Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 29
Filtrer
Plus de filtres








Gamme d'année
1.
Article de Anglais | WPRIM | ID: wpr-1002887

RÉSUMÉ

The occlusal treatment including prosthetic treatment should be considered when the pathologic symptom was observed with the excessive discrepancy between the centric relation occlusion (CRO) and the maximum intercuspal position (MIP). Through careful diagnosis, the malocclusion and interarch relationship can be analyzed, and occlusal adjustment, restorative treatment, orthodontic therapy, or orthognathic surgery can be performed depending on the degree of disharmony. The patient in this case report complained the unstable occlusion and loss of masticatory function that had been occurring for several years. At the time of the visit, the patient showed severe occlusal disharmony, with only the upper right second molar contacting the lower jaw at the maximum intercuspal position. Based on the analysis of the occlusion, it was difficult to solve the problem with just occlusal adjustment or restorative treatment. In addition, the patient had the skeletal class II malocclusion between the upper and lower jaws. Therefore, for resolving the severe skeletal class II malocclusion, pre- and post-orthodontic treatment, bilateral sagittal split ramus osteotomy (BSSRO) was performed. After that, the occlusal adjustment was performed for stable occlusion, and the missing teeth area was restored with dental implants. During the follow-up period, a periodic follow-up visits and additional occlusal adjustments were performed to achieve a stable centric occlusion and harmonious anterior and lateral guidance. As a result, the final prosthodontic treatment was completed, and the patient’s masticatory function was restored.

2.
Article de Anglais | WPRIM | ID: wpr-914927

RÉSUMÉ

Patients who went through maxillectomy can have severely impaired swallowing, mastication, and pronunciation functions because of palatal defects. Leakage occurs through the nasal cavity while eating, chewing becomes difficult due to the loss of teeth and alveolar ridges, and oral and nasal passages are not separated, leading to hyper-nasal sound, and significantly reducing the quality of life. To prosthetically reconstruct the defect, the weight of the obturator should be reduced as much as possible to minimize dropout because of gravity, and the bulb of the obturator should be properly extended into the defect to get additional retention and stability. In this case of a partially edentulous patient who underwent additional maxillary resection because of tumor recurrence, a metal framework was designed by applying the basic design principles of removable partial dentures. An obturator with improved retention, stability, and support was fabricated through functional impressions. The patient was satisfied with the improved facial expression, mastication, swallowing, and pronunciation, and showed stable occlusion and oral hygiene management during the follow-up period.

3.
Article de Anglais | WPRIM | ID: wpr-918867

RÉSUMÉ

Full-mouth rehabilitation with increasing vertical dimension can be used for patients with severely worn teeth. In severely worn teeth also, the alveolar process can be elongated to compensate for the reduced vertical dimension, and the patient’s vertical dimension of occlusion can be kept constant. However, full-mouth rehabilitation with increasing vertical dimension must be carefully chosen, because the vertical dimension can be reduced by tooth wear. It is important to establish a treatment plan with the systematic diagnosis of the change in the vertical dimension and gain space for the prosthesis. It is necessary to change the vertical dimension to secure the restoration space and select the minimum vertical dimension elevation for the esthetic and functional goal. In this case report, the patient complained of difficulty during chewing due to a worn dentition and wanted esthetic improvement of the short mandibular anterior teeth. After systematic evaluation and diagnosis, we performed full-mouth rehabilitation with minimum vertical dimension elevation to obtain the space for restoration. This resulted in a stable and harmonious occlusion, and the functional and esthetic problems of the patient were solved after treatment. The patient was satisfied with the results of the treatment and maintained stable occlusion during the follow-up period.

4.
Article de Anglais | WPRIM | ID: wpr-875392

RÉSUMÉ

Based on rapid improvement in digital fields, many advanced digital technologies are utilized in prosthodontic treatment. Especially, intraoral scanners and 3D printing technology are commonly used, and facial scanning technology is recently being attempted to be part of these digital routines. This case report aims to introduce a digital procedure using the intraoral scanner, facial scanner, and 3D printing technology to create definitive restorations, which are esthetic and harmonious with patient’s face. From thoroughly evaluated full-mouth provisional restoration which was manufactured and fitted conventionally, definitive prostheses were fabricated using various digital technique. Stable occlusion with functionally and aesthetically satisfying results were achieved.

5.
Article de 0 | WPRIM | ID: wpr-835723

RÉSUMÉ

Prosthodontic decision and management should be considered the patient’s aesthetic need for anterior teeth in maxillary edentulism. This case report describes 10-year clinical outcome of a maxillary edentulous patient was rehabilitated by means of an implant-supported fixed dental prosthesis (ISFDP) for the anterior region and a distal-extension removable partial denture (RPD) for the posterior region. The ISFDP was designed to splint 4 endosseous implants as one unit and engaged by the RPD. The edentulous mandible was restored by means of an implant-supported overdenture. Over the course, no major adverse event occurred other than wear, discoloration, and breakage of resin veneers and artificial teeth.

6.
Article de Coréen | WPRIM | ID: wpr-761457

RÉSUMÉ

A patient who went through maxillectomy can have soft palate defects including oronasal fistulas and suffer from dysphagia and dysarthria due to velopharyngeal insufficiency. This defect causes the food to enter nasal cavity and creates hypernasal sound which debilitates a quality of life. An obturator can rehabilitate the substantial oral tissue defects. The maxillary obturator separates the nasopharynx from the oropharynx during speech and deglutition by closing of the defect. For edentulous obturator patient, it is difficult to obtain proper retention due to reduced peripheral sealing. Therefore, the contours of the defects must be used to maximize the retention, stability, and support. Hollow type obturator can improve physiologic function by reducing weight than the traditional obturator. This case report describes a patient with hemi-maxillectomy who recovers mastication, speech, deglutition, and appearance with a maxillary obturator using physiological border molding of the velopharyngeal area and double-processing method.


Sujet(s)
Humains , Déglutition , Troubles de la déglutition , Dysarthrie , Fistule , Champignons , Mastication , Prothèse maxillofaciale , Méthodes , Fosse nasale , Partie nasale du pharynx , Partie orale du pharynx , Obturateurs palatins , Palais mou , Qualité de vie , Réadaptation , Insuffisance vélopharyngée
7.
Article de Anglais | WPRIM | ID: wpr-222969

RÉSUMÉ

Implant supported removable partial denture (ISRPD) using the implants enables favorable rehabilitation by complementing biomechanical limitations of the conventional removable partial denture (RPD). However, continuous recall check is necessary for evaluation of the mechanical and biological complications to ensure good long-term prognosis of ISRPD. This clinical report describes the complication and management in patient of Kennedy class I edentulism with ISRPD using healing abutment. The wear and fracture of healing abutment occurred at 36 months after delivery. So, healing abutment was replaced by connecting Locator® abutment for altering into the implant retained partial overdenture.


Sujet(s)
Humains , Protéines du système du complément , Overdenture , Prothèse dentaire partielle amovible , Pronostic , Réadaptation
8.
Article de Coréen | WPRIM | ID: wpr-171201

RÉSUMÉ

When an implant-supported maxillary full-arch fixed prosthesis is planned for patients with the horizontal and vertical bone resorption induced by periodontal disease, it is necessary to consider the masticatory function, esthetics and phonetics when placing implants. For this reason, thorough clinical and radiological diagnosis is necessary. Extensive bone and soft tissue grafting may be required as well. Since there is no clear guideline for proper number of implants, segment or splinting of substructure and method of retaining prosthesis, these should be considered during diagnostic process. This clinical report describes a patient who has experienced several tooth extractions and periodontal treatment due to severe periodontitis on maxilla and mandible. With bone and soft tissue graft before dental implant placement, the patient have satisfactory result in esthetic and functional aspect with the implant-supported maxillary full-arch fixed prosthesis opposing mandibular natural dentition.


Sujet(s)
Humains , Résorption osseuse , Implants dentaires , Denture , Diagnostic , Esthétique , Mandibule , Maxillaire , Maladies parodontales , Parodontite , Phonétique , Prothèses et implants , Attelles , Transplantation de tissu , Extraction dentaire , Transplants
9.
Article de Coréen | WPRIM | ID: wpr-99573

RÉSUMÉ

PURPOSE: This study compared shear bond strengths of five self-adhesive cements with phosphate monomer to zirconium oxide ceramic with and without airborn particle abrasion. MATERIALS AND METHODS: One hundred zirconia samples were air-abraded (50 microm Al2O3). One hundred composite resin cylinders were fabricated. Composite cylinders were bonded to the zirconia samples with either Permacem 2.0 (P), Clearfil(TM) SA Luting (C), Multilink(R) Speed (M), RelyX(TM) U200 Automix (R), G-Cem LinkAce(TM) (G). All bonded specimens were stored in distilled water (37degrees C) for 24 h and half of them were additionally aged by thermocycling (5degrees C, 55degrees C, 5,000 times). The bonded specimens were loaded in shear force until fracture (1 mm/min) by using Universal Testing Machine (Model 4201, Instron Co, Canton, MA, USA). The failure sites were inspected under field-emission scanning electron microscopy. The data was analyzed with ANOVA, Tukey HSD post-hoc test and paired samples t-test (alpha=.05). RESULTS: Before and after thermocycling, Multilink(R) Speed (M) revealed higher shear-bond strength than the other cements. G-Cem LinkAce(TM) (G) showed significantly lower bond strengths after thermocycling than before treatment (P.05). CONCLUSION: Most self-adhesive cements with phosphate monomer showed high shear bond strength with zirconia ceramic and weren't influenced by thermocycling, so they seem to valuable to zirconia ceramic bonding.


Sujet(s)
Céramiques , Microscopie électronique à balayage , Céments résine , Eau , Zirconium
10.
Article de Anglais | WPRIM | ID: wpr-144357

RÉSUMÉ

PURPOSE: The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS: It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10 x 10 x 1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS: The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION: The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.


Sujet(s)
Animaux , Souris , Alliages , Corrosion , Alliage dentaire , Fibroblastes , Ions , Alliages métal céramique , Nickel , Plasma sanguin , Titane
11.
Article de Anglais | WPRIM | ID: wpr-144364

RÉSUMÉ

PURPOSE: The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS: It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10 x 10 x 1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS: The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION: The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.


Sujet(s)
Animaux , Souris , Alliages , Corrosion , Alliage dentaire , Fibroblastes , Ions , Alliages métal céramique , Nickel , Plasma sanguin , Titane
12.
Article de Anglais | WPRIM | ID: wpr-28671

RÉSUMÉ

PURPOSE: This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS: Sixty specimens were cut in 15 x 2.75 mm discs using zirconia. After air blasting of 50 microm alumina, samples were prepared by tribochemical silica coating with Rocatec(TM) plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+Calibra(R), (2) Monobond S+Multilink(R) N and (3) ESPN sil+RelyX(TM) Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS: In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION: In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.


Sujet(s)
Oxyde d'aluminium , Céramiques , Champignons , Polytétrafluoroéthylène , Céments résine , Silice
13.
Article de Anglais | WPRIM | ID: wpr-50565

RÉSUMÉ

PURPOSE: The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia. MATERIALS AND METHODS: Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (alpha< or =.05) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (alpha< or =.05). RESULTS: The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups. CONCLUSION: The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.


Sujet(s)
Alliages , Porcelaine dentaire , Prothèses et implants , Résistance à la traction
14.
Article de Coréen | WPRIM | ID: wpr-56595

RÉSUMÉ

PURPOSE: The purpose of this study was to evaluate the effect of surface treatment on the shear bond strength of zirconia ceramic to 3 resin cements. MATERIALS AND METHODS: A total of 143 disk-shaped Zirconia blocks (HASS Co., Gangneung, Korea) were randomly divided into three treatment groups: (1) only 50 microm Al2O3 sandblasting, (2) 50 microm Al2O3 sandblast and zircona liner, (3) 50 microm Al2O3 sandblasting and Rocatec (3M ESPE, Seefeld, Germany). Bistite II (Tokuyama Dental Co., Japan), Panavia F (Kuraray Medical, Japan), and Superbond C&B (Sun Medical, Japan) were used to cement onto the zirconia. After 24h of storage in distilled water, shear bond strength was evaluated. High value group was re-tested after thermocycling at 5,000 cycles(5-55degreesC). Shear bond strength data were analyzed with one-way ANOVA, two-way ANOVA test and Post Hoc Test (alpha=.05). Shear bond strength data before and after thermocycling were analyzed with Independent sample T test (alpha=.05). RESULTS: Super-bond C&B treated with Rocatec showed the most high shear bond strength. Super-bond C&B groups resulted in significantly higher than other cement groups (P<.05). Rocatec groups resulted in significantly higher than other surface treatment groups (P<.05). Shear bond strength has increased in Panavia F treated with Zirconia liner (P<.05). After thermocycling, shear bond strength was increased in Super-bond C&B treated with Rocatec but decreased in other groups (P<.05). CONCLUSION: Super-bond C&B cement resulted the highest shear bond strength and Rocatec system enhanced the shear bond strength. After thermocycling, shear bond strength has decreased in most resin cements except Super-bond C&B treated with Rocatec.


Sujet(s)
Composés du bore , Céramiques , Ciments dentaires , Méthacrylates , Méthacrylates de méthyle , Céments résine , Résines synthétiques , Eau , Zirconium
15.
Article de Coréen | WPRIM | ID: wpr-229222

RÉSUMÉ

PURPOSE: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and C. albicans adhesion of polyamide denture base. MATERIALS AND METHODS: Using contact profilometer, the surface of polyamide specimens (25x15x2 mm) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of C. albicans, C. albicans suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. RESULTS: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was 0.32 +/- 0.10 microm, and the lowest was 0.02 +/- 0.00 microm. The adhesion of C. albicans on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group (P.01).


Sujet(s)
Agar-agar , Candida , Candida albicans , Bases d'appareil de prothèse dentaire , Appareils de prothèse dentaire , Électrons , Nylons , Silicates , Tungstène , Composés du tungstène
16.
Article de Coréen | WPRIM | ID: wpr-94354

RÉSUMÉ

PURPOSE: The purpose of this study was to evaluate the level of electro-chemical corrosion and surface roughness change for the cases of Ti abutment connected to restoration made of base metal alloys. MATERIALS AND METHODS: It was hypothesized that Ni-Cr alloys in different compositions possess different corrosion resistances, and thus the specimens (13x13x1.5 mm) in this study were fabricated with 3 different types of metal alloys, commonly used for metal ceramic restorations. The electrochemical characteristics were evaluated with potentiostat (Parstat 2273A) and the level of surface roughness change was observed with surface roughness tester. Paired t-test was used to compare mean average surface roughness (Ra) changes of each specimen group. RESULTS: All specimens made of nickel-chromium based alloys, average surface roughness was increased significantly (P < .05). Among them, the Ni-Cr-Be alloy (0.016 +/- 0.007 microm) had the largest change of roughness followed by Ni-Cr (0.012 +/- 0.003 microm) and Ni-Cr-Ti (0.012 +/- 0.002 microm) alloy. There was no significant changes in surface roughness between each metal alloys after corrosion. CONCLUSION: In the case of galvanic couples of Ti in contact with all specimens made of nickel-chromium based alloys, average surface roughness was increased.


Sujet(s)
Alliages , Alliages de chrome , Corrosion , Caractéristiques familiales , Alliages métal céramique , Titane
17.
Article de Anglais | WPRIM | ID: wpr-68098

RÉSUMÉ

PURPOSE: The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS: The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10degrees of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (alpha = .05), and the statistical significance was set at P < .05. RESULTS: The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION: Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and 10degrees mesial angulated groups.


Sujet(s)
Lumière , Polyvinyles , Siloxanes
18.
Article de Coréen | WPRIM | ID: wpr-227843

RÉSUMÉ

OBJECTIVE: This study was aimed to identify the diagnostic role of HPV DNA chip test that may predict high grade lesions in gladular cell abnormalities on cervical cytology. METHODS: This study was performed in 88 patients, who were reported for atypical glandular cells on liquid-based cytologic test and was done subsequent cervical biopsies in Chonnam National University Hospital, between January 2003 and June 2007. HPV DNA chip test was performed on residual material of previous liquid-based cytologic test. And it was compared with pathologic results. RESULTS: Of the 88 patients with atypical glandular cells, the distribution was as follows: 60 patients were reported as atypical glandular cells, not otherwise specified (AGC, NOS), 28 patients were reported as atypical glandular cells, favor neoplastics (AGC, favor neoplastics). Of the 88 patients with an AGC result, pathologic results were as follows: 47 patients (53.4%) had a clinically significant high grade lesions. Of this high grade lesions, 5 cases of high grade squamous intraepithelial lesion, CIN 2 & CIN 3 (83.4%, 5/6), 2 cases of SCC (66.7%, 2/3), 4 cases of AIS (80.0%, 4/5), and 11 cases of endocervical adenocarcinoma (69%, 11/16) were positive on HPV DNA chip test. The sensitivity of human papilloma virus positivity to predict the presence of high grade lesion in cervix was 73.3%, specificity 85.3%, positive predictive value 78.5%, and negative predictive value 81.3%. There were 16 patients with endometrial cancer. Only 3 patients were HPV DNA chip positive. CONCLUSION: HPV DNA detection was strongly associated with high grade lesions in women with atypical glandular cells on cervical pap smear. These results suggest that although there is no high grade lesion in patients with HPV positive AGC-NOS at initial work-up, meticulous search like cone biopsy should be done to find high grade lesion. If the women with a diagnosis of AGC on pap smear are over 35 years of age and has abnormal utero-vaginal bleeding, this patients needed to be evaluated with endometrial biopsy.


Sujet(s)
Femelle , Humains , Adénocarcinome , Biopsie , Col de l'utérus , ADN , Tumeurs de l'endomètre , Hémorragie , Séquençage par oligonucléotides en batterie , Papillome , Sensibilité et spécificité , Virus
19.
Article de Coréen | WPRIM | ID: wpr-227845

RÉSUMÉ

OBJECTIVE: To investigate the lipid peroxide levels and protein carbonyls levels in the amniotic fluid of pregnant women with preterm premature rupture of membranes (PPROM). METHODS: The lipid peroxide levels in the amniotic fluid of normal pregnancy (n=20) and pregnant women with PPROM (n=20) were measured by thiobarbituric acid reaction. The protein carbonyl contents in the amniotic fluid of normal pregnancy (n=20) and pregnant women with PPROM (n=20) were determined by the 2,4-dinitrophenylhydrazine method. After amniotic fluid of them were mixed and incubated up to 5 hours with 0.2 mL of 1mM moxalactam, cefodizime, amoxacillin, erythromycin, the lipid peroxide levels and protein carbonyl contents in them were measured. RESULTS: 1. The lipid peroxide levels in the amniotic fluid of pregnant women with PPROM was significantly higher than that of normal pregnancy (9.74+/-0.48 vs. 7.20+/-0.38 nmol/mg protein, P<0.01). 2. The protein carbonyl levels in the amniotic fluid of pregnant women with PPROM was significantly higher than that of normal pregnancy (13.0+/-0.33 vs. 11.27+/-0.17 nmol/mg protein P<0.01). 3. The lipid peroxide levels and protein carbonyls formation by moxalactam in the amniotic fluid of pregnant women with PPROM was significantly higher than basal level (12.08+/-0.81 vs. 9.74+/-0.48 nmol/mg protein, 20.08+/-0.66 vs. 13.0+/-0.33 nmol/mg protein, P<0.01). 4. The lipid peroxide levels and protein carbonyls formation by cefodizime in the amniotic fluid of pregnant women with PPROM was significantly lower than basal level (5.04+/-0.33 vs. 9.74+/-0.48 nmol/mg protein, 9.76+/-0.35 vs. 13.0+/-0.33 nmol/mg protein, P<0.01). 5. There were no significant differences in the levels of lipid peroxide and protein carbonyls by amoxacillin and erythromycin in the amniotic fluid of pregnant women with PPROM between antibiotics-induced and basal levels. CONCLUSION: The lipid peroxidation and the protein carbonyls formation were increased in the amniotic fluid of pregnant women with PPROM. Antibiotics-induced lipid peroxide and protein carbonyl levels were changed in the amniotic fluid of pregnant women with PPROM. Further studies on our results may be beneficial in the selection of antibiotics for pregnant women with PPROM.


Sujet(s)
Femelle , Humains , Grossesse , Liquide amniotique , Antibactériens , Céfotaxime , Érythromycine , Peroxydation lipidique , Membranes , Latamoxef , Phénylhydrazines , Femmes enceintes , Carbonylation des protéines , Rupture , Thiobarbituriques
20.
Article de Anglais | WPRIM | ID: wpr-148374

RÉSUMÉ

PURPOSE: The aim of this study was to evaluate adhesion and gene expression of the MC3T3-E1 cells cultured on machined titanium surface (MS) and anodized titanium surface (AS) using MTT test, Scanning electron micrograph and cDNA microarray. MATERIALS AND METHODS: The MTT test assay was used for examining the proliferation of MC3T3-E1 cells, osteoblast like cells from Rat calvaria, on MS and AS for 24 hours and 48 hours. Cell cultures were incubated for 24 hours to evaluate the influence of the substrate geometry on both surfaces using a Scanning Electron Micrograph (SEM). The cDNA microarray Agilent Rat 22K chip was used to monitor expressions of genes. RESULTS: After 24 hours of adhesion, the cell density on AS was higher than MS (p0.05). AS had the irregular, rough and porous surface texture. After 48 hours incubation of the MC3T3-E1 cells, connective tissue growth factor (CTGF) was up-regulated on AS than MS (more than 2 fold) and the insulin-like growth factor 1 receptor was down-regulated (more than 2 fold) on AS than MS. CONCLUSION: Microarray assay at 48 hours after culturing the cells on both surfaces revealed that osteoinductive molecules appeared more prominent on AS, whereas the adhesion molecules on the biomaterial were higher on MS than AS, which will affect the phenotype of the plated cells depending on the surface morphology.


Sujet(s)
Animaux , Rats , Numération cellulaire , Techniques de culture cellulaire , Cellules du tissu conjonctif , ADN , ADN complémentaire , Électrons , Expression des gènes , Séquençage par oligonucléotides en batterie , Composés organothiophosphorés , Ostéoblastes , Phénotype , Crâne , Titane
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE