Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 9 de 9
Filtrer
1.
Article de Chinois | WPRIM | ID: wpr-965578

RÉSUMÉ

@#Abstract:Objective To prepare human monoclonal antibody against spike protein(S protein)of severe acute respiratory syndrome coronavirus 2(SARS⁃CoV⁃2)by using single B cell,and determine its neutralizing activity. Methods Venous blood with high antibody level was collected from people immunized with inactivated SARS⁃CoV⁃2 vaccine(Vero cells) twice,of which peripheral blood mononuclear cells(PBMCs)were isolated by lymphocyte stratified fluid and used to isolate single B cell expressing S protein antibody by magnetic beads coupled with S1 protein. Variable region genes of IgG heavy chain and light chain were amplified by nested PCR after reverse transcription of single B cell,which were connected with CMV promoter,IgG leader sequence,IgG constant region and polyA sequence by overlapping PCR to construct antibody linear expression cassette. Linear expression cassette of the heavy chain and light chain from the same B cell was transfected to HEK293T cells to express human monoclonal antibody of SARS⁃CoV⁃2 S protein. Immunoreactivity was detected by immuno⁃ fluorescence while neutralizing activity by pseudovirus neutralization test. Results A total of 26 monoclonal antibodies against SARS⁃CoV⁃2 S protein were expressed,which showed heavy chain and light chain protein bands of IgG antibody at

2.
Article de Chinois | WPRIM | ID: wpr-994726

RÉSUMÉ

Objective:To evaluate the safety of leadless pacemaker implantation in super-elderly patients.Methods:Eleven patients with average age of 90 (86, 92) years who underwent leadless pacemaker implantation in the Department of Cardiology, Peking University People′s Hospital from March 2021 to May 2022 were included. The clinical data and implantation information were collected. The complications (cardiac tamponade, myocardial infarction, cerebral infarction, pulmonary embolism, pacemaker reinfection, femoral vein hematoma) and death of patients were documented at 24 h, 3 d, and 1, 3, 6 months after pacemaker implantation.Results:There were 9 males and 2 females with the body mass index of 21(19, 23)kg/m 2. The underlying diseases were hypertension, diabetes, coronary heart disease, chronic kidney disease, chronic obstructive pulmonary disease, previous cerebral infarction and moderate to severe tricuspid regurgitation in 9, 9, 9, 6, 4, 4, 4 patients, respectively. The left ventricular ejection fraction was 49% (45%, 52%), the hemoglobin concentration was 118 (114, 122)g/L, 4 patients were taking anticoagulant drugs, and 6 patients were taking antiplatelet drugs. Eight patients were newly implanted with a leadless pacemaker, 2 patients were implanted after removal the old ones, and 1 case was implanted at the same time as removal. The implantation time was 45(40, 47) minutes, the X-ray exposure time was 14 (13, 15) minutes, the release time was 1 (1, 2), the threshold value was 0.50(0.38, 0.75)V/0.24 ms, the impedance was 730 (700, 770) Ω, and the perceived R-wave amplitude 8.2(6.7, 12.8) mV. During the follow-up period of 8 (6, 10) months, no patient had pacemaker dysfunction; and the threshold, R wave sensing, and impedance were stable and maintained within the normal range. No cardiac tamponade, myocardial infarction, cerebral infarction, pulmonary embolism, pacemaker reinfection or death occurred perioperatively and during the follow-up period; 1 patient had hematoma after femoral vein puncture, which improved after compression treatment. Conclusion:This single-center and small-sample study shows that leadless pacemaker implantation is safe for super-elderly patients.

3.
Zhonghua xinxueguanbing zazhi ; (12): 1214-1219, 2022.
Article de Chinois | WPRIM | ID: wpr-969729

RÉSUMÉ

Objective: To analyze the feasibility and safety of bridge therapy with active fixed electrodes connected to external permanent pacemakers (AFLEP) for patients with infective endocarditis after lead removal and before permanent pacemaker implantation. Methods: A total of 44 pacemaker-dependent patients, who underwent lead removal due to infective endocarditis in our center from January 2015 to January 2020, were included. According to AFLEP or temporary pacemaker option during the transition period, patients were divided into AFLEP group or temporary pacemaker group. Information including age, sex, comorbidities, indications and types of cardial implantable electionic device (CIED) implantation, lead age, duration of temporary pacemaker or AFLEP use, and perioperative complications were collected through Haitai Medical Record System. The incidence of pacemaker perception, abnormal pacing function, lead perforation, lead dislocation, lead vegetation, cardiac tamponade, pulmonary embolism, death and newly infection of implanted pacemaker were compared between the two groups. Pneumothorax, hematoma and the incidence of deep vein thrombosis were also analyzed. Results: Among the 44 patients, 24 were in the AFLEP group and 20 in the temporary pacemaker group. Age was younger in the AFLEP group than in the temporary pacemaker group (57.5(45.5, 66.0) years vs. 67.0(57.3, 71.8) years, P=0.023). Male, prevalence of hypertension, diabetes mellitus, chronic renal dysfunction and old myocardial infarction were similar between the two groups (all P>0.05). Lead duration was 11.0(8.0,13.0) years in the AFLEP group and 8.5(7.0,13.0) years in the temporary pacemaker group(P=0.292). Lead vegetation diameter was (8.2±2.4)mm in the AFLEP group and (9.1±3.0)mm in the temporary pacemaker group. Lead removal was successful in all patients. The follow-up time in the AFLEP group was 23.0(20.5, 25.5) months, and the temporary pacemaker group was 17.0(14.5, 18.5) months. In the temporary pacemaker group, there were 2 cases (10.0%) of lead dislocation, 2 cases (10.0%) of sensory dysfunction, 2 cases (10.0%) of pacing dysfunction, and 2 cases (10.0%) of death. In the AFLEP group, there were 2 cases of abnormal pacing function, which improved after adjusting the output voltage of the pacemaker, there was no lead dislocation, abnormal perception and death. Femoral vein access was used in 8 patients (40.0%) in the temporary pacemaker group, and 4 patients developed lower extremity deep venous thrombosis. There was no deep venous thrombosis in the AFLEP group. The transition treatment time was significantly longer in the AFLEP group than in the temporary pacemaker group (19.5(16.0, 25.8) days vs. 14.0(12.0, 16.8) days, P=0.001). During the follow-up period, there were no reinfections with newly implanted pacemakers in the AFLEP group, and reinfection occurred in 2 patients (10.0%) in the temporary pacemaker group. Conclusions: Bridge therapy with AFLEP for patients with infective endocarditis after lead removal and before permanent pacemaker implantation is feasible and safe. Compared with temporary pacemaker, AFLEP is safer in the implantation process and more stable with lower lead dislocation rate, less sensory and pacing dysfunction.


Sujet(s)
Humains , Mâle , Traitement relais , Études de faisabilité , Pacemaker , Endocardite bactérienne/étiologie , Électrodes , Ablation de dispositif
4.
Article de Chinois | WPRIM | ID: wpr-744237

RÉSUMÉ

AIM:To investigate the effect of CUDC-907, a dual histone deacetylase (HDAC) and phosphatidylinositol 3-kinase (PI3K) inhibitor, on the DNA damage, cell cycle distribution and autophagy in human glioma U251cells.METHODS:U251 cells were treated with CUDC-907 of different concentrations, and the cell viability was detected by MTT assay.The quantitativeγ-H2AX foci were determined by laser scanning confocal microscopy.The cell cycle distribution of U251 cells was examined by flow cytometry.The protein expression was determined by Western blot analysis.RESULTS:CUDC-907 inhibited the cell viability and the phosphorylation of Akt and p70 ribosomal protein S6 kinase (p70s6K) in the U251 cells (P<0.05).In CUDC-907-treated cells, the number ofγ-H2AX foci and protein expression ofγ-H2AX were increased significantly (P<0.05).CUDC-907 also induced cell arrest in theM phase by up-regulating the expression of p21, and inhibiting the protein level of cyclin B1 and the phosphorylation of cell division cycle protein2 (Cdc2).In addition, CUDC-907 triggered cell autophagy, and inhibition of autophagy increased CUDC-907-induced DNA damage of U251 cells.CONCLUSION:CUDC-907 significantly inhibits PI3K/Akt signaling pathway, induces DNA damage and arrests cell cycle inM phase.Blockage of autophagy promotes CUDC-907-induced DNA damage of U251cells.

5.
Article de Chinois | WPRIM | ID: wpr-701102

RÉSUMÉ

AIM:To investigate the effect of SCH900776, an inhibitor of checkpoint kinase 1(CHK1), on the proliferation and migration abilities of human glioma U 251 cells.METHODS:The cell viability was detected by MTT assay,and cell proliferation was determined by cell colony formation assay.Cell cycle distribution was analyzed by flow cy-tometry.Wound healing assay was used to determine the cell migration ability.The protein levels were determined by Western blot.RESULTS: SCH900776 inhibited the growth of U251 cells in a dose-dependent manner(P <0.05). SCH900776 treatment substantially induced U251 cell cycle arrest in S and G 2/M phases by decreasing the level of cell di-vision cycle protein 2(Cdc2)and p-Cdc2.Moreover,SCH900776 inhibited the cell migration.Western blot results indi-cated that SCH900776 increased the phosphorylation level of p 38 MAPK and inhibited the activation of Akt.CONCLU-SION:SCH900776 inhibits the proliferation and migration abilities in human U 251 cells by promoting the phosphorylation of p38 MAPK and suppressing the activation of Akt.

6.
Article de Chinois | WPRIM | ID: wpr-664814

RÉSUMÉ

This work aims to analyZe and compare the potential biomarkers between cervical cancer ( CC ) patients and healthy controls (HC).The urine samples of 11 CC patients (age (45.65 ± 5.6) years) and 11 HC patients (age (45.9 ± 3.2) years) were collected.The metabolites of urine samples from CC and HC were analyZed by using ultra performance liquid chromatography coupled with quadrupole orbitrap tandem mass spectrometry ( UHPLC-Q-Orbitrap MS/MS ) , which could provide evidence for early diagnose and disease pathway.The LC-MS data of urines were analyZed by principal components analysis ( PCA) and orthogonal partial least squares discriminant analysis ( OPLS-DA) to identify the potential biomarkers.Urine samples of CC patients were successfully discirminated from those of healthy controls.A total of twelve significant metabolites were found and identified as potential biomarkers according to the established UHPLC-Q-Orbitrap MS and MS/MS method.Identification of biomarkers between CC and HC patients may play an important role in the study of mechanism of UC and its pathway.

7.
Chinese Circulation Journal ; (12): 899-903, 2017.
Article de Chinois | WPRIM | ID: wpr-659946

RÉSUMÉ

Objective:To explore the value of echocardiography for diagnosing infectious endocarditis (IE).Methods:A total of 487 patients with cardiovascular implantable electronic devices (CIED) infection treated in our hospital from 2013-01 to 2015-06 were enrolled.Based on symptoms,blood culture and echocardiography,9 patients with suspected IE were further examined by 18F-FDG PET-CT to confirm their diagnosis and classification.Definitive therapy was conducted and the patients were followed-up for 1 year to confirm the diagnostic accuracy of echocardiography on CIED induced IE.Results:3 patients were preliminarily diagnosed for bacteremia since no vegetation was found by echocardiography,while IE was finally diagnosed by PET-CT.2 patients were preliminarily diagnosed for IE by echocardiography presented valvular vegetation,while PET-CT showed no evidence of vegetation;then one of them was diagnosed as bacteremia by positive blood culture and another was diagnosed as non-infection.4 patients were preliminarily diagnosed for IE by echocardiography indicated existing vegetation after CIED lead extraction,while PET-CT demonstrated no infection sign in heart chamber and the finally diagnosed was as "non-infectious fibrous residual tissue".According to final diagnosis,definitive therapies were performed to specific patients with at least 1 year follow-up study,no one had new and recurrent infection.Conclusion:Echocardiography had deficiency for diagnosing vegetation in heart chamber especially in suspicious IE patients after CIED lead extraction.It is necessary to make accurate diagnosis with other method for guiding appropriate therapy.

8.
Chinese Circulation Journal ; (12): 899-903, 2017.
Article de Chinois | WPRIM | ID: wpr-662391

RÉSUMÉ

Objective:To explore the value of echocardiography for diagnosing infectious endocarditis (IE).Methods:A total of 487 patients with cardiovascular implantable electronic devices (CIED) infection treated in our hospital from 2013-01 to 2015-06 were enrolled.Based on symptoms,blood culture and echocardiography,9 patients with suspected IE were further examined by 18F-FDG PET-CT to confirm their diagnosis and classification.Definitive therapy was conducted and the patients were followed-up for 1 year to confirm the diagnostic accuracy of echocardiography on CIED induced IE.Results:3 patients were preliminarily diagnosed for bacteremia since no vegetation was found by echocardiography,while IE was finally diagnosed by PET-CT.2 patients were preliminarily diagnosed for IE by echocardiography presented valvular vegetation,while PET-CT showed no evidence of vegetation;then one of them was diagnosed as bacteremia by positive blood culture and another was diagnosed as non-infection.4 patients were preliminarily diagnosed for IE by echocardiography indicated existing vegetation after CIED lead extraction,while PET-CT demonstrated no infection sign in heart chamber and the finally diagnosed was as "non-infectious fibrous residual tissue".According to final diagnosis,definitive therapies were performed to specific patients with at least 1 year follow-up study,no one had new and recurrent infection.Conclusion:Echocardiography had deficiency for diagnosing vegetation in heart chamber especially in suspicious IE patients after CIED lead extraction.It is necessary to make accurate diagnosis with other method for guiding appropriate therapy.

9.
Article de Chinois | WPRIM | ID: wpr-243436

RÉSUMÉ

<p><b>OBJECTIVE</b>To investigate the effects of serotonin (5-HTIA) receptors in the hippocampal dentate gyrus (DG) on active avoidance learning in rats.</p><p><b>METHODS</b>Totally 36 SD rats were randomly divided into control group, antagonist group and agonist group(n = 12). Active avoidance learning ability of rats was assessed by the shuttle box. The extracellular concentrations of 5-HT in the DG during active avoidance conditioned reflex were measured by microdialysis and high performance liquid chromatography (HPLC) techniques. Then the antagonist (WAY-100635) or agonist (8-OH-DPAT) of the 5-HT1A receptors were microinjected into the DG region, and the active avoidance learning was measured.</p><p><b>RESULTS</b>(1) During the active avoidance learning, the concentration of 5-HT in the hippocampal DG was significantly increased in the extinction but not establishment in the conditioned reflex, which reached 164.90% ± 26.07% (P <0.05) of basal level. (2) The microinjection of WAY-100635 (an antagonist of 5-HT1A receptor) into the DG did not significantly affect the active avoidance learning. (3) The microinjection of 8-OH-DPAT(an agonist of 5-HT1A receptor) into the DG significantly facilitated the establishment process and inhibited the extinction process during active avoidance conditioned reflex.</p><p><b>CONCLUSION</b>The data suggest that activation of 5-HT1A receptors in hipocampal DG may facilitate active avoidance learning and memory in rats.</p>


Sujet(s)
Animaux , Rats , 7-Dipropylamino-5,6,7,8-tétrahydro-1-naphtol , Pharmacologie , Apprentissage par évitement , Gyrus denté , Physiologie , Pipérazines , Pharmacologie , Pyridines , Pharmacologie , Rat Sprague-Dawley , Récepteur de la sérotonine de type 5-HT1A , Physiologie , Sérotonine , Physiologie , Agonistes des récepteurs de la sérotonine , Pharmacologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE