Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 211
Filtre
1.
Article Dans Chinois | WPRIM | ID: wpr-1027099

Résumé

Objective:To compare the medium and long-term efficacy between the deltoid split approach and the conventional deltopectoral approach in locking plate fixation for proximal humerus fractures.Methods:A retrospective study was performed in the 65 patients with proximal humerus fracture who had been operatively treated at Department of Orthopedics, The Third People's Hospital of Nantong from January 2018 to December 2020. They were 20 males and 45 females with an age of (64.6±9.2) years. Of them, 34 were assigned to fixation with proximal humerus internal locking system (PHILOS) through the deltoid split approach (minimally invasive group), and 31 to PHILOS fixation through the deltopectoral approach (conventional group). The 2 groups were compared in terms of general data, operation time, intraoperative blood loss, hospital stay, fracture union time, intraoperative fluoroscopy, postoperative 2-year imaging scores, and Constant-Murley shoulder score at the last follow-up.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). In the minimally invasive group and the conventional group, respectively, the intraoperative blood loss was (97.9±16.6) mL and (155.8±27.4) mL, and the frequency of intraoperative fluoroscopy (12.0±1.8) times and (6.7±1.8) times, both showing a statistically significant difference ( P<0.05). There was no significant difference in operation time, hospital stay, or fracture union time ( P>0.05). All patients were followed up for (43.9±5.5) months. There was no statistically significant difference between the 2 groups in postoperative 2-year imaging scores ( P>0.05). Compared with the conventional group, patients in the minimally invasive group had significantly lower Constant-Murley strength scores and significantly lower Constant-Murley scores for the Neer four-part fractures ( P<0.05). Postoperatively, one case of screw protrusion and one case of complete ischemic necrosis occurred in both groups while one case of partial ischemic necrosis was observed in the minimally invasive group and 3 cases of partial ischemic necrosis were observed in the conventional group. Conclusions:In locking plate fixation for proximal humerus fractures, compared with the deltopectoral approach, the deltoid split approach shows advantages of less soft tissue damage, less intraoperative bleeding, and less destruction of the blood supply to the humeral head. However, the deltopectoral approach may be more appropriate for the Neer four-part fractures.

2.
Article Dans Chinois | WPRIM | ID: wpr-1027117

Résumé

Objective:To investigate the effectiveness of the modified Bikini approach in the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate.Methods:A retrospective study was conducted to analyze the data of 54 patients with acetabular fracture who had been treated at Department of Trauma Orthopedics, Orthopedic Medical Center, The Third Hospital Affiliated to Southern Medical University from May 2017 to June 2021. The patients were divided into 2 groups based on different surgical approaches: an observation group [26 cases, 6 males, 20 females; aged 40.0 (29.8, 46.8) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the modified Bikini approach, and a control group [28 cases, 10 males, 18 females; aged 34.5 (24.0, 43.5) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the lateral-rectus approach. The incision length, operation time, intraoperative bleeding, length of hospital stay, quality of postoperative fracture reduction, visual analog scale (VAS) for pain, hip function, Vancouver Scar Scale (VSS) and Patient and Observer Scar Assessment Scale (POSAS) were compared between the 2 groups.Results:The differences in the preoperative general data between the 2 groups were not statistically significant, indicating comparability ( P>0.05). There were no statistically significant differences between the 2 groups either in terms of incision length, operation time, intraoperative bleeding, or hospital stay ( P>0.05). The 2 groups were not significantly different in the excellent/good rate of fracture reduction [100.0% (26/26) versus 92.9% (26/28)], VAS at 1 month postoperation [2.0(1.0, 3.0) versus 2.0(1.0, 3.0)], or the modified Merle d'Aubigné and Postel hip score at 12 months postoperation [13.5(12.3, 14.8) versus. 14.0(13.0, 15.0)] ( P>0.05). However, the VSS [4.50(4.00, 6.00)] and POSAS (29.85±10.05) at 12 months postoperation in the observation group were significantly lower than those in the control group [6.50(5.00, 8.25) and 37.11±11.75] ( P<0.05). Conclusion:In the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate, the modified Bikini approach can not only achieve as fine early clinical efficacy as the lateral-rectus approach, but also demonstrate the aesthetic advantages of smaller incision scar and more hidden incision.

3.
Rev. bras. ortop ; 59(1): 107-118, 2024. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1559606

Résumé

Abstract Objective: The present study compared the difference in load and pressure distribution behavior of the blade plate and locked plate for varus osteotomy of the proximal femur per the finite element method. Methods: Modeling was performed by scanning a medium-sized left femur with medial valgus deformity made of polyurethane. Results: The stiffness of the locked plate is higher compared with that of the blade plate. However, this difference was not significant. In addition, the locked plate has proximal locking screws to ensure that the bending moments on the screws are smaller during loading. Conclusion: In summary, both plates are well-established and effective. However, the study using the finite element method plays a fundamental role in understanding the load and pressure distribution of the implant. Moreover, it opens up new possibilities for further studies, including surgical proposals and customized implant materials.


Resumo Objetivo: Testar a diferença do comportamento de distribuição de cargas e pressões da placa lâmina comparativamente com a placa bloqueada para osteotomia varizante do fêmur proximal através do método de elementos finitos. Métodos: A modelagem foi realizada através do escaneamento de um fêmur esquerdo com deformidade medial em valgo fabricado em poliuretano de tamanho médio. Resultados: Como resultados, pode-se inferir que a rigidez da placa bloqueada é maior do que a da placa lâmina. No entanto, essa diferença não foi significativa e, além disso, a placa bloqueada possui parafusos de travamento proximal para garantir que os momentos de flexão que agem nos parafusos sejam ainda menores durante o carregamento. Conclusão: Em síntese, ambos os materiais são consagrados e eficazes para serem utilizados, porém o estudo pelo método de elementos finitos apresenta papel importante para compreendermos a situação de distribuição de cargas e pressões do implante e abre novas possibilidades para novos estudos, como, por exemplo, o estudo da proposta cirúrgica e materiais a serem implantados de forma individual e personalizada.


Sujets)
Humains , Mesure de la douleur , Entretiens comme sujet , Enquêtes et questionnaires , Syndrome douloureux régional complexe , Ostéosynthèse
4.
Odontol. vital ; (39): 27-39, jul.-dic. 2023. tab, graf
Article Dans Espagnol | LILACS, SaludCR | ID: biblio-1550585

Résumé

RESUMEN Introducción: Los tratamientos para fracturas de órbita se basan en la corrección del defecto de las lesiones orbitarias de tipo blow in y blow out (o de estallido), mediante diversas placas y mallas biocompatibles con el organismo, dándose una cicatrización de primera generación evitando un callo óseo y una fijación más rígida. Para el diagnóstico de este tipo de lesiones tenemos inflamación periorbitaria, enoftalmos, diplopía, equimosis, hemorragia subconjuntival. Existen diversos materiales reconstructivos siendo estos compuestos por distintas materias primas, como son los aloplásticos y autógenos; donde encontramos varios tipos como placas de titanio y las placas reabsorbibles siendo estas las más comunes y usadas actualmente, por su bajo estímulo a reabsorciones óseas y evitando efectos secundarios a largo plazo. Estas placas presentan diversos grados de ductilidad y resistencia. Se informó sobre varias complicaciones según el tipo de placas como es la cicatrización, las cirugías postquirúrgicas en caso de placas de titanio, etc. El objetivo de esta revisión es la evaluación de la eficacia las placas reabsorbibles versus placas de titanio en fracturas de órbita. Materiales y métodos: La investigación es de carácter documental, descriptivo y no experimental. En el cual se emplea una metodología de identificación e inclusión de artículos científicos tipo prisma. Resultados y conclusiones: Se verificaron las ventajas y desventajas tanto de las placas reabsorbibles como las de titanio siendo estas similares en la biocompatibilidad con el organismo humano, así como también varias diferencias como el soporte, fuerzas, resistencia de estas, concluyendo que es debatible el material ideal para tratar fracturas de órbita. Se seleccionaron artículos tomando en cuenta el título y objetivos; considerando estudios comparativos, revisiones sistemáticas, revisiones de literatura, los cuales comprendían criterios con respecto a fracturas de órbita y tratamientos quirúrgicos. La búsqueda arrojó 55 artículos en PubMed, 65 en Google, 4 en Scielo y 29 en Science direct, de los cuales se excluyeron libros, monografías, estudios experimentales, dando como resultado 21 artículos para el desarrollo de esta revisión bibliográfica. Y que fueron leídos y analizados en su totalidad, estudiando los objetivos, metodología y conclusión de cada uno de ellos para la posterior comparación.


ABSTRACT Introduction: Treatments for orbit fractures are based on the correction of the defect of blow in and blow out orbital injuries, by means of various plates and meshes biocompatible with the organism, giving a first-generation healing avoiding a bony callus and a more rigid fixation. For the diagnosis of this type of lesions we have periorbital inflammation, enophthalmos, diplopia, ecchymosis, subconjunctival hemorrhage. There are several reconstructive materials being these composed of different raw materials, such as alloplastic and autogenous, where we find several types such as titanium plates and resorbable plates being these the most common and currently used, for its low stimulus to bone resorption and avoiding long-term side effects. These plates have different degrees of ductility and resistance. Several complications have been reported depending on the type of plates, such as scarring, post-surgical surgeries in the case of titanium plates, etc. The objective of this review is to evaluate the efficacy of resorbable versus titanium plates in orbital fractures. Materials and methods: This research are a documentary, descriptive and non-experimental nature. A prism-type methodology of identification and inclusion of scientific articles was used. Results and conclusions: The advantages and disadvantages of both resorbable and titanium plates were verified, being these similar in biocompatibility with the human organism, as well as several differences such as support, forces, resistance of the same, concluding that it is debatable. The ideal material to treat orbital fractures. Articles were selected considering the title and objectives; considering comparative studies, systematic reviews, literature reviews, which included criteria regarding orbital fractures and surgical treatments. The search yielded 55 articles in PubMed, 65 in Google, 4 in Scielo and 29 in Science direct, from which books, monographs, experimental studies were excluded, resulting in 21 articles for the development of this bibliographic review. The 21 articles were read and analyzed in their entirety, studying the objectives, methodology and conclusion of each one of them for subsequent comparison.


Sujets)
Humains , Orbite/traumatismes , Plaques orthopédiques , Titane , Matériaux biocompatibles/usage thérapeutique , Fractures osseuses/chirurgie
5.
Rev. bras. ortop ; 58(2): 326-330, Mar.-Apr. 2023. tab
Article Dans Anglais | LILACS | ID: biblio-1449798

Résumé

Abstract Objective Medial open wedge high tibial osteotomy (MOWHTO) significantly relieves pain in the medial joint line in medial compartment osteoarthritis of the knee. But some patients complain of pain over the pes anserinus even 1 year after the osteotomy, which may require implant removal for relief. This study aims to define the implant removal rate after MOWHTO due to pain over the pes anserinus. Methods One hundred and three knees of 72 patients who underwent MOWHTO for medial compartment osteoarthritis between 2010 and 2018 were enrolled in the study. Knee injury and osteoarthritis outcome score (KOOS), Oxford knee score (OKS), and visual analogue score (VAS) were assessed for pain in the medial knee joint line (VAS-MJ) preoperatively, 12 months postoperatively, and yearly thereafter; adding VAS for pain over the pes anserinus (VAS-PA). Patients with VAS-PA ≥ 40 and adequate bony consolidation after 12 months were recommended implant removal. Results Thirty-three (45.8%) of the patients were male and 39 (54.2%) were female. The mean age was 49.4 ± 8.0 and the mean body mass index was 27.0 ± 2.9. The Tomofix medial tibial plate-screw system (DePuy Synthes, Raynham, MA, USA) was used in all cases. Three (2.8%) cases with delayed union requiring revision were excluded. The KOOS, OKS, and VAS-MJ significantly improved 12 months after MOWHTO. The mean VAS-PA was 38.3 ± 23.9. Implant removal for pain relief was needed in 65 (63.1%) of the103 knees. The mean VAS-PA decreased to 4.5 ± 5.6 3 months after implant removal (p < 0.0001). Conclusion Over 60% of the patients may need implant removal to relieve pain over the pes anserinus after MOWHTO. Candidates for MOWHTO should be informed about this complication and its solution.


Resumo Objetivo A osteotomia tibial alta com cunha de abertura medial (MOWHTO, do inglês medial open wedge high tibial osteotomy) alivia de forma significativa a dor na linha articular medial em casos de osteoartrite do compartimento medial do joelho. Alguns pacientes, porém, se queixam de dor nos tendões dos músculos sartório, grácil e semitendinoso (pata de ganso) mesmo 1 ano após a osteotomia, o que pode exigir a remoção do implante. Este estudo define a taxa de remoção do implante após a MOWHTO devido à dor nos tendões dos músculos sartório, grácil e semitendinoso. Métodos Cento e três joelhos de 72 pacientes submetidos à MOWHTO para tratamento da osteoartrite do compartimento medial entre 2010 e 2018 foram incluídos no estudo. A pontuação de desfecho de lesão no joelho e osteoartrite (KOOS, do inglês Knee Injury and Osteoarthritis Outcome Score), a pontuação dejoelho de Oxford (OKS, do inglês Oxford Knee Score) e a escala visual analógica (EVA) de dor na linha articular medial do joelho (EVA-MJ) foram avaliados antes da cirurgia. A EVA nos tendões dos músculos sartório, grácil e semitendinoso (EVA-PA) foi adicionada a essas avaliações, também realizadas 12 meses após o procedimento e, a seguir, anualmente. A remoção do implante foi recomendada em pacientes com EVA-PA ≥ 40 e consolidação óssea adequada em 12 meses. Resultados Trinta e três (45,8%) pacientes eram homens e 39 (54,2%), mulheres. A média de idade foi de 49,4 ±8,0, e o índice de massa corpórea (IMC) médio foi de 27,0 ± 2,9. O sistema placa-parafuso tibial medial Tomofix (DePuy Synthes, Raynham, MA, EUA) foi utilizado em todos os casos. Três (2,8%) casos foram excluídos devido ao retardo de consolidação e à necessidade de revisão. Os resultados nas escalas KOOS, OKS e EVA-MJ melhoraram significativamente 12 meses após a MOWHTO. A EVA-PA média foi de 38,3 ± 23,9. A remoção do implante para alívio da dor foi necessária em 65 (63,1%) dos 103 joelhos. Três meses após a remoção do implante, a EVA-PA média diminuiu para 4,5 ± 5,6 (p < 0,0001). Conclusão A remoção do implante pode ser necessária em mais de 60% dos pacientes para alívio da dor nos tendões dos músculos sartório, grácil e semitendinoso após a MOWHTO. Os candidatos à MOWHTO devem ser informados sobre esta complicação e sua resolução.


Sujets)
Humains , Ostéotomie , Infection de plaie opératoire , Tibia/chirurgie , Plaques orthopédiques , Transplantation osseuse , Ablation de dispositif
6.
Article Dans Chinois | WPRIM | ID: wpr-992694

Résumé

Objective:To design an anatomical plate of ulna coronoid process using 3D printing and computer model design software based on a collection of CT scanning data of the ulna coronoid process.Methods:The CT scans of the elbow joint with no obvious anatomic variation, no fracture, or no history of elbow operation were collected which had been taken at Trauma Center, The First Affiliated Hospital of Kunming Medical University from September 2017 to January 2022. There were 52 males and 50 females. RadiAnt DICOM Viewer and Mimics Medical 21.0 were used to visualize the CT data of the elbow joint of 102 volunteers. The software was used to measure the angle between the tip of the ulna coronoid process and the tuberosity of the ulna, the width at 1/2 height of the ulna coronoid process, the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity, and the safety angle for screw placement. After the values were measured, Siemens Ungraphics NX12.0 software was used to design the anatomical plate and the screw guide device of the ulna coronoid process. After the plate model was designed, a 1:1 actual plate model of the ulna coronoid process was produced by 3D printing. The actual plate model was placed onto an adult model of the ulna coronoid process and an adult cadaveric specimen of the ulna coronoid process to verify its matching degree. An in vitro operation was simulated using the plate model to verify its operability. Results:There were no significant differences between the left and right sides in the angle between the tip of the ulna coronoid process and the tuberosity of the ulna, the width at 1/2 height of the ulna coronoid process, the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity, or the safety angle for screw placement in either males or females ( P>0.05). There were no significant differences between males and females in the angle between the tip of the ulna coronoid process and the tuberosity of the ulna or in the safety angle for screw placement ( P>0.05). There were statistically significant differences between males and females in the width of 1/2 height of the ulna coronoid process and the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity ( P<0.05). However, the experiments on computer simulative adaptation and plate model simulative adaptation found that the anatomical plates of the ulna coronoid process designed on various parameters of males and females were exchangeable, leading to similarly good marching degrees and safe angles for screw placement. Conclusions:The anatomical plate of the ulna coronoid process designed in this study demonstrates a good fit and a safe angle for screw placement, basically achieving the goal expected to provide a basis for fabrication of a titanium alloy plate. In design of an anatomical plate of ulna coronoid process, it is not necessary to differentiate males from females or to differentiate the left side from the right one, because only a general plate can be used for both males and females and for both the left and the right sides.

7.
Article Dans Chinois | WPRIM | ID: wpr-992727

Résumé

Objective:To compare the clinical effects between proximal humerus internal locking system (PHILOS) inverted and a posterior single plate in the anterior percutaneous minimally invasive internal fixation for distal humeral shaft fractures.Methods:A retrospective study was conducted to analyze the data of 65 patients with distal humeral shaft fracture who had been treated from January 2018 to May 2021 at Department of Orthopaedics, The Second Hospital of Fuzhou. The patients were assigned into 2 groups according to different treatment methods. In the observation group of 30 cases subjected to anterior percutaneous minimally invasive internal fixation with PHILOS inverted: 20 males and 10 females with an age of (41.5±11.6) years; type A in 5 cases, type B in 14 cases, and type C in 11 cases by AO fracture classification. In the control group of 35 cases subjected to anterior percutaneous minimally invasive internal fixation with a posterior single plate: 23 males and 12 females with an age of (39.9±11.2) years; type A in 7 cases, type B in 17 cases, and type C in 11 cases by AO fracture classification. The preoperative general data, operation time, intraoperative blood loss, total incision length, fracture healing time, and shoulder and elbow VAS scores, Constant-Murley shoulder function score, Mayo elbow performance score (MEPS), and complications at the last follow-up were recorded and compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). There were no significant differences either in operation time, fracture healing time, or shoulder or elbow VAS pain score, Constant-Murley shoulder function score, or MEPS at the last follow-up between the 2 groups ( P>0.05). The intraoperative blood loss was (59.7±26.6) mL in the observation group and (165.7±86.4) mL in the control group, and the total incision length was (10.7±2.1) cm in the observation group and (18.6±2.7) cm in the control group, showing statistically significant differences between the 2 groups ( P<0.01). There was no injury to the radial nerve or musculocutaneous nerves, incision infection or fracture nonunion in the observation group. There were 4 cases of iatrogenic radial nerve injury, 2 cases of incision infection and 1 case of fracture nonunion in the control group, yielding a complication rate of 20.0% (7/35). The difference in the incidence of complications was significant between the 2 groups ( P<0.01). Conclusion:In the treatment of distal humeral shaft fracture with anterior percutaneous minimally invasive internal fixation, PHILOS inverted has advantages of less soft tissue damage, less intraoperative bleeding, and a lower risk of iatrogenic radial nerve injury than the posterior single plate.

8.
Article Dans Chinois | WPRIM | ID: wpr-992739

Résumé

Objective:To evaluate our self-designed pubic symphysis orthotic compression anatomic plate (PSOCAP) in the treatment of fractures and dislocations around the pubic symphysis.Methods:A retrospective study was conducted to analyze the 16 patients with fracture or dislocation around the pubic symphysis who had been treated by our self-designed PSOCAP at Department of Traumatic Surgery, Center for Orthopaedic Surgery, The Third Hospital Affiliated to Southern Medical University from January 2021 to June 2022. There were 8 males and 8 females with an age of (41±19) years. According to the Tile classification for pelvic fractures, there were 3 cases of type B1, 2 cases of type B3, 1 case of type C1.2, 4 cases of type C1.3, 3 cases of type C2, and 3 cases of type C3. There were 8 cases of pubic symphysis separation and 8 fractures of the pubic ramus (2 ones at Nakatani zone Ⅰ and 6 ones at Nakatani zone Ⅱ). Time from injury to surgery was 16 (11, 53) days, ranging from 4 to 348 days. The fractures or dislocations around the pubic symphysis were exposed by the modified Stoppa approach, reduced with the assistance of PSOCAP and fixated with PSOCAP; the posterior pelvic ring was reduced and fixated by corresponding surgical methods. Recorded were the surgical time, intraoperative bleeding, postoperative quality of fracture reduction, surgical complications, and functional recovery at the last follow-up concerning the pelvic anterior ring.Results:Surgery went on successfully in the 16 patients. Their surgical time was (58±15) min, ranging from 40 to 90 min, and their intraoperative bleeding 85 (63, 150) mL, ranging from 50 to 250 mL. According to the Matta scoring, the fracture reduction was evaluated as excellent in 10 cases, as good in 3 cases and as fair in 3 cases. The (10±3)-month follow-up for the 16 patients revealed complete fracture union for all after (12±2) weeks. According to the Majeed scoring at the last follow-up, the pelvic function was evaluated as excellent in 5 cases, as good in 7 cases, and as fair in 4 cases. No such postoperative complications as fracture displacement or internal fixation failure occurred.Conclusion:Owing to the biplane and integrated structure, our self-designed PSOCAP can help reduce the fractures or dislocations around the pubic symphysis to achieve anatomical reduction and strong internal fixation, leading to good clinical efficacy.

9.
Article Dans Chinois | WPRIM | ID: wpr-992772

Résumé

Objective:To investigate the efficacy of Masquelet induced membrane technique combined with an external locking plate in the treatment of infectious bone defects of the tibia.Methods:A retrospective study was conducted to analyze the data of 32 patients with infectious bone defects of the tibia who had been treated by Masquelet induced membrane technique combined with an external locking plate at Department of Orthopaedic Surgery, The Fourth Hospital of Wuhan from January 2011 to January 2021. There were 22 males and 10 females, with an age of (43.2±13.1) years. The length of bone defects was (5.1±1.3) cm. By the Cierny-Mader classification, there were 12 cases of type Ⅲ and 20 cases of type Ⅳ. The defects were located at the proximal tibia in 11 cases, at the middle tibia in 12, and at the distal tibia in 9. At the last follow-up, the lower limb function was evaluated by the Paley scale, and the quality of life by the 36-Item Short Form Health Survey (SF-36).Results:All the 32 patients were followed up for (21.2±5.7) months. Normal healing was achieved in 30 cases but delayed healing occurred in 2 cases. The external plate and screws were removed at (23.1±4.6) weeks after operation. There was no infection in the original surgical incision or no injury to the nerve, blood vessel or tendon after operation, but nail tract infection occurred more or less in 3 cases. According to the Paley scale at the last follow-up, the lower limb function was evaluated as excellent in 22 cases, as good in 8, and as fair in 2, giving an excellent and good rate of 93.75% (30/32). The SF-36 quality of life score was (88.9±3.8) points.Conclusion:In the treatment of infectious bone defects of the tibia, Masquelet induced membrane technique combined with an external locking plate can achieve satisfactory clinical outcomes due to its effective control of infection, reduction in delayed healing, good stability and good patient tolerance.

10.
Acta ortop. bras ; 31(spe1): e252977, 2023. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1429579

Résumé

ABSTRACT Objectives: This study aimed to compare the functional and radiological results of patients who had intra-articular comminuted distal radius fractures and were operated on with external fixation percutaneous pinning or the volar-dorsal combined plate osteosynthesis. Methods: In this study, 49 patients operated on and followed up for the comminuted distal radius fractures between May 2015 and January 2019 were retrospectively evaluated. The surgical outcomes of the patients, who were operated on with combined dorsal-volar plate osteosynthesis or external fixation percutaneous pinning, were compared in this study. Functional and radiological scores were evaluated and analyzed statistically. Results: There was no statistical difference between external fixation and volar-dorsal combined plate groups regarding the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, the Visual Analog Scale (VAS), the Mayo scoring system, range of motion, and grip strength values. Discussion: Although the combined volar-dorsal plate osteosynthesis technique had a longer operation time and a more complicated surgical procedure, the combined volar-dorsal plate osteosynthesis had lower complication rates and permitted early mobilization. The combined volar-dorsal plate osteosynthesis could be an alternative to external fixation percutaneous pinning. Level of Evidence III, Therapeutic Studies Investigating the Results of Treatment.


RESUMO Objetivo: O objetivo deste estudo foi comparar os resultados funcionais e radiológicos de pacientes portadores de fraturas intra-articulares cominutivas do rádio distal, operados com fixação externa percutânea ou com osteossíntese volar-dorsal de placa combinada. Método: Foram avaliados 49 pacientes operados e acompanhados por fraturas cominutivas distais do rádio entre maio de 2015 e janeiro de 2019 retrospectivamente. Os resultados cirúrgicos dos pacientes operados com osteossíntese de placa volar-dorsal combinada ou fixação externa percutânea foram comparados. Os escores funcionais e radiológicos foram avaliados e analisados estatisticamente. Resultados: Não houve diferença estatística entre os grupos de fixação externa e placa combinada volar-dorsal em relação ao questionário Deficiências do braço, ombro e mão (DASH), à Escala Visual Analógica (VAS), ao sistema de pontuação Mayo, à amplitude de movimento ou à avaliação de força de preensão. Conclusão: Embora a técnica combinada de osteossíntese da placa volar-dorsal tenha um tempo cirúrgico mais longo e procedimento mais complicado, a osteossíntese combinada da placa volar-dorsal apresentou menores taxas de complicações, permitindo a mobilização precoce. A osteossíntese combinada da placa volar-dorsal pode ser uma alternativa à fixação externa percutânea. Nível de Evidência III, Estudos terapêuticos - Investigação dos resultados do tratamento.

11.
Article Dans Chinois | WPRIM | ID: wpr-1027069

Résumé

Objective:To compare proximal humerus internal locking system (PHILOS) and Multiloc intramedullary nail in the treatment of proximal humerus fracture-anterior dislocation.Methods:A retrospective study was performed to analyze the data of 33 patients with proximal humerus fracture-anterior dislocation who had been treated by open reduction and internal fixation from June 2015 to April 2021 at Department of Upper Limbs, Zhengzhou Orthopaedic Hospital. According to methods of internal fixation, the patients were divided into an extramedullary group and an intramedullary group. In the extramedullary group of 18 cases subjected to internal fixation with PHILOS, there were 8 males and 10 females with an age of (53.3 ± 10.6) years, and 1 2-part fracture, 15 3-part fractures and 2 4-part fractures by the Neer classification. In the intramedullary group of 15 cases subjected to internal fixation with Multiloc intramedullary nail, there were 8 males and 7 females with an age of (51.5 ± 11.2) years, and 14 3-part fractures and 1 4-part fracture by the Neer classification. The 2 groups were compared in terms of incision length, operation time, intraoperative blood loss, postoperative complications, and visual analog scale (VAS), range of shoulder motion, and Constant-Murley score at postoperative 12 months.Results:The 2 groups were comparable due to insignificant differences in their preoperative general data ( P>0.05). All patients were followed up for (20.8 ± 4.7) months. The incision length in the intramedullary group [(11.6 ± 1.7) cm] was significantly shorter than that in the extramedullary group [(17.6 ± 2.0) cm], and the intraoperative blood loss in the former [(106.7 ± 34.4) mL] was significantly lower than that in the latter [(151.7 ± 45.7) mL] ( P<0.05). The VAS scores at 1 week and 1 month after surgery [2.0 (2.0, 3.0) and 0.0 (0.0, 1.0) respectively] in the intramedullary group were significantly lower than those in the extramedullary group [3.0 (3.0, 3.3) and 1.0 (0.0, 1.3) respectively] ( P<0.05). The external rotation of the shoulder at the last follow-up in the intramedullary group (65.3° ± 15.5°) was significantly larger than that in the extramedullary group (50.6° ± 13.9°) ( P<0.05). There were no significant differences in operation time, incidence of postoperative complications, VAS score at 12 months after operation, Constant-Murley score or range of shoulder motion at the last follow-up between the 2 groups ( P>0.05). Conclusions:In the treatment of proximal humerus fracture-anterior dislocation, open reduction and internal fixation with both PHILOS and Multiloc intramedullary nail can result in a favorable prognosis when the fracture-dislocation is well reduced and fixated. However, the Multiloc intramedullary nail may lead to better early pain relief, less surgical invasion, and better functional recovery of the external rotation of the shoulder.

12.
Article Dans Chinois | WPRIM | ID: wpr-1027086

Résumé

Objective:To observe the curative effects and complications of open reduction and fixation with cannulated screws and an augmented plate for Pauwels type Ⅲ femoral neck fractures.Methods:A retrospective study was conducted to analyze the data of 8 patients with fresh Pauwels Ⅲ femoral neck fracture who had been treated from January 2015 to October 2018 at Department of Trauma and Orthopaedics, Xinjiang Uygur Autonomous Region Hospital of Traditional Chinese Medicine. There were 7 males and 1 female with an age of (47.7±14.0) years. The Pauwels angle ranged from 50° to 70° in 6 cases and was >70° in 2 cases. As the original closed reduction was not ideal in all the patients, open reduction via the modified Smith-Petersen approach and fixation with cannulated screws and an augmented plate were performed. Fracture healing, Harris hip score, and complications were followed up at 1 month, 6 months, 1 year, and 3 years postoperatively.Results:At 1 month after operation: 8 patients were followed up, their Harris hip score was (38.4±3.6) points, and there were 7 cases of femoral neck shortening and 1 case of incision fat liquefaction. At 6 months after operation: 7 patients were followed up, their Harris hip score was (70.6±2.8) points, and 1 patient healed anatomically, 4 patients healed with shortening, and 2 patients healed with delay and shortening. Femoral neck shortening, withdrawal of cannulated screws, and screw loosening within the augmented plate were all increased compared with 1 month after operation. At 1 year after operation: 7 patients were followed up, their Harris hip score was (85.5±4.4) points, there were no significant changes in fracture healing or complications compared with 6 months after operation. At 3 years after operation: the patient lost to prior follow-up died of heart disease 34 months after operation, 1 patient had to undergo total hip arthroplasty due to fracture nonunion and cutout of cannulated screws at 16 months after operation, and the other 6 patients had a Harris hip score of (93.6±2.5) points. Of the 6 patients, femoral neck fracture healed in 5 (shortening healing in 4, including 1 case complicated with femoral head necrosis, and anatomical healing in 1) but did not in one.Conclusions:In the treatment of Pauwels type Ⅲ femoral neck fractures, open reduction and fixation with cannulated screws and an augmented plate does not lead to ideal curative effects. The main complication is shortening of the femoral neck. The auxiliary role of augmented plate fixation is not obvious.

13.
Rev. bras. ortop ; 58(6): 896-904, 2023. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1535608

Résumé

Abstract Objective Various modalities have been suggested to manage mallet fractures; however, inappropriate treatment can lead to extension lag, a swan neck deformity, or arthritis of the distal interphalangeal joint (DIPJ). The current study aimed to evaluate the results (functional, radiological, and complications) of open reduction and internal fixation (ORIF) of mallet fractures using low-cost hook plates fabricated from low-profile titanium mini plates. Methods A prospective case series of 17 consecutive patients (average age of 32.3 years) with mallet fractures (six were Wehbe Type IB and 11 were Wehbe Type MB). Eleven (64.7%) were males. The affected hand was dominant in all patients, and the affected digit was the index in 6 (35.3%), the ring in 5 (29.4%), the small in 3 (17.65%), and the middle in 3 (17.65%) patients. The same fellowship-trained hand surgeon performed all surgeries. Results The average operative time was 37.65 minutes. After an average follow-up of 10.94 months (range 6-27), the average DIPJ motion was 50º º (range 20º-70º), the extensor lag was noted in 4 (23.5%) patients, and complications were reported in 6 (35.29%) patients. According to Crawford criteria, 6 (35.3%) patients achieved excellent results, 7 (41.2%) achieved good results, and 4 (23.5%) achieved fair results. Conclusion The modified hook plate technique for fixation of mallet fractures is a beneficiai, economical, yet demanding technique that adequately provides stable fixation to allow early DIPJ motion with acceptable functional outcomes.


Resumo Objetivo Diversas modalidades têm sido sugeridas para o tratamento de fraturas em martelo; no entanto, o tratamento inadequado pode causar retardo de extensão, deformidade em pescoço de cisne ou artrite da articulação interfalangiana distal (AIFD). Este estudo teve como objetivo avaliar os desfechos (funcionais, radiológicos e complicações) da redução aberta e fixação interna (RAFI) das fraturas em martelo com placas de gancho de baixo custo fabricadas com mini placas de titânio de baixo perfil. Métodos Série de casos prospectivos de 17 pacientes consecutivos (idade média de 32,3 anos) com fraturas em martelo (seis do tipo IB e 11 do tipo IIB de Wehbe). Onze (64,7%) pacientes eram do sexo masculino. A mão acometida era a dominante em todos os pacientes, com acometimento do dedo indicador em seis (35,3%), anelar em cinco (29,4%), mínimo em três (17,65%) e médio em três (17,65%) pacientes. O mesmo cirurgião de mão experiente realizou todas as cirurgias. Resultados O tempo operatório médio foi de 37,65 minutos. Após um acompanhamento médio de 10,94 meses (intervalo de 6 a 27), observou-se movimento médio da AIFD de 50º (intervalo de 20º a 70º), retardo de extensão em quatro (23,5%) pacientes e complicações em seis (35,29%) pacientes. De acordo com os critérios de Crawford, os desfechos foram excelentes em seis (35,3%), bons em sete (41,2%) e regulares em quatro (23,5%) pacientes. Conclusão A técnica da placa de gancho modificada para fixação de fraturas em martelo é benéfica e econômica, mas exigente; permite fixação estável e adequada para permitir a movimentação precoce da AIFD com desfechos funcionais aceitáveis.


Sujets)
Humains , Plaques orthopédiques , Fractures osseuses , Traumatismes du doigt , Articulation du doigt , Ostéosynthèse interne
14.
Rev. bras. ortop ; 57(6): 899-910, Nov.-Dec. 2022. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1423637

Résumé

Abstract Objective Over the last decades, volar locking plates (VLPs) have been the mainstay treatment for distal radius fractures (DRFs). With the growing body of evidence, we systematically reviewed studies on recent VLP modifications. Methods A systematic search was performed in the PubMed/MEDLINE database for studies published in English in the past five years. The inclusion criteria were randomized controlled trials (RCTs) on the operative treatment of DRFs. We excluded ongoing trials and studies not directly addressing DRF. The primary outcomes assessed were subjective (such as the scores on the Disabilities of the Arm, Shoulder and Hand [DASH] questionnaire, the Patient-rated Wrist Evaluation [PRWE], the European Quality of Life-5 Dimensions [EQ-5D], the 36-item Short Form Health Survey [SF-36], and the Visual Analog Scale [VAS]) and objective clinical outcomes (the complication rate). Results We identified 29 articles published from 2016 to 2020 with high quality of evidence, except for one, which had evidence of moderate quality. In total, 3,079 DRFs were analyzed in the present study. All studies except one had a greater proportion of female participants, and only in 1 study the mean age of the sample was < 40 years old. There were no significant differences between the VLP and external fixation (EF) in terms of the scores on the DASH (p= 0.18) and PRWE (p= 0.77). The VLP alone without pronator quadratus (PQ) repair yielded significantly better outcomes. Conclusion In unstable fractures, the VLP and EF yielded comparable long-term results. There is no clear benefit of adding PQ repair to current the VLP surgical technique. Level of EvidenceLevel I


Resumo Objetivo Nas últimas décadas, a placa volar bloqueada (PVB) tem sido o tratamento principal para fraturas do rádio distal (FRDs). Com o crescente conjunto de evidências, revisamos sistematicamente estudos sobre modificações recentes na PVB. Métodos Uma pesquisa sistemática foi realizada utilizando o banco de dados PubMed/MEDLINE por estudos publicados em inglês nos últimos cinco anos. Os critérios de inclusão foram ensaios clínicos controlados e randomizados (ECCRs) sobre o tratamento cirúrgico de FRDs. Excluímos ensaios e estudos em andamento que não abordavam diretamente a FRD. Os desfechos primários avaliados foram desfechos clínicos subjetivos (como as pontuações no questionário de Deficiências do Braço, Ombro e Mão [Disabilities of the Arm, Shoulder and Hand, DASH, em inglês], na Avaliação do Punho Classificada pelo Paciente [Patient-rated Wrist Evaluation, PRWE, em inglês], no questionário Qualidade de Vida Europeia - 5 Dimensões [European Quality of Life-5 Dimensions, EQ-5D, em inglês], na Pesquisa de Saúde por Formulário Curto de 36 Itens [36-item Short Form Health Survey, SF-36, em inglês], e na Escala Visual Analógica [EVA]) e objetivos (taxa de complicações). Resultados Identificamos 29 artigos publicados entre 2016 e 2020 com alta qualidade de evidência, exceto por um, de qualidade moderada. Ao todo, foram analisadas 3.079 FRDs neste estudo, Todos os estudos analisados, exceto por um, tinham maior proporção de participantes do gênero feminino, e somente em 1 estudo a idade média da amostra foi < 40 anos. Não houve diferença significativa entre a PVB e fixação externa (FE) em termos das pontuações no DASH (p= 0,18) e na PRWE (p= 0,77). Os resultados da PVB isolada, sem qualquer reparo do pronador quadrado (PQ), foram significativamente melhores. Conclusão Em fraturas instáveis, a PVB e a FE produziram resultados comparáveis no longo prazo. Não há um benefício claro em se adicionar reparo do PQ à técnica cirúrgica atual da PVB. Nível de EvidênciaNível I


Sujets)
Fractures du radius/chirurgie , Traumatismes du poignet/chirurgie , Plaques orthopédiques , Fixateurs externes
15.
Rev. bras. ortop ; 57(2): 295-300, Mar.-Apr. 2022. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1387981

Résumé

Abstract Objective To analyze the radiological, clinical, and functional outcomes of clavicle fractures treated with the minimally-invasive plate osteosynthesis (MIPO) technique. Methods From June 2018 to July 2019, 17 cases of clavicular fractures were managed using the MIPO technique under C-arm fluoroscopy. The functional outcomes were assessed using the Constant-Murley score and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. The clinical results of union, the complications, the operative time, the hospital stay, as well as infection, were analyzed. Results The mean follow-up time was of 10.41 1.75 months (range: 8 to 14 months). There were 11 male and 6 female patients, with a mean age of 39.05 10.76 years (range: 22 to 57 years). All fractures united on the mean time of 15.35 3.08 weeks (range: 12 to 20 weeks). The mean operative time was of 98.11 13.83 minutes (range: 70 to 130 minutes), and the mean length of the hospital stay was of 4.7 1.12 days (range: 3 to 7 days). The mean Constant-Murley score was of 74.82 6.36 in 4th postoperstive month, and of 92.35 5.48 in the 8th postoperative month, which was statistically significant. The mean DASH score was of 9.94 1.55 in the 4th postoperative month, and of 5.29 1.85 in the 8th postoperative month, which was also statistically significant. One patient had superficial skin infection at the site of the incision. Conclusions The MIPO technique is an alternative method for the fixation of clavicle fractures, but it is technically more demanding, and requires well-equipped operating room facilities.


Resumo Objetivo Analisar o resultado radiológico, clínico e funcional das fraturas da clavícula, tratadas pela técnica de osteossíntese com placa minimamente invasiva (MIPO). Métodos De junho de 2018 a julho de 2019, um total de 17 casos de fraturas claviculares foram tratadas com a técnica de osteossíntese com placa minimamente invasiva (MIPO), sob fluoroscopia com o braço em C. Os resultados funcionais foram avaliados por meio do escore de Constant-Murley e pelo escore de incapacidade do braço, ombro e mão (DASH). Foram analisados os resultados clínicos de consolidação, complicações, tempo cirúrgico, permanência hospitalar e infecção. Resultados O tempo médio de acompanhamento neste estudo foi de 10,41 1,75 meses (variação, 8 a 14 meses). Havia 11 pacientes do sexo masculino e seis do feminino, com média de idade de 39,05 10,76 anos (variação de 22 a 57 anos). Todas as fraturas se consolidaram no tempo médio de 15,35 3,08 semanas (variação, 12 a 20 semanas). O tempo cirúrgico médio foi de 98,11 13,83 minutos (variação, 70 a 130), sendo a permanência hospitalar média de 4,7 1,12 dias (variação de 3 a 7). O escore de Constant-Murley médio foi de 74,82 6,36 no 4° mês e 92,35 5,48 no 8° mês do pós-operatório, o que foi estatisticamente significativo. O escore DASH médio foi de 9,94 1,55 no 4° mês e 5,29 1,85 na 8ª semana do pós-operatório, também sendo estatisticamente significativo. Um paciente apresentou infecção cutânea superficial no local da incisão. Conclusões A técnica MIPO é um método alternativo para a fixação de fraturas da clavícula, porém é tecnicamente mais desafiador, já que necessita de instalações cirúrgicas mais bem equipadas.


Sujets)
Humains , Mâle , Femelle , Clavicule/chirurgie , Clavicule/traumatismes , Interventions chirurgicales mini-invasives , Ostéosynthèse interne , Durée du séjour
16.
Rev. Col. Bras. Cir ; 49: e20223177, 2022. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1376237

Résumé

ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss' Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones.


RESUMO Objetivo: verificar como as placas superiores pré-moldadas disponíveis no mercado se adaptam às fraturas do terço médio da clavícula. Método: 100 clavículas de cadáveres foram avaliadas por três observadores distintos, aplicando-se o escore de congruência da clavícula e comparando quatro sistemas diferentes de placas bloqueadas anatômicas pré-moldadas de seis a oito furos. Resultados: a concordância interobservador foi considerada moderada pelo percentual de concordância e regular pelo índice Kappa de Fleiss, sem diferenças significativas entre as avaliações. Apenas uma das oito placas apresentou encaixe anatômico maior que 70%. As placas longas (oito furos) apresentaram um encaixe ruim em comparação com as placas curtas (seis ou sete furos). Conclusões: os sistemas de placa superior pré-moldadas disponíveis atualmente fornecem um encaixe inadequado às clavículas para fixações de fraturas do terço médio. Placas longas apresentam um encaixe pior que as curtas.

17.
Acta ortop. bras ; 30(5): e257953, 2022. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1403044

Résumé

ABSTRACT Objective: To evaluate the volar cortical angle (VCA), the variation in lateral and intermediate columns, the shape and pattern of the watershed line (WL) of the distal radius and its correlation with locking volar plates available. Methods: 27 human cadaveric radial bones of the Department of Morphology and nine locking volar plates of six different companies were analyzed. VCA were measured from lateral and intermediate columns and their corresponding values on plates, as well as comparing the relief of radius and plates. In the WL analysis, we compared the standard format found on the radius and its equivalent on plates and divided into four types: biconvex, convex, ulnar convex and plan. Results: VCA varied between columns of the distal radius extremity. The mean in the lateral column was 153.40 degrees and 146.06 degrees in the intermediate. Four of nine plates showed no variation in volar angulation. From 27 distal radius, 13 showed convex pattern and 12 had biconvex, whereas most plates (seven of the nine analyzed) were biconvex drawing. Conclusion: Radial bone anatomy was variable. The intermediate column was, on average, steeper than lateral column. Synthes®-2 plate presented the closest design to the anatomy of the distal end of the radial bone, followed by Newclip®-2 plate. Level of Evidence II, Anatomic and Descriptive Study.


RESUMO Objetivos: Avaliar o ângulo palmar cortical (APC) da extremidade distal do rádio, sua variação nas colunas lateral e intermédia, o formato e o padrão da watershed line (WL) e sua correlação com as placas volares bloqueadas disponíveis no mercado. Métodos: Foram analisados 27 ossos rádios do Departamento de Morfologia e nove placas de seis fabricantes diferentes. Medimos os APCs das colunas lateral e intermédia dos rádios e seus correspondentes nas placas, além de compararmos o relevo do terço distal do rádio e das placas. Quanto a WL, comparamos o formato nas peças e seu equivalente nas placas, sendo classificados em quatro tipos: biconvexo, convexo, convexo ulnar e plano. Resultados: O APC variou entre as colunas do rádio, sendo a média da coluna lateral 153,40° e, da intermédia 146,06°. Quatro das nove placas não apresentaram variação na angulação volar. Dos 27 rádios, 13 apresentaram padrão convexo e 12 biconvexo, enquanto a maioria das placas (sete das nove analisadas) tinham desenho biconvexo. Conclusão: A anatomia dos rádios foi variável entre as peças, sendo a coluna intermédia mais inclinada que a coluna lateral. A placa Synthes ® -2 foi a que apresentou relevo mais próximo dos achados anatômicos da extremidade distal do rádio, seguida pela Newclip ® -2. Nível de Evidência II, Estudo Anatômico Descritivo.

18.
Article Dans Chinois | WPRIM | ID: wpr-928292

Résumé

OBJECTIVE@#To compare the clinical efficacy of locking plate fixation with a fibular strut allograft (FA group) and locking plate fixation alone (LP group) in the treatment of proximal humeral fractures in adults by Meta-analysis.@*METHODS@#Databases including PubMed, The Cochrane Library, Embase, Chinese BioMedical Literature Database(CBM), China National Knowledge Infrastructure(CNKI), WanFang Data, and China Science and Technology Journal Database (cpvip Database) were searched by computer from establishing to March 2020 to collect studies about locking plate fixation with fibular strut allograft versus locking plate fixation alone for proximal humeral fractures in adults. Two reviewers independently screened literature, extracted data, and assessed the risk of bias of included studies. The postoperative humeral head height changes, neck-shaft angle changes, Constant-Murley score, American Shoulder and Elbow Surgeons(ASES)score, visual analogue scale(VAS), varus malunion rate, and screw penetration rate were compared by RevMan 5.3 software for Meta-analysis.@*RESULTS@#Ten cohort studies were enrolled in a total of 749 patients, 300 patients in the FA group and 449 patients in the LP group. The results of Meta-analysis showed that locking plate with fibular strut allograft was superior to locking plate fixation alone in the changes in humeral head height [MD=-2.69, 95%CI(-3.24, -2.13), P<0.000 01], the changes in neck-shaft angle [MD=-5.65, 95%CI(-7.18, -4.12), P<0.000 01], Constant-Murley score [MD=9.00, 95%CI(4.26, 13.73), P=0.000 2], the ASES score [MD=5.56, 95%CI(4.29, 6.84), P=0.000 01], VAS score [MD=-0.23, 95%CI(-0.37, -0.09), P=0.001], the varus malunion rate [RR=0.22, 95%CI(0.09, 0.53), P=0.000 7] and the screw penetration rate [RR=0.26, 95%CI(0.13, 0.55), P=0.000 3], respectively.While there was no significant difference in the rate of osteonecrosis of the humeral head [RR=1.18, 95%CI(0.57, 2.45), P=0.65].@*CONCLUSION@#For proximal humeral fractures in adults, current evidence shows that locking plate fixation with fibular strut allograft is superior to single locking plate fixation in improving postoperative radiological outcomes and shoulder function, relieving postoperative pain, reducing varus malunion rate and screw penetration rate. However, the efficacy in decreasing the osteonecrosis rate is not clear. Due to limited quality and quantity of the included studies, more high-quality studies are required to verify the above conclusion.


Sujets)
Adulte , Humains , Allogreffes , Plaques orthopédiques , Ostéosynthèse interne/méthodes , Fractures de l'humérus , Études rétrospectives , Fractures de l'épaule/chirurgie , Résultat thérapeutique
19.
Journal of Chinese Physician ; (12): 1546-1551, 2022.
Article Dans Chinois | WPRIM | ID: wpr-956338

Résumé

Objective:To establish a composite functional evaluation system to study the clinical efficacy of single plate and double plate internal fixation in the treatment of C3 distal radius fractures in the elderly.Methods:62 elderly patients (≥ 60 years old) with type C3 distal radius fractures who were admitted to the First Affiliated Hospital of Anhui University of Science and Technology from September 2018 to August 2021 were retrospectively selected and divided into two groups according to the surgical methods: bilateral plate internal fixation treatment group (double plate group) and unilateral plate internal fixation treatment group (single plate group); The preoperative anatomical angle, wrist mobility (flexion and extension) and radius shortening of the two groups were recorded. The anatomical angle, wrist mobility (flexion and extension), clinical Gartland-Werley, DASH Score for Upper Limb Function (DASH) , Wrist Joint Cooney Score and clinical healing time at the 3rd, 6th, 9th and 12th months after operation were followed up. A composite evaluation table was established to comprehensively evaluate the postoperative recovery of patients in the two group.Results:There was no significant difference in anatomical indexes of radius between the two groups before operation (all P>0.05). All anatomical angles and wrist range of motion were within the normal range after operation, and there was no statistical difference between the two groups in each anatomical index of radius within 3 and 6 months after operation (all P>0.05). However, the palmar inclination, ulnar deviation, wrist flexion and dorsiflexion mobility of the double plate group were relatively stable at 9 and 12 months after operation, which were better than those of the single plate group (all P<0.05). The palmar inclination and ulnar deviation of the single plate group increased with time. After operation, the radius shortening of the two groups recovered significantly, and the radius length of the double plate group was maintained better than those of the single plate group for 9 and 12 months (all P<0.05). There was no significant difference in the scores of the two groups within 3 and 6 months after operation (all P>0.05), but the Gartland Werley score, DASH score and Cooney wrist score of the double plate group were significantly better than those of the single plate group at 9 and 12 months after operation (all P<0.05). The clinical healing time of single plate treatment was (14.51±0.88)weeks, the longest was 108 days, while that of double plate treatment was (12.03±1.77)weeks, the longest was 129 days, with statistically significant difference ( P<0.05). There was no significant difference in the incidence of complications between the two groups ( P>0.05). There was no statistically significant difference between the two groups in the final composite evaluation results ( P>0.05), but the total score of the double plate group was smaller than that of the single plate group, with a difference of 39.67 points, indicating that the double plate group still had certain advantages in various scores. Conclusions:According to the composite evaluation system, both single plate and double plate treatment of C3 distal radius fractures in the elderly can achieve satisfactory results. Double plate fixation of distal radius fractures still has a certain significance in maintaining joint stability and improving joint mobility.

20.
Article Dans Chinois | WPRIM | ID: wpr-956546

Résumé

Objective:To explore the clinical efficacy of internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device for tibial plateau fractures of Schatzker type Ⅵ.Methods:A retrospective study was conducted of the 32 patients with tibial plateau fracture of Schatzker type Ⅵ who had been treated at Orthopaedic Department, Mindong Hospital Affiliated to Fujian Medical University from April 2018 to July 2021. Depending on their treatments, they were divided into 2 groups. In the control group of 16 cases subjected to open reduction and internal fixation with manual traction, there were 9 males and 7 females with an age of 50.0±11.7 years; in the observation group of 16 cases subjected to internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device, there were 8 males and 8 females with an age of 54.6±11.1 years. The operation time, fracture reduction time, total incision length, intraoperative blood loss, Rasmussen knee function score and maximum active range of knee motion were compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability between the groups ( P>0.05). The operation time [(158.6±26.0) min], fracture reduction time [(61.6±9.6) min], and total incision length [16.0 (13.3, 17.0) cm] in the observation group were significantly shorter than those in the control group [(199.9±60.9) min, (73.8±17.2) min, and 20.0 (17.0, 21.8) cm]; the intraoperative blood loss [175.0 (100.0, 200.0) mL] in the observation group was significantly less than that in the control group [200.0 (162.5, 387.5) mL]; the maximum active ranges of knee motion at one week and one month in the observation group were 94.9°±12.0° and 113.8°±14.1°, significantly larger than those in the control group (78.3°±14.6° and 96.8°±11.4°) (all P<0.05). Fractures achieved bony union at one year after operation in both groups. At 12 months after operation, there was no significant difference in the maximum active range of knee motion or the Rasmussen knee function score between the 2 groups ( P>0.05). Conclusion:In the treatment of Schatzker type Ⅵ tibial plateau fractures, compared with manual traction and open reduction, internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device can shorten operation time and total incision length, reduce intraoperative blood loss, and facilitate postoperative functional recovery of the knee for the patients.

SÉLECTION CITATIONS
Détails de la recherche