Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 9 de 9
Filtrer
1.
Arq. bras. cardiol ; Arq. bras. cardiol;109(6): 590-598, Dec. 2017. tab, graf
Article de Anglais | LILACS-Express | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-887987

RÉSUMÉ

Abstract Background: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) remains uncertain. Objective: To evaluate the impact of PVR on mortality and hospital readmission one year after TAVI. Methods: Between January 2009 and June 2015, a total of 251 patients underwent TAVI with three different prostheses at two cardiology centers. Patients were assessed according to PVR severity after the procedure. Results: PVR was classified as absent/trace or mild in 92.0% (n = 242) and moderate/severe in 7.1% (n = 18). The moderate/severe PVR group showed higher levels of aortic calcification (22% vs. 6%, p = 0.03), higher serum creatinine (1.5 ± 0.7 vs. 1.2 ± 0.4 mg/dL, p = 0.014), lower aortic valve area (0.6 ± 0.1 vs. 0.7 ± 0.2 cm2, p = 0.05), and lower left ventricular ejection fraction (49.2 ± 14.8% vs. 58.8 ± 12.1%, p = 0.009). Patients with moderate/severe PVR had more need for post-dilatation (p = 0.025) and use of larger-diameter balloons (p = 0.043). At one year, all-cause mortality was similar in both groups (16.7% vs. 12%, p = 0.08), as well as rehospitalization (11.1% vs. 7.3%, p = 0.915). PVR grade significantly reduced throughout the first year after the procedure (p < 0.01). The presence of moderate/severe PVR was not associated with higher one-year mortality rates (HR: 0.76, 95% CI: 0.27-2.13, p = 0.864), rehospitalization (HR: 1.08, 95% CI: 0.25-4.69, p=0.915), or composite outcome (HR: 0.77, 95% CI: 0.28-2.13, p = 0.613). Conclusion: In this sample, moderate/severe PVR was not a predictor of long-term mortality or rehospitalization. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Resumo Fundamento: O impacto da regurgitação paravalvular (RPV) após implante de valva aórtica transcateter (TAVI) permanece incerto. Objetivo: Analisar o impacto da RPV na mortalidade e re-hospitalização 1 ano após o TAVI. Métodos: Entre janeiro de 2009 e junho de 2015, 251 pacientes foram submetidos ao TAVI em dois centros cardiológicos com 3 diferentes próteses. Os pacientes foram analisados de acordo com a gravidade da RPV pós-procedimento. Resultados: RPV foi classificada como ausente/mínima ou discreta em 92,0% (n=242) dos pacientes e moderada/grave em 7,1% (n = 18). Os pacientes com RPV moderada/importante apresentaram maior grau de calcificação aórtica (22,0% vs. 6,0%; p = 0,03), creatinina sérica (1,53 ± 0,71 vs. 1,18 ± 0,43 mg/dL; p = 0,01), menor área valvar aórtica (0,61 ± 0,12 vs. 0.69 ± 0,17 cm2; p = 0,05) e menor fração de ejeção do ventrículo esquerdo (49,17±14,79% vs. 58,82±12,14%; p = 0,009). Nos pacientes com RPV moderada/importante a necessidade de pós-dilatação foi maior (p = 0,025) e eventualmente com balão de diâmetro maior (p = 0,04). Ao final de 1 ano, a mortalidade por todas as causas foi similar em ambos os grupos (16,7% vs. 12,0%; p = 0,08), assim como re-hospitalização (11,1% vs. 7,3%; p = 0,91). O grau de RPV ao longo do primeiro ano reduziu progressivamente (p < 0,01). A presença de RPV moderada/importante não foi associada a maiores taxas de mortalidade em 1 ano [RR (risco relativo): 0,76; IC (intervalo de confiança) 95%: 0,27-2,13; p = 0,864)], re-hospitalização (RR: 1,08; IC 95%: 0,25-4,69; p = 0,915) ou desfecho combinado (RR: 0,77; IC 95%: 0,28-2,13; p = 0,61). Conclusões: Nesta amostra, a presença de regurgitação paravalvular moderada/importante não foi um preditor de mortalidade ou reinternação a longo prazo. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)

2.
Int. j. cardiovasc. sci. (Impr.) ; 29(1): 76-79, jan.-fev.2016. ilus
Article de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-797115

RÉSUMÉ

A origem anômala da artéria coronária circunflexa do seio de Valsalva direito é a anomalia coronariana mais frequente. Relata-se o caso de uma paciente com artéria circunflexa anômala originada da artéria coronária direita, submetida a cirurgia de troca valvar mitral, evoluindo com choque cardiogênico e oclusão aguda da artéria circunflexa. Foi necessária intervenção coronariana percutânea de emergência e implante de stent não farmacológico. A paciente evoluiu com melhora clínica, sem novas complicações cardíacas...


Anomalous origin of the circumflex coronary artery from the right sinus of Valsalva is the most frequent coronary anomaly. We report the case of a patient with anomalous circumflex artery originating from the right coronary artery, who underwent mitral valve replacement surgery evolving with cardiogenic shock and acute occlusion of the circumflex artery. Emergency percutaneous coronary intervention and bare-metal stent implantation were required. The patient improved clinically without any further cardiaccomplications...


Sujet(s)
Humains , Femelle , Sujet âgé , Angioplastie/méthodes , Valve atrioventriculaire gauche/chirurgie , Vaisseaux coronaires/chirurgie , Malformations/chirurgie , Acide acétylsalicylique/analogues et dérivés , Chirurgie thoracique/méthodes , Intervention coronarienne percutanée/méthodes , Ischémie myocardique/complications , Sinus de l'aorte/malformations , Endoprothèses
3.
Rev. bras. cardiol. invasiva ; 23(4): 251-255, out.-dez. 2015. tab
Article de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-846602

RÉSUMÉ

Introdução: O stent MGuard™, revestido por malha polimérica microscópica, tem a finalidade de reduzir a embolização distal de fragmentos durante a intervenção coronária percutânea (ICP) em enxertos de veia safena (EVS). Avaliamos os desfechos clínicos precoces e tardios de pacientes submetidos à ICP de EVS com stents MGuard™ vs. stents farmacológicos (SF). Métodos: Estudo observacional, retrospectivo, realizado em dois centros terciários, envolvendo uma coorte de pacientes com lesões em EVS, tratados de forma eletiva ou de emergência com stents MGuard™ ou SF. Resultados: Foram incluídos 271 pacientes, sendo 220 tratados com SF. O Grupo MGuard™ apresentou maior proporção de mulheres (25,5% vs. 10,5%; p=0,01), com média de idades de 65,0 ± 13,9 anos vs. 69,0 ± 9,6 anos (p = 0,06). O Grupo SF utilizou com maior frequência filtro de proteção distal (5,8% vs. 10,0%; p = 0,001). Sucesso angiográfico foi obtido na maioria dos casos (96,2% vs. 98,0%; p = 0,22). O Grupo MGuard™ teve menores taxas de eventos cardiovasculares adversos maiores (ECAM) na fase hospitalar que o Grupo SF (1,9% vs. 13,6%; p = 0,01) devido exclusivamente à menor incidência de infarto periprocedimento. Entretanto, a taxa de ECAM em 1 ano foi maior no grupo MGuard™ (14,3% vs. 4,4%; p = 0,01) à custa de maior taxa de revascularização da lesão alvo (7,1% vs. 1,3%; p = 0,048). Conclusões: A utilização de stent MGuard™ resultou em redução de eventos na fase hospitalar, porém, no longo prazo, os SF foram superiores em reduzir desfechos maiores, sobretudo a necessidade de revascularização da lesão alvo


Background: The MGuard™ stent, which has a microscopic polymer mesh coating, is intended to reduce the distal embolization of fragments during percutaneous coronary intervention (PCI) in saphenous vein grafts (SVG). This study evaluated the early and late clinical outcomes of patients undergoing PCI in SVG with MGuard™ stents vs. drug­eluting stents (DES). Methods: Observational, retrospective study conducted at two tertiary centers, involving a cohort of patients with SVG lesions submitted to elective or emergency treatment with MGuard™ stents or DES. Results: A total of 271 patients were included, of whom 220 were treated with DES. The MGuard™ group had a higher proportion of women (25.5% vs. 10.5%; p = 0.01), with a mean age of 65.0 ± 13.9 years vs. 69.0 ± 9.6 years (p = 0.06). The DES group more frequently used distal protection filter (5.8% vs. 10.0%; p = 0.001). Angiographic success was attained in most cases (96.2% vs. 98.0%; p = 0.22). The MGuard™ group had lower rates of early major adverse cardiovascular events (MACE) than the DES group (1.9% vs. 13.6%; p = 0.01), due solely to the lower incidence of periprocedural infarction. However, the MACE rate at 1 year was higher in the MGuard™ group (14.3% vs. 4.4%; p = 0.01) at the expense of a higher rate of target lesion revascularization (7.1% vs. 1.3%; p = 0.048). Conclusions: The use of the MGuard™ stent resulted in a reduction of events during hospitalization; however, in the long term the DES were superior in reducing major outcomes, mainly the need for target lesion revascularization


Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Veine saphène/chirurgie , Endoprothèses , Transplants , Endoprothèses à élution de substances , Héparine/administration et posologie , Acide acétylsalicylique/administration et posologie , Pontage aortocoronarien/méthodes , Coronarographie/méthodes , Études observationnelles comme sujet , Intervention coronarienne percutanée/méthodes , Hospitalisation
4.
Rev. bras. cardiol. invasiva ; 23(3): 183-189, jul.-set.2015. tab, graf
Article de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-794195

RÉSUMÉ

Estudos iniciais mostram que oclusões antigas ou com tempo indeterminado têm sido associadas a insucesso da intervenção coronária percutânea (ICP) e a pior prognóstico. Nosso objetivo foi determinar o impacto do tempo de oclusão no sucesso e nos resultados da ICP contemporânea na obstrução total crônica (OTC). Métodos: Analisamos uma coorte retrospectiva de pacientes consecutivos que realizaram ICP em OTC, e que foram comparados de acordo com o tempo de oclusão confirmado (TOC) < 12 meses, ≥ 12 meses, ou indeterminado (TOI).Resultados: Foram tratados 168 pacientes, 122 (72,6%) com TOC (80 < 12 meses, 42 ≥ 12 meses) e 46(24,7%) com TOI. A extensão da lesão foi de 17,0 ± 13,6 mm, em vasos de 2,90 ± 0,58 mm, e a abordagemanterógrada foi utilizada em 98,8% dos casos. Sucesso angiográfico foi obtido em 79,2% dos pacientes (80,0% vs. 73,8% vs. 82,6%; p = 0,73). A principal causa de insucesso foi a incapacidade de cruzar a lesão com o fio-guia (68,6%). O tempo de oclusão não teve impacto na taxa de eventos cardiovasculares hospitalares (4,8% vs. 7,1% vs. 6,0%; p = 0,73), explicados em sua quase totalidade pelos infartos do miocárdioperiprocedimento, ou nos eventos tardios (18,8% vs. 7,1% vs. 15,3%; p = 0,23). Na análise multivariada,comprimento da lesão ≥ 20 mm (odds ratio - OR = 7,27; intervalo de confiança de 95% - IC 95% 1,94-29,1; p = 0,003), calcificação (OR = 4,72; IC 95% 1,19-19,1; p = 0,02) e tortuosidade do segmento ocluído (OR = 15,98; IC 95% 2,18-144,7; p = 0,007) foram preditores de insucesso. Conclusões: O tempo de oclusão não está associado ao aumento da taxa de insucesso do procedimento ou a piores resultados da ICP em OTC...


Initial studies have shown that old occlusions or those with indeterminate occlusion durationhave been associated with percutaneous coronary intervention (PCI) failure and a worse prognosis. This study aimed to determine the impact of occlusion duration on the success and outcomes of contemporary PCI on chronic total occlusion (CTO). Methods: The authors analyzed a retrospective cohort of consecutive patients submitted to PCI in CTO, who were compared according to the confirmed occlusion duration (COD) < 12 months, ≥ 12 months, orindeterminate occlusion duration (IOD).Results: A total of 168 patients were treated, 122 (72.6%) with COD (80 < 12 months, 42 ≥ 12 months) and 46(24.7%) with an IOD. Lesion extension was 17.0 ± 13.6 mm, in 2.90 ± 0.58 mm vessels, and the anterogradeapproach was used in 98.8% of cases. Angiographic success was attained in 79.2% of patients (80.0% vs. 73.8%vs. 82.6%; p = 0.73). The main cause of failure was the inability to cross the lesion with the guidewire (68.6%).Occlusion duration had no impact on in-hospital events (4.8% vs. 7.1% vs. 6.0%; p = 0.73), which were almostentirely explained by periprocedural myocardial infarction, or on late outcomes (18.8% vs. 7.1% vs. 15.3%;p = 0.23). At the multivariate analysis, lesion length ≥ 20 mm (odds ratio - OR = 7.27; 95% confidence interval- 95% IC 1.94-29.1; p = 0.003), calcification (OR = 4.72; 95% CI 1.19-19.1; p = 0.02), and tortuosity of theoccluded segment (OR = 15.98; 95% CI 2.18-144.7; p = 0.007) were predictors of failure...


Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Maladie des artères coronaires/complications , Maladie des artères coronaires/diagnostic , Intervention coronarienne percutanée/méthodes , Occlusion coronarienne/complications , Occlusion coronarienne/diagnostic , Coronarographie/méthodes , Analyse de variance , Acide acétylsalicylique/administration et posologie , Études de cohortes , Facteurs de risque , Héparine/administration et posologie , Pronostic , Endoprothèses
5.
Rev. bras. cardiol. invasiva ; 23(3): 166-172, jul.-set.2015. tab, ilus, graf
Article de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-794192

RÉSUMÉ

Introdução: Estudos recentes têm demonstrado a eficácia do implante transcateter valve-in-valve para otratamento de disfunção de biopróteses em pacientes de alto risco cirúrgico. Apresentamos nossa experiênciainicial com o implante valve-in-valve.Métodos: Caracterizamos o perfil clínico, ecocardiográfico e do procedimento, e reportamos os resultados de médio prazo de pacientes com disfunção de bioprótese submetidos a implante valve-in-valve em posição aórtica. Resultados: Incluímos sete pacientes do sexo masculino, com idade de 72,6 ± 10,0 anos. O escore STS foi 9,6± 10,5%, e o EuroSCORE logístico foi 22,7 ± 14,7%. Três pacientes apresentavam dupla disfunção; dois tinham insuficiência; e dois exibiam estenose isolada. A via transfemoral foi utilizada em seis casos, e a transapical, em um caso. Os dispositivos implantados incluíram as próteses Sapien XT (n = 5) e CoreValve (n = 2). O sucesso do procedimento foi obtido em seis (85,7%) casos. Após o procedimento, o gradiente médio reduziu-se de 38,2 ± 9,6mmHg para 20,9 ± 5,9 mmHg, e a área valvar elevou-se de 1,2 ± 0,4 cm2 para 1,5 ± 0,5 cm2. Ao final de 1 ano, nãoocorreram óbitos e nem outros desfechos adversos significativos; 80% dos pacientes encontravam-se em classefuncional NYHA I/II. Os gradientes transvalvares e a área valvar permaneceram inalterados nesse período. Conclusões: O procedimento valve-in-valve foi eficaz na maioria dos pacientes de alto risco cirúrgico comdisfunção de bioprótese. Quando realizado em pacientes bem selecionados, resulta em desfechos clínicos e hemodinâmicos satisfatórios.


Background: Recent studies have demonstrated the efficacy of the transcatheter valve-in-valveimplantation for the treatment of bioprosthesis dysfunction in high-risk surgical patients. This study presents the initial experience with valve-in-valve implantation. Methods: Clinical, echocardiographic, and procedural profiles were characterized, and the mid-term results of patients with surgical bioprosthesis dysfunction submitted to valve-in-valve implantation in theaortic position were reported.Results: Seven male patients were included, aged 72.6 ± 10.0 years. The STS score was 9,6 ± 10,5%, andthe logistic EuroSCORE was 22.7 ± 14.7%. Three patients had combined aortic bioprosthesis failure; two had isolated regurgitation; and two had isolated stenosis. The transfemoral access was used in six cases, and the transapical access in one case. Implanted devices included Sapien XT (n = 5) and CoreValve (n = 2) prostheses. Procedural success was achieved in six (85.7%) cases. After the procedure, the mean gradient decreased from 38.2 ± 9.6 mmHg to 20.9 ± 5.9 mmHg, and the valve area increased from 1.2 ±0.4 cm2 to 1.5 ± 0.5 cm2. After 1 year, there were no deaths and no other significant adverse outcomes; 80% of patients were in NYHA functional class I/II. The transvalvular gradients and valve area remained unchanged in this period.


Sujet(s)
Humains , Mâle , Sujet âgé , Bioprothèse , Sténose aortique/diagnostic , Sténose aortique/thérapie , Remplacement valvulaire aortique par cathéter/méthodes , Interprétation statistique de données , Échocardiographie/méthodes , Facteurs de risque , Prothèses et implants/méthodes , Appréciation des risques/méthodes , Traitement médicamenteux/méthodes , Valve aortique/chirurgie , Ventricules cardiaques
6.
Rev. bras. cardiol. invasiva ; 22(4): 394-400, Oct-Dec/2015. graf
Article de Portugais | LILACS | ID: lil-744572

RÉSUMÉ

Em pacientes submetidos à intervenção coronária percutânea, a natureza progressiva da doença coronária aterosclerótica é frequentemente negligenciada. Geralmente, infartos muito tardios (> 1 ano) acometendo o território tratado são atribuídos a complicações relacionadas ao dispositivo. Apresentamos o caso de uma paciente com infarto agudo do miocárdio com supradesnivelamento do segmento ST na parede inferior, que apresentava oclusão trombótica de um stent não farmacológico implantado 8 anos antes. Apesar do diagnóstico angiográfico de trombose muito tardia, a tomografia de coerência óptica revelou que a etiologia foi a ruptura de placa aterosclerótica no leito distal, fora do segmento previamente tratado.


The progressive nature of coronary atherosclerotic disease is often neglected in patients submitted to percutaneous coronary intervention. Very late (> 1 year) myocardial infarctions affecting the treated myocardial territory are usually attributed to device related complications. We report the case of a patient with acute inferior wall ST-elevation myocardial infarction, who had a thrombotic occlusion of a bare-metal stent implanted 8 years before. Despite the angiographic diagnosis of very late stent thrombosis, optical coherence tomography revealed that the acute myocardial infarction was caused by rupture of an atherosclerotic plaque outside of the previously stented segment.


Sujet(s)
Humains , Femelle , Adulte d'âge moyen , Infarctus du myocarde/complications , Endoprothèses , Tomographie par cohérence optique/méthodes , Thrombose coronarienne/complications , Thrombose coronarienne/diagnostic , Maladie des artères coronaires/complications , Électrocardiographie/méthodes , Sténose coronarienne/complications , Intervention coronarienne percutanée/méthodes
7.
Rev. bras. cardiol. invasiva ; 22(3): 300-302, Jul-Sep/2014. graf
Article de Portugais | LILACS-Express | LILACS, SES-SP | ID: lil-732785

RÉSUMÉ

A artéria coronária única é anomalia rara, que pode estar associada à isquemia miocárdica e morte súbita. Apresentamos o caso de uma mulher jovem, com quadro de angina atípica, cujo cateterismo revelou artéria coronária direita que se originava do terço médio da artéria descendente anterior, uma variante da artéria coronária única.


A single coronary artery is a rare anomaly that may be associated with myocardial ischemia and sudden death. We present a case of a young woman with atypical angina whose coronary angiography revealed a right coronary artery originating from the mid left anterior descending artery, a variant of the single coronary artery.

8.
Rev. bras. cardiol. invasiva ; 21(4): 359-366, out.-dez. 2013. graf, tab
Article de Portugais | LILACS, SES-SP | ID: lil-703688

RÉSUMÉ

INTRODUÇÃO: A revascularização percutânea de diabéticos é frequente e a utilização de stents farmacológicos (SF) é desejável, pois estes reduzem a reestenose e a necessidade de nova revascularização. O objetivo desse estudo foi comparar os resultados clínicos de longo prazo entre diabéticos tratados com e sem SF. MÉTODOS: Analisou-se uma coorte consecutiva de diabéticos submetidos à intervenção coronária percutânea (ICP) entre janeiro de 2009 e dezembro de 2012, em hospital terciário da rede pública. Esses pacientes foram acompanhados prospectivamente. RESULTADOS: Avaliamos 939 diabéticos, sendo 359 (38,3%) tratados com SF e 580 (61,7%) tratados com stents não farmacológicos (SNF). A taxa de eventos cardiovasculares adversos maiores (ECAM) em 12,6 ± 3,4 meses foi maior no grupo SNF (9,5% vs. 14,8%; risco relativo - RR = 1,56; intervalo de confiança de 95% - IC 95% 1,07-2,27; P = 0,02), assim como o óbito (2,8% vs. 6,7%; RR = 2,41; IC 95% 1,22-4,77; P < 0,01) e a revascularização do vaso alvo (3,9% vs. 7,2%; RR = 1,85; IC 95% 1,03-3,35; P = 0,04). Não foram observadas diferenças na incidência de infarto do miocárdio (1,7% vs. 0,5%; RR = 0,30; IC 95% 0,07-1,23; P = 0,08) ou acidente vascular encefálico (1,1% vs. 0,2%; RR = 0,15; IC 95% 0,01-1,37; P = 0,07). A análise multivariada revelou que a doença renal crônica (RR = 2,05; IC 95% 1,40-2,98; P < 0,01) e a síndrome coronária aguda (RR = 2,08; IC 95% 1,42-3,02; P < 0,01) foram os únicos preditores independentes de ECAM. CONCLUSÕES: Em pacientes diabéticos não selecionados, a evolução clínica tardia foi pior para os tratados com SNF. Após o ajuste das variáveis de confusão, o uso de SF não se mostrou preditor independente da redução de ECAM.


BACKGROUND: Percutaneous revascularization in diabetic is frequent and the use of drug-eluting stents (DES) is desirable, reducing restenosis and the need for repeat revascularization. The objective of this study was to compare the long-term outcomes of diabetic patients treated with and without DES. METHODS: A consecutive cohort of diabetic patients undergoing percutaneous coronary intervention (PCI) between 01/2009 and 12/2012 in a public tertiary hospital was prospectively followed-up. RESULTS: Nine hundred and thirty-nine diabetic patients (38.3%) treated with DES and 580 (61.7%) treated with bare metal stents (BMS) were evaluated. The rate of major adverse cardiac events (MACE) in 12.6 ± 3.4 months was greater in the BMS group (9.5% vs. 14.8%; RR, 1.56; 95% CI, 1.07-2.27; P = 0.02), as well as death (2.8% vs. 6.7%; RR, 2.41; 95% CI, 1.22-4.77; P < 0.01), and target vessel revascularization (3.9% vs. 7.2%; RR, 1.85; 95% CI, 1.03-3.35; P = 0.04). There were no differences in the incidence of myocardial infarction (1.7% vs. 0.5%; RR, 0.30; 95% CI, 0.07-1.23; P = 0.08) or stroke (1.1% vs. 0.2%; RR, 0.15; 95% CI, 0.01-1.37; P = 0.07). Multivariate analysis indicated that chronic kidney disease (RR, 2.05; 95% CI, 1.40-2.98; P < 0.01) and acute coronary syndrome (RR, 2.08; 95% CI 1.42-3.02; P < 0.01) were the only independent predictors of MACE. CONCLUSIONS: In non-selected diabetic patients the long-term clinical outcome was worse for patients treated with BMS. After adjusting for confounding variables, the use of DES was not an independent predictor of reduced MACE.


Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Diabète/diagnostic , Diabète/thérapie , Maladie des artères coronaires/physiopathologie , Intervention coronarienne percutanée/méthodes , Endoprothèses à élution de substances , Analyse multifactorielle , Analyse de survie , Traitement médicamenteux , Thrombose
9.
São Paulo; s.n; 2011. 111 p. ilus, tab.
Monographie de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1079358

RÉSUMÉ

A dor torácica configura um dos principais motivos de procura pelos serviços médicos de emergência em todo o mundo. São cerca de oito milhões de atendimentos a cada ano nos Estados Unidos da América e quatro milhões no Brasil...


Sujet(s)
Douleur thoracique , Services des urgences médicales , Triage
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE