RÉSUMÉ
Objective To investigate the effect of 100 kVp low tube voltage combined with adaptive statistical iterative reconstruc-tion-Veo(ASIR-V)on the imaging display,image quality and radiation dose of Adamkiewicz artery(AKA).Methods Ninety patients with computed tomography angiography(CTA)of aorta were randomly divided into two groups.In group A,the tube voltage was 100 kVp,and ASIR-V was 80%reconstructed.The tube voltage in group B was 120 kVp,and adaptive statistical iterative recon-struction(ASIR)was 40%reconstructed.The CT value and the standard deviation(SD)value of descending aorta were measured at the 12th thoracic vertebra level,and the CT value and the SD value of the spinal cord were measured at the same level to calculate the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of AKA.According to the continuity between AKA and intercostal artery or lumbar artery,the visualization of AKA was evaluated by two doctors with a double-blinded method and a five-point method,and the radiation doses of group A and group B were compared.Results Compared with group B,the CT value of aorta in group A was sig-nificantly increased by about 22.83%(P<0.001).The background noise of AKA in group A was significantly lower than that in group B(P<0.001),and the SNR and CNR were significantly higher than those in group B(P<0.001).The visualization score of AKA in group A was higher than that in group B(P<0.05).The effective dose(ED)in group A was significantly lower than that in group B by about 41.28%(P<0.001).Conclusion 100 kVp combined with ASIR-V technique for spinal cord AKA imaging can obtain better image quality,improve the sensitivity of AKA display and reduce the radiation dose.