Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
China Pharmacist ; (12): 975-977, 2015.
Article Dans Chinois | WPRIM | ID: wpr-669801

Résumé

Objective:To discuss the influence of bifid triple viable enteric-coated capsules on liver function and inflammatory fac-tor in the patients with non-alcoholic steatohepatitis ( NASH) . Methods:Totally 70 cases of patients with NASH were selected and di-vided into the control group and the observation group at random. The patients in the two groups were all given routine hepatoprotective therapy. The patients in the observation group were additionally given 420mg bifid triple viable enteric-coated capsules, three times a day for 4 weeks. Except for bifid triple viable enteric-coated capsules, the patients in the control group were given the same medical treatment as that in the observation group. The changes of liver function index, serum high sensitivity C reaction protein ( hs-CRP) , IL-6 and IL-8 levels in the two groups before and after the medical treatment were observed and the security was compared. Results:After the 4-week medical treatment, ALT, GGT, serum hs-CRP, IL-6 and IL-8 levels in the two groups were obviously declined than those before the treatment (P0. 05). Conclusion:Bifid triple viable enteric-coated capsules in the treatment of NASH can obviously reduce the serum hs-CRP, IL-6 and IL-8 levels, inhibit the intrahepatic inflammation and immunologic injury, and improve the liver function index with high security.

2.
Article Dans Chinois | WPRIM | ID: wpr-541202

Résumé

Objective To investigate lead pollution of drinking water stagnated in household pipe and its characteristic, and provide the scientific basis for safe and health consumption of drinking water. Methods 30 taps in households were randomly chosen as objects. According to the stagnated time the water samples were divided into group A (12-13 hours), group B (7-8 hours) and group C (3-4 hours). The samples were collected in 0 min, 1 min and 2 min after opening taps. Lead levels in the samples were determined by atomic absorption spectrometry (AAS), whose comparative analysis was performed by SPSS software. In total, 320 samples were analyzed. Results In group A, lead concentrations (geometric mean, the same for latter) of water samples in 0 min, 1 min and 2 min were 61.33, 12.27and 5.47 ?g/L respectively, but they were 33.90, 9.13 and 4.59 ?g/L in group B,and 11.37, 6.29 and 4.27 ?g/L in group C. There were significant differences among three groups (P

SÉLECTION CITATIONS
Détails de la recherche