Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 1.683
Filtre
1.
Article Dans Chinois | WPRIM | ID: wpr-1009117

Résumé

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Sujets)
Humains , Phénomènes biomécaniques , Plaques orthopédiques , Ostéosynthèse interne , Ostéosynthese intramedullaire , Fractures du tibia/chirurgie ,
2.
International Eye Science ; (12): 522-527, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1012814

Résumé

AIM:To investigate the effect of small incision lenticule extraction(SMILE)on the treatment of myopia patients, and the impact on corneal biomechanics.METHODS:Retrospective study. A total of 120 myopic patients(240 eyes)who were scheduled to undergo corneal refractive surgery in Anyang Eye Hospital from January 2020 to December 2021 were selected. The patients were divided into SMILE group(64 patients, 128 eyes)and transepithelial photorefractive keratectomy(TransPRK)group(56 patients, 112 eyes)according to the surgical treatment method. The two groups were compared in terms of uncorrected visual acuity, corneal biomechanics, corneal endothelial cell count, posterior corneal surface height and corneal surface regularity index at 1, 7 d, 1, 3, 6 mo and 1 a after surgery, and surgical complications.RESULTS:The uncorrected visual acuity of the SMILE group at 1, 7 d and 1 mo after surgery was better than that of the TransPRK group(all P<0.001), but there was no statistically significant difference between the groups at 3, 6 mo and 1 a after surgery(all P>0.05). Compared with preoperative values, corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, corneal resistance factor, and corneal hysteresis in both groups showed a first decreasing and then increasing trend after surgery. The corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, corneal resistance factor, and corneal hysteresis in the SMILE group at 1, 7 d and 1 mo after surgery were higher than those in the TransPRK group(all P<0.05), but there was no statistically significant difference between the groups at 3, 6 mo and 1 a after surgery(all P>0.05). There were no significant changes of corneal endothelial cell count and corneal posterior surface height in the two groups after surgery(all P>0.05). Furthermore, corneal surface regularity index of the two groups showed a first increasing and then decreasing trend after surgery, with no statistically significant difference between the groups(P>0.05), and there was no statistically significant difference in the incidence of postoperative complications between the groups(P>0.05).CONCLUSION:Compared with TransPRK, SMILE has less influence on corneal biomechanics, and better visual recovery in the early stage. There is no difference in long-term visual acuity between the two surgeries, and both have good safety and effectiveness.

3.
International Eye Science ; (12): 62-66, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1003507

Résumé

The finite element method(FEM)is a widely employed mathematical technique in mechanical research that divides an object into discrete and interacting finite elements. Medically, finite element analysis(FEA)enables the simulation of biomechanical experiments that are challenging to conduct. Orbital surgery poses significant challenges to ophthalmologists due to its inherent difficulty and steep learning curve. FEM enables the simulation and analysis of the mechanical properties of orbital tissue, offering a novel approach for diagnosing and treating orbital-related diseases. With technological advancements, FEM has significantly matured in the diagnosis and treatment of orbital diseases, becoming a popular area of research in orbital biomechanics. This paper reviewed the latest advancements in orbital FEM, encompassing the development of orbital FEA models, simulation of orbital structure, and its application in orbital-related diseases. Additionally, the limitations of FEM and future research directions are also discussed. As a digital tool for auxiliary diagnosis and treatment, orbital FEA will progressively unlock its potential for diagnosing and treating orbital diseases alongside technological advancements.

4.
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1559786

Résumé

Introducción: El estudio de los patrones del movimiento técnico deportivo implica analizar sus componentes biomecánicos, teniendo en cuenta el carácter multifactorial del rendimiento deportivo. Objetivo: Describir la mecánica del movimiento del tiro penalti en futbolistas categorías sub-12 y sub-17. Métodos: Estudio cuasi experimental de orden correlativo. Se estudiaron ocho variables biomecánicas: centro de gravedad en sus dos ejes, inclinación corporal, ángulos femorotibial antes del contacto, ángulos femorotibial luego del contacto, velocidad, aceleración y acierto. Se seleccionaron dos grupos independientes de 30 futbolistas del género masculino, se clasificaron por categorías sub-12 y sub-17, y se analizó su rendimiento mediante videoanálisis. Resultados: Hubo diferencias significativas a favor de la categoría sub-17 en las variables centro de gravedad en el eje X (p = 0,000), en inclinación corporal (p = 0,000), en velocidad (p = 0,000), y en aceleración y acierto (p = 0,000); y diferencias no significativas en el resto (centro de gravedad eje Y: p = 0,267; ángulos femorotibial antes del contacto: p = 0,459; ángulos femorotibial luego del contacto: p = 0,446; y aciertos: p = 0,226). Conclusiones: Todos los rangos promedios sobresalieron en la categoría sub-17, excepto en la variable aciertos, lo que implicó una mayor velocidad y aceleración del pie durante la ejecución del tiro a penal. Sin embargo, la precisión, como componente coordinativo, resultó fundamental en la efectividad del disparo.


Introduction: The study of the patterns of technical sports movement involves analyzing its biomechanical components, taking into account the multifactorial nature of sports performance. Objective: To describe the mechanics of the movement of the penalty kick in U-12 and U-17 football players. Methods: Quasi-experimental study of a correlative order. Eight biomechanical variables were studied: center of gravity in its two axes, body inclination, femorotibial angles before contact, femorotibial angles after contact, speed, acceleration and success. Two independent groups of 30 male footballers were selected, classified by U-12 and U-17 categories, and their performance was analysed through video analysis. Results: There were significant differences in favor of the sub-17 category in the variables center of gravity on the X axis (p = 0.000), body inclination (p = 0.000), speed (p = 0.000), and acceleration and accuracy (p = 0.000); and non-significant differences in the rest (center of gravity Y-axis: p = 0.267; femorotibial angles before contact: p = 0.459; femorotibial angles after contact: p = 0.446; and correct answers: p = 0.226). Conclusions: All the average ranges stood out in the U-17 category, except in the variable hits, which implied a greater speed and acceleration of the foot during the execution of the penalty kick. However, accuracy, as a coordinating component, was fundamental in the effectiveness of the shot.

5.
São Paulo med. j ; 142(2): e2022548, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1450518

Résumé

ABSTRACT BACKGROUND: Current research supports the fact that prophylactic ankle taping (AT) is effective in preventing ankle injuries in amateur and elite sports athletes. OBJECTIVE: This study aimed to investigate the effect of AT on balance, knee valgus during drop jump and single-leg countermovement jump (SL-CMJ) landings, and ankle range of motion (ROM) restriction in healthy participants. DESIGN AND SETTING: A cross-sectional observational study was conducted at the Universidad Europea de Madrid, Madrid, Spain. METHODS: Participants: Thirty-nine healthy individuals participated in this study and performed the movements under two conditions (with and without tape). Outcome measurements: ankle ROM, balance, SL-CMJ height, flight time, ground time, and knee valgus. Before any intervention, a random process was developed with a 1:1 allocation ratio, and the participants were assigned to groups A (tape-no tape) and B (no tape-tape). RESULTS: Significant differences between tape and no-tape moments were observed for drop jump knee valgus flexion (P = 0.007), with an increase in knee valgus in participants with ankle taping. Similarly, the Y-balance testshowed a significant decrease in all variables (P = 0.001 and), ankle dorsiflexion (P = 0.001) in participants with ankle taping. CONCLUSIONS: AT is effective for immediate ankle ROM restriction. However, an increase in knee valgus during drop jump task and a decrease in lower limb balance were observed during drop jump task. Based on these results, it can be concluded that AT application in healthy individuals should not be recommended as it results in increase in injury risk factors.

6.
São Paulo med. j ; 142(3): e2022578, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1450522

Résumé

ABSTRACT BACKGROUND: Ankle taping (AT) is effective in preventing ankle sprain injuries in most common sports and is employed in rehabilitation and prevention sports. OBJECTIVE: This study aimed to investigate the effectiveness of AT to restricting excessive frontal plane ankle movements in semi-professional basketball players throughout the training session. DESIGN AND SETTING: A cross-sectional study was performed at the Universidad Europea de Madrid. METHODS: Forty male and female semi-professional basketball players were divided into two groups. The ankle dorsiflexion range of motion (ROM) and interlimb asymmetries in a weight-bearing lunge position were evaluated at four time points: 1) with no tape, 2) before practice, at 30 min of practice, and 3) immediately after practice. RESULTS: In male basketball players, no differences were observed in the right and left ankles between the baseline and 30 min and between baseline and 90 min of assessment. In female athletes, significant differences were reported between baseline and pre-training assessments for the right ankle and also significant differences between baseline and 90 min in both ankles. CONCLUSIONS: Ankle taping effectively decreased the ankle dorsiflexion ROM in male and female basketball players immediately after application. However, ROM restriction was very low after 30 and 90 min, as assessed in a single basketball practice. Therefore, the classic taping method should be revised to develop new prophylactic approaches, such as the implementation of semi-rigid bracing techniques or the addition of active stripes during training or game pauses.

7.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Article Dans Portugais | LILACS, BBO | ID: biblio-1551332

Résumé

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Sujets)
Implants dentaires , Prothèses dentaires , Analyse des éléments finis , Phénomènes biomécaniques
8.
Pensar mov ; 21(2): e53154, jul.-dic. 2023. graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1558641

Résumé

Abstract Jump height continues to be widely used to predict power in humans. Individual progress is often monitored on the basis of estimated power, but prediction equations are based on group data. The objective of the study was to show that vertical jump performance (vJP) and mechanical power are poorly associated, particularly within individuals. Two experiments are presented. First, 52 physically active male college students performed five maximal vertical jumps each. Second, three young male participants performed 50 maximal jumps each. Participants rested for 1 minute between jumps. vJP was calculated from kinematic data as peak body center of mass (BCOM) minus standing BCOM; peak power (PEAKPWR) was calculated from the vertical ground reaction force registered by a force plate, and average power (MEANPWR) during propulsion from the change in potential energy of BCOM. Regression analyses were performed using standardized vJP scores as the predictor variable and standardized power scores as the resulting variables, expecting an identity function of y = x (intercept = 0, slope = 1) and R2 = 1. In experiment 1, the model for zPEAKPWR R2 = 0.9707 (p < 0.0001) but slope (0.3452) ≠ 1 (p < 0.0001). The model for zMEANPWR R2 = 0.9239 (p < 0.0001); nevertheless, slope (0.4257) ≠ 1 (p < 0.0001). In experiment 2, all individual models for zPEAKPWR and zMEANPWR resulted in poor associations (R2 ≤ 0.21) and slopes ≠ 1 (p≤0.001). In conclusion, regression analysis for individuals, and even for groups, confirms that vJP is a poor predictor of mechanical power.


Resumo A altura do salto ainda é amplamente usada para prever a potência em humanos. O progresso individual é frequentemente monitorado usando a estimativa de potência, mas as equações de previsão são baseadas em dados de grupo. O objetivo do estudo é demonstrar que a altura do salto vertical (ASv) e a potência mecânica têm uma correlação débil, principalmente em um mesmo indivíduo. São apresentados dois experimentos: primeiro, 52 estudantes universitários fisicamente ativos realizaram cinco saltos verticais máximos cada um; segundo, três participantes do sexo masculino realizaram 50 saltos máximos cada um. Os participantes descansaram por 1 minuto entre os saltos. A ASv foi calculada a partir de dados cinemáticos como a posição mais alta do centro de massa corporal (CMC) menos o CMC em pé; a potência de pico (PEAKPWR) foi calculada a partir da força de reação vertical registrada por uma plataforma de força e a potência média (MEANPWR) durante a propulsão a partir da mudança na energia potencial do CMC. As análises de regressão foram realizadas usando os escores da ASv padronizados como variável preditora e os escores de potência padronizados como variáveis de resultado, com a expectativa de obter uma função de identidade y = x (interceptação = 0, inclinação = 1) e R2 = 1. No experimento 1, o modelo para zPEAKPWR produziu R2 = 0,9707(p < 0,0001), mas a inclinação (0,3452) ≠ 1 (p = 8,7x10-15). O modelo para zMEANPWR apresentou R2 = 0,9239 (p < 0,0001); no entanto, a inclinação (0,4257) ≠ 1 (p = 1,15x10-5). No experimento 2, todos os modelos individuais para zPEAKPWR e zMEANPWR apresentaram associações débeis (R2 ≤ 0,21) e inclinações ≠ 1(p ≤ 0,001). Em conclusão, a análise de regressão para indivíduos e até mesmo para grupos confirma que a ASv é um indicador débil da potência mecânica.


Resumen La altura del salto se sigue usando ampliamente para predecir la potencia en seres humanos. El progreso individual, a menudo, se monitorea usando una estimación de la potencia, pero las ecuaciones de predicción se basan en datos grupales. El estudio pretende demostrar que la altura del salto vertical (ASv) y la potencia mecánica tienen una pobre correlación, particularmente en un mismo individuo. Se presentan dos experimentos; primero, 52 estudiantes universitarios físicamente activos ejecutaron cinco saltos verticales máximos cada uno; segundo, tres participantes masculinos ejecutaron 50 saltos máximos cada uno. Los participantes descansaron 1 minuto entre saltos. ASv se calculó a partir de los datos cinemáticos como posición más alta del centro de masa corporal (CDM) menos CDM de pie; la potencia pico (PEAKPWR) se calculó a partir de la fuerza vertical de reacción registrada por una plataforma de fuerza y la potencia promedio (MEANPWR) durante la propulsión a partir del cambio en la energía potencial del CDM. Se realizaron análisis de regresión usando puntajes estandarizados de ASv como la variable predictora y puntajes estandarizados de potencia como las variables resultantes, con la expectativa de obtener una función de identidad y = x (intercepto = 0, pendiente = 1) y R2 = 1. En el experimento 1, el modelo para zPEAKPWR arrojó R2 = 0.9707 (p <.0001) pero la pendiente (0.3452) ≠ 1 (p = 8.7x10-15). El modelo para zMEANPWR dio R2 = 0.9239 (p < .0001); sin embargo, la pendiente (0.4257) ≠ 1 (p = 1.15x10-5). En el experimento 2, todos los modelos individuales para zPEAKPWR y zMEANPWR arrojaron asociaciones débiles (R2 ≤ 0.21) y pendientes ≠ 1 (p ≤ .001). En conclusión, el análisis de regresión para individuos y aún para grupos confirma que la ASv es un pobre predictor de la potencia mecánica.

9.
Podium (Pinar Río) ; 18(2)ago. 2023.
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1448881

Résumé

El deporte como fenómeno social, se desarrolla en la actualidad simultáneamente con los adelantos de la ciencia y la tecnología; en este contexto, juega un papel importante la biomecánica que asegura las bases para un verdadero entrenamiento técnico, de ahí que el trabajo está dirigido al uso de la biomecánica en la técnica de pitcheo. Para dar respuesta a esta temática se concibe como objetivo aplicar estudios biomecánicos a la técnica de pitcheo en los lanzadores del equipo de béisbol La Isla de la Juventud. Se utilizaron como métodos el análisis de documentos, la revisión bibliográfica, la observación científica, la entrevista y la técnica del análisis de video con ayuda de un Dron; ello permitió medir magnitudes y valorar el comportamiento de las características que poseen los movimientos ejecutados por los lanzadores objeto de estudio. También, se emplearon dos técnicas de mediciones, una a través de la filmación y otra por procesamiento cinemático con el uso de los softwares como Tracker y Kinovea. La muestra estuvo conformada por ocho sujetos, distribuidos en tres atletas, dos entrenadores y tres investigadores; esto permitió determinar las características de la distancia de paso, ángulo que forma el brazo de lanzar con respecto a la cabeza, altura de la pelota y la velocidad de la pelota ejecutados por los lanzadores investigados.


O esporte, como fenômeno social, está se desenvolvendo simultaneamente com os avanços da ciência e da tecnologia; nesse contexto, a biomecânica desempenha um papel importante para garantir a base de um verdadeiro treinamento técnico, portanto, o trabalho visa ao uso da biomecânica na técnica de arremesso. Para responder a essa questão, o objetivo foi aplicar estudos biomecânicos à técnica de arremesso nos arremessadores do time de beisebol La Isla de la Juventud. Os métodos utilizados foram a análise de documentos, a revisão bibliográfica, a observação científica, a entrevista e a técnica de análise de vídeo com a ajuda de um drone, o que permitiu medir as magnitudes e avaliar o comportamento das características dos movimentos executados pelos arremessadores em estudo. Além disso, foram utilizadas duas técnicas de medição, uma por meio de filmagem e outra por meio de processamento cinemático com o uso de softwares como o Tracker e o Kinovea. A amostra foi composta por oito sujeitos, distribuídos em três atletas, dois técnicos e três pesquisadores, o que nos permitiu determinar as características da distância de arremesso, do ângulo do braço de arremesso em relação à cabeça, da altura da bola e da velocidade da bola executada pelos arremessadores investigados.


Sport as a social phenomenon, currently develops simultaneously with the advances of science and technology; in this context, biomechanics plays an important role that ensures the bases for true technical training; hence the work is directed to the use of biomechanics in throwing technique. To respond to this issue, the objective is to apply biomechanical studies to the throwing technique in the throwers of the La Isla de la Juventud baseball team. Document analysis, bibliographic review, scientific observation, interview and the technique of video analysis with the help of a drone were used as methods; this made it possible to measure magnitudes and assess the behavior of the characteristics of the movements executed by the throwers under study. Also, two measurement techniques were used, one through filming and the other by kinematic processing with the use of software such as Tracker and Kinovea. The sample consisted of eight subjects, divided into three athletes, two coaches and three researchers; this allowed to determine the characteristics of the throw distance, the angle formed by the throwing arm with respect to the head, the height of the ball, and the speed of the ball executed by the investigated throwers.

10.
Braz. dent. j ; 34(1): 80-88, Jan.-Feb. 2023. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1420569

Résumé

Abstract This study aimed to evaluate the effect of different loading conditions on the mechanical behavior and stress distribution of a leucite-reinforced glass-ceramic. Plate-shaped ceramic specimens were obtained from leucite-reinforced glass-ceramic (1.5 × 8.4 × 8.3 mm) and adhesively cemented to a dentin analog substrate. Monotonic and cyclic contact fatigue tests were performed to simulate sphere-to-flat contact, using a 6 mm diameter spherical piston; and flat-to-flat contact, using a 3 mm diameter flat piston. For the monotonic test (n=20), a gradual compressive load (0.5 mm/min) was applied to the specimen using a universal testing machine. Failure load data were analyzed with Weibull statistics. The cyclic contact fatigue test was performed using protocols (load and a number of cycles) defined by the boundary technique (n=30). Fatigue data were analyzed using an inverse power law relationship and Weibull-lifetime distribution. The stress distribution was investigated using Finite Element Analysis (FEA). The monotonic and the fatigue Weibull modulus were similar among the two contact conditions. In fatigue, the slow crack growth exponent was greater for sphere-to-flat contact, which indicates that the load level had a greater effect on the specimen's probability of failure. In conclusion, FEA showed different stress distribution for the tested loading conditions. The stress distribution and probability of fatigue failure of specimens tested in sphere-to-flat contact showed greater dependency to load level.


Resumo O objetivo deste estudo é avaliar o efeito de diferentes condições de carregamento no comportamento mecânico e na distribuição de tensões de uma vitrocerâmica reforçada com leucita. Amostras cerâmicas em forma de lâminas foram obtidas a partir de vitrocerâmica reforçada com leucita (1,5 × 8,4 × 8,3 mm) e cimentadas adesivamente a um substrato análogo de dentina. Ensaios de carga de compressão monotônica e fadiga foram realizados para simular o contato esfera-plano, usando um pistão esférico de 6 mm de diâmetro; e contato plano com plano, usando um pistão plano de 3 mm de diâmetro. Para o ensaio de carga de compressão monotônica (n=20), foi aplicada uma carga compressiva gradual (0,5 mm/min) ao corpo-de-prova usando uma máquina de ensaio universal. Os dados de carga de fratura foram analisados de acordo com a distribuição de Weibull. O teste de fadiga foi realizado com os protocolos (carga e número de ciclos) definidos pela técnica de boundary (n=30). Os dados de fadiga foram analisados usando uma relação de tempo de vida - tensão de lei da potência inversa (IPL- inverse power law). A distribuição de tensões foi investigada usando análise de elementos finitos (AEF). O módulo de Weibull para teste de compressão monotônico e de fadiga foram semelhantes entre as duas condições de contato. Em fadiga, o expoente de crescimento sub-crítico da trinca foi maior para o contato esfera-plano, o que indica que o nível de carga teve um efeito maior na probabilidade de falha do corpo-de-prova. Em conclusão, AEF apresentou distribuição de tensões diferente para as condições de carregamento testadas. A distribuição de tensões e a probabilidade de falha em fadiga dos corpos-de-prova testados utilizando o contato esfera-plano apresentaram maior dependência do nível de carga.

11.
Journal of Forensic Medicine ; (6): 471-477, 2023.
Article Dans Anglais | WPRIM | ID: wpr-1009380

Résumé

The finite element method (FEM) is a mathematical method for obtaining approximate solutions to a wide variety of engineering problems. With the development of computer technology, it is gradually applied to the study of biomechanics of human body. The application of the combination of FEM and biomechanics in exploring the relationship between vascular injury and disease, and pathological mechanisms will be a technological innovation for traditional forensic medicine. This paper reviews the construction and development of human vascular FEM modeling, and its research progress on the vascular biomechanics. This paper also looks to the application prospects of FEM modeling in forensic pathology.


Sujets)
Humains , Simulation numérique , Modèles biologiques , Phénomènes biomécaniques , Analyse des éléments finis , Médecine légale
12.
Journal of Biomedical Engineering ; (6): 1185-1191, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1008949

Résumé

A novel structural dynamics test method and device were designed to test the biomechanical effects of dynamic axial loading on knee cartilage and meniscus. Firstly, the maximum acceleration signal-to-noise ratio of the experimental device was calculated by applying axial dynamic load to the experimental device under unloaded condition with different force hammers. Then the experimental samples were divided into non-specimen group (no specimen loaded), sham specimen group (loaded with polypropylene samples) and bovine knee joint specimen group (loaded with bovine knee joint samples) for testing. The test results show that the experimental device and method can provide stable axial dynamic load, and the experimental results have good repeatability. The final results confirm that the dynamic characteristics of experimental samples can be distinguished effectively by this device. The experimental method proposed in this study provides a new way to further study the biomechanical mechanism of knee joint structural response under axial dynamic load.


Sujets)
Animaux , Bovins , Phénomènes biomécaniques , Articulation du genou/physiologie , Ménisque , Phénomènes mécaniques , Mise en charge
13.
Article Dans Chinois | WPRIM | ID: wpr-981739

Résumé

The shoulder joint is the most flexible joint in the body with the largest range of motion, and the movement pattern is more complex. Accurate capture of three-dimensional motion data of the shoulder joint is crucial for biomechanical evaluation. Optical motion capture systems offer a non-invasive and radiation-free method to capture shoulder joint motion data during complex movements, enabling further biomechanical analysis of the shoulder joint. This review provides a comprehensive overview of optical motion capture technology in the context of shoulder joint movement, including measurement principles, data processing methods to reduce artifacts from skin and soft tissues, factors influencing measurement results, and applications in shoulder joint disorders.


Sujets)
Humains , Épaule , , Phénomènes biomécaniques , Membre supérieur , Articulation glénohumérale , Mouvement , Amplitude articulaire
14.
Article Dans Chinois | WPRIM | ID: wpr-981674

Résumé

OBJECTIVE@#To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.@*METHODS@#One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.@*RESULTS@#The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.@*CONCLUSION@#The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.


Sujets)
Humains , Os lunatum/chirurgie , Analyse des éléments finis , Titane , Articulation du poignet/chirurgie , Membres artificiels , Amplitude articulaire , Phénomènes biomécaniques
15.
Article Dans Chinois | WPRIM | ID: wpr-981653

Résumé

OBJECTIVE@#The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.@*METHODS@#Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.@*RESULTS@#In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).@*CONCLUSION@#Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.


Sujets)
Humains , Femelle , Sujet âgé , Analyse des éléments finis , Phénomènes biomécaniques , Ostéosynthèse interne/méthodes , Fractures de la hanche/chirurgie , Plaques orthopédiques , Tête du fémur , Fractures du fémur/chirurgie
16.
Article Dans Chinois | WPRIM | ID: wpr-981625

Résumé

OBJECTIVE@#To review the research progress of the biomechanical study of the Bristow-Latarjet procedure for anterior shoulder dislocation.@*METHODS@#The related biomechanical literature of Bristow-Latarjet procedure for anterior shoulder dislocation was extensively reviewed and summarized.@*RESULTS@#The current literature suggests that when performing Bristow-Latarjet procedure, care should be taken to fix the bone block edge flush with the glenoid in the sagittal plane in the direction where the rupture of the joint capsule occurs. If traditional screw fixation is used, a double-cortical screw fixation should be applied, while details such as screw material have less influence on the biomechanical characteristics. Cortical button fixation is slightly inferior to screws in terms of biomechanical performance. The most frequent site of postoperative bone resorption is the proximal-medial part of the bone block, and the cause of bone resorption at this site may be related to the stress shielding caused by the screw.@*CONCLUSION@#There is no detailed standardized guidance for bone block fixation. The optimal clinical treatment plan for different degrees of injury, the factors influencing postoperative bone healing and remodeling, and the postoperative osteoarticular surface pressure still need to be further clarified by high-quality biomechanical studies.


Sujets)
Humains , Luxation de l'épaule/chirurgie , Articulation glénohumérale/chirurgie , Phénomènes biomécaniques , Instabilité articulaire/chirurgie , Résorption osseuse , Arthroscopie/méthodes
17.
Article Dans Chinois | WPRIM | ID: wpr-970476

Résumé

This study aimed to investigate the effects of nanoparticles PLGA-NPs and mesoporous silicon nanoparticles(MSNs) of different stiffness before and after combination with menthol or curcumol on the mechanical properties of bEnd.3 cells. The particle size distributions of PLGA-NPs and MSNs were measured by Malvern particle size analyzer, and the stiffness of the two nanoparticles was quantified by atomic force microscopy(AFM). The bEnd.3 cells were cultured in vitro, and the cell surface morphology, roughness, and Young's modulus were examined to characterize the roughness and stiffness of the cell surface. The changes in the mechanical properties of the cells were observed by AFM, and the structure and expression of cytoskeletal F-actin were observed by a laser-scanning confocal microscope. The results showed that both nanoparticles had good dispersion. The particle size of PLGA-NPs was(98.77±2.04) nm, the PDI was(0.140±0.030), and Young's modulus value was(104.717±8.475) MPa. The particle size of MSNs was(97.47±3.92) nm, the PDI was(0.380±0.016), and Young's modulus value was(306.019±8.822) MPa. The stiffness of PLGA-NPs was significantly lower than that of MSNs. After bEnd.3 cells were treated by PLGA-NPs and MSNs separately, the cells showed fine pores on the cell surface, increased roughness, decreased Young's modulus, blurred and broken F-actin bands, and reduced mean gray value. Compared with PLGA-NPs alone, PLGA-NPs combined with menthol or curcumol could allow deepened and densely distributed surface pores of bEnd.3 cells, increase roughness, reduce Young's modulus, aggravate F-actin band breakage, and diminish mean gray value. Compared with MSNs alone, MSNs combined with menthol could allow deepened and densely distributed surface pores of bEnd.3 cells, increase roughness, reduce Young's modulus, aggravate F-actin band breakage, and diminish mean gray value, while no significant difference was observed in combination with curcumol. Therefore, it is inferred that the aromatic components can increase the intracellular uptake and transport of nanoparticles by altering the biomechanical properties of bEnd.3 cells.


Sujets)
Animaux , Souris , Menthol/pharmacologie , Actines/métabolisme , Cellules endothéliales/métabolisme , Nanoparticules/composition chimique
18.
Journal of Integrative Medicine ; (12): 254-267, 2023.
Article Dans Anglais | WPRIM | ID: wpr-982680

Résumé

OBJECTIVE@#This study aims to clarify how the stimulation of acupuncture points is achieved by needles with different surface texture during acupuncture; it also seeks to lessen injury at the insertion site and increase the therapeutic efficacy of acupuncture, by simulating the mechanical effects of various needle surface patterns on Zusanli (ST36) without changing the radius of acupuncture needles.@*METHODS@#Five acupuncture needle models with different surface patterns, including the smooth needle, the lined needle, the ringed needle, the left-hand threaded needle and the right-hand threaded needle, and a layered model of the Zusanli acupoint were used to investigate how to reduce tissue damage and increase stimulation during acupuncture treatment. Puncturing of the skin as well as lifting-inserting and twisting needle manipulations were simulated using these models, and the degree of damage and force of stimulation caused by the acupuncture needles with different surface patterns during acupuncture were compared.@*RESULTS@#The smooth needle and the lined needle caused the least tissue damage during insertion, while the left-hand threaded and the right-hand threaded needles caused the most damage. The ringed needle, the left-hand threaded needle and the right-hand threaded needle stimulated the acupoint tissue more during lifting-inserting manipulations, while the lined needle and the smooth needle produced less stimulation. The stimulation of the lined needle on the acupoint tissue was the largest during twisting manipulation, whereas the left-hand threaded needle and the right-hand threaded needle had smaller effects. In lifting-inserting and twisting manipulations, both the left-hand threaded needle and right-hand threaded needle provided more stimulation, but the torsion direction in which they produced better stimulation was the opposite.@*CONCLUSION@#According to the simulation results, the ringed pattern enhances stimulation best in the lifting-inserting manipulation, whereas the lined pattern enhances stimulation best in the twisting manipulation. Both the right-hand and left-hand thread patterns have certain enhancing effects in these two operations. Taking the geometric properties of the pattern into account, the left-hand thread pattern and the right-hand thread pattern have the geometric characteristics of both the lined pattern and the ringed pattern. To conclude, a pattern perpendicular to the movement direction during the acupuncture manipulation creates more stimulation. These results have significance for future needle design. Please cite this article as: Sun MZ, Wang X, Li YC, Yao W, Gu W. Mechanical effects of needle texture on acupoint tissue. J Integr Med. 2023; 21(3): 254-267.


Sujets)
Points d'acupuncture , Aiguilles , Thérapie par acupuncture/méthodes , Main
19.
Journal of Medical Biomechanics ; (6): E451-E457, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987970

Résumé

Dendritic cells (DCs) are now known as the most powerful antigen-presenting cells in vivo, with efficient antigen uptaking, and processing capabilities. They can present antigens to naïve T cells in secondary lymphoid tissues, thereby induce immune response or tolerance, and play a key role in initiating and amplifying innate and adaptive immunity. DCs experience complex chemical and mechanical microenvironment changes and show different mechanophenotypes and immunophenotypes in the process of exerting their physiological functions. Deeply understanding the chemical and mechanical factors that regulate the mechanophenotypes and immunophenotypes of DCs is a prerequisite for using DCs to treat immune related diseases. In this review, the progress in the biomechanics and mechanobiology research of DCs was mainly introduced, and their potential applications and future development directions in the treatment of immune related diseases were explored.

20.
Journal of Medical Biomechanics ; (6): E420-E432, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987968

Résumé

The cardiovascular system plays a crucial role in the entire organism. It performs many important functions, such as providing organs and tissues with nutrients, hormones, delivering oxygen to cells, and maintaining physiological temperature. For a long time, accurately identifying the nonlinear and anisotropic mechanical properties of the vascular wall within the body has been regarded as a key challenge in cardiovascular biomechanics, as these properties are critical determinants of overall cardiac function. Currently, the roles of mechanical and tissue properties in cardiovascular diseases such as arterial aneurysms and atherosclerosis remain hot topics in both basic and clinical researches. This review aims to summarize the latest research advances in the field of cardiovascular biomechanics and mechanobiology in the year 2022. In terms of cardiovascular biomechanics, researchers focus on the structure, function, and pathophysiology of the cardiovascular system, and use experimental methods such as mechanical modeling to study these issues. These include studies about biomechanical properties of diseases such as atherosclerosis, arterial aneurysms, and myocardial infarction, as well as the development and testing of treatment methods based on dynamics of the cardiovascular system. In terms of mechanobiology, researchers explore mechanical properties of cardiovascular cells and extracellular matrix, including prediction of cell mechanical properties based on machine learning, studies of biological material mechanical properties, and the role of mechanical properties in cardiovascular cell phenotype changes. These research findings provide new ideas and methods for diagnosing and treating cardiovascular diseases and offer new insights into researches in biomechanics and mechanobiology fields.

SÉLECTION CITATIONS
Détails de la recherche