RÉSUMÉ
Objective Pulmonary function testing is a commonly used indicator for clinical evaluation of the degree of pulmonary fibrosis in patients. This paper aims to investigate the dynamic changes of lung function in mice with pulmonary fibrosis and to establish a range of reference values for lung function parameters in normal Kunming mice. Methods Twenty-eight SPF Kunming mice were randomly divided into normal control group (n=14) and model group (n=14). After anesthesia with 10% chloral hydrate, the normal control group only underwent tracheal puncture. The model group received intratracheal puncture and injection of bleomycin (BLM) (5 mg/kg body weight), and the lung function indicators of all mice were detected in the same order on the 1st, 2nd, 3rd and 4th weekends after modeling: Ti, Te, PIF, PEF, TV, EV, RT, MV, f, Penh and EF50. Results After intratracheal BLM injection, mice in the model group showed decreased hair softness and smoothness, hair loss and decreased activity after the 2nd week. Compared with the control group, Ti, Te and RT values in the model group significantly increased at week 4 (P<0.05), while the values of PEF, RT, MV, f and EF50 decreased significantly at the same week (P<0.05). Compared with the model group at week 1, the differences in Ti, Te, RT and f values at week 2, 3 and 4 were statistically significant (P<0.05); the differences in MV and EF50 values at week 3 and 4 were statistically significant (P<0.05); while the PIF values only showed differences at week 4 (P<0.001). Compared with the Penh values in the control group at week 2, 3 and 4 (0.553±0.189, 0.662±0.164, 0.712±0.189), the differences of the model group (0.820±0.205, 0.936±0.188, 1.053±0.236) showed statistical significance (P<0.001). Compared with the model group at week 1, the differences of Penh values in the model group only showed statistical significance at week 3 and 4 (P<0.05). Through four-week lung function test, various parameters were obtained, among which the normal range of the main index Penh value was 0.27-0.88. Conclusion The lung function detected by the non-invasive whole body plethysmography system was stable and reliable with good effects; the lung function in mice with the BLM-induced pulmonary fibrosis continued to decrease within four weeks. Penh, which reflects airway resistance, can be used for overall screening of the lung function among the test mice after two weeks of modeling.
RÉSUMÉ
0bjective@#To establish a three-dimensional finite element model of mandible and study the transverse displacement of proximal segment after Bilateral Sagittal Split Ramus Osteotomy (BSSRO) with different retrogression amounts during mastication.@*Methods@#DICOM data of a skull model were processed with MIMICS and ANSYS software, reconstructing the 3D model including the teeth and temporomandibular joint in order to simulate BSSRO and evaluate the transverse displacement of proximal segment with different retrogression amounts during mastication.@*Results@#The mean of proximal segment width change were 2.955 mm and 3.490 mm, when retrogression amounts of distal segmentwere 3 mm and 8 mm, respectively.No significant difference between the two groups were found (P=0.131). Meanwhile the displacement color scale of the 3D finite element models showed that the apparent transverse displacement distribution of the proximal segment was measured around the gonial area, decreased from the exterior to the interior.@*Conclusions@#The mandibular angle width was significantly expanded right after BSSRO. The masticatory muscle system and single cortical fixation system played an important role in expanding the width of proximal segment. However there was no correlation between the widening effect and retrogression amounts of distal segment of mandible.
RÉSUMÉ
Objective@#To evaluate the surgical prediction accuracy of Proplan CMF software for zygomatic reduction surgery using L-shaped osteotomy.@*Methods@#Pre-and-postoperative 1-year CBCT data of 26 patients with zygomatic arch hypertrophy were imported in Proplan CMF software during 2014 Jan. to 2016 Jun., the 3D models were reconstructed for simulation of L-shaped osteotomy, characteristic landmarks were selected and 3D point measurement system was established. The measurement result were analyzed by one-way ANOVA. Meanwhile, the overlap color grading charts of preoperative and simulated images were also observed.@*Results@#The facial width, bilateral zygomatic process angle and facial width index were [(128.56±2.72) mm, (106.87±2.53)°, (108.56±3.02)°and 1.41±0.03] in postoperative result, [(129.49±2.26) mm, (108.68±2.40)°, (108.85±3.02)°and 1.42±0.03]in simulated result and [(135.45±2.45) mm, (102.50±2.60)°, (103.41±2.56)°and 1.48±0.05] in preoperative result, with significant difference between preoperative and postoperative result, or between preoperative and simulated result (P<0.05), while no significance between postoperative and simulated result (P>0.05). The soft tissue zygomatic process distance was(153.25±2.58) mm in preoperative result, (150.23±2.76)mm in postoperative result , (149.36±3.27)mm in simulated result, with no significance between any of two groups result (P>0.05). The zygomatic process distance and bilateral zygomatic process tragal distance were (126.35±2.56) mm, (68.75±2.15) mm and(68.86±3.21) mm in postoperative result, showing significant differences compared with preoperative result [(120.16±3.18) mm, (74.58±3.19) mm and(76.14±3.15) mm] and simulated result [(118.86±3.45) mm, (73.85±3.57) mm and(76.87±2.58) mm] respectively(P<0.05), while zygomatic arch distance was not statistically different among the three groups(P>0.05). It indicated that predictive accuracy of facial width, facial width index, zygomatic process angle, soft tissue zygomatic arch distance was high but the soft tissue zygomatic process distance and zygomatic process tragal distance was relatively low. Meanwhile, the color overlay image showed that predictive accuracy was not good in the zygomatic region while the zygomatic arch area was high.@*Conclusions@#The predictive accuracy of Proplan CMF software for zygomatic arch hypertrophy is relatively high except for the zygomatic region. Further improvement of the CMF software is needed.