Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 67
Filtrer
1.
Article de Anglais | WPRIM | ID: wpr-1043501

RÉSUMÉ

Background@#We aimed to analyze the impact of concomitant Maze procedure on the clinical and rhythm outcomes, and echocardiographic parameters in tricuspid repair for patients with severe tricuspid regurgitation (TR) and persistent atrial fibrillation (AF). @*Methods@#Patients who had severe TR and persistent AF and underwent tricuspid valve (TV) repair were included in the study. Both primary TR and secondary TR were included in the current study. The study population was stratified according to Maze procedure. The primary outcome was major adverse cardiovascular and cerebrovascular event (MACCE) at 15 years postsurgery. Propensity-score matching analyses was performed to adjust baseline differences. @*Results@#Three hundred seventy-one patients who underwent tricuspid repair for severe TR and persistent AF from 1994 to 2021 were included, and 198 patients (53.4%) underwent concomitant Maze procedure. The maze group showed 10-year sinus rhythm (SR) restoration rate of 55%. In the matched cohort, the maze group showed a lower cumulative incidence of cardiac death (4.6% vs. 14.4%, P = 0.131), readmission for heart failure (8.1% vs. 22.2%, P = 0.073), and MACCE (21.1% vs. 42.1%, P = 0.029) at 15 years compared to the non-maze group. Left atrial (LA) diameter significantly decreased in the maze group at 5 years (53.3 vs. 59.6 mm, P < 0.001) after surgery compared to preoperative level, and there was a significant difference in the change of LA diameter over time between the two groups (P = 0.013). @*Conclusion@#The Maze procedure during TV repair in patients with severe TR and persistent AF showed acceptable SR rates and lower MACCE rates compared to those without the procedure, while also promoting LA reverse remodeling.

2.
Yonsei Medical Journal ; : 148-151, 2023.
Article de Anglais | WPRIM | ID: wpr-968878

RÉSUMÉ

Idiopathic hypereosinophilic syndrome (iHES) is a rare systemic disease that is characterized by persistent peripheral eosinophilia (absolute eosinophil count ≥1500/uL) for more than 6 months, with end-organ damage and absence of a primary cause for eosinophilia. Coronary artery aneurysm (CAA) is a rare but life-threatening complication. Here, we report a case of CAA with thrombosis in a patient with iHES in whom the disease activity was well-controlled (eosinophil count <500/uL) for several years. Despite modest control of the disease activity, giant CAA can be associated with iHES; and therefore, close surveillance and monitoring for the development of complications is warranted.

3.
Article de Anglais | WPRIM | ID: wpr-1041258

RÉSUMÉ

Background@#In the era of transcatheter aortic valve implantation, this study was conducted to investigate the current trend of aortic valve procedures in Korea and to evaluate the early and mid-term outcomes of isolated surgical aortic valve replacement (SAVR) using bioprosthetic valves in contemporary Korea. @*Methods@#Contemporary outcomes of isolated bioprosthetic SAVR in Korea were analyzed using the datasets on a multicenter basis. Patients who underwent isolated SAVR using bioprostheses from June 2015 to May 2019 were included, and those with concomitant cardiac procedures, SAVR with mechanical valve, or SAVR for infective endocarditis were excluded. A total of 456 patients from 4 large-volume centers were enrolled in this study.Median follow-up duration was 43.4 months. Early postoperative outcomes, mid-term clinical outcomes, and echocardiographic outcomes were evaluated. @*Results@#Mean age of the patients was 73.1 ± 7.3 years, and EuroSCORE II was 2.23 ± 2.09. The cardiopulmonary bypass time and aortic cross-clamp times were median 106 and 76 minutes, respectively. SAVR was performed with full median sternotomy (81.8%), right thoracotomy (14.7%), or partial sternotomy (3.5%). Operative mortality was 1.8%. The incidences of stroke and permanent pacemaker implantation were 1.1% and 1.1%, respectively. Paravalvular regurgitation ≥ mild was detected in 2.6% of the patients. Cumulative incidence of all-cause mortality at 5 years was 13.0%. Cumulative incidences of cardiovascular mortality and bioprosthetic valve dysfunction at 5 years were 7.6% and 6.8%, respectively. @*Conclusion@#The most recent data for isolated SAVR using bioprostheses in Korea resulted in excellent early and mid-term outcomes in a multicenter study.

4.
Article de Anglais | WPRIM | ID: wpr-831670

RÉSUMÉ

Background@#Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) might be considered a bridge therapy in patients who are expected to have short waiting times for heart transplantation. We investigated the clinical outcomes of patients who underwent VA-ECMO as a bridge to heart transplantation and whether the deployment of an early extubation ECMO strategy is beneficial. @*Methods@#Between November 2006 and December 2018, we studied 102 patients who received VA-ECMO as a bridge to heart transplantation. We classified these patients into an early extubation ECMO group (n = 24) and a deferred extubation ECMO group (n = 78) based on the length of the intubated period on VA-ECMO (≤ 48 hours or > 48 hours). The primary outcome was in-hospital mortality. @*Results@#The median duration of early extubation VA-ECMO was 10.0 (4.3–17.3) days.The most common cause for patients to be put on ECMO was dilated cardiomyopathy (65.7%) followed by ischemic cardiomyopathy (11.8%). In-hospital mortality rates for the deferred extubation and early extubation groups, respectively, were 24.4% and 8.3% (P = 0.147). During the study period, in the deferred extubation group, 60 (76.9%) underwent transplantation, while 22 (91.7%) underwent transplantation in the early extubation group.Delirium occurred in 83.3% and 33.3% of patients from the deferred extubation and early extubation groups (P < 0.001) and microbiologically confirmed infection was identified in 64.1% and 41.7% of patients from the two groups (P = 0.051), respectively. @*Conclusion@#VA-ECMO as a bridge therapy seems to be feasible for deployment in patients with a short waiting time for heart transplantation. Deployment of the early extubation ECMO strategy was associated with reductions in delirium and infection in this population.

5.
Article | WPRIM | ID: wpr-835293

RÉSUMÉ

A 59-year-old man presented for possible durable ventricular assist device (VAD) implantation. He had previously been diagnosed with congenitally corrected transposition of the great arteries, a ventricular septal defect, an atrial septal defect, pulmonary valve stenosis, and aortic valve regurgitation. In the previous 22 years, he had undergone palliative cardiac surgery 3 times. VAD implantation as a bridge to transplantation was planned. Owing to severe adhesions, mesocardia, a left ascending aorta, and moderate aortic regurgitation, we performed VAD implantation and aortic valve closure via a dual left thoracotomy and partial sternotomy.

6.
Korean Circulation Journal ; : 657-677, 2019.
Article de Anglais | WPRIM | ID: wpr-917246

RÉSUMÉ

Extracorporeal membrane oxygenation (ECMO) is a technique that uses a pump to drain blood from a body, circulate blood through a membrane lung, and return the oxygenated blood back into the body. Venoarterial (VA) ECMO is a simplified version of the heart-lung machine that assists native pulmonary and/or cardiac function. VA ECMO is composed of a drainage cannula in the venous system and a return cannula in the arterial system. Because VA ECMO can increase tissue perfusion by increasing the arterial blood flow, it is used to treat medically refractory cardiogenic shock or cardiac arrest. VA ECMO has a distinct physiology that is referred to as differential flows. It can cause several complications such as left ventricular distension with pulmonary edema, distal limb ischemia, bleeding, and thromboembolism. Physicians who are using this technology should be knowledgeable on the prevention and management of these complications. We review the basic physiology of VA ECMO, the mechanism of complications, and the simple management of VA ECMO.

7.
Article de Anglais | WPRIM | ID: wpr-939174

RÉSUMÉ

Right heart failure is a relatively common complication after left ventricular assist device (LVAD) implantation. Severe right heart failure can be managed by temporary right ventricular assist device (RVAD) implantation. However, trans-sternal RVAD insertion requires a subsequent third sternotomy for cannula removal. Herein, we present a case of RVAD insertion via a left anterior mini-thoracotomy after LVAD implantation in a patient with alcohol-induced cardiomyopathy.

8.
Article de Anglais | WPRIM | ID: wpr-939179

RÉSUMÉ

BACKGROUND@#Extracorporeal life support (ECLS) is used as a bridge to revascularization in high-risk patients with ischemic heart disease. We reviewed our experiences of coronary artery bypass grafting (CABG) after ECLS in patients with cardiac arrest or refractory cardiogenic shock.@*METHODS@#We retrospectively reviewed 4,616 patients who underwent CABG at our institution between May 2006 and February 2017. We identified patients who underwent CABG following ECLS for cardiogenic shock or cardiac arrest. Twenty-three patients (0.5% of all CABG cases) were enrolled in the analysis. Their median age was 65 years (Q1–Q3, 58–77 years). Nine patients (39.1%) were diagnosed with ST-elevation myocardial infarction. Mechanical complications after acute myocardial infarction, including acute mitral regurgitation, left ventricular rupture, and ventricular septal defect, occurred in 9 patients (39.1%).@*RESULTS@#The median time from cardiopulmonary resuscitation to ECLS initiation was 25 minutes (Q1–Q3, 18.5–28.5 minutes). Conventional CABG was performed in 10 patients (43.5%) who underwent concomitant intracardiac procedures. Postoperative ECLS was required in 16 patients (69.5%). The rate of successful ECLS weaning was 91.3% (n=21). There were 6 early mortalities (26.1%).@*CONCLUSION@#CABG after ECLS was very rare in real-world circumstances. Although the early mortality rate was high, the risk of mortality may be acceptable under such devastating circumstances.

9.
Article de Anglais | WPRIM | ID: wpr-761838

RÉSUMÉ

Right heart failure is a relatively common complication after left ventricular assist device (LVAD) implantation. Severe right heart failure can be managed by temporary right ventricular assist device (RVAD) implantation. However, trans-sternal RVAD insertion requires a subsequent third sternotomy for cannula removal. Herein, we present a case of RVAD insertion via a left anterior mini-thoracotomy after LVAD implantation in a patient with alcohol-induced cardiomyopathy.


Sujet(s)
Humains , Cardiomyopathies , Cathéters , Défaillance cardiaque , Dispositifs d'assistance circulatoire , Sternotomie , Thoracotomie
10.
Article de Anglais | WPRIM | ID: wpr-761843

RÉSUMÉ

BACKGROUND: Extracorporeal life support (ECLS) is used as a bridge to revascularization in high-risk patients with ischemic heart disease. We reviewed our experiences of coronary artery bypass grafting (CABG) after ECLS in patients with cardiac arrest or refractory cardiogenic shock. METHODS: We retrospectively reviewed 4,616 patients who underwent CABG at our institution between May 2006 and February 2017. We identified patients who underwent CABG following ECLS for cardiogenic shock or cardiac arrest. Twenty-three patients (0.5% of all CABG cases) were enrolled in the analysis. Their median age was 65 years (Q1–Q3, 58–77 years). Nine patients (39.1%) were diagnosed with ST-elevation myocardial infarction. Mechanical complications after acute myocardial infarction, including acute mitral regurgitation, left ventricular rupture, and ventricular septal defect, occurred in 9 patients (39.1%). RESULTS: The median time from cardiopulmonary resuscitation to ECLS initiation was 25 minutes (Q1–Q3, 18.5–28.5 minutes). Conventional CABG was performed in 10 patients (43.5%) who underwent concomitant intracardiac procedures. Postoperative ECLS was required in 16 patients (69.5%). The rate of successful ECLS weaning was 91.3% (n=21). There were 6 early mortalities (26.1%). CONCLUSION: CABG after ECLS was very rare in real-world circumstances. Although the early mortality rate was high, the risk of mortality may be acceptable under such devastating circumstances.


Sujet(s)
Humains , Réanimation cardiopulmonaire , Pontage aortocoronarien , Vaisseaux coronaires , Oxygénation extracorporelle sur oxygénateur à membrane , Arrêt cardiaque , Communications interventriculaires , Insuffisance mitrale , Mortalité , Infarctus du myocarde , Ischémie myocardique , Études rétrospectives , Rupture , Choc cardiogénique , Sevrage
11.
Korean Circulation Journal ; : 657-677, 2019.
Article de Anglais | WPRIM | ID: wpr-759465

RÉSUMÉ

Extracorporeal membrane oxygenation (ECMO) is a technique that uses a pump to drain blood from a body, circulate blood through a membrane lung, and return the oxygenated blood back into the body. Venoarterial (VA) ECMO is a simplified version of the heart-lung machine that assists native pulmonary and/or cardiac function. VA ECMO is composed of a drainage cannula in the venous system and a return cannula in the arterial system. Because VA ECMO can increase tissue perfusion by increasing the arterial blood flow, it is used to treat medically refractory cardiogenic shock or cardiac arrest. VA ECMO has a distinct physiology that is referred to as differential flows. It can cause several complications such as left ventricular distension with pulmonary edema, distal limb ischemia, bleeding, and thromboembolism. Physicians who are using this technology should be knowledgeable on the prevention and management of these complications. We review the basic physiology of VA ECMO, the mechanism of complications, and the simple management of VA ECMO.


Sujet(s)
Cathéters , Drainage , Oxygénation extracorporelle sur oxygénateur à membrane , Membres , Arrêt cardiaque , Coeur-poumon artificiel , Hémorragie , Ischémie , Poumon , Membranes , Oxygène , Perfusion , Physiologie , Complications postopératoires , Oedème pulmonaire , Choc , Choc cardiogénique , Thromboembolie
12.
Article de Anglais | WPRIM | ID: wpr-716544

RÉSUMÉ

A 68-year-old man presented with a posterior tracheal wall injury caused by percutaneous dilatational tracheostomy. The wound was immediately covered with an absorbable polyglycolic acid sheet. Ten days after the injury, the perforation was closed with knotless sutures using a Castroviejo needle-holder through the tracheostomy. The successful repair in this case indicates the feasibility of the knotless suture technique for perforations. The technique is described in detail in this report. The patient was weaned from the mechanical ventilator on postoperative day 25. In cases of posterior tracheal posterior wall perforation, every effort should be made to repair the perforation through an existing opening.


Sujet(s)
Sujet âgé , Humains , Bronchoscopie , Acide polyglycolique , Techniques de suture , Matériaux de suture , Trachéostomie , Respirateurs artificiels , Plaies et blessures
13.
Article de Anglais | WPRIM | ID: wpr-713881

RÉSUMÉ

BACKGROUND: The question of which type of prosthetic aortic valve leads to the best outcomes in patients in their 60s remains controversial. We examined the hemodynamic and clinical outcomes of aortic valve replacement in sexagenarians according to the type of prosthesis. METHODS: We retrospectively reviewed 270 patients in their 60s who underwent first-time aortic valve replacement from 1995 to 2011. Early and late mortality, major adverse valve-related events, anticoagulation-related events, and hemodynamic outcomes were assessed. The mean follow-up duration was 58.7±44.0 months. RESULTS: Of the 270 patients, 93 had a mechanical prosthesis (mechanical group), and 177 had a bioprosthesis (tissue group). The tissue group had a higher mean age and prevalence of preoperative stroke than the mechanical group. The groups had no differences in the aortic valve mean pressure gradient (AVMPG) or the left ventricular mass index (LVMI) at 5 years after surgery. In a sub-analysis limited to prostheses in the supra-annular position, the AVMPG was higher in the tissue group, but the LVMI was still not significantly different. There was no early mortality. The 10-year survival rate was 83% in the mechanical group and 90% in the tissue group. The type of aortic prosthesis did not influence overall mortality, cardiac mortality, or major adverse valve-related events. Anticoagulation-related events were more common in the mechanical group than in the tissue group (p=0.034; hazard ratio, 4.100; 95% confidence interval, 1.111–15.132). CONCLUSION: The type of aortic prosthesis was not associated with hemodynamic or clinical outcomes, except for anticoagulation-related events.


Sujet(s)
Humains , Valve aortique , Bioprothèse , Études de suivi , Hémodynamique , Mortalité , Prévalence , Prothèses et implants , Études rétrospectives , Accident vasculaire cérébral , Taux de survie
17.
Article de Anglais | WPRIM | ID: wpr-10926

RÉSUMÉ

BACKGROUND: Extracorporeal life support (ECLS) is widely used in refractory heart or lung failure, and the demand for inter-facility transportation on ECLS is expanding. However, little is known about post-transportation outcomes, the clinical safety of such transportation, or the characteristics of the transported patients. METHODS: This was a retrospective review of a 3-year, single-institution experience with inter-facility ECLS transport, as well as a comparative analysis of clinical outcomes with those of in-house patients. We also analyzed the risk factors for hospital mortality in the entire ECLS population using univariate and multivariate analyses to investigate the effects of transport. RESULTS: All 44 patients were safely transported without adverse events. The average travel distance was 178.7 km, with an average travel time of 74.0 minutes. Early survival of the transported group seemed to be better than that of the in-house group, but the difference was not statistically significant (70.5% vs. 56.6%, p=0.096). The incidence of complications was similar between the 2 groups, except for critical limb ischemia, which was significantly more common in the transported group than in the in-house group (25.0% vs. 8.1%, p=0.017). After adjusting for confounders, being part of the transported group was not a predictor of early death (adjusted odds ratio, 0.689; p=0.397). CONCLUSION: Transportation of patients on ECLS is relatively safe, and the clinical outcomes of transported patients are comparable to those of in-house ECLS patients. Although matched studies are required, our study demonstrates that transporting patients on ECLS did not increase their risk of hospital mortality after adjustment for other factors.


Sujet(s)
Humains , Oxygénation extracorporelle sur oxygénateur à membrane , Membres , Coeur , Mortalité hospitalière , Incidence , Ischémie , Poumon , Analyse multifactorielle , Odds ratio , Études rétrospectives , Facteurs de risque , Transports , Transport sanitaire
18.
Article de Anglais | WPRIM | ID: wpr-10932

RÉSUMÉ

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) has become an important treatment modality in pediatric patients with cardiopulmonary failure, but few studies have been conducted in Korea. METHODS: We conducted a retrospective review of pediatric patients younger than 18 years who were placed on ECMO between January 2004 and December 2014 at Samsung Medical Center. RESULTS: We identified 116 children on ECMO support. The overall rate of successful weaning was 51.7%, and the survival to discharge rate was 37.1%. There were 39, 61, and 16 patients on ECMO for respiratory, cardiac, and extracorporeal cardiopulmonary resuscitation, respectively. The weaning rate in each group was 48.7%, 55.7%, and 43.8%, respectively. The survival rate was 43.6%, 36.1%, and 25.0%, respectively. Sixteen patients on ECMO had functional single ventricle physiology; in this group, the weaning rate was 43.8% and the survival rate was 31.3%. Ten patients were on ECMO as a bridge to transplantation (8 for heart and 2 for lung). In patients with heart transplantation, the rate of survival to transplantation was 50.0%, and the overall rate of survival to discharge was 37.5%. CONCLUSION: An increasing trend in pediatric ECMO utilization was observed. The outcomes were favorable considering the early experiences that were included in this study and the limited supply of specialized equipment for pediatric patients.


Sujet(s)
Enfant , Humains , Réanimation cardiopulmonaire , Oxygénation extracorporelle sur oxygénateur à membrane , Coeur , Cardiopathies congénitales , Transplantation cardiaque , Dispositifs d'assistance circulatoire , Corée , Physiologie , Études rétrospectives , Taux de survie , Transplantation , Sevrage
19.
Korean Journal of Medicine ; : 292-295, 2016.
Article de Anglais | WPRIM | ID: wpr-20330

RÉSUMÉ

Here we describe a case of rapidly expanding ascending aortic aneurysm in a patient with relapsing polychondritis. To prevent aneurysm rupture, the patient underwent emergent surgical repair. Silent inflammation can progress in the aorta wall, even in asymptomatic patients with mild disease activity under immunosuppressive treatment, leading to the rapid growth of aortic aneurysms. Close monitoring with routine imaging is needed once a patient with relapsing polychondritis is diagnosed with an aortic aneurysm.


Sujet(s)
Humains , Anévrysme , Aorte , Anévrysme de l'aorte , Aortite , Inflammation , Polychondrite chronique atrophiante , Rupture
20.
Article de Anglais | WPRIM | ID: wpr-41316

RÉSUMÉ

Aortic pseudoaneurysm after cardiac surgery is a rare entity, but it is potentially fatal due to its clinical course along with higher morbidity and mortality rates. Instead of open surgical repair, percutaneous procedures have been introduced as other options for managing an aortic pseudoaneurysm. In this case report, we describe transesophageal echocardiography guidance for successful percutaneous closure of an aortic pseudoaneurysm located in the left ventricular outflow tract by using a type II Amplatzer vascular plug in a patient in whom open surgical repair was not recommended.


Sujet(s)
Humains , Faux anévrisme , Échocardiographie , Échocardiographie transoesophagienne , Mortalité , Métastase tumorale , Syndrome de compression médullaire , Rachis , Chirurgie thoracique , Vertébroplastie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE