in the incyclotorsion group and 3.32 ± 2.3 degrees (0.50 to 9.50 degrees) in the excyclotorsion group (p = 0.617). The postoperative refractive outcomes of the incyclotorsion and excyclotorsion groups were similar (p > 0.05 for all). The postoperative mean cylindrical refractive error was −0.32 ± 0.3 diopters (D, −1.25 to 0.00 D) in group 1, −0.47 ± 0.2 D (−2.00 to 0.00 D) in group 2, −0.62 ± 0.2 D (−1.00 to −0.25 D) in group 3, and −0.91 ± 0.2 D (−1.50 to −0.50 D) in group 4 (p < 0.001). Preoperative cylindrical refractive error was positively correlated with magnitude of cyclotorsion (r = 0.125 and p = 0.013), which was also positively correlated with postoperative cylindrical refractive error (r = 0.600 and p < 0.001). CONCLUSIONS: Incyclotorsion and excyclotorsion can be equally compensable in the WaveLight EX500 PRK platform for compound myopic astigmatism. A value of ≤2.50 degrees cyclotorsion magnitude was observed to be more compensable than higher degrees of cyclotorsion magnitude. Preoperative high astigmatism was associated with high cyclotorsion magnitude, which was also associated with a high degree of postoperative astigmatism.


Asunto(s)
Humanos , Astigmatismo , Compensación y Reparación , Miopía , Queratectomía Fotorrefractiva , Errores de Refracción , Procedimientos Quirúrgicos Refractivos , Estudios Retrospectivos
17.
Artículo en Inglés | WPRIM | ID: wpr-741289

RESUMEN

PURPOSE: To evaluate changes in clinical practice in the field of refractive surgery in Korea over the past 10 years. METHODS: A survey consisting of 59 multiple-choice questions regarding the preferred types of refractive surgery, excimer laser machine, and presbyopia surgery was mailed to 742 members of the Korean Society of Cataract and Refractive Surgery in January 2016, and 50 members responded to the survey. These data were compared with the 2005 or 2007 survey results.


Asunto(s)
Catarata , Queratectomía Subepitelial Asistida por Láser , Queratomileusis por Láser In Situ , Corea (Geográfico) , Láseres de Excímeros , Miopía , Lentes Intraoculares Fáquicas , Servicios Postales , Presbiopía , Procedimientos Quirúrgicos Refractivos , Encuestas y Cuestionarios
18.
Artículo en Inglés | WPRIM | ID: wpr-718813

RESUMEN

PURPOSE: To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery. METHODS: We performed a retrospective review of the medical records of 69 patients (69 eyes) who had undergone myopic laser refractive surgery previously and subsequently underwent cataract surgery at Samsung Medical Center in Seoul, South Korea from January 2010 to June 2016. None of the patients had pre-refractive surgery biometric data available. The Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug total corneal refractive power (TCRP) 3 and 4 mm (SRK-T and Haigis), Scheimpflug true net power, and Scheimpflug true refractive power (TRP) 3 mm, 4 mm, and 5 mm (SRK-T and Haigis) methods were employed. IOL power required for target refraction was back-calculated using stable post-cataract surgery manifest refraction, and implanted IOL power and formula accuracy were subsequently compared among calculation methods. RESULTS: Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug TCRP 4 mm (Haigis), Scheimpflug true net power 4 mm (Haigis), and Scheimpflug TRP 4 mm (Haigis) formulae showed high predictability, with mean arithmetic prediction errors and standard deviations of −0.25 ± 0.59, −0.05 ± 1.19, 0.00 ± 0.88, −0.26 ± 1.17, 0.00 ± 1.09, −0.71 ± 1.20, and 0.03 ± 1.25 diopters, respectively. CONCLUSIONS: Visual outcomes within 1.0 diopter of target refraction were achieved in 85% of eyes using the calculation methods listed above. Haigis-L, Barrett True-K (no history), and Scheimpflug TCRP 4 mm (Haigis) and TRP 4 mm (Haigis) methods showed comparably low prediction errors, despite the absence of historical patient information.


Asunto(s)
Humanos , Catarata , Corea (Geográfico) , Lentes Intraoculares , Registros Médicos , Métodos , Procedimientos Quirúrgicos Refractivos , Estudios Retrospectivos , Seúl
19.
MedUNAB ; 21(1): 31-45, 2018.
Artículo en Inglés | LILACS | ID: biblio-970612

RESUMEN

Introduction. Corneal power determination after refractive surgery with excimer laser is complex. Different alternatives with the use of corneal tomography have been used for this measurement. Objective. To evaluate various methods of determination of corneal power in patients undergoing photorefractive surgery, including diagnostic tests with quantitative measurements. Methodology. This is a retrospective observational study. We included patients undergoing photorefractive surgery with refractive results and post-operative corneal tomography taken at least ten weeks after surgery. Results. In myopic eyes, significant differences were found in the value determined by the keratometry derived from the clinical history when compared with the average post-operative manual keratometry, the simulated 32keratometry and the Mean Pupil Power of the Sirius®tomograph. On another note, when averaging the mean post-operative manual keratometry with the post-operative Mean Pupil Power (value called Kpopaverage 1) and comparing it with the keratometry derived from the clinical history method, no statistically significant differences were observed in myopic patients. Likewise, when averaging the simulated post-operative keratometry of the Sirius® equipment with the post-operative Mean Pupil Power (value called "Kpop average 2") and comparing it with the keratometry derived by the method of the clinical history, no statistically significant differences were observed in myopic patients. On the other hand, in hyperopic eyes and those with mixed astigmatism, mean errors from post-operative Mean Pupil Power, in comparison to the keratometry derived by clinical history method, were not significantly different from the errors when comparing the "Kpop average 1" and the "Kpop average 2"with keratometry derived by the clinical history method. Conclusions. In myopic eyes the post-operative corneal power determinations with the "Kpop average 1" and "Kpop average 2" are closer to the keratometry derived by clinical history method than to measurements from the average post-operative manual keratometry, the post-operative simulated keratometry or the Mean Pupil Power of the Sirius® equipment.


Introducción. La determinación del poder corneal, después de la cirugía refractiva con láser excimer, es difícil. Diferentes alternativas con el uso de tomógrafos corneales se han utilizado para esta medición. Objetivo. Evaluar diversos métodos de determinación del poder corneal en pacientes operados de cirugía fotorrefractiva, incluyendo pruebas diagnósticas con medidas cuantitativas. Metodología. Estudio retrospectivo de pacientes operados de cirugía fotorrefractiva que tuvieran resultados refractivos y tomografía corneal post-operatoria al menos diez semanas luego de cirugía. Resultados. En los ojos miopes se encontraron diferencias significativas en el valor determinado por la queratometría derivada de la historia clínica al compararla con la queratometría manual promedio postoperatoria, la queratometría simulada y el Mean Pupil Power del tomógrafo Sirius®. Por otra parte, al promediar la queratometría manual promedio postoperatoria con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 1) y compararla con la queratometría derivada por el método de la historia clínica, no se observaron en los pacientes miopes diferencias estadísticamente significativas. Asimismo, al promediar la queratometría simulada postoperatoria del equipo Sirius® con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 2) y compararla con la queratometría derivada por el método de la historia clínica tampoco se observaron en los pacientes miopes diferencias estadísticamente significativas. Por otro lado, en los ojos hipermétropes y con astigmatismo mixto, los promedios de los errores del Mean Pupil Power postoperatorio, con respecto a la queratometría derivada por el método de la historia clínica, no fueron significativamente diferentes de los errores al comparar la Kpop promedio 1 y la Kpop promedio 2 con la queratometría derivada por el método de la historia clínica. Conclusiones. En ojos miopes las determinaciones del poder corneal postoperatorio con las Kpop promedio 1 y Kpop promedio 2 se aproximan más a la queratometría derivada por el método de la historia clínica que a las mediciones de la queratometría manual promedio postoperatoria, la queratometría simulada postoperatoria o el Mean Pupil Power del equipo Sirius®. [Jaramillo LC, Galvis V, Tello A, Camacho PA, Castillo A, Pareja LA. Determinación del poder corneal con un tomógrafo corneal luego de cirugía refractiva con láser excimer. MedUNAB. 2018;21(1):16-30. doi:1029375/01237047.2397].


Introdução. A determinação da potência corneana, após a cirurgia refrativa com excimer láser, é difícil. Foram usadas diferentes alternativas com o uso de tomógrafos de córnea para esta medição. Objetivo. Avaliar vários métodos de determinação da potência corneana em pacientes submetidos à cirurgia fotorrefrativa, incluindo testes diagnósticos com medidas quantitativas. Métodos. Este é um estudo observacional retrospectivo. Foram incluídos pacientes submetidos à cirurgia fotorrefrativa com resultados refrativos e topografía corneana pós-operatória pelo menos um mês após a cirurgia. Resultados. Nos olhos míopes foram encontradas diferenças significativas no valor determinado pela ceratectomia derivada da história clínica, quando comparada com a média da ceratectomia manual pós-operátoria, a ceratectomia simulada e o Mean Pupil Power do tomógrafo Sirius®. Por outro lado, ao calcularmos a média da ceratectomia manual pós-operatória com o Mean Pupil Power pós-operatório (valor denominado Kpop média 1) e compará-la com a ceratectomia pelo método da história clínica, não foram observadas diferenças estatisticamente significantes nos pacientes miopes. Da mesma forma, ao calcular a média da ceratectomia pós-operatória simulada do equipamento Sirius® com o Mean Pupil Power pósoperatório (valor denominado Kpop média 2) e comparála com a ceratectomia derivada do método de história clínica, não foram observadas diferenças estatisticamente significantes nos pacientes miopes. Por outro lado, em olhos hipermetrópicos e com astigmatismo mixto, as médias de erros do Mean Pupil Power pós-operatório, em relação à ceratectomia derivada pelo método da história clínica, não foram significativamente diferentes dos erros na comparação do Kpop média 1 y la Kpop média 2 com a ceratectomia derivada pelo método da história clínica. Conclusões. Nos olhos míopes, as determinações de potência corneana pósoperatória com Kpop média 1 e Kpop média 2 estão mais próximas da ceratectomia derivada pelo método da história clínica do que das medidas de ceratectomia manual média pós-operatória, da ceratectomia simulada pós-operatória ou Mean Pupil Power do equipamento Sirius®. [Jaramillo LC, Galvis V, Tello A, Camacho PA, Castillo A, Pareja LA. Determinação da potência corneana com uma topografia de córnea após cirurgia refrativa com excimer láser. MedUNAB. 2018;21(1):16-30. doi:1029375/01237047.2397].


Asunto(s)
Topografía de la Córnea , Errores de Refracción , Queratectomía Fotorrefractiva , Córnea , Procedimientos Quirúrgicos Refractivos , Láseres de Excímeros
20.
Rev. bras. oftalmol ; 76(2): 101-105, Mar.-Apr. 2017. graf
Artículo en Portugués | LILACS | ID: biblio-899044

RESUMEN

Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A revisão criteriosa dos estudos publicados na literatura ate o momento revelam resultado satisfatórios quanto à eficácia, elevada previsibilidade, estabilidade e segurança do implante de lente intraocular de câmara posterior, para correção das miopia, hipermetropia e astigmatismo.


Abstract The objective of this article was to gather studies that report results available in the scientific literature, considering the predictability, safety, efficacy, and stability of posterior chamber phakic intraocular lenses. And report the documented complications for these lenses.


Asunto(s)
Humanos , Errores de Refracción , Implantación de Lentes Intraoculares/métodos , Procedimientos Quirúrgicos Refractivos/métodos , Lentes Intraoculares Fáquicas , Complicaciones Posoperatorias , Refracción Ocular/fisiología , Astigmatismo/cirugía , Resultado del Tratamiento , Segmento Posterior del Ojo/cirugía , Hiperopía/cirugía , Miopía/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA