RÉSUMÉ
OBJECTIVES@#To explore the relationship between the frequency characteristics and response threshold of auditory steady-state response (ASSR), auditory brainstem response (ABR) and 40 Hz auditory event related potential (40 Hz AERP), and their application values in forensic medicine.@*METHODS@#Thirty volunteers with normal hearing (60 ears) were selected to perform pure tone audiometry (PTA) threshold and ASSR, ABR and 40 Hz AERP response threshold tests in the standard sound insulation shielding room, and the results were statistically analyzed by SPSS 22.0 software.@*RESULTS@#At 0.5 kHz and 1.0 kHz frequencies, the correlation between 40 Hz AERP response threshold and PTA threshold was good, which was better than that of ASSR and ABR response threshold. At 2.0 kHz and 4.0 kHz frequencies, the correlation between ASSR and ABR response thresholds and PTA threshold was good, which was better than that of 40 Hz AERP response threshold.@*CONCLUSIONS@#To evaluate the hearing at 0.5 kHz and 1.0 kHz frequencies, it is recommended to use 40 Hz AERP and ASSR to comprehensively assess the PTA threshold of the subjects. To evaluate the hearing at 2.0 kHz and 4.0 kHz frequencies, ABR and ASSR are recommended to assess the PTA threshold of subjects comprehensively. The combination of ASSR, ABR and 40 Hz AERP can improve the accuracy of hearing function evaluation.