RÉSUMÉ
Objective To establish a method for determining the dissolution oftorasemide sustained-release tablet in vitro and study the methodology of the determination.The consistency of the in vitro release behavior between self-prepared torasemide sustained-release tablet and original preparation were evaluated by constructed method.Methods HPLC method was applied to detect the cumulative release percentage of self-prepared torasemide sustained-release tablet and original preparation in five kinds of release media (water,0.1 mol/L hydrochloric acid solution,pH 4.5 acetate buffer,pH 6.8 phosphate buffer,and 0.1 mol/L hydrochloric acid solution turn to pH 6.8 phosphate buffer).Similarity factor (f2) was used to evaluate the similarity of release curves.Results There was a good linear relationship between the quality concentration of torasemide and peak area in the range of 1.0-12.0 μg/mL (r =0.9995).Results of precision and stability tests were good,and the RSDs for probational liquid were all lower than 2.0%.The average recovery of accuracy test was 100.04%,and RSD was 0.54% (n =12).The homogeneity of within group of self-prepared preparation met the technical requirement,RSDs of each sampling points in six Dissolution Vessels were lower than 10.0%.The f2 factors of self-prepared torasemide sustained-release tablet and original preparation were 72,60,77,66,and 60 in five kinds of release media.Conclusion The method in the paper is suitable for the release test of torasemide,meanwhile,the self-prepared tablet shows consistent in vitro release behavior with that of the original preparation.
RÉSUMÉ
Objective To establish a method for the determination of 8 heavy metal elements of Pb,Cd,As,Hg,Co,V,Se,Mo in iron dextran by inductively coupled plasma optical emission spectrometry (ICP-OES).Method Through selection of detection wavelengths,optimization of instrument parameters,verification of matrix effect interference and investigation of internal standard for correction of matrix effect interference,the 8 heavy metal elements were analyzed by ICP-OES.Results The recovery rate of the detected elements were increased from 83%-90% to 94%-100%,after correction of matrix effect interference by internal standard method.The accuracy of the method were good.The spiked recoveries of the detected elements were from 94.3% to 101.5%.The precision of the method were good (RSD < 3.5%,n =6).The linearities of the detected elements were good,and the correlation coefficients were all greater than 0.999.The detection limits were from 0.22 to 8.54 ng/mL.The quantization limits were from 0.68 to 25.73 ng/mL.Conclusion The established method was accurate,sensitivity,rapid and reliable,which can be applied to the determination of contents of 8 heavy metal elements in iron dextran.
RÉSUMÉ
Objective To establish a method for the determination of 8 heavy metal elements of Pb,Cd,As,Hg,Co,V,Se,Mo in iron dextran by inductively coupled plasma optical emission spectrometry (ICP-OES).Method Through selection of detection wavelengths,optimization of instrument parameters,verification of matrix effect interference and investigation of internal standard for correction of matrix effect interference,the 8 heavy metal elements were analyzed by ICP-OES.Results The recovery rate of the detected elements were increased from 83%-90% to 94%-100%,after correction of matrix effect interference by internal standard method.The accuracy of the method were good.The spiked recoveries of the detected elements were from 94.3% to 101.5%.The precision of the method were good (RSD < 3.5%,n =6).The linearities of the detected elements were good,and the correlation coefficients were all greater than 0.999.The detection limits were from 0.22 to 8.54 ng/mL.The quantization limits were from 0.68 to 25.73 ng/mL.Conclusion The established method was accurate,sensitivity,rapid and reliable,which can be applied to the determination of contents of 8 heavy metal elements in iron dextran.