RÉSUMÉ
Between August 2008 and June 2012, 17 TEVAR procedures for thoracic aortic aneurysms (TAA) requiring Z2 coverage were performed at our institution. Patient age ranged from 46 to 82 years old (mean 69.4), 16 were male. Criteria for LSA revascularization at our institution are defined as either : 1) dominant left vertebral artery (VA), 2) absent or diminutive or occluded right VA, 3) no communication of bilateral VA, 4) bilateral carotid artery disease, 5) patent LIMA-coronary bypass, 6) if a long length of the thoracic aorta is covered. Devices utilized were Gore TAG (<i>n</i>=12) and TX2 (<i>n</i>=5). Deployment of the stent-graft (SG) was successful in 17 cases (100%) and complete thrombosis of the aneurysm or complete entry closure was achieved in 16 cases (94.1%). Axillo-axillar cross over bypass (Ax-Ax B) was performed in 5 cases (29.4%). There was no instance of cerebrospinal ischemia or hospital death and the mean follow-up was 22.9 month (range 5 to 46). One case was converted to open surgery due to secondary type 1 endoleak. There was no instance of Ax-Ax B graft occlusion or aneurysmal rupture. The initial and mid-term results of TEVAR requiring Z2 coverage were satisfactory, and we believe that our criteria for LSA revascularization played an important role in providing the satisfactory results.
RÉSUMÉ
We reporte the initial results of open stent-grafting (OSG) applied with a Matsui-Kitamura (MK) stent in the treatment of thoracic aortic aneurysm (TAA). From August 2005 to March 2011, OSG for TAA was applied in 35 cases (male/female, 29/6, 58∼86 years old, mean age 71). During deep hypothermic circulatory arrest with antegrade selective cerebral perfusion, the stent graft was delivered through the transected proximal aortic arch, followed by arch replacement with a 4-branched prosthesis. Concomitant procedures included 1 coronary artery bypass graft, 1 mitral valve replacement and 2 pacemaker implantations. Operative mortality within 30 days was 5.7% (respiratory failure in 1 and ischemic enteritis in 1). There was 1 in-hospital death due to brain stem infarction. Perioperative morbidity included 2 (5.7%) stroke, 5 (14.3%) spinal cord injuries (paraplegia in 1, paraparesis in 1 and transient paraparesis in 3) , and 1 (2.9%) temporary hemodialysis. Ten patients (28.6%) were intubated for more than 72 h. There was no complication with the graft-related incident. These initial results suggested the OSG method applied with a MK stent is a useful surgical procedure for the treatment of TAA.
RÉSUMÉ
We report the initial results of thoracic endovascular repair using the Gore TAG device (TAG) used in treatment of thoracic aortic aneurysms (TAA), and evaluate initial outcome based on the Japan SCORE (JS) system. From August 2008 to July 2009, thoracic aortic endovascular repair (TEVAR) for TAA was applied in 27 cases (men/women, 22/5, 53-88 years old, mean age 70.5). Locations included the distal arch in 7 cases, proximal descending TAA (dTAA) in 12 cases and middle or distal dTAA in 8 cases. Deployment of a stent-graft (SG) was successful in 27 cases (100%) and complete thrombosis of the aneurysm or complete entry closure was achieved in 26 cases (96.3%). There was 1 type 2 endoleak (3.7%), 2 iliac arterial injuries (7.4%) and 2 cases of temporary hemodialysis (7.4%). There was no occurrence of paraplegia or hospital death. The 30-day mortality rate and major complication rate examined by the Japan SCORE (JS) system did not show any statistical differences between the TEVAR group and the open repair (OR) group, however the data were higher in the TEVAR group, although not statisfically in the OR group. The OR group had a high complication incidence in comparison with the TEVAR group. Based on evaluation by the JS system, the initial results suggest that TAG for the treatment of TAA is superior to conventional open surgery.