Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Article Dans Chinois | WPRIM | ID: wpr-1021407

Résumé

BACKGROUND:High tibial osteotomy results in massive blood loss during the perioperative period.Tranexamic acid can effectively reduce perioperative blood loss.However,the method of tranexamic acid application has not been unified. OBJECTIVE:To investigate the effect and safety of different methods of tranexamic acid on perioperative blood loss in the high tibial osteotomy. METHODS:A total of 160 patients who underwent primary unilateral high tibial osteotomy in the Binzhou Medical University Hospital from January 2019 to December 2021,including 69 males and 91 females,were randomly divided into four groups(n=40 per group).Among them,40 patients were given an intravenous infusion of saline containing 2 g tranexamic acid 10 minutes before tourniquet release(venous group);40 patients were given an intravenous infusion of 1 g tranexamic acid and 1 g tranexamic acid was injected through a drainage tube after the closure of the incision(combined group);40 patients were given 2 g tranexamic acid infusion into drainage tube after the closure of the incision(perfusion group);an additional 40 patients were given an intravenous infusion of the same amount of normal saline(blank group).The general information was compared among the four groups of patients.The hemoglobin,hematocrit,intraoperative blood loss,drainage volume,blood transfusion rate,incision complication,and the incidence of deep vein thrombosis were recorded on days 1,3 and 5 after operation in the four groups.The total blood loss and hidden blood loss were calculated. RESULTS AND CONCLUSION:(1)There was no statistically significant difference in general information among the four groups.(2)No significant difference was found in intraoperative blood loss among the four groups.(3)The maximum decreased values of hemoglobin and hematocrit on days 1,3 and 5 after operation,drainage volume,total blood loss and hidden blood loss were all ranked as the combined group<venous group<perfusion group<blank group.(4)The postoperative blood transfusion rate of the blank group was significantly higher than that of the other three groups,and there was no significant difference in the postoperative blood transfusion rate among the combined group,the venous group and the perfusion group.(5)There was no significant difference in the incidence of venous thrombosis and incision complications among the four groups.(6)It is indicated that the application of tranexamic acid in high tibial osteotomy can reduce perioperative bleeding and postoperative blood transfusion rate,and the effect of intravenous infusion combined with drainage tube perfusion is better,which does not increase the incidence of venous thrombosis and incision complications.

2.
Chinese Journal of Biotechnology ; (12): 1216-1222, 2020.
Article Dans Chinois | WPRIM | ID: wpr-826856

Résumé

A rapid and simple method to detect tumor markers in liver cancer was established by combining immunochromatography technique with fluorescent microsphere labeling. According to the principle of double antibody sandwich, the cytoskeleton-associated protein 4 (CKAP4) paired antibody was used as the labeled and coated antibody, and the goat anti-rabbit polyclonal antibody was used as the quality control line coated antibody in the preparation of the CKAP4 fluorescent immunochromatographic test strips. After the preparation, the test strips were evaluated on various performance indicators, such as linearity, precision and stability. The CKAP4 immunochromatographic strip prepared by time-resolved fluorescent microspheres had high sensitivity, and good specificity. Its precision was within 15%, recovery between 85% and 115%, and linear range between 25 and 1 000 pg/mL. The test strip could be kept stable at 37 °C for 20 days, and it correlated well with commercial ELISA kits. The CKAP4 fluorescence immunochromatography method can quantitatively detect the content of CKAP4 in serum. Furthermore, it is rapid, sensitive, simple, economical and single-person operation. This method has the potential of becoming a new method for the diagnosis and treatment of liver cancer.


Sujets)
Animaux , Humains , Anticorps , Métabolisme , Chromatographie d'affinité , Fluorescence , Tumeurs du foie , Diagnostic , Protéines membranaires , Techniques de diagnostic moléculaire , Méthodes , Sensibilité et spécificité
SÉLECTION CITATIONS
Détails de la recherche