1.
Article de Chinois | WPRIM | ID: wpr-1026221

RÉSUMÉ

Objective To assess inter-observer variations(IOV)in the delineation of target volumes and organs-at-risk(OAR)for intensity-modulated radiotherapy(IMRT)of nasopharyngeal carcinoma(NPC)among physicians from different levels of cancer centers,thereby providing a reference for quality control in multi-center clinical trials.Methods Twelve patients with NPC of different TMN stages were randomly selected.Three physicians from the same municipal cancer center manually delineated the target volume(GTVnx)and OAR for each patient.The manually modified and confirmed target volume(GTVnx)and OAR delineation structures by radiotherapy experts from the regional cancer center were used as the standard delineation.The absolute volume difference ratio(△V_diff),maximum/minimum volume ratio(MMR),coefficient of variation(CV),and Dice similarity coefficient(DSC)were used to compare the differences in organ delineation among physicians from different levels of cancer centers and among the 3 physicians from the same municipal cancer center.Furthermore,the IOV of GTVnx and OAR among physicians from different levels cancer centers were compared across different TMN stages.Results Significant differences in the delineation of GTVnx were observed among physicians from different levels of cancer centers.Among the 3 physicians,the maximum values of △V_diff,MMR,and CV were 97.23%±83.45%,2.19±0.75,and 0.31±0.14,respectively,with an average DSC of less than 0.7.Additionally,there were considerable differences in the delineation of small-volume OAR such as the left and right optic nerves,chiasm,and pituitary,with average MMR>2.8,CV>0.37,and DSC<0.51.However,relatively smaller differences were observed in the delineation of large-volume OAR such as the brainstem,spinal cord,left and right eyeballs,and left and right mandible,with average△V_diff<42%,MMR<1.55,and DSC>0.7.Compared with the differences among physicians from different levels cancer centers,the differences among the 3 physicians from the municipal cancer center were slightly reduced.Furthermore,there were also differences in the delineation of target volumes for NPC among physicians from different levels cancer centers,depending on the staging of the disease.Compared with the delineation of target volumes for earlier stage patients(stages I or II),the differences among physicians in the delineation of target volumes for advanced stage patients(stages III or IV)were smaller,with average △V_diff and DSC of 98.31%±67.36%vs 69.38%±72.61%(P<0.05)and 0.55±0.08 vs 0.72±0.12(P<0.05),respectively.Conclusion There are differences in the delineation of GTVnx and OAR in radiation therapy for NPC among physicians from different levels of cancer centers,especially in the delineation of target volume(GTVnx)and small-volume OAR for early-stage patients.To ensure the accuracy of multicenter clinical trials,it is recommended to provide unified training to physicians from different levels of cancer centers and review their delineation results to reduce the effect of differences on treatment outcomes.

2.
Article de Chinois | WPRIM | ID: wpr-427138

RÉSUMÉ

ObjectiveThis study was to explore the feasibility of using the orthogonal plane dose formed by the coronal and sagittal plane to verify the volumetric modulated arc therapy (VMAT) plan.MethodsThe VMAT plans of 12 patients were included in this study.The orthogonal plane dose formed by the coronal and sagittal plane were measured based on the combination of 2D ionization chamber array and multicube phantom,and the point dose were measured based on a multiple hole cylindrical phantom attached with two 0.125 cm3 ionization chamber probes.ResultsIn the measurement of the point dose,the average error was 1.5% in high dose area ( more than 80% of maximum),and 1.7% in low dose area ( less than 80% of maximum),respectively.The discrepancy of point dose measurement was 1.3% between the 2D ionization chamber array and the VMAT planning system.In the measurement of the orthogonal plane dose,the pass rate of γ were 93.7% for 2%/2 mm and 97.2% for 3%/3 mm.ConclusionIt is reliable for using the orthogonal plane dose formed by the coronal and sagittal plane to verify the VMAT plan.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE