Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres








Gamme d'année
1.
Rev. bras. cardiol. invasiva ; 23(2): 124-129, abr.-jun. 2015. tab, graf
Article de Portugais | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-786995

RÉSUMÉ

Introdução: A utilização crescente do implante transcateter de prótese valvar aórtica (TAVI) em pacientes de alto risco, em especial naqueles com disfunção ventricular, justifica uma avaliação mais profunda da seleção e dos resultados do procedimento. Utilizamos nosso banco de dados para caracterizar o perfil dos pacientes e avaliar os resultados do TAVI de acordo com o grau de disfunção ventricular.Métodos: Estudo observacional longitudinal no qual foram incluídos todos os pacientes com estenose aórtica (EAo) grave, submetidos ao TAVI entre 2009 e 2014, e comparados àqueles com fração de ejeção do ventrículo esquerdo (FEVE) ≤ 40% vs. > 40%. Foram avaliados os desfechos de segurança e eficácia em 30dias e 1 ano. Resultados: Dentre os 172 pacientes, 20 (11,6%) apresentavam FEVE ≤ 40%. Esses pacientes eram mais jovens, com maior prevalência de tabagismo, infarto agudo do miocárdio prévio, cirurgia de revascularizaçãomiocárdica, marca-passo definitivo e hipertensão arterial pulmonar. Também se observou, nesse grupo, maior frequência de classes funcionais mais elevadas. O grupo com FEVE ≤ 40% apresentou menor gradiente valvar aórtico médio para área valvar equivalente. As taxas de sucesso do procedimento não diferiram entre os grupos. Não foram observadas diferenças na mortalidade, nos eventos coronarianos, cerebrovasculares, sangramentos, complicações vasculares e disfunção renal aguda no acompanhamento de 30 dias e 1 ano. No grupo FEVE ≤ 40%, a média da FEVE elevou-se de 31,5 para 45,1% 1 ano após o procedimento (p = 0,002).Conclusões: O TAVI em pacientes com EAo grave e FEVE ≤ 40% não aumenta o risco de complicações e estáassociado à melhora da FEVE.


Background: The increasing use of transcatheter aortic valve implantation (TAVI) in high-risk patients, especially those with ventricular dysfunction, justifies further evaluation of the selection and the results of the procedure. A database was used to characterize the profile of patients and evaluate TAVI results according to the degree of ventricular dysfunction.Methods: This was a longitudinal observational study that included all patients with severe aortic stenosis(AoS) submitted to TAVI between 2009 and 2014, comparing those with left ventricular ejection fraction (LVEF) ≤ 40% vs. > 40%. The safety and efficacy outcomes were evaluated at 30 days and 1 year. Results: Of the 172 patients, 20 (11.6%) had LVEF ≤ 40%. These patients were younger, with a higherprevalence of smoking, previous acute myocardial infarction, coronary artery bypass graft surgery, permanent pacemaker, and pulmonary artery hypertension. Higher functional classes were also more often observed in this group. The group with LVEF ≤ 40% had lower mean aortic valve gradient for anequivalent valve area. The procedure success did not differ between groups. There were no differences in mortality in coronary and cerebrovascular events, bleeding, vascular complications, and acute renal failure in the 30 day and 1 year follow-up. In the LVEF ≤ 40% group, the mean LVEF increased from 31.5 to 45.1% 1 year after the procedure (p = 0.002). Conclusions: TAVI in patients with severe AoS and LVEF ≤ 40% does not increase the risk of complications and is associated with LVEF improvement.


Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Sujet âgé de 80 ans ou plus , Dysfonction ventriculaire gauche/physiopathologie , Sténose aortique/physiopathologie , Résultat thérapeutique , Remplacement valvulaire aortique par cathéter/méthodes , Interprétation statistique de données , Acide acétylsalicylique/administration et posologie , Échocardiographie transoesophagienne/méthodes , Échocardiographie/méthodes , Étude d'observation , Prothèses et implants , Pronostic , Débit systolique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE