RÉSUMÉ
ABSTRACT: Orthodontic cements have been used to enhance retention between the band and the crown, however, unfavorable properties found in many of these cements may contribute to cement failure between band and crown's surface and leading to unsuccessful application of orthodontic forces. The aim of this study was to evaluate the shear strength of the Orthobite composite (FGM) using the Single Bond adhesive system (3M). The sample consisted of 30 bovine incisors divided in 2 groups (n=15). All teeth were submitted to prophylaxes with pumice stone and etching with phosphoric acid. In Group I the Orthobite was used conventionally. Group II was similar to Group I, however, the Single Bond adhesive system was applied after conditioning. The samples were stored in distilled water in incubator at 37 ºC for 24 h and submitted to the shear strength test at a speed of 0.5 mm/minute speed. Data were submitted to the Student T test (5 %). The results (MPa) showed no statistically significant differences between the groups, regardless of surface treatment. Thus, all groups exhibited adequate adhesive bond strength for clinical use.
RESUMEN: Los cementos ortodónticos se han utilizado para aumentar la retención entre la banda y la corona, sin embargo, las propiedades desfavorables encontradas en muchos de estos cementos pueden contribuir a la falla del cemento entre la superficie de la banda y la corona y llevar a la aplicación incorrecta de fuerzas de ortodoncia. El objetivo de este trabajo fue evaluar la resistencia al cizallamiento del compuesto Orthobite (FGM) utilizando el sistema adhesivo Single Bond (3M). La muestra consistió de 30 incisivos bovinos divididos en dos grupos (n = 15). Todos los dientes recibieron profilaxis con piedra pómez y acondicionamiento del esmalte con ácido fosfórico. En el Grupo I, se utilizó Orthobite de manera convencional. El Grupo II fue similar al I, pero se aplicó el sistema adhesivo Single Bond, después de acondicionamiento. Los cuerpos de prueba fueron almacenados en agua destilada en estufa a 37 ºC por 24 h y sometidos al ensayo de resistencia al cizallamiento, con velocidad de 0,5 mm por minuto. Los datos fueron sometidos a la prueba de T Student (5 %). Los resultados (en MPa) no mostraron diferencias estadísticamente significativas entre los grupos, independientemente del tratamiento de la superficie. De esta forma, todos los grupos presentaron resistencia adhesiva adecuada para uso clínico.
Sujet(s)
Animaux , Bovins , Appareils orthodontiques , Collage dentaire , Ciment ionomère au verre , Résistance à la traction , Résines acryliques , Brackets orthodontiques , Statistique non paramétrique , Résistance au cisaillementRÉSUMÉ
OBJECTIVE: To evaluate, in vitro, the shear bond strength of self-curing (ConciseTM - 3M and Alpha Plast - DFL) and light-curing composites (TransbondTM XT - 3M and Natural Ortho - DFL) used in orthodontics bonding, associated to Morelli metal brackets, with further analysis of adhesive remnant index (ARI) and enamel condition in scanning electron microscopy (SEM). METHODS: Forty human premolars, just extracted and stored in physiologic solution 0.9 % were used. Randomly, these samples were divided in four groups: G1 group, the brackets were bonded with ConciseTM - 3M composite; in G2 group, Alpha Plast - DFL composite was used; in G3 group, TransbondTM XT - 3M was used; in G4 group, Natural Ortho - DFL composite was used. These groups were submitted to shear strength tests in universal testing machine, at 0.5 mm per minute speed. RESULTS: Statistical difference between G3 and G4 groups was recorded, as G4 showing higher strength resistance than G3. In the other hand, there were no statistical differences between G1, G2 and G3 and G1, G2 and G4 groups. ARI analysis showed that there was no statistical difference between the groups, and low scores were recorded among then. The scanning electron microscopy (SEM) analysis revealed the debonding spots and the enamel surface integrity. CONCLUSIONS: Shear bond strength was satisfactory and similar between the composites, however Natural Ortho - DFL revealed best comparing to TransbondTM XT - 3M.
OBJETIVO: avaliar in vitro a resistência ao cisalhamento de compósitos autopolimerizáveis (Concise e Alpha Plast) e fotopolimerizáveis (Transbond XT e Natural Ortho) utilizados na colagem de braquetes metálicos da marca Morelli, analisando o índice de adesivo remanescente (ARI) e da integridade da superfície do esmalte por meio de microscopia eletrônica de varredura (MEV). MÉTODOS: foram utilizados 40 pré-molares humanos extraídos. As raízes dos dentes foram incluídas em gesso-pedra especial, no interior de tubos de PVC usados para a confecção dos corpos de prova. Esses corpos de prova foram divididos em quatro grupos: grupo G1, braquetes associados ao compósito Concise; grupo G2, braquetes associados ao compósito Alpha Plast; grupo G3, braquetes associados ao compósito Transbond XT; e grupo G4, braquetes associados ao compósito Natural Ortho. Os grupos foram submetidos ao teste de cisalhamento em máquina universal de ensaios, a uma velocidade de 0,5mm por minuto. RESULTADOS: houve diferença estatística entre os grupos G3 e G4, sendo os valores de G4 superiores; no entanto, não foram encontradas diferenças estatisticamente significativas entre os grupos G1, G2 e G3 e G1, G2 e G4. Na análise do ARI não foram encontradas diferenças estatísticas entre os grupos, predominando escores baixos. De acordo com a análise da MEV, constatou-se o rompimento dos compósitos e a integridade do esmalte entre os grupos. CONCLUSÃO: a resistência ao cisalhamento foi satisfatória e semelhante entre os compósitos utilizados, sendo que a resina Natural Ortho apresentou-se superior à Transbond XT.
Sujet(s)
Humains , Résines composites/composition chimique , Collage dentaire , Photopolymérisation d'adhésifs dentaires , Brackets orthodontiques , Autopolymérisation de résines dentaires , Analyse de variance , Adhésifs/analyse , Méthacrylate bisphénol A-glycidyl , Émail dentaire , Analyse du stress dentaire , Test de matériaux , Microscopie électronique à balayage , Polymérisation , Céments résine , Résistance au cisaillement , Statistique non paramétriqueRÉSUMÉ
O objetivo deste trabalho foi fazer uma análise comparativa entre dois métodos de pré-determinação do formato do arco dentário, (Diagrama de Interlandi® - DI) e Diagrama Individual Anatômico Objetivo (DIAO), buscando avaliar a replicabilidade entre medidas (distância intercaninos, intermolares, comprimento e perímetro do arco). Foram selecionados 40 modelos ortodônticos de pacientes portadores de má-oclusão Classe II de Angle. Os diagramas foram selecionados baseados na metodologia preconizada por cada autor e as medidas foram realizadas nos modelos de estudo e nos diagramas selecionados com auxílio de um paquímetro digital. Para análise da replicabilidade foi utilizado o Teste de Correlação Intraclasse e na comparação das medidas obtidas foi utilizado o teste ANOVA (α=5%). Os Resultados indicaram replicabilidade média a boa para as medidas distância intercaninos e intermolares, e excelentes para o comprimento e perímetro do arco para os dois métodos em comparação aos modelos. A comparação entre os dois métodos (DI DIAO) apresentou replicabilidade excelente para todas as medidas. Na comparação (Modelo DI DIAO) a única medida que não foi compatível entre eles foi a distância intermolares. Os diagramas avaliados podem ser utilizados como métodos eficientes de pré-determinação do formato do arco dental.
The aim of this work was a comparative analysis of two methods for pre-termination of dental arch form: Interlandi Diagram® and Objective Anatomic Individual Diagram (OAID), seeking to evaluate intercanine distance, intermolar distance, arch length and arch perimeter measurements repeatability. Fourty orthodontic dental casts of class II patients were selected. The diagrams were selected based on the methodology recommended by each author. Theeasurements were performed on dental casts and selected diagrams with digital caliper. Intraclass correlation test was used to analyze the repeatability, and ANOVA to compare the measurements obtained. When compared to dental casts, average-to-good repeatability for intercanine and intermolar distance measures and excellent for arch length and arch perimeter was found. DI-DIAO comparison showed excellent repeatability for all measures. Intermolar distance was the only nonconforming measure in dental cast-DI-DIAO comparisons. The diagrams evaluated can be used as efficient methods of pre-determining the dental arch form.
Sujet(s)
Humains , Mâle , Femelle , Arcade dentaire , Diagnostic buccal , Malocclusion dentaire , OrthodontieRÉSUMÉ
Objetivos: Desenvolver e discutir as possíveis aplicações de um método para estimulação barorreceptora, através de um novo aparelho que permite a realização da manobra de Valsalva de forma automatizada e não-assistida. Métodos: Um manômetro digital foi projetado e desenvolvido pelo Centro de Microgravidade/ FENG-PUCPR para monitorar a pressão intratorácica exercida durante a expiração forçada ou Manobra de Valsalva. Resultados: O equipamento, denominado de Equipamento para Manobra de Valsalva, é constituído de cinco partes principais, sendo elas: um transdutor de pressão (sensor de pressão e amplificador de sinais), um mostrador de caracteres, um mostrador em barra de Diodo Emissor de Luz e um micro-controlador. Testes preliminares indicaram que este novo equipamento permite que um indivíduo realize a manobra de Valsalva de forma correta e sem qualquer assistência durante o procedimento. Conclusões: O aparelho desenvolvido é de fácil manuseio e visualização, leve, portátil e de baixo custo.
Sujet(s)
Impesanteur , Baroréflexe , Équipement et fournitures , Manoeuvre de Vasalva , Moniteurs de pression artérielleRÉSUMÉ
A otimização da performance mental e a minimização dos erros podem salvar vidas e reduzir custos de missões aeroespaciais. Usando o teste de performance mental computadorizada Manikin Test, pôde-se avaliar aspectos importantes da performance cognitiva sob a influência da escopolamina, medicamento largamente utilizado para prevenir ou minimizar os efeitos da Doença da Locomoção Espacial, durante uma simulação de microgravidade. Para simular os efeitos fisiológicos da microgravidade na Terra, utilizou-se a inversão postural, onde o indivíduo é deitado sobre um leito e a parte do seu corpo fica abaixo da parte inferior (6º negativos ou 6º HDT, head-down tilt). Realizou-se um estudo duplo-cego, randomizado cruzado, no qual foi avaliada a performance mental de 15 voluntários durante simulação de microgravidade com e sem o uso de escopolamina 0,45mg. Constatou-se que, apesar da ocorrência de efeitos adversos inerentes à escopolamina, não houve diminuição da performance mental dos voluntários. Assim mais estudos são necessários para elucidar os reais efeitos da escopolamina sobre a performance mental durante a simulação de microgravidade. Assim, será possível a criação de medidas medicamentosas efetivas na prevenção e/ou na minimização dos sintomas provocados pela Doença da Locomoção Espacial.
Sujet(s)
Humains , Femelle , Mâle , Scopolamine , LocomotionRÉSUMÉ
A deficiência de médicos em áreas remotas dificulta o diagnóstico e o manejo de doenças. O Tele-ECG Digital (SED) foi estabelecido objetivando a disponibilização de laudos de eletrocardiogramas através de dois protocolos: o primeiro com transmissão em tempo real, destinado ao atendimento emergências cardiológicas, e o segundo, com utilização da Internet, para os casos de avaliação cardiológica não emergencial. O SED foi implantado em dois hospitais da cidade de São Lourenço do Sul um localizado na zona rural e outro no centro da cidade, e em um posto de saúde da cidade de Turuçu, ambos no RS. O SED inclui um aparelho digital de ECG, um software de telecomunicação, computadores, uma conexão de modem, linha fixa de telefonia e um telefone celular remoto. A amostra coletada por 1 ano envolveu as três instituições participantes. No total, foram realizados 1063 Tele-ECGs, sendo 622 por transmissão em tempo real e 441 através da internet. No protocolo em tempo real, o tempo médio de transmissão foi de 8,1 (DP ± 1,7) minutos. Os resultados obtidos mostraram que 71,2% (443 de 622) dos ECGs transmitidos em tempo real foram considerados como patológicos, incluindo 66 (14,9%) de ECGs com sinais de alteração isquêmica aguda e 39 ECGs (8,8%) IAM com elevação do segmento S-T. Em decorrência dos resultados descritos e de seu baixo custo, o Sistema de Tele-ECG Digital foi considerado como de grande utilidade para as Instituições de Saúde, beneficiando pequenas cidades, comunidades remotas e áreas rurais do Brasil.
Sujet(s)
Humains , Cardiopathies/diagnostic , Électrocardiographie , Urgences , Internet , Télécommunications , TélémédecineRÉSUMÉ
Este estudo objetiva desenvolver uma técnica alternativa, fidedigna e de custo reduzido ao raio X, para avaliar a postura humana e problemas posturais. O método é baseado em um tipo de técnica de Moiré que usa sombra para definir diferentes padrões de imagens. Foram construídos, testados e comparados três protótipos para padronizar as variáveis importantes inerentes a esta técnica. Testes preliminares realizados com os protótipos 1 e 2 demonstraram suas limitações e conduziram ao desenvolvimento do protótipo final, que possibilitou visualizar a região torácica dorsal do indivíduo com melhor qualidade. A precisão desse terceiro protótipo, realizada através dos cálculos de calibração, apresentou um desvio padrão de 0,051, indicando uma baixa variação entre as franjas. Acredita-se que este estudo motivará o uso desta técnica como alternativa de baixo custo para uso em diferentes avaliações relacionadas à postura humana e doenças associadas.
Sujet(s)
Humains , Mâle , Femelle , Posture , Économies , Topographie de moiréRÉSUMÉ
Este estudo objetivou avaliar o melhor horário de administração da escopolamina, medicamento utilizado na prevenção dos sinais e sintomas da desorientação espacial, e a interação de uma dieta controlada sobre sua ação. Foram realizados testes na cadeira rotatória desenvolvida no Laboratório de Microgravidade/ PUCRS, em 10 voluntários saudáveis. Cada voluntário participou de dois dias de teste, randomizados, um depois de 12h de jejum e no outro após a ingestão de uma dieta padronizada, recebendo, em ambos os dias, a dose oral de 0,45 mg de escopolamina. O teste rotatório foi realizado 60 min, 90 min, 120 min após administração deste medicamento. A sintomatologia da desorientação espacial e os efeitos colaterais do fármaco foram avaliados através do questionário de Graybiel e da avaliação clínica do voluntário durante e após os testes de rotação na cadeira. Os resultados indicaram que não foi possível determinar o melhor horário de administração da escopolamina. No teste realizado a 60 min, a interação com a dieta aumentou o tempo de rotação na cadeira (p = 0,0002). Uma amostra maior e a dosagem séria da escopolamina são necessários para um melhor entendimento de sua ação, seu horário de administração e sua interação com diferentes alimentos.