RÉSUMÉ
Background@#Remdesivir is a US Food and Drug Administration-approved drug for coronavirus disease 2019 (COVID-19). Clinical trials were conducted under strictly controlled situations for a selected population, and their reported adverse events may not fully represent conditions in real-world patients. We aimed to estimate the incidence of adverse drug events (ADEs) associated with remdesivir in hospitalized patients with COVID-19, including vulnerable subpopulations, such as those with impaired renal or hepatic function and pregnant women. @*Methods@#This retrospective observational study included hospitalized patients with confirmed COVID-19 treated with remdesivir between January and December 2021 at ten hospitals. ADEs and severe ADEs (Common Toxicity Criteria for Adverse Events grade ≥ 3) were operationally defined and analyzed through laboratory investigations. The incidence of ADEs was compared with that of each matched control in subpopulations with renal or hepatic impairment and pregnant women. @*Results@#Among 2,140 patients, 1,416 (66.2%) and 295 (13.8%) experienced at least one ADE and severe ADE, respectively. The most frequent ADE was 'hepatic injury' (42.9%), followed by anemia (27.6%). The most common severe ADEs were 'hypokalemia' (5.3%), 'hepatic injury' (2.9%), and 'anemia' (3.6%). There was no significant difference in the incidence of ADEs in patients relative to their respective matched-control groups, including those with renal impairment (80.0% vs. control 71.8%, P = 0.063), hepatic impairment (70.4% vs. control 75.0%, P = 0.623) and pregnant women (78.6% vs. control 63.7%, P = 0.067). However, severe ADE incidence was significantly higher in patients with renal impairment (40.8% vs. 16.0%, P < 0.001). The most common severe ADEs in those were 'anemia' (15.3%), 'hypokalemia' (10.5%), and 'thrombocytopenia' (8.9%). There was no statistically significant difference in the incidence of severe ADEs in patients with hepatic impairment or in pregnancy (P = 0.230; P = 0.085). @*Conclusion@#A significant proportion of patients with COVID-19 treated with remdesivir experienced ADEs and severe ADEs. Given the high incidence of severe ADEs, caution is required in patients with renal impairment. Further studies are needed to investigate ADEs in pregnant women and patients with hepatic impairment.
RÉSUMÉ
Background@#Accurate measurement of glycated hemoglobin (HbA1c) is crucial for a diabetes diagnosis and subsequent patient management. The detection method and presence of variant Hb can interfere with HbA1c measurements. We evaluated the HbA1c-measuring performance of the DxC 700 AU (Beckman Coulter, Brea, CA, USA) immunoassay-based device in comparison with another immunoassay device and the reference method. @*Methods@#A total of 120 normal and 14 variant Hb samples were analyzed using the Cobas c 513 (Roche Diagnostics, Mannheim, Germany) and DxC 700 AU analyzers. Variant Hb samples were also analyzed using the reference method, along with 20 normal samples. The accuracy, precision, linearity, and carryover were determined. @*Results@#DxC 700 AU results strongly correlated with those of Cobas c 513 and exhibited accuracy in comparison with the reference method. The within-run, between-run, between-day, and total imprecision (%CV) values for the low- and high-concentration control materials were below 2%. The results of DxC 700 AU were linear over a wide HbA1c range (3.39%–18.30%). Although DxC 700 AU performed well in the presence of variant Hb, the HbA1c concentration was underestimated in the presence of fetal Hb. The possibility of interference from a high HbH proportion could not be ruled out. @*Conclusions@#The overall analytical performance of DxC 700 AU was acceptable. The device is accurate, precise, and linear over a wide HbA1c concentration range. Although DxC 700 AU results highly correlated with those of Cobas c 513, caution should be exercised in cases of high HbF and HbH concentrations.
RÉSUMÉ
Background@#Despite the superiority of non-HDL cholesterol (non-HDL-C) and apolipoprotein B (ApoB) as lipid markers for atherosclerotic cardiovascular disease (ASCVD), these are only suitable as secondary markers. We compared LDL cholesterol (LDL-C), non-HDL-C, and ApoB concentrations with respect to the occurrence of cardiovascular disease in adults enrolled in the Korean Genome and Epidemiology Study (KoGES). @*Methods@#We used information on age; sex; medical history; family history of ASCVD; current lipid-lowering therapy; current smoking status; and creatinine, total cholesterol, HDL-C, LDL-C, triglyceride, and ApoB concentrations from 5,872 KoGES participants without ASCVD. New ASCVD development was monitored during the 8-year follow-up period. Adjusted hazard ratios (aHRs) for ASCVD of LDL-C, non-HDL-C, and ApoB concentrations were calculated based on the multivariate Cox regression analyses. The participants were also grouped as low and high according to the median values for each lipid marker, and calculated aHRs of each group combined by two lipid makers. @*Results@#ApoB showed the highest aHR per 1-SD for ASCVD (1.26; 95% confidence interval [CI], 1.11–1.43), followed by non-HDL-C (1.25; 95% CI, 1.11–1.41) and LDL-C (1.20; 95% CI, 1.06–1.37). The group with low LDL-C and high ApoB concentrations had a significantly higher aHR for ASCVD (1.61; 95% CI, 1.05–2.48) compared to the reference group values (low LDL-C and low ApoB concentrations). The aHR for the group with high LDL-C and low ApoB concentrations was not significant (1.30; 95% CI, 0.79–2.16). @*Conclusions@#ApoB, non-HDL-C, and LDL-C are independent risk factors for ASCVD. Increases in the aHR per 1-SD for ASCVD were more strongly affected by ApoB, followed by non-HDL-C and LDL-C. Participants with low LDL-C and high ApoB concentrations showed increased ASCVD risk. For individuals with ASCVD risk factors, even those presenting normal LDL-C concentrations, measuring ApoB concentrations can provide useful information for better evaluation of ASCVD risk.
RÉSUMÉ
Background@#Detection of anti-human leukocyte antigen (HLA) antibodies is important during the selection of an appropriate donor prior to organ transplantation and also for monitoring the patients after transplantation. In this study, we compared antibodies detected via C3d assays, which monitors C3d complement-binding activities of HLA antibodies with those detected via single antigen bead (SAB) assays. @*Methods@#A total of 66 serum samples were tested in parallel by SAB assays (Immucor Transplant Diagnostics, USA) and C3d assays (Immucor) for the detection of HLA class II antibodies. The relationship between these two methods was analyzed based on the types, numbers, median fluorescent intensity (MFI) values, and positivity of the antibodies using MATCH IT! Antibody (Immucor) program. @*Results@#The number of antibodies obtained based on SAB and C3d assays was the highest with 24 samples (36.4%) in the 11–20 range and 23 (34.8%) in the 2–5 range detected via each assay. Among the SAB-positive antibodies, only 28 (6.4%) of the 440 antibodies with MFI ≤3,000 were C3d-positive, and 341 (61.3%) of the 556 antibodies with MFI ≥3,001 were C3d-positive. Whereas, among the 442 C3d-positive antibodies, SAB assays were positive except for 32 (7.2%) and 41 (9.3%) antibodies in the sections of MFI ≤500 and 1,001 ≤MFI ≤10,000, respectively. C3d-positive samples had higher maximum MFI values based on SAB assays, compared with C3d-negative samples. @*Conclusions@#MFI values of HLA class II antibodies detected through SAB assays in C3d-positive samples were higher than those in C3d-negative samples.
RÉSUMÉ
Background@#Pheochromocytoma and paragangliomas (PPGL) are known as tumors with the highest level of heritability, approximately 30% of all cases. Clinical practice guidelines of PPGL recommend genetic testing for germline variants in all patients. In this study, we used whole exome sequencing to identify novel causative variants associated with PPGL to improve the detection of rare genetic variants in our cohort. @*Methods@#Thirty-six tested negative for pathogenic variants in previous Sanger sequencing or targeted gene panel testing for PPGL underwent whole exome sequencing. Whole exome sequencing was performed using DNA samples enriched using TruSeq Custom Enrichment Kit and sequenced with MiSeq (Illumina Inc.). Sequencing alignment and variant calling were performed using SAMtools. @*Results@#Among previously mutation undetected 36 patients, two likely pathogenic variants and 13 variants of uncertain significance (VUS) were detected in 32 pheochromocytoma-related genes. SDHA c.778G>A (p.Gly260Arg) was detected in a patient with head and neck paraganglioma, and KIF1B c.2787-2A>C in a patient with a bladder paraganglioma. Additionally, a likely pathogenic variant in BRCA2, VUS in TP53, and VUS in NFU1 were detected. @*Conclusion@#Exome sequencing further identified genetic alterations by 5.6% in previously mutation undetected patients in PPGL. Implementation of targeted gene sequencing consisted of extended genes of PPGL in routine clinical screening can support the level of comprehensive patient assessment.
RÉSUMÉ
Purpose@#The aim of this study was to evaluate the diagnostic image quality of low dose abdominal digital radiography processed with a new post-processing technique. @*Materials and Methods@#Abdominal radiographs from phantom pilot studies were post-processed by the novel and conventional post-processing methods of our institution; the proper dose for the subsequent patient study of 49 subjects was determined by comparing image quality of the two preceding studies. Two radiographs of each patient were taken using the conventional and derived dose protocols with the proposed post-processing method. The image details and quality were evaluated by two radiologists. @*Results@#The radiation dose for the patient study was derived to be half of the conventional method. Overall half-dose image quality with the proposed method was significantly higher than that of the conventional method (p < 0.05) with moderate inter-rater agreement (κ = 0.60, 0.47). @*Conclusion@#By applying the new post-processing technique, half-dose abdominal digital radiography can demonstrate feasible image quality compared to the full-dose images.
RÉSUMÉ
Plasma exchange performed with the aid of acid-citrate-dextrose formula A (ACD-A) is generally regarded as safe. However, unfractionated heparin (UFH) can serve as an anticoagulant for patients experiencing serious side effects such as anaphylaxis. No guidelines have currently been defined for the stand-alone UFH dosing during plasma exchange. We describe here two patients who developed anaphylaxis to ACD-A during plasma exchange, and we successfully used UFH as a standalone anticoagulant. The first patient was a 55-year-old man who required plasma exchange before ABO-incompatible kidney transplantation. During plasma exchange, he developed an allergic reaction. Thereafter, UFH was used as a standalone anticoagulant during four sessions of plasma exchange; the UFH (5,000 units) was added to a 500 mL normal saline bag and the UFH:whole blood ratio was maintained at 1:28. The second patient was an 80-year-old woman with steroid pulse-resistant neuromyelitis optica. She developed an allergic reaction during the first session of plasma exchange. The patient subsequently underwent five successful sessions of plasma exchange using UFH as a standalone anticoagulant. These findings may be useful when establishing a protocol for UFH as a standalone anticoagulant during plasma exchange in patients who develop an allergic reaction to citrate.
RÉSUMÉ
Background@#Detection of anti-human leukocyte antigen (HLA) antibodies is important during the selection of an appropriate donor prior to organ transplantation and also for monitoring the patients after transplantation. In this study, we compared antibodies detected via C3d assays, which monitors C3d complement-binding activities of HLA antibodies with those detected via single antigen bead (SAB) assays. @*Methods@#A total of 66 serum samples were tested in parallel by SAB assays (Immucor Transplant Diagnostics, USA) and C3d assays (Immucor) for the detection of HLA class II antibodies. The relationship between these two methods was analyzed based on the types, numbers, median fluorescent intensity (MFI) values, and positivity of the antibodies using MATCH IT! Antibody (Immucor) program. @*Results@#The number of antibodies obtained based on SAB and C3d assays was the highest with 24 samples (36.4%) in the 11–20 range and 23 (34.8%) in the 2–5 range detected via each assay. Among the SAB-positive antibodies, only 28 (6.4%) of the 440 antibodies with MFI ≤3,000 were C3d-positive, and 341 (61.3%) of the 556 antibodies with MFI ≥3,001 were C3d-positive. Whereas, among the 442 C3d-positive antibodies, SAB assays were positive except for 32 (7.2%) and 41 (9.3%) antibodies in the sections of MFI ≤500 and 1,001 ≤MFI ≤10,000, respectively. C3d-positive samples had higher maximum MFI values based on SAB assays, compared with C3d-negative samples. @*Conclusions@#MFI values of HLA class II antibodies detected through SAB assays in C3d-positive samples were higher than those in C3d-negative samples.
RÉSUMÉ
Background@#Pheochromocytoma and paragangliomas (PPGL) are known as tumors with the highest level of heritability, approximately 30% of all cases. Clinical practice guidelines of PPGL recommend genetic testing for germline variants in all patients. In this study, we used whole exome sequencing to identify novel causative variants associated with PPGL to improve the detection of rare genetic variants in our cohort. @*Methods@#Thirty-six tested negative for pathogenic variants in previous Sanger sequencing or targeted gene panel testing for PPGL underwent whole exome sequencing. Whole exome sequencing was performed using DNA samples enriched using TruSeq Custom Enrichment Kit and sequenced with MiSeq (Illumina Inc.). Sequencing alignment and variant calling were performed using SAMtools. @*Results@#Among previously mutation undetected 36 patients, two likely pathogenic variants and 13 variants of uncertain significance (VUS) were detected in 32 pheochromocytoma-related genes. SDHA c.778G>A (p.Gly260Arg) was detected in a patient with head and neck paraganglioma, and KIF1B c.2787-2A>C in a patient with a bladder paraganglioma. Additionally, a likely pathogenic variant in BRCA2, VUS in TP53, and VUS in NFU1 were detected. @*Conclusion@#Exome sequencing further identified genetic alterations by 5.6% in previously mutation undetected patients in PPGL. Implementation of targeted gene sequencing consisted of extended genes of PPGL in routine clinical screening can support the level of comprehensive patient assessment.
RÉSUMÉ
An osteoma of the tongue is a rare benign tumor, typically located in the posterior one-third of the tongue. Several etiological hypotheses have been proposed in previous literature reviews. Herein, we report the case of a lingual osteoma in a 39-year-old woman, who complained of a lump in the throat. The lesion presented as a homogeneously hyperdense submucosal mass without any enhancement in the base of the tongue on CT, consistent with previous image findings of lingual osteoma. After surgical resection, the mass was pathologically proven to be a lingual osteoma. The patient no longer complained of the sensation of a lump. Typical CT findings of a lingual osteoma—a well-circumscribed hyperdense submucosal mass seen around the foramen cecum—could be helpful in the diagnosis of lingual osteoma and the prevention of further unnecessary work-up.
RÉSUMÉ
Staphylococcus pettenkoferi is a coagulase-negative staphylococci (CoNS) of growing concern. As CoNS could be an important cause of infections in hospitalized patients, especially in immunocompromised patients, accurate identification is critical to timely and effective treatment. In the past, S. pettenkoferi was not identifed by conventional methods or was misidentified as another Staphylococcus species or another genus. To the best of our knowledge, this is the first case of S. pettenkoferi identified using Vitek MS (bioMérieux, France). Two patients admitted to our hospital were confirmed to have bacteremia caused by S. pettenkoferi, which was identified in blood cultures using Vitek MS (bioMérieux). Therefore, we recommend using the Vitek MS (bioMérieux) for rapid and accurate identification of the pathogen causing bloodstream infection when CoNS is suspected.
Sujet(s)
Humains , Bactériémie , Sujet immunodéprimé , StaphylococcusRÉSUMÉ
Arteriovenous malformation (AVM) is a lesion involving a high-flow vascular malformation, which is one of the causes of massive gastrointestinal bleeding. In the pediatric population, AVM is quite rare in the gastrointestinal tract, and the most common primary site is the colon. A small bowel is a rare primary site of AVM, and only 1 case has been reported in Korea. Here, we report on a case of AVM found in the distal ileum of a 14-year-old girl who complained about recurrent lower abdominal pain only without a gastrointestinal hemorrhage. In the previous research literature, a small bowel AVM can be diagnosed through detecting the existence of an enhancing nidus of the intestinal wall at the arterial phase, accompanied by an early draining vein as it appeared on a dynamic contrast-enhanced abdominal computed tomography. In our case, the pathologically confirmed AVM of the distal ileum showed a dot-like enhancement within the thick low-attenuating submucosal layer of the terminal ileum.
RÉSUMÉ
Occult breast cancer (OBC) is an asymptomatic condition. We report a case of OBC in a 72-year-old male patient who presented with severe dyspnea and upper extremity swelling. Computed tomography scan showed multiple lymph node enlargements in the supraclavicular and infraclavicular areas, and ultrasound scan showed multiple axillary lymph node enlargements. Based on the radiological findings, clinicians suspected lymphoma or disseminated metastasis from unknown primary malignancies. However, the axillary biopsy specimen revealed invasive breast cancer with hormonal receptor positivity.