Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
International Journal of Surgery ; (12): 823-828, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1018071

Résumé

Objective:To explore the application value of 3D-slicer software in measuring renal volume parameters of renal transplant donors in evaluating renal function.Methods:The data of 31 renal donors admitted to Beijing Friendship Hospital, Capital Medical University from October 2019 to September 2022 were retrospectively analyzed. Glomerular filtration rate (GFR) were measured by SPECT radioactive dynamic imaging, and renal cortex volume (RCV), renal parenchymal volume (RPV) were measured after 3D reconstruction of urinary enhanced CT based on 3D slicer software. The estimated GFR(eGFR) predicted by creatinine-based GFR estimation equations (C-G equation, modified and simplified MDRD equation) and volume-based GFR estimation equations (Herts equation, Choi equation). Different eGFR were calculated, and the correlation between kidney volume parameters, eGFR equations and measured GFR was analyzed. The deviation, accuracy and consistency between different equations eGFR and measured GFR were analyzed and compared. The measurement data of normal distribution were expressed as mean±standard deviation ( ± s), and t-test was used for inter-group comparison. Measurement data with non-normal distribution were represented by M( Q1, Q3), and non-parametric test was used for comparison between groups. Results:The correlation between different eGFR and measured GFR is poor, and the deviation is small, and with good accuracy and consistency. Except for the weak correlation between the Choi equation eGFR and measured GFR ( r=0.382, P=0.034), there was no significant correlation between eGFR by other equations and measured GFR ( P>0.05). Among them, the deviation between the Herts equation-eGFR and measured GFR was the smallest (0.30 mL·min -1·1.73 m -2), with a 10% coincidence rate (61.29%) and a 30% coincidence rate (96.77%), and the best consistency with measured GFR, with a consistency limit of -28.75 to 29.34 mL·min -1·1.73 m -2. Conclusion:Compared with the laboratory index formula method, the Herts equation has better prediction efficiency in estimating GFR, The measurement of renal volume parameters by 3D slicer software has a certain clinical value in evaluating the renal function of renal donors, which is worthy of further application.

2.
International Journal of Surgery ; (12): 676-680,C2, 2022.
Article Dans Chinois | WPRIM | ID: wpr-954274

Résumé

Objective:To investigate the application value of three-dimensional image reconstruction technology based on 3D-slicer software in urology.Methods:The data of 36 patients with urinary tract diseases admitted to Beijing Friendship Hospital, Capital Medical University from May 2019 to December 2021 were retrospectively analyzed, including 20 males and 16 females; the median age was 53.50(41.75, 66.25) years. There were 10 relative kidney transplant donors, 12 cases with renal tumors, 6 cases with hydronephrosis and 8 patients with urinary calculi. The CT urography data of 36 cases were reconstructed into three-dimensional image models based on 3D-slicer software, and the morphology of the target tissue was measured.Results:In the urinary system model of 10 relative kidney transplant donors constructed in this study, the type of donor renal artery was single artery in 7 cases and accessory renal artery in 3 cases; In the three-dimensional model of 12 tumor kidneys, 4 tumors were located at the upper part of the kidney (2 near ventral and 2 near dorsal), 5 tumors were located at the middle part of the kidney (2 near ventral and 3 near dorsal), and 3 tumors were located at the lower part of the kidney near ventral. The average maximum diameter of the tumors was (27.3 ± 9.63) mm, and the tumor volume was (15.89 ± 5.93) cm 2. The study also successfully constructed a three-dimensional image model of the urinary system in 6 patients with hydronephrosis and 8 patients with urinary calculi (without hydronephrosis). Three-dimensional model image reconstructed by 3D-slicer software clearly showed the spatial structure of renal parenchyma, blood vessels, renal pelvis, calyces and ureter. The diameter, position and direction of ureters and blood vessels can be observed clearly based on the three-dimensional reconstruction model, and clinicians could also evaluate the location, shape, size and adjacent relationship with surrounding tissues of renal cysts, tumors, stones or other masses. Conclusion:3D-slicer software platform can assist clinicians to reconstruct the three-dimensional model of urinary system, which is worthy of further clinical application.

3.
Article Dans Chinois | WPRIM | ID: wpr-406569

Résumé

Two recombinant plasmids pVAX/Sj23 and pVAX/mIL-18 containing Schistosoma japonicum 23 000 membrane protein (Sj23) and murine IL-18 were evaluated for their ability to induce immune responses and to protect against S. japonicum challenge in mice. All animals vaccinated with pVAX/Sj23 alone or plus pVAX/mIL-18 developed specific anti-SWAP (soluble worm antigen preparation) ELISA antibody and splenocyte proliferation response,and co-injection of pVAX/mIL-18 significantly increased the production of IFN-γ and IL-2 compared with pVAX/Sj23 alone, indicating that IL-18 enhances the Th1-dominant immune response. The challenge experiment showed that worm reduction rates in pVAX/Sj23 group compared with control group (pVAX1) was 26.5% and in the pVAX/Sj23 plus pVAX/mIL-18 group was 41.9% ,and the hepatic egg reduction rates were 42.7 and 49.6%,respectively. These results indicated that co-injection of an IL-18 plasmid with Sj23 DNA vaccine efficiently improves the protective effect against S. japonicum infection.

SÉLECTION CITATIONS
Détails de la recherche