RÉSUMÉ
Objective: to evaluate ability of Nano Ceramic Composite endocrown to withstand occlusal forces when used in the anterior region. Material and Methods: eighty endodontically treated maxillary central incisors teeth were randomly divided into two main groups according to the restoration type. Forty of these teeth were post, core and crown restorations and 40 were endocrown restorations. Then they were divided by halves into two subgroups according to the material used 20 were made with Lava Ultimate and the other 20 with IPS e.max. Each subgroup was then further subdivided into two divisions according to the remaining tooth structure above the CEJ (n = 10): 2 mm and 0.5 mm above the CEJ. After teeth preparation, the restorations were all made by CAD/CAM system (Cerec MCXL). All samples had undergone cyclic fatigue testing, and then loaded to fracture using a universal testing machine. The specimens were measured and statistically analyzed using Mann-Whitney test for comparing the mean changes between the groups. Results: Lava Ultimate showed higher mean fracture load values than IPS e.max specimens. Conclusions: endocrowns were found to be more favorable when used on endodontically treated teeth than the conventional post, core and crown restorations.(AU)
Objetivo: Avaliar a capacidade do compósito nanocerâmico endocrown para suportar forças oclusais quando usado na região anterior. Material e Métodos: Oitenta incisivos centrais superiores tratados endodonticamente foram divididos aleatoriamente em dois grupos principais, de acordo com o tipo de restauração. Quarenta desses dentes receberam restaurações com retentor intrarradicular, núcleo e coroa e 40 receberam restaurações endocrown. Em seguida, foram divididos pela metade em dois subgrupos, de acordo com o material utilizado, sendo 20 confeccionados com Lava Ultimate e os demais 20 com IPS e.max. Cada subgrupo foi posteriormente subdividido em dois, de acordo com a estrutura dentária remanescente acima da JEC (n = 10): 2 mm e 0,5 mm acima do JEC. Após o preparo dos dentes, todas as restaurações foram realizadas pelo sistema CAD/ CAM (Cerec MCXL). Todas as amostras foram submetidas a testes de fadiga cíclica e submetidas ao esforço até a fratura em uma máquina universal de testes. As amostras foram medidas e analisadas estatisticamente pelo teste de MannWhitney para comparação das alterações médias entre os grupos. Resultados: lava Ultimate apresentaram valores médios mais altos de carga até a fratura do que as amostras IPS e.max. Conclusões: as endocrowns mostraram-se mais favoráveis quando utilizadas em dentes tratados endodonticamente do que as restaurações convencionais com retentor intrarradicular, núcleo e coroa.(AU)
Sujet(s)
Force occlusale , Céramiques , Résines composites , Fractures osseusesRÉSUMÉ
Objective: O objetivo deste trabalho foi avaliar a deformação plástica em fios NiTi e CuNiTi submetidos à ciclagem mecânica. Material e Métodos: Utilizaram-se fios ortodônticos de CuNITi de cinco marcas comerciais (n=10): RMO, Orthometric, Ormco, Aditek e Eurodonto; e um grupo controle de fio NiTi: Aditek termoativado. Todos os fios, com calibre 0.016'', foram encaixados em slots de quatro bráquetes convencionais alinhados e fixados a uma placa de acrílico. O teste foi realizado com aplicação de carga de 3 N e frequência de 2 Hz entre os dois bráquetes mais centrais, limitando-se à 10.000 ciclos. Após a ciclagem, observou-se a presença ou ausência de fratura dos fios. Não havendo fratura, os fios foram analisados quanto à deformação plástica com uso de transferidor, medindo-se a angulação do fio deformado. Resultados: Os resultados mostraram que não houve fratura de nenhum dos fios analisados. O teste de Kruskal-Wallis mostrou diferenças entre as angulações dos fios ortodônticos (p=0.0009). Com exceção dos fios da Ormco, os demais apresentaram deformação plástica. A maior mediana do valor de angulação foi observada para o fio Aditek Cuper NiTi. Observou-se que as menores medianas foram observadas para os fios RMO, Eurodonto e Ormco. Os fios Aditek termoativado e Orthometric apresentaram angulação intermediária. Conclusão: Nenhum dos fios analisados apresentou fratura. Houve diferenças quanto à deformação plástica sofrida pelos fios avaliados, independentemente da presença de cobre na sua composição química, sendo que o fio Ormco foi o único que não apresentou qualquer deformação. (AU)
Objetivo: The aim of this study was to evaluate the plastic deformation of NiTi and CuNiTi archwires submitted to mechanical cycling. Material and Methods: Orthodontic archwires made of CuNiTi of five commercial brands (n=10) were used: RMO, Orthometric, Ormco, Aditek and Eurodonto; and a Control Group of NiTi archwire: Aditek thermoactivated. All the archwires, with caliber 0.016", were fitted into the slots of four conventional brackets, aligned and fixed to an acrylic plate. The test was performed by applying a load of 3 N and frequency of 2 Hz between the most central brackets, limited to 10,000 cycles. After cycling, the presence or absence of archwire fracture was observed. When there was no fracture, the archwires were analyzed relative to plastic deformation with the use of a transferer, measuring the angulation of the deformed archwire. Results: The results showed that there was no fracture in any of the wires analyzed. The Kruskal-Wallis test showed differences among the angulations of the orthodontic archwires (p=0.0009). With exception of the Ormco wires, the other types presented plastic deformation. The highest median of the angulation value was observed for the Aditek Copper NiTi archwire. The lowest median values were observed for the RMO, Eurodonto and Ormco archwires. The Aditek thermoactivated and Orthometric archwires presented intermediate angulation. Conclusion: None of the archwires analyzed presented fracture. These archwires presented differences in plastic deformation, irrespective of the presence of copper in their chemical composition. The Ormco archwire was the only type that presented no deformation whatever (AU)
Sujet(s)
Cuivre , Fractures osseuses , Fils orthodontiquesRÉSUMÉ
Muitos sistemas adesivos foram desenvolvidos na última década. O objetivo desse estudo foi avaliara resistência adesiva ao cisalhamaneto (RAC)de bráquetes ortodônticos aderidos com primer convencional (PC) ou primer auto-condicionante (PAC), submetidos à ciclagem térmica (CT) e ciclagem térmico-mecânica (CTM). Incisivos bovinos (n =90)foram randomicamente divididos em 2 grupos (n =45) para a colagem dos bráquetes: XT (Transbond XT, 3M-Unitek, CA, USA); SEP (Transbond Plus SEP,3M-Unitek, CA, USA). Após o procedimento adesivo os grupos forma subdivididos em 3 sub-grupos: SC(sem ciclagem) 1 e 4 (n =15 cada); CTM (ciclagem térmico-mecânica)- 2 e 5 (n = 15 cada); CT (ciclagem térmica)- 3 e 6 (n = 15 cada). Um simulador de fadiga térmica foi usado para os subgrupos 3 e 6, que fioram submetidos a 500 ciclos térmicos entre 5 and 55 C (ISO 11405). Os subgrupos 2 e 5 foram submetidos à ciclagem térmico-mecânica em um simulador de fadiga. Os espécimes foram colocados em uma basede metal num ângulo de 45 e os braquetes receberam impulsos de 1 bar e 4 Hz de frequência, por uma agulha de metal de 2.5 mm de diâmetro fixada na haste superior do equipamento. Foram submetidos a 100.000 ciclos mecânicos e 500 ciclos térmicos entre 5 and 55 C. O teste de RAC foi realizado emuma máquina universal de testes (1mm/min). Após orompimento da união foi realizada uma avaliação emmicroscopia óptica para avaliar a penetração adesivae o Índice de Permanência do Adesivo (IPA) sobreo esmalte. Os resultados mostraram maiores valores de RAC (14,70 ± 4,85 MPa) para o SEP. A CT não influenciou os resultados para o XT (NC- 11,44 MPa;TC - 11,20 MPa; TMC - 11,19 MPa), enquanto para oSEP, a CTM mostrou maiores valores (16,84 MPa)...
Several adhesive systems have been developed in the last decade. The aim of the current studywas to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with conventional primers (XT) or self-etching primers (SEP), by means of thermocycling (TC) and thermomechanical(TM) procedures. 90 bovine incisors were randomly divided into 2 groups (45 specimens each) for brackets bonding: XT (Transbond XT, 3M-Unitek,CA, USA); SEP (Transbond Plus SEP, 3M-Unitek,CA, USA). After bonding, groups were divided into 3subgroups: NC (no cycling)- 1 and 4 (n = 15 each),TMC 2 and 5 (n =15 each); and TC- 3 and 6 (n=15 each). The fatigue simulator was used for thethermal fatigue test of groups 3 and 6, which were submitted to thermal variation cycles - 500 cyles were carried out in between 5 and 55 C ( ISO 11405). Groups 2 and 5 were submitted to thermomechanicaltests by using the mechanical fatigue simulator. Thespecimens were placed at a metal base at an angleof 45, in a way that the 2.5 mm diameter metalneedle was fixed in the upper part of the cyclingmachine and could induce impulses of 1 bar loadintensity and 4 Hz frequency (4 cycles per second)on the bracket. The samples were submitted to 100000 mechanical cycles and 500 thermal cycles which varied from 5C to 55C. The SBS test was performed in a universal testing machine (1 mm/min). Afterdebonding, optic microscopic evaluation for adhesive penetration and Adhesive Remaining Index (ARI)analyses in the enamel surface were performed.The results showed higher SBS (14.70 ± 4.85 MPa)values for SEP. The SBS remained similar despitecycling (NC-11.44 MPa; TC-11.20 MPa; TMC-11.19MPa) for XT, meanwhile for SEP, ...
Sujet(s)
Bovins , Brackets orthodontiques , Résistance au cisaillement , Test de matériauxRÉSUMÉ
Este estudo avaliou (1) o efeito da altura do pilar, dos diferentes cimentos e da termociclagem e (2) o efeito dos diferentes cimentos e da ciclagem mecânica sobre a resistência máxima à tração (RMT) de restaurações implantossuportadas cimentadas. Pilares de titânio (UCLA), com alturas de 4,0 e 6,0 mm (1), ou 4,0 mm (2), foram torqueados com 32 N.cm a análogos de implantes HI. Infraestruturas em Co-Cr, jateadas com óxido de alumínio 50 µm foram cimentadas com: Fosfato de Zinco- FZ; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 e RelyX Temp NE- RXTNE. Os conjuntos foram submetidos aos ensaios de tração (0,5 mm/min) após: 1- armazenagem em saliva artificial a 37 ºC durante 24 h (controle), 2- termociclagem (10.000 ciclos, 5,0 e 55 °C, 30 s de imersão), ou 3-ciclagem mecânica (106 ciclos, 140 N, 15 Hz). Os dados foram analisados por (1) 3-way ANOVA e Dunnett, e (2) 2-way ANOVA e Tukey HSD (α=0,05). Independentemente da altura do pilar, não houve diferença nos resultados dos grupos sem termociclagem (p≥0,05). Após termociclagem, houve aumento (p<0,05) na RMT nos pilares de 6,0 mm. Após ciclagem mecânica, houve diminuição (p<0,05) nos resultados de RMT produzidos por RXL2. A altura do pilar influenciou os resultados do RXL2, que produziu RMT mais elevada com os pilares de 6,0 mm. Com exceção do RXL2, a ciclagem mecânica não comprometeu a RMT das infraestruturas cimentadas. Em determinadas condições, o RXTNE produziu RMT semelhante à alguns cimentos finais
This study evaluate (1) the effect of abutment height, different cements and thermocycling, and (2) the effect of different cements and cyclic loading on the ultimate tensile strength (UTS) of cement-retained/implant-supported cast restorations. UCLA-type abutments with 4.0 and 6.0-mm height (1), or 4.0-mm height (2) were torqued to with 32 N.cm to internal hexagon dental implant replicas. Copings casted in Co-Cr, sandblasted with 50-µm aluminum oxide particles were cemented with: Zinc Phosphate- ZP; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100-RXU100 and RelyX Temp NE- RXTNE. The assemblies were submitted to the tensile test (0.5 mm/min) after: 1- storage in artificial saliva at 37 °C for 24 h (control), 2-thermocycling (10,000 cycles, 5.0 and 55 ºC, 30-s dwell time), or 3- cyclic loading (106 cycles, 140 N, 15 Hz). Data were analyzed by (1) 3-way ANOVA and Dunnett tests, and (2) 2-way ANOVA and Tukey HSD tests (α=0.05). Regardless of the abutments' heights, no significant differences were found among the UTS of the nonthermocycled groups (p≥0.05). After thermocycling, an increasing in the UTS was observed for the 6.0-mm abutments (p<0.05). After cyclic loading, the UTS values produced by RXL2 were decreased (p<0.05). The abutment's heights used affected the RXL2 results, which produced higher results with the 6.0-mm abutments. With the exception of RXL2, cyclic loading did not detrimentally affect the UTS of the cemented castings. In some conditions, the provisional cement RXTNE produced similar UTS to some definitive cements
Sujet(s)
Analyse de variance , Cimentation , Implants dentaires , Rétention de prothèse dentaireRÉSUMÉ
O objetivo deste trabalho foi avaliar, por meio de microscopia eletrônica de varredura após ciclagem mecânica, a interface implante/pilar de um sistema de encaixe cone-morse. Quatro implantes, com sistema de encaixe do tipo cone-morse, receberam um pilar protético sólido, parafusado seguindo as recomendações de torque do fabricante (25 Ncm). As amostras receberam 345.600 ciclos em uma máquina de ensaio de fadiga, cuja carga aplicada foi de 80 N e frequência de 4 Hz. Estes implantes foram levados ao Microscópio Eletrônico de Varredura (MEV) e 32 imagens (16 imagens pré-ciclagem e 16 pós-ciclagem) das interfaces foram realizadas com aumentos de 1.000 e 5.000 vezes. As fendas marginais das interfaces, pré e pós-ciclagem mecânica, foram mensuradas com o auxílio de um software apropriado (Image Pró-plus 4.1). Os dados obtidos foram analisados pelo teste t Student (p = 0,05). Pelas análises morfológicas e estatísticas foi possível verificar diferenças significantes entre as tomadas de imagens, antes e depois do teste de ciclagem mastigatória simulada, em que o sistema de cone-morse obteve média das fendas pré-ciclagem mecânica de 3,34 ± 2,17 µm e média das fendas pós-ciclagem mecânica de 1,35 ± 0,64 µm. Desta forma, foi possível concluir que após a ciclagem mecânica, houve diminuição significativa da extensão do gap e da conexão pilar/implante do sistema cone-morse, com melhor adaptação e capacidade de selamento ao nível do microgap
The aim of this study was to measure and compare the implant-abutment interface of a Morse taper fitting system before and after cyclic loading. Four implants with tapered connections received an abutment solid screwed according to manufacturers recommendations (25 Ncm). All samples were subjected to 345,600 cycles using a fatigue-testing machine, under 80 N load and 4Hz frequency. After, 32 images (16 pre-cycling and 16 post-cycling) of these interfaces were investigated by SEM in increments of 1.000 x and 5.000 x. Marginal gaps of these interfaces before and after cyclic were measured with the aid of appropriate software (Image Pro-plus 4.1). Data were analyzed by Student´s t test (p = 0.05). By morphological analysis and statistics, we observed significant differences on the mean interfacial values before (3.34 ± 2.17 µm) and after (1.35 ± 0.64 µm) mechanical tests. Thus, it was possible to observe a significant decrease in gap extension, which determines better adaptation and sealing ability
Sujet(s)
Implants dentaires , Test de matériaux , Microscopie électronique à balayageRÉSUMÉ
Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...
Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fishers exact test and Pearsons linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...
Sujet(s)
Pose d'implant dentaire , Prothèse dentaire implanto-portée , Restauration coronoradiculaireRÉSUMÉ
Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...
Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fishers exact test and Pearsons linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...
Sujet(s)
Pose d'implant dentaire , Prothèse dentaire implanto-portée , Restauration coronoradiculaireRÉSUMÉ
O objetivo do estudo foi avaliar o efeito de diferentes níveis de desadaptação angular unilateral no sistema coroa-implante-parafuso de retenção de próteses implanto-suportadas confeccionadas a partir do cilindro UCLA usinado em liga de Co-Cr, submetidos à ciclagem mecânica. Foram confeccionadas 48 coroas metálicas fundidas em liga de Co-Cr sobre abutments UCLA hexagonais e parafusadas, com torque de 30N/cm, sobre 48 implantes osseointegráveis de hexágono externo, formando quatro grupos (n=12), sendo: A - coroas 100% adaptadas (controle); B, C e D - coroas com desadaptação angular unilateral de 50µm, 100µm e 200µm, respectivamente. Os corpos-de-prova foram incluídos em resina acrílica e submetidos à verificação inicial do destorque, antes da ciclagem mecânica. Em seguida, realizou-se os ensaios em um equipamento eletromecânico de ensaios de fadiga por mastigação, calibrado para operar com carga dinâmica oblíqua de 30N e 2Hz de freqüência, perfazendo os períodos de 200.000, 500.000 e 1.000.000 ciclos, todos iniciando do zero. Ao final de cada período foi verificado o destorque dos parafusos de retenção das coroas por meio de um medidor analógico de torque, e em seguida a substituição dos mesmos para início do período seguinte. Os dados obtidos foram tabulados e submetidos à ANOVA seguida do teste de Tukey (p<0.05). Os resultados mostraram que os quatro grupos estudados apresentaram diminuição significativa (p<0.05) na pré-carga durante a análise inicial, sem ensaio de fadiga, sendo que o grupo A (sem desadaptação) exibiu a menor perda. Os três períodos de ensaios não apresentaram diferença estatisticamente significante entre si quando analisados independentemente dos grupos, porém, quando os grupos foram analisados isoladamente, o grupo D mostrou diferença estatística p<0.05) entre o ciclo mais curso (200.000) e os demais, que não mostraram diferença entre si. De maneira geral, o grupo D apresentou as maiores perdas de pré-carga após os ensaios de fadiga, porém sem diferença estatística. dessa forma, pode-se concluir que os três níveis de desadaptação angular unilateral avaliados (50µm, 100µm e 200 µm) não infulenciaram significativamente (p>0.05) a redução de pré-carga após os três períodos de ensaio mecânico de fadiga quando comparados com o grupo controle e entre si. Os três diferentes períodos de ciclagem mecânica não influenciaram estatisticamente os valores dos grupos A, B e C (p>0.05). Apenas o grupo Dmostrou diferença estatística (p<0.05) entre os valores observados após o 1º período (200.000) e após os períodos mais longos (500.000 e 1.000.000)(AU)
The aim of this study was to evaluate the effect of unilateral angular misfit at different levels on a crown-implant-retention screw system of implant-supported prostheses fabricated with premachined Co-Cr UCLA abutment and submitted to mechanical cycling. 48 metallic crowns cast with Co-Cr alloy using hexagonal premachined Co-Cr UCLA abutment with plastic sleeve cast with Co-Cr were fabricated and screwed to 48 external hexagonal osseointegrated implants with 30N/cm. Four groups (n=12) were created. In group A (control group) the crowns did not present misfit, but in groups 8, C and D the crowns were fabricated with unilateral angular misfit of 50LJm, 100µm and 200µm respectively. The replicas were embedded in acrylic resin and submitted to detorque initial evaluation before mechanical cycling. After that, the fatigue testing was performed by an eletromechanic machine calibrated to apply an oblique dynamic load of 30N at a frequency of 2Hz, totalizing 200.000, 500.000 and 1.000.000 cycles. All the cycles started at 0. At the end of each period, the retention screw detorque was assessed by an analogic torque gauge. All the retention screws were substituted by a new screw before each cyclic period beginning. Data were tabulated and submitted to ANOVA and Tukey test (p<0.05). Results showed that all groups exhibited a significant decrease (p<0.05) in preload during the initial evaluation, without fatigue test, and this decrease was lower for group A (without misfit). There twas no significant difference among the three cyclic periods regardless groups. However, considering each group evaluation, group D presented statistic difference (p<0.05) between the shortest period (200.000) and the others that did not exhibited difference between them. Group D presented the greatest loss of preload after the cyclic periods, but without significant difference. So, it can be concluded that the levels of unilateral angular misfit evaluated (50µm, 100µm and 200µm) did not influence significantly (p>0.05) preload decrease after the three periods of fatigue testing when they were compared with control group and among them. The three periods of mechanical cycling did not influence significantly the values of groups A, 8 and C (p>0.05). Only group D revealed statistic difference (p<0.05) between the values observed after the first period (200.000) and the other longer periods (500.000 and 1.000.000)(AU)