RÉSUMÉ
Objective: To compare the isothermal molecular screening techniques CPA and RT-LAMP, against the gold standard test, reverse transcription quantitative polymerase chain reaction (RT-qPCR), and to determine its agreement. Materials and Methods: Paired comparative case-control study. For the evaluation of the CPA method, 70 cases and 130 controls were used, while for RT-LAMP, 30 cases and 70 controls were used. The sensitivity and specificity of both tests were calculated. Subsequently, the bias-corrected Kappa index was calculated by resampling. Results: Both techniques have adequate and equivalent values of sensitivity (RT-LAMP: 82.8%, CPA: 83%) and specificity (RT-LAMP and CPA: 91.5%), as well as a high concordance (88%), and Kappa-index (0.72). Conclusion: Both isothermal molecular screening techniques are suitable for SARS-CoV-2 screening, with a similar sensitivity and specificity.
Objetivo : Comparar las técnicas de cribado molecular isotérmico CPA y RT-LAMP, frente a la prueba de referencia, la reacción en cadena de la polimerasa cuantitativa de transcripción inversa (RT-qPCR), y determinar su concordancia. Materiales y métodos : Estudio comparativo de casos y controles emparejados. Para la evaluación del método CPA se utilizaron 70 casos y 130 controles, mientras que para la RT-LAMP se utilizaron 30 casos y 70 controles. Se calcularon la sensibilidad y la especificidad de ambas pruebas. Posteriormente, se calculó el índice Kappa corregido por sesgo mediante un nuevo muestreo. Resultados: Ambas técnicas presentan valores adecuados y equivalentes de sensibilidad (RT-LAMP: 82,8 %, CPA: 83 %) y especificidad (RT-LAMP y CPA: 91,5 %), así como una alta concordancia (88 %), y un índice Kappa (0,72). Conclusiones: Ambas técnicas de cribado molecular isotérmico son adecuadas para el cribado del SARS-CoV-2, con una sensibilidad y especificidad similares.