RÉSUMÉ
Abstract This comprehensive review compares clinical protocols of important entities regarding the management of fetal growth restriction (FGR), published since 2015. Five protocols were chosen for data extraction. There were no relevant differences regarding the diagnosis and classification of FGR between the protocols. In general, all protocols suggest that the assessment of fetal vitality must be performed in a multimodally, associating biophysical parameters (such as cardiotocography and fetal biophysical profile) with the Doppler velocimetry parameters of the umbilical artery, middle cerebral artery, and ductus venosus. All protocols reinforce that the more severe the fetal condition, the more frequent this assessment should be made. The timely gestational age and mode of delivery to terminate the pregnancy in these cases can vary much between the protocols. Therefore, this paper presents, in a didactic way, the particularities of different protocols for monitoring FGR, in order to help obstetricians to better manage the cases.
Resumo Esta revisão compreensiva compara protocolos clínicos de entidades importantes em relação ao manejo da restrição de crescimento fetal (RCF), publicados desde 2015. Cinco protocolos foram escolhidos para a extração de dados. Não houve diferenças relevantes quanto ao diagnóstico e classificação da RCF entre os protocolos. Em geral, todos os protocolos sugerem que a avaliação da vitalidade fetal deve ser realizada de forma multimodal, associando parâmetros biofísicos (como cardiotocografia e perfil biofísico fetal) aos parâmetros dopplervelocimétricos da artéria umbilical, artéria cerebral média e ducto venoso. Todos os protocolos reforçam que quanto mais grave a condição fetal, mais frequente essa avaliação deve ser feita. A idade gestacional oportuna e o modo de parto para interromper a gravidez nesses casos podem variar muito entre os protocolos. Portanto, este trabalho apresenta, de forma didática, as particularidades de diferentes protocolos de acompanhamento de RCF, a fim de auxiliar os obstetras no melhor manejo dos casos.
Sujet(s)
Humains , Nouveau-né , Prématuré , Cardiotocographie , Fluxmétrie laser Doppler , Recommandations comme sujet , Retard de croissance intra-utérinRÉSUMÉ
Abstract Objectives: although mortality and perinatal asphyxia in newborns have been considerably reduced, there are still deficiencies in screening and diagnosis methods for intrapartum fetal well being that aim to detect its early alterations. Therefore, the purpose of this research was to apply a methodology based on probability and entropy and confirm its capacity to detect normal and abnormal fetal cardiac dynamics from 20-minute cardiotocographic tracings. Methods: 80 cardiotocographic tracings of pregnant women in the last trimester were collected, of which the minimum and maximum fetal heart rate were evaluated every 10 seconds, as well as its repetitions along with their probability and the diagnostic S/k ratio. Finally, the statistical analysis was carried out to establish the diagnostic capacity of the method concerning the clinical evaluation and interpretation of the cardiotocographic tracing, taken as the Gold Standard. Results: it was confirmed that S/k ratio values differentiated normal from abnormal fetal cardiac dynamics with sensitivity and specificity values of 100% and a Kappa coefficient of 1. Conclusion: the applicability of a diagnostic mathematical method of cardiotocography was confirmed, which suggests its implementation in the clinical context to detect alterations in fetal well-being in 20 minutes.
Resumo Objetivos: aunque se ha logrado reducir considerablemente la mortalidad y asfixia perinatal en neonatos, aún hay deficiencias en los métodos de tamizaje y diagnóstico del bienestar fetal intraparto que detecten sus alteraciones tempranas. Por lo anterior, el propósito de esta investigación fue aplicar una metodología basada en la probabilidad y la entropía y confirmar su capacidad para diagnosticar la dinámica cardíaca fetal normal de la anormal a partir de trazados cardiotocográficos de 20 minutos. Métodos: se recolectaron 80 trazados cardiotocográficos de gestantes en el último trimestre, de los cuales se evaluaron frecuencia cardíaca fetal mínima y máxima cada 10 segundos al igual que sus repeticiones, su probabilidad y la proporción S/k diagnóstica. Finalmente, se realizó un análisis estadístico para establecer la capacidad diagnóstica del método con respecto a la interpretación el trazado cardiotocográfico y la evaluación clínica, tomadas como Gold Standard. Resultados: se confirmó que los valores de la proporción S/k diferenciaron las dinámicas cardíacas fetales normales de las anormales con valores de sensibilidad y especificidad del 100% y un coeficiente Kappa de 1. Conclusión: se confirmó la aplicabilidad de un método matemático diagnóstico de la cardiotocografía, lo cual sugiere que su implementación en la clínica para detectar alteraciones del bienestar fetal en 20 minutos.
Sujet(s)
Humains , Femelle , Grossesse , Troisième trimestre de grossesse , Rythme cardiaque foetal , Cardiotocographie/méthodes , Dépistage néonatal , Soins périnatals , EntropieRÉSUMÉ
Abstract Objective To determine the effect of treadmill walking on maternal heart rate (MHR) and cardiotocographic parameters (basal fetal heart rate [FHR], active fetal movements [AFM], number of accelerations and decelerations, and short-term variation [STV] and long-term variation [LTV] of fetal heart rate) in pregnant women at 36 weeks. Methods A nonrandomized, open clinical trial involving 88 healthy pregnant women submitted to moderate intensity walking and computed cardiotocography in 3 20- minute periods (resting, treadmill walking, and postexercise recovery). Results The mean FHR decreased during walking (resting: 137 bpm; treadmill: 98 bpm; recovery: 140 bpm; p<0.001), with bradycardia occurring in 56% of the fetuses in the first 10minutes of exercise, and in 47% after 20minutes. Bradycardia was not detected in the other phases. The mean STV and HV were 7.9, 17.0, and 8.0 milliseconds (p<0.001) and 7.6, 10.8 and 7.6 bpm (p=0.002) in the resting, walking and recovery phases, respectively. Themean number of fetalmovements in 1 hour was 29.9, 22.2 and 45.5, respectively, in the 3 periods (p<0.001). In overweight/obese women, the mean FHR was lower (p=0.02). Following the logistic regression analysis, two variables remained significantly associated with bradycardia: maternal fitness in the 28th week of pregnancy (protective effect) and maternal weight (increased risk). Conclusion In healthy fetuses, physical exercise proved to be safe, since, although FHR and AFM decreased during treadmill walking, an increase in SVT and LTV was observed.
Resumo Objetivo Determinar o efeito da caminhada em esteira sobre a frequência cardíaca materna (FCM) e parâmetros cardiotocográficos (batimentos cardiofetais basais [BCFs], movimentos ativos fetais [MAFs], número de acelerações e desacelerações e variabilidade de curta [STV] e longa [LTV] duração da frequência cardíaca fetal) em gestantes na 36a semana. Métodos Foi realizado umensaio clínico não randomizado e aberto com 88 gestantes saudáveis submetidas a caminhada de moderada intensidade na esteira e a cardiotocografia computadoriza em 3 momentos de 20 minutos (antes, durante e após a caminhada). Resultados A média dos BCFs diminuiu durante a caminhada, retornando a níveis prévios (antes: 137 bpm; durante: 98 bpm; após: 140 bpm; p<0,001), com bradicardia ocorrendo em 56% dos fetos nos primeiros 10 minutos do exercício, e em 47% após 20 minutos. A bradicardia fetal não foi observada em outrosmomentos (antes ou depois). As médias da STV e da LTV foram 7,9, 17,0 e 8,0milissegundos (p<0,001) e 7,6, 10,7 e 7,6 bpm (p=0,002) antes, durante e após a caminhada, respectivamente. Amédia dos números dos MAFs em 1 hora foi 29,9, 22,2 e 45,5, respectivamente, nos três momentos (p<0,001). Nas mulheres com sobrepeso/obesidade, a média da FCM foi menor (p=0,02). Após a análise de regressão logística, duas variáveis permaneceram significativamente associadas a bradicardia: aptidão maternal na 28a semana de gravidez (efeito protetor) e peso materno (aumento do risco). Conclusão Em fetos saudáveis, o exercício físico mostrou-se seguro, uma vez que, embora os BCFs e osMAFs diminuam durante a caminhada na esteira, foi observado um aumento da SVT e da LTV.
Sujet(s)
Humains , Femelle , Adolescent , Adulte , Jeune adulte , Sécurité , Rythme cardiaque foetal/physiologie , Grossesse/physiologie , Exercice physique/physiologie , Foetus/physiologie , Troisième trimestre de grossesse/physiologie , Pression sanguine/physiologie , Cardiotocographie , Marche à pied/physiologieRÉSUMÉ
ABSTRACT Objective: We speculate that genetic racial disparity exists in fetal life and can be detected by modern computerized cardiotocography (cCTG) . Methods: This is a retrospective study comparing the results of the cCTG of pregnant patients at 37-42 weeks according to the parental ethnicity (black versus white). A cCTG was performed to analyze the variables of fetal heart rate (FHR). The cCTG variables analyzed were: percentage of signal loss; number of contractions; basal FHR; number of accelerations; number of decelerations; length of high variation episodes; short-term variability (STV); total trace duration time; and number of fetal active movements. Non-stress test (NST) parameters in the two groups were compared using the Mann-Whitney test for continuous data, and the Chi-square test for categorical variables. Results: We found a significantly lower number of active fetal movements (p 1/4 0.007) and longer periods of low variation (p 1/4 0.047) in the cCTG of black patients when compared with white patients. Conclusions: In conclusion, identifying the factors responsible for the variance in the objective analysis of CTG results is important to improve the outcomes of patients. Our study lends further evidence as to the importance of ethnicity in clinical cCTG interpretation.
RESUMO Objetivo: Especulamos que disparidade genética racial exist ana vida do feto, e que possa ser detectada por moderna cardiotocografia computadorizada (cCTG). Métodos: Estudo retrospective comparando resultados do cCTG de gestantes entre 37-42 semanas de gestação de acordo com etnicidade dos pais (negro vs. brancos). cCTG foi usado para analisar as variáveis a frequência cardíaca do feto (FHR). As variáveis abalizadas do cCTG foram o % de perda de sinal, número de contrações, basal FHR, número de acelerações, número de desacelerações, comprimento dos episódios de alta variação, viabilidade de curto prazo, tempo total de duração do rastreamento, e número de movimentos de atividade fetal. Os parâmetros do teste de não estresse (NST) em dois grupos foram comparados usando o teste de Mann-Whitney para dados contínuos e teste qui-square para variáveis categóricas. Resultados: Encontramos números significativamente mais baixos de movimentos de atividade fetal (p 1/4 0,007) e períodos mais longos de baixa variação (p 1/4 0,047) no cCTG de pacientes negros se comparados a pacientes brancos. Conclusões: Identificar fatores responsáveis pela variação na análise objetiva dos resultados de CTG é importante em resultados de pacientes que apresentam melhora. Nosso estudo fornece evidências adicionais à importância de estudos clínicos da etnicidade interpretada pelo cCTG.
Sujet(s)
Humains , Femelle , Grossesse , 38410 , Cardiotocographie/méthodes , Diagnostic assisté par ordinateur , 38413 , Rythme cardiaque foetal/physiologie , Loi du khi-deux , Mouvement foetal , Études rétrospectives , Statistique non paramétriqueRÉSUMÉ
Objective: the aim of this study was to investigate the patterns of transient FHR accelerations (10 bpm and 15 bpm) in the third trimester of pregnancy, comparing the occurrence of this event before and after the 32nd gestational week. Methods: This is a prospective study comparing the results of the computerized cardiotocography of 46 low-risk women with singleton pregnancies, maternal age between 18 and 40 years, gestational age between 28 and 40 weeks, absence of maternal morbidity and adequate fetal growth according to ultrasound. Computed Cardiotocography (8002 Sonicaid System and Fetal Care System) was performed for 30 minutes to analyze the variables of FHR. Results: twenty-three pregnant women underwent cardiotocography before 32 weeks (mean = 29.9 weeks, SD = 1.4 weeks) and were compared with 23 pregnant women who were examined after 32 weeks (mean = 36.3 weeks, SD = 2.5 weeks). Regarding the characteristics of FHR, fetuses evaluated between 32 1/7 weeks and 40 weeks showed a significantly greater number of accelerations above 15 bpm (median = 5, variation 0-18) than the group of pregnant women from 28 to 32 weeks (median = 4, variation 0 to 10; P = 0.048). There was a significant positive correlation between the number of accelerations above 15 bpm and the gestational age at examination (rho = 0.33; P = 0.026). Conclusion: computerized cardiotocography showed an association regarding the number of transient accelerations greater than 15 bpm in the assessment of both periods before and after 32 weeks of gestational age, suggesting the influence of the maturation of the fetal autonomic nervous system with pregnancy progression. .
Objetivo: o objetivo deste estudo foi investigar os padrões das acelerações transitórias da FCF (de 10 e 15 bpm) no terceiro trimestre da gestação, comparando a ocorrência desse evento antes e após a 32ª semana gestacional. Métodos: trata-se de estudo prospectivo comparando os resultados do exame de cardiotocografia computadorizada de 46 gestantes de baixo risco, com feto único, idade materna entre 18 e 40 anos, idade gestacional entre 28 e 40 semanas, ausência de morbidades maternas e crescimento fetal adequado pela ultrassonografia. Foi realizada a cardiotocografia computadorizada (Sonicaid System 8002 e Fetal Care System) por 30 minutos para análise das variáveis da FCF. Resultados: vinte e três gestantes que realizaram a cardiotocografia antes da 32ª semana (média = 29,9 semanas, DP = 1,4 semanas) foram comparadas com 23 que realizaram o exame após a 32ª semana (média = 36,3 semanas, DP = 2,5 semanas). Quanto às características da FCF, os fetos avaliados entre 32 1/7 semanas e 40 semanas apresentaram número significativamente maior de acelerações acima de 15 bpm (mediana = 5, variação 0 a 18) que o grupo de gestantes de 28 a 32 semanas (mediana = 4, variação 0 a 10; P = 0,048). Houve correlação significativa e positiva entre o número de acelerações transitórias acima de 15 bpm e a idade gestacional no momento do exame (rho = 0,33; P = 0,026). Conclusão: a cardiotocografia computadorizada revelou associação entre o número de acelerações transitórias acima de 15 bpm quando avaliados os períodos antes e após 32 semanas de idade gestacional, sugerindo influência da maturação do sistema nervoso autônomo fetal com a progressão da gestação. .
Sujet(s)
Adolescent , Adulte , Femelle , Humains , Grossesse , Jeune adulte , Cardiotocographie/instrumentation , Mouvement foetal/physiologie , Rythme cardiaque foetal/physiologie , Âge gestationnel , Troisième trimestre de grossesse , Études prospectivesRÉSUMÉ
El estudio clínico fetal relaciona aspectos críticos como la intensidad de las contracciones uterinas, movimientos del feto y frecuencia cardiaca de manera simultánea para evaluar el bienestar fetal. Los cambios periódicos o transitorios de la frecuencia cardiaca son objeto de estudio y aparecen en relación a diversos estímulos fetales como movimientos espontáneos o provocados, contracciones uterinas, hipo fetal, etc. Con este propósito, en una valoración de los mismos es necesario disponer de una constante monitorización, en la que se exprese la frecuencia y la variabilidad cardiaca fetal de manera eficiente. En este artículo se presenta el desarrollo de un sistema de tococardiografía para el registro de la frecuencia cardiaca fetal y la intensidad de las contracciones uterinas compuesto por tres tarjetas electrónicas, una unidad de procesamiento digital paralela, una campana acústica y una pantalla para adquirir y procesar de manera no invasiva las señales tococardiográficas.
Clinical evaluation on fetuses is related to simultaneous critical aspects such as intensity of uterine contractions, fetal movements, and heart rate. Periodic or transient changes in heart rate are studied and appear in relation to various fetal stimuli as spontaneous or induced movements, uterine contractions, fetal hiccups, and so on. Thus, their evaluation is necessary to obtain constant monitoring in which the frequency and variability are expressed efficiently. This paper presents the development of a cardiotochography system for recording fetal heart rate and intensity of uterine contractions, which is composed by three electronic boards, a digital parallel processing unit, a sounds bell and a screen to acquire non-invasively and process tococardiography’s signals.
O estudo clinico fetal relaciona aspectos críticos, como a intensidade das contrações uterinas, movimentos fetais e batimentos cardíacos simultaneamente para avaliar o bem-estar fetal. As mudanças periódicas ou transitórias da frequência cardíaca são estudados e aparecem em relação a vários movimentos fetais espontâneas ou induzidas, as contrações uterinas, soluços fetais, etc. Para este efeito, em uma revisão do mesmo é necessário ter monitoramento constante, na que se exprese a freqüência e variabilidade do ritmo cardíaco fetal de forma eficiente. Este artigo é apresentado o desenvolvimento de um sistema de tococardiografía para registar o ritmo cardíaco fetal e intensidade das contrações uterinas composto por três placas eletrônicas, uma unidade de processamento digital paralelo, uma cabine acústica e uma tela para adquirir e processar de maneira não invasiva as sinais tococardiográficas.
RÉSUMÉ
El estudio tiene como finalidad establecer la sensibilidad, la especificidad, el valor predictivo positivo, y el valor predictivo negativo de la monitorización cardiotocográfica fetal, para diagnóstico de Sufrimiento Fetal Agudo y que llevan a la terminación de la gestación por cesárea de emergencia, comparado con el test de Apgar del recién nacido tomado como GOLD STANDARD. El universo de estudio consistió en 880 pacientes embarazadas a quienes se les realizó cesárea, se obtuvo una muestra de 110 recién nacidos. De ellos 46 fueron diagnosticados de Sufrimiento Fetal Agudo con la prueba de oro, Apgar al minuto < de 7, y 64 como normales, Apgar al minuto ≥ a 7. En el estudio se encontró que la sensibilidad de la Monitorización cardiotocográfica fetal fue del 21,7% (IC 95% 12.26, 35.57¹). Y la especificidad de la Monitorización cardiotocográfica fetal fue del 84.4% (IC 95% 73.57, 91.29¹). Se concluyó que la Monitorización cardiotocográfica fetal, nos ayuda más como prueba para valorar bienestar fetal, sobre todo en embarazos de alto riesgo obstétrico, pero en sí es poco sensible para detectar que un feto se encuentra con Sufrimiento Fetal Agudo.
This study is attained to establish the sensibility, specificity, positive predictive value, and negative predictive value, of the fetal cardiotocographic monitoring for the diagnosis of acute fetal suffering wich leads to the termination of the gestation with in an emergency cesarean surgery, compared to the APGAR test of the new born as a Gold Standard. The universe of the study consisted in 880 pregnant women to whom a cesarean surgery was made. A 110 new born sample was obtained. 46 of them were diagnosed with acute fetal suffering with Gold Standard test; with an Apgar test < 7 at the first minute, 64 were normal with an Apgar test ≥ 7. This study found that the sensibility of the fetal cardiotocographic monitoring was 21.7% (IC 95% 12.26, 35.57¹).), and the specificity was 84.4% (IC 95% 73.57, 91.29¹). The conclusion was that the fetal cardiotocographic monitoring helps more as a test to value fetal well-being, above everything in high obstetrics risk pregnancies, the test is pretty less sensitive to detect that a fetus is coursing acute fetal suffering.
Sujet(s)
Humains , Femelle , Grossesse , Cardiotocographie , Césarienne , Surveillance de l'activité foetale , Valeur prédictive des tests , Diagnostic , Souffrance foetaleRÉSUMÉ
O nascimento de um feto saudável sempre constituiu um dos principais objetivos da Obstetrícia. Nos dias atuais, vários procedimentos têm sido utilizados com esta finalidade, porém, apesar da evolução dos métodos diagnósticos e da melhor compreensão da fisiopatologia do sofrimento fetal, ainda existem lacunas no conhecimento sobre o comportamento do feto frente à hipóxia. Outro fator complicador na avaliação do sofrimento fetal é o grande número de doenças maternas com diferentes fisiopatologias que podem interferir no bem-estar fetal. Esta revisão tem como objetivo descrever os principais métodos de avaliação biofísica da vitalidade fetal, com base nas melhores evidências científicas correntemente disponíveis na literatura, e incluindo níveis de evidências e graus de recomendação. Será abordada a avaliação da vitalidade fetal nos casos de insuficiência placentária, não sendo estudadas as situações especiais, como diabetes e gestação múltipla. Evidencia-se uma falta de consenso sobre qual procedimento deve ser utilizado na avaliação da vitalidade fetal, na prática clínica diária. As sociedades internacionais recomendam a realização da doplervelocimetria, da cardiotocografia e do perfil biofísico fetal apenas em gestantes de alto risco, com suspeita de insuficiência placentária ou com restrição de crescimento intrauterino
The birth of a healthy baby has always been an important goal of Obstetrics. Nowadays, many procedures have been used for this purpose, but despite great development in diagnostic methods and better understanding of pathophysiology of fetal distress, there are still gaps in knowledge about fetal behavior in situations of hypoxia. Another complicating factor in the assessment of fetal distress is the large number of maternal diseases with different pathophysiology, which can compromise fetal well-being. This review aims at describing the main methods for fetal assessment, based on the best scientific evidence currently available, including levels of evidence and grades of recommendation. Only fetal evaluation in cases of placental insufficiency will be addressed, and special situations such as diabetes and multiple pregnancies will not be studied. Current evidences show a lack of consensus on what is the best procedure to assess fetal well-being in clinical practice. International societies recommend the performance of Doppler velocimetry, cardiotocography, and fetal biophysical profile only in high-risk pregnancies with suspected placental insufficiency or restricted intrauterine growth
Sujet(s)
Humains , Femelle , Grossesse , Cardiotocographie , Développement foetal , Surveillance de l'activité foetale/méthodes , Souffrance foetale/diagnostic , Souffrance foetale/physiopathologie , Échographie-doppler/méthodes , Rythme cardiaque foetal/physiologie , Hypoxie foetale/prévention et contrôle , Insuffisance placentaire/diagnostic , Grossesse à haut risque , Phénomènes biophysiques/physiologieRÉSUMÉ
OBJETIVO: comparar os padrões da frequência cardíaca fetal (FCF) do segundo e terceiro trimestres da gestação. MÉTODOS: estudo prospectivo, comparativo, realizado no período de Janeiro de 2008 e Julho de 2009 com os seguintes critérios de inclusão: gestação única, feto vivo, ausência de intercorrências clínicas ou obstétricas, ausência de malformação fetal, com idade gestacional entre 24 e 27 semanas (segundo trimestre - 2ºT) ou entre 36 e 40 semanas (terceiro trimestre - 3ºT). Foram realizados os exames de cardiotocografia computadorizada (Sistema 8002 - Sonicaid) por período de 30 minutos e o perfil biofísico fetal. O Sistema 8002 analisa o traçado da FCF em períodos de 3,75 segundos (1/16 de minuto). Em cada período, a duração média dos intervalos de tempo entre sucessivos batimentos cardíacos fetais foi avaliada e mensurada em milisegundos (ms). A FCF média foi calculada em cada período, e também as diferenças entre períodos adjacentes. Os parâmetros incluíram: FCF basal, acelerações transitórias, duração dos episódios de alta variação, duração dos episódios de baixa variação e variação de curto prazo. Os resultados foram analisados pelos testes t de Student, teste do qui-quadrado e teste exato de Fischer. Foi adotado nível de significância de 0,05. RESULTADOS: dezoito gestações de 2ºT foram comparadas com 25 gestações de 3ºT. Houve diferença significativa nos parâmetros da FCF avaliada pela cardiotocografia computadorizada quando comparados os fetos de 2ºT e os de 3ºT em relação aos seguintes resultados: média da FCF basal (143,8 bpm versus 134,0 bpm, p=0,009), média do número de acelerações transitórias >10 bpm (3,7 versus 8,4, p<0,001) e >15 bpm (0,9 bpm versus 5,4 bpm, p<0,001), duração média dos episódios de alta variação (8,4 min x 15,4 min, p=0,008) e média da variação de curto prazo (8,0 ms versus10,9 ms, p=0,01). Em todos os exames o perfil biofísico fetal apresentou resultado normal. CONCLUSÕES: o presente estudo constata diferenças significativas nos padrões avaliados entre gestações de segundo e terceiro trimestres, e indica a influência da maturação do sistema nervoso autonômico na regulação da FCF.
PURPOSE: to compare the patterns of fetal heart rate (FHR) in the second and third trimesters of pregnancy. METHODS: a prospective and comparative study performed between January 2008 and July 2009. The inclusion criteria were: singleton pregnancy, live fetus, pregnant women without clinical or obstetrical complications, no fetal malformation, gestational age between 24 and 27 weeks (2nd trimester - 2T) or between 36 and 40 weeks (3rd trimester - 3T). Computerized cardiotocography (System 8002 - Sonicaid) was performed for 30 minutes and the fetal biophysical profile was obtained. System 8002 analyzes the FHR tracings for periods of 3.75 seconds (1/16 minutes). During each period, the mean duration of the time intervals between successive fetal heart beats is determined in milliseconds (ms); the mean FHR and also the differences between adjacent periods are calculated for each period. The parameters included: basal FHR, FHR accelerations, duration of high variation episodes, duration of low variation episodes and short-term variation. The dataset was analyzed by the Student t test, chi-square test and Fisher's exact test. Statistical significance was set at p<0.05. RESULTS: eighteen pregnancies on the second trimester were compared to 25 pregnancies on the third trimester. There was a significant difference in the FHR parameters evaluated by computerized cardiotocography between the 2T and 3T groups, regarding the following results: mean basal FHR (mean, 143.8 bpm versus 134.0 bpm, p=0.009), mean number of transitory FHR accelerations > 10 bpm (3.7 bpm versus 8.4 bpm, p <0.001) and >15 bpm (mean, 0.9 bpm versus 5.4 bpm, p <0.001), mean duration of high variation episodes (8.4 min versus 15.4 min, p=0.008) and mean short - term variation (8.0 ms versus 10.9 ms, p=0.01). The fetal biophysical profile showed normal results in all pregnancies. CONCLUSION: the present study shows significant differences in the FHR characteristics when the 2nd and 3rd trimesters of pregnancy are compared and confirms the influence of autonomic nervous system maturation on FHR regulation.
Sujet(s)
Adulte , Femelle , Humains , Grossesse , Rythme cardiaque foetal , Âge gestationnel , Deuxième trimestre de grossesse , Troisième trimestre de grossesse , Études prospectivesRÉSUMÉ
OBJETIVOS: avaliar a influência dos níveis de hemoglobina (Hb) materna nos padrões da frequência cardíaca fetal (FCF) e no perfil biofísico fetal (PBF) em gestações a termo. MÉTODOS: gestantes portadoras de anemia (Hb<11,0 g/dL) foram avaliadas prospectivamente, entre a 36ª e a 40ª semana de gestação, no período compreendido entre janeiro de 2008 e março de 2009. O Grupo Controle foi constituído por gestantes de termo, saudáveis, com valores normais de hemoglobina (Hb>11,0 g/dL). Foram excluídos casos com anomalias ou restrição do crescimento fetal. A avaliação da FCF foi realizada pela cardiotocografia computadorizada (Sistema8002-Sonicaid) e análise do traçado com 30 minutos de exame. O PBF foi realizado em todas as pacientes. Foram utilizados os testes t de Student, teste do χ2 e teste exato de Fisher. O nível de significância utilizado foi de 0,05. RESULTADOS: A média da Hb materna no grupo com anemia (n=18) foi de 9,4 g/dL (DP=1,4 g/dL) e no Grupo Controle 12,4 g/dL (DP=1,3 g/dL). Quanto aos parâmetros da cardiotocografia, não foi constatada diferença significativa nas médias entre os grupos com anemia e controle, respectivamente: FCF basal (131,3 bpm versus 133,7 bpm, p=0,5), acelerações da FCF > 10 bpm (7,9 versus. 8,2, p=0,866), acelerações da FCF > 15 bpm (5,2 versus 5,4, p=0,9), episódios de alta variação da FCF (17,1 versus 15,5 min, p=0,5), episódios de baixa variação da FCF (4,4 versus 3,6 min, p=0,6), e variação de curto prazo (10,5 versus 10,9 ms, p=0,5). Em ambos os grupos, todas as pacientes apresentaram PBF normal. CONCLUSÕES: este estudo sugere que a anemia materna leve ou moderada, sem outras comorbidades maternas ou fetais, não se associa a anormalidades nos parâmetros do perfil biofísico fetal e da FCF analisada pela cardiotocografia computadorizada.
PURPOSES: to evaluate the influence of maternal hemoglobin (Hb) levels in the patterns of fetal heart rate (FHR) and in the fetal biophysical profile (FBP) in term gestations. METHODS: pregnant women with anemia (Hb<11.0 g/dL) were prospectively evaluated between the 36th and the 40th week of gestation, from January 2008 to March 2009. The Control Group was composed of term and healthy pregnant women, with normal values of hemoglobin (Hb>11,0 g/dL). Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid), and by record analysis during 30 minutes of exam. The FBP was done in all the patients. Student's, χ2 and Fisher's exact tests were used, with 0.05 significance level. RESULTS: The average of maternal Hb in the group with anemia (n=18) was 9.4 g/dL (DP=1.4 g/dL), and in the control group, 12.4g/dL (DP=1.3 g/dL). There has been no significant mean differences between groups concerning the cardiotocography parameters, respectively: basal FHR(131.3 versus 133.7 bpm, p=0.5), FHR accelerations > 10b pm (7.9 versus 8.2, p=0.866), FHR accelerations > 15 bpm (5.2 versus. 5.4, p=0.9), episodes of high variation of the FHR (17.1 versus 15.5 min, p=0,5), episodes of variation of the FHR (4.4 versus 3.6 min, p=06), and short term variation (10.5 versus 10.9 ms, p=0.5). In both groups, all patients presented normal FBP. CONCLUSIONS: this study suggests that light or moderate maternal anemia, without other maternal or fetal comorbidity, is not associated with abnormalities in the parameters of fetal biophysical profile and of the FHR analyzed by computerized cardiotocography.
Sujet(s)
Adulte , Femelle , Humains , Grossesse , Jeune adulte , Anémie , Cardiotocographie , Foetus/physiologie , Complications hématologiques de la grossesse , Phénomènes biophysiques , Cardiotocographie/méthodes , Jeune adulteRÉSUMÉ
OBJETIVO: estudar o efeito da estimulação sônica na resposta cardíaca fetal de acordo com os parâmetros fornecidos pela cardiotocografia computadorizada em gestações de baixo risco. MÉTODOS: foram incluídas 20 gestantes de baixo risco com os seguintes critérios de inclusão: idade materna superior a 18 anos; gestação única, feto vivo; idade gestacional entre 36 e 40 semanas; índice de líquido amniótico superior a 8,0 cm e ausência de malformações fetais. Foram excluídos os casos com diagnóstico pós-natal de anomalia fetal. A cardiotocografia computadorizada foi realizada por 20 minutos antes e depois da estimulação sônica fetal. Os resultados foram analisados pelo teste t para amostras dependentes, adotando-se o nível de significância de p<0,05. RESULTADOS: a estimulação sônica foi efetuada com sucesso em todos os casos analisados. Pela análise dos parâmetros cardiotocográficos, não foi constatada diferença significativa quando se comparou os parâmetros pré e pós-estimulação, respectivamente: número médio de movimentos fetais por hora (55,6 versus 71,9, p=0,1); frequência cardíaca fetal (FCF) basal média (135,2 versus 137,5 bpm, p=0,3); média de acelerações da FCF>10 bpm (6,5 versus 6,8, p=0,7); média de acelerações da FCF>15 bpm (3,8 versus 4,3, p=0,5); média da duração dos episódios de alta variação da FCF (11,4 versus 10,9 minutos, p=0,7); média da duração dos episódios de baixa variação da FCF (2,5 versus 1,1 minutos, p=0,2) e média da variação de curto prazo (10,6 versus 10,9 ms, p=0,6). CONCLUSÕES: em gestação de baixo risco, no termo, a cardiotocografia computadorizada não evidenciou diferenças nos parâmetros da FCF após a estimulação sônica fetal.
PURPOSE: to study the effect of acoustic stimulation in the fetal cardiac response, according to parameters from computerized cardiotocography in low risk pregnancies. METHODS: twenty low risk pregnant women were included in the study, according to the following criteria: age over 18; single gestation, living fetus; gestational age between 36 and 40 weeks; amniotic liquid index over 8.0 cm and absence of fetal malformation. Cases with post-natal diagnosis of fetal anomaly were excluded. Computerized cardiotocography was performed for 20 minutes, before and after fetal acoustic stimulation. Results were analyzed by the t test for dependent samples, with significance level at p<0.05. RESULTS: acoustic stimulation was successfully performed in all cases analyzed. By the analysis of the cardiotocographic parameters, there was no significant difference when the pre and post-stimulation parameters were compared: average number of fetal movements per hour (55.6 versus 71.9, p=0.1); mean basal fetal heart rate (FHR) (135.2 versus 137.5 bpm, p=0.3); mean FHR increases>10 bpm (6.5 versus 6.8, p=0.7); mean FHR increases>15 bpm (3.8 versus 4.3, p=0.5); mean duration of high FHR variation episodes (11.4 versus 10.9 min, p=0.7); mean duration of low FHR variation episodes (2.5 versus 1.1 min, p=0.2), and mean short-term variation (10.6 versus 10.9 ms, p=0.6). CONCLUSIONS: in low risk gestations at term, computerized cardiotocography has not evidenced differences in the FHR parameters after the fetal sonic stimulation.
Sujet(s)
Adulte , Femelle , Humains , Grossesse , Stimulation acoustique , Cardiotocographie , Diagnostic assisté par ordinateur , Études transversales , Études prospectivesRÉSUMÉ
FUNDAMENTO: Os efeitos da anestesia local em odontologia com lidocaína e epinefrina, sobre parâmetros cardiovasculares de gestantes portadoras de valvopatias e seus conceptos, não estão esclarecidos. OBJETIVO: Avaliar e analisar parâmetros da cardiotocografia, de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática, quando submetida à anestesia local com 1,8 ml de lidocaína 2 por cento sem vasoconstritor e com epinefrina 1:100.000, durante procedimento odontológico restaurador. MÉTODOS: Realizamos monitorização ambulatorial da pressão arterial, eletrocardiografia ambulatorial materna e cardiotocografia de 31 portadoras de cardiopatia reumática, entre a 28ª e 37ª semana de gestação, divididas em dois grupos conforme presença ou não do vasoconstritor RESULTADOS: Demonstrou-se redução significativa dos valores de frequência cardíaca materna nos dois grupos, durante o procedimento, quando comparado aos demais períodos (p < 0,001). Houve ocorrência de arritmia cardíaca em 9 (29,0 por cento) pacientes, das quais 7 (41,8 por cento) pertencentes ao grupo de 17 gestantes que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos períodos ou grupos (p > 0,05). O mesmo ocorreu (p > 0,05) com número de contrações uterinas, nível e variabilidade da linha de base e número de acelerações da frequência cardíaca fetal. CONCLUSÃO: O uso de 1,8 ml de lidocaína 2 por cento associado à adrenalina mostrou-se seguro e eficaz em procedimento odontológico restaurador durante a gestação de mulheres com cardiopatia valvar reumática.
BACKGROUND: The effects of local dental anesthesia with lidocaine and epinephrine on cardiovascular parameters of pregnant women with heart valve diseases and their fetuses are not fully understood. OBJECTIVES: To assess and analyze cardiotocographic, blood pressure and electrocardiographic parameters of pregnant women with rheumatic heart valve disease undergoing local anesthesia with 1.8mL of lidocaine 2 percent with or without epinephrine 1:100,000 during restorative dental treatment. METHODS: Maternal ambulatory blood pressure and electrocardiographic monitoring as well as cardiotocography of 31 patients with rheumatic heart disease were performed between the 28th and 37th week of gestation. The patients were divided into two groups, those with or without vasoconstrictor. RESULTS: A significant reduction in maternal heart rate was shown in both groups during the procedure in comparison with the other periods (p<0.001). Cardiac arrhythmia was observed in nine (29.0 percent) patients, of which seven (41.8 percent) were from the group of 17 pregnant women who received anesthesia plus epinephrine. No difference in maternal blood pressure was observed when periods or groups were compared (p>0.05). The same occurred (p>0.05) with the number of uterine contractions, baseline level and variability, and number of accelerations of fetal heart rate. CONCLUSION: The use of 1.8mL of lidocaine 2 percent in combination with epinephrine was safe and efficient in restorative dental procedures during pregnancy in women with rheumatic heart valve disease.
FUNDAMENTO: Los efectos de la anestesia local en odontología con lidocaína y epinefrina, sobre los parámetros cardiovasculares de gestantes portadoras de valvulopatías y sus conceptos, no son claros. OBJETIVO: Evaluar y analizar parámetros de la cardiotocografía, de la presión arterial y electrocardiográficos de la gestante portadora de enfermedad valvular reumática, al someterse a anestesia local con 1,8 ml de lidocaína 2 por ciento sin vasoconstrictor y con epinefrina 1:100.000, durante procedimiento odontológico restaurador. MÉTODOS: Realizamos monitoreo ambulatorio de la presión arterial, electrocardiografía ambulatoria materna y cardiotocografía de 31 portadoras de cardiopatía reumática, entre la 28ª y la 37ª semana de gestación, divididas en dos grupos según la presencia o no del vasoconstrictor. RESULTADOS: Se observó reducción significativa de los valores de frecuencia cardíaca materna en los dos grupos, durante el procedimiento, al compararlo con los demás períodos (p < 0,001). Se registró ocurrencia de arritmia cardíaca en 9 (29,0 por ciento) pacientes, de las cuales 7 (41,8 por ciento) pertenecían al grupo de 17 gestantes que recibió anestesia con adrenalina. La presión arterial materna no presentó diferencia al comparar períodos o grupos (p > 0,05). Lo mismo ocurrió (p > 0,05) con el número de contracciones uterinas, nivel de variabilidad de la línea de base y número de aceleraciones de la frecuencia cardíaca fetal. CONCLUSIÓN: El uso de 1,8 ml de lidocaína 2 por ciento asociado a la adrenalina se mostró seguro y eficaz en procedimiento odontológico restaurador durante la gestación de mujeres con cardiopatía valvular reumática.
Sujet(s)
Adolescent , Adulte , Femelle , Humains , Grossesse , Jeune adulte , Anesthésie dentaire/effets indésirables , Anesthésiques locaux/effets indésirables , Épinéphrine/effets indésirables , Lidocaïne/effets indésirables , Complications de la grossesse/physiopathologie , Rhumatisme cardiaque/physiopathologie , Analyse de variance , Anesthésiques combinés/administration et posologie , Anesthésiques combinés/effets indésirables , Anesthésiques locaux/administration et posologie , Troubles du rythme cardiaque/induit chimiquement , Pression sanguine/effets des médicaments et des substances chimiques , Cardiotocographie , Épinéphrine/administration et posologie , Âge gestationnel , Rythme cardiaque foetal/effets des médicaments et des substances chimiques , Lidocaïne/administration et posologie , Surveillance électronique ambulatoire/méthodes , Statistique non paramétrique , Vasoconstricteurs/administration et posologie , Vasoconstricteurs/effets indésirables , Jeune adulteRÉSUMÉ
Se realiza un estudio prospectivo, longitudinal, en el Hospital Materno Infantil "Germán Urquidi", en el período comprendido entre el 1 de enero al 31 de diciembre de 2007, para determinar la utilidad de la cardiotocografía en el diagnóstico de distocia funicular, realizándose 178 estudios cardiotocográficos en gestantes que cumplían los criterios de inclusión del presente trabajo, con el fin de identificar la existencia de signos cardiotocográficos sugestivos de compresión funicular y luego del parto comprobar su existencia. Evidenciando que el estudio cardiotocográfico tiene un valor predictivo negativo y la sensibilidad de 95, 74 y 91,3% respectivamente, demostrando con el estudio que la cardiotocografía intraparto posee una mayor capacidad de identificar fetos comprometidos y en menor proporción a los sanos; así mismo es confiable para descartar la presencia de distocia funicular en los casos donde no existieron signos sugestivos de compresión funicular en el trazado cardiotocográfico.
A prospective longitudinal study, was done in the Hospital Materno Infantil "German Urquidi", between january 1st and december 31st of 2007, to determine the usefulness of the cardiotocography in the diagnostic of funicular distocia, 178 cardiotocographics studies were done in pregnant women that metthe criteria of inclusion ofthe present work, with the end to identify the existence of cardiotocographics signs suggesting the funicular compression and after the birth prove its existence. Confirming that the cardiotocography study has a negative predictive value and a sensibility of 95, 74 and 91,3 % respectively.The study further proves that the intra parto cardiotocography has a major capacity of correctly identifying foetuses compromised and in minor proportion to the healthy ones; this way is trustable to distinguish the presence of funicular disctocia in the cases where no signs existed suggesting the funicular compression in the cardiotocography trace.
RÉSUMÉ
A análise acurada da frequência cardíaca fetal (FCF) correlacionada com as contrações uterinas permite diagnosticar, e consequentemente antecipar, diversos problemas relativos ao bem estar fetal e à preservação de sua vida. O presente trabalho apresenta os resultados de um sistema híbrido, baseado em regras determinísticas e em um módulo de inferência nebuloso do tipo Mamdani, para análise de sinais coletados através de exames denominados cardiotocografias (CTG). As variáveis analisadas são: o valor basal da FCF, suas variabilidades de curto e de longo prazo, acelerações transitórias e desacelerações, sendo estas classificadas por seu tipo e número de ocorrências. São utilizados dois modelos de classificação. A saída do sistema, em qualquer dos modelos, é um diagnóstico de primeiro nível baseado nestas variáveis de entrada. O sistema inteligente para auxílio ao diagnóstico no monitoramento fetal eletrônico por análise de cardiotocografias (SISCTG) foi desenvolvido na linguagem de scripts do programa MATLAB® v.7. O projeto conta também com uma parceria multi-institucional entre o Brasil e a Alemanha, envolvendo o Departamento de Engenharia de Teleinformática (DETI) da Universidade Federal do Ceará (UFC), a Maternidade-Escola Assis Chateaubriand (MEAC), a Technische Universitãt München e a empresa alemã Trium GmbH, que fornece a base de dados utilizada neste trabalho. Os resultados apresentados pelo SISCTG mostram-se promissores, com um índice de acertos (comparando-se os dois modelos utilizados) variando de 83% a 100%, de acordo com o tipo de diagnóstico. Isto permite projetar o aprimoramento deste sistema com novas variáveis de entrada (como a entropia aproximada da FCF e da sua variabilidade). A validação do sistema contou com especialistas brasileiros e alemães na área obstétrica.
The accurate analysis of the fetal heart rate (FHR) and its correlation with uterine contractions (UC) allow the diagnostic and the anticipation of many problems related to fetal distress and the preservation of its life. This paper presents the results of a hybrid system based on a set of deterministic rules and fuzzy inference system developed to analyze FHR and UC signals collected by cardiotocography (CTG) exams. The studied variables are basal FHR, short and long-term FHR variability, transitory accelerations and decelerations, these lasts classified by their type and number of occurrences. Two classification models are used. For both models, the system output is a first level diagnostic based on those input variables. The system is developed using the MATLAB® v.7 script language. The project is also supported by a multi-institutional agreement between Brazil and Germany, among the DETI (Departamento de Engenharia de Teleinformática of the Universidade Federal do Ceará), the MEAC (Maternidade-Escola Assis Chateaubriand), the TUM (Technische Universitãt München), and the Trium GmbH, a German company who supplied the database used in this project. The results are very promising with a diagnostic accuracy (considering the two models used) varying from 83% to 100%, according to the type of diagnostic. These results allow the projection of refinements of the proposed system, inserting new input variables (such as the approximate entropy of the FHR and its variability). The system validation methodology was based on the knowledge of Brazilian and German obstetricians.
Sujet(s)
Cardiotocographie/instrumentation , Cardiotocographie , Diagnostic prénatal/instrumentation , Rythme cardiaque foetal/physiologie , Systèmes experts/instrumentation , Contraction utérine/physiologie , Logique floue , Surveillance de l'activité foetale/instrumentation , Traitement du signal assisté par ordinateur/instrumentationRÉSUMÉ
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em consequência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como frequência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para frequência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de frequência cardíaca materna...
During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine...