1.
Article de Chinois | WPRIM | ID: wpr-1009223

RÉSUMÉ

OBJECTIVE@#To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.@*METHODS@#Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.@*RESULTS@#The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.@*CONCLUSION@#Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.


Sujet(s)
Mâle , Humains , Adulte , Analyse des éléments finis , Radial Head and Neck Fractures , Vis orthopédiques , Phénomènes biomécaniques , Fractures du radius/chirurgie , Ostéosynthèse interne/méthodes , Plaques orthopédiques , Fractures comminutives
2.
Article de Chinois | WPRIM | ID: wpr-1009116

RÉSUMÉ

OBJECTIVE@#To review the advancement made in the understanding of valgus impacted proximal humeral fracture (PHF).@*METHODS@#The domestic and foreign literature about the valgus impacted PHF was extensively reviewed and the definition, classification, pathological features, and treatment of valgus impacted PHFs were summarized.@*RESULTS@#PHF with a neck shaft angle ≥160° is recognized as a valgus impacted PHF characterized by the preservation of the medial epiphyseal region of the humeral head, which contributes to maintenance of the medial periosteum's integrity after fracture and reduces the occurrence of avascular necrosis. Therefore, the valgus impacted PHF has a better prognosis when compared to other complex PHFs. The Neer classification designates it as a three- or four-part fracture, while the AO/Association for the Study of Internal Fixation (AO/ASIF) categorizes it as type C (C1.1). In the management of the valgus impacted PHF, the selection between conservative and surgical approaches is contingent upon the patient's age and the extent of fracture displacement. While conservative treatment offers the advantage of being non-invasive, it is accompanied by limitations such as the inability to achieve anatomical reduction and the potential for multiple complications. Surgical treatment includes open reduction combined with steel wire or locking plate and/or non-absorbable suture, transosseous suture technology, and shoulder replacement. Surgeons must adopt personalized treatment strategies for each patient with a valgus impacted PHF. Minimally invasive surgery helps to preserve blood supply to the humeral head, mitigate the likelihood of avascular necrosis, and reduce postoperative complications of bone and soft tissue. For elderly patients with severe comminuted and displaced fractures, osteoporosis, and unsuitable internal fixation, shoulder joint replacement is the best treatment option.@*CONCLUSION@#Currently, there has been some advancement in the classification, vascular supply, and management of valgus impacted PHF. Nevertheless, further research is imperative to assess the clinical safety, biomechanical stability, and indication of minimally invasive technology.


Sujet(s)
Sujet âgé , Humains , Plaques orthopédiques , Fils métalliques , Ostéosynthèse interne/effets indésirables , Fractures comminutives/chirurgie , Fractures de l'humérus , Ostéonécrose , Études rétrospectives , Fractures de l'épaule/chirurgie , Résultat thérapeutique
3.
Article de Chinois | WPRIM | ID: wpr-1009117

RÉSUMÉ

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Sujet(s)
Humains , Phénomènes biomécaniques , Plaques orthopédiques , Ostéosynthèse interne , Ostéosynthese intramedullaire , Fractures du tibia/chirurgie , Tibial Plateau Fractures
4.
Odontol. vital ; (39): 27-39, jul.-dic. 2023. tab, graf
Article de Espagnol | LILACS, SaludCR | ID: biblio-1550585

RÉSUMÉ

RESUMEN Introducción: Los tratamientos para fracturas de órbita se basan en la corrección del defecto de las lesiones orbitarias de tipo blow in y blow out (o de estallido), mediante diversas placas y mallas biocompatibles con el organismo, dándose una cicatrización de primera generación evitando un callo óseo y una fijación más rígida. Para el diagnóstico de este tipo de lesiones tenemos inflamación periorbitaria, enoftalmos, diplopía, equimosis, hemorragia subconjuntival. Existen diversos materiales reconstructivos siendo estos compuestos por distintas materias primas, como son los aloplásticos y autógenos; donde encontramos varios tipos como placas de titanio y las placas reabsorbibles siendo estas las más comunes y usadas actualmente, por su bajo estímulo a reabsorciones óseas y evitando efectos secundarios a largo plazo. Estas placas presentan diversos grados de ductilidad y resistencia. Se informó sobre varias complicaciones según el tipo de placas como es la cicatrización, las cirugías postquirúrgicas en caso de placas de titanio, etc. El objetivo de esta revisión es la evaluación de la eficacia las placas reabsorbibles versus placas de titanio en fracturas de órbita. Materiales y métodos: La investigación es de carácter documental, descriptivo y no experimental. En el cual se emplea una metodología de identificación e inclusión de artículos científicos tipo prisma. Resultados y conclusiones: Se verificaron las ventajas y desventajas tanto de las placas reabsorbibles como las de titanio siendo estas similares en la biocompatibilidad con el organismo humano, así como también varias diferencias como el soporte, fuerzas, resistencia de estas, concluyendo que es debatible el material ideal para tratar fracturas de órbita. Se seleccionaron artículos tomando en cuenta el título y objetivos; considerando estudios comparativos, revisiones sistemáticas, revisiones de literatura, los cuales comprendían criterios con respecto a fracturas de órbita y tratamientos quirúrgicos. La búsqueda arrojó 55 artículos en PubMed, 65 en Google, 4 en Scielo y 29 en Science direct, de los cuales se excluyeron libros, monografías, estudios experimentales, dando como resultado 21 artículos para el desarrollo de esta revisión bibliográfica. Y que fueron leídos y analizados en su totalidad, estudiando los objetivos, metodología y conclusión de cada uno de ellos para la posterior comparación.


ABSTRACT Introduction: Treatments for orbit fractures are based on the correction of the defect of blow in and blow out orbital injuries, by means of various plates and meshes biocompatible with the organism, giving a first-generation healing avoiding a bony callus and a more rigid fixation. For the diagnosis of this type of lesions we have periorbital inflammation, enophthalmos, diplopia, ecchymosis, subconjunctival hemorrhage. There are several reconstructive materials being these composed of different raw materials, such as alloplastic and autogenous, where we find several types such as titanium plates and resorbable plates being these the most common and currently used, for its low stimulus to bone resorption and avoiding long-term side effects. These plates have different degrees of ductility and resistance. Several complications have been reported depending on the type of plates, such as scarring, post-surgical surgeries in the case of titanium plates, etc. The objective of this review is to evaluate the efficacy of resorbable versus titanium plates in orbital fractures. Materials and methods: This research are a documentary, descriptive and non-experimental nature. A prism-type methodology of identification and inclusion of scientific articles was used. Results and conclusions: The advantages and disadvantages of both resorbable and titanium plates were verified, being these similar in biocompatibility with the human organism, as well as several differences such as support, forces, resistance of the same, concluding that it is debatable. The ideal material to treat orbital fractures. Articles were selected considering the title and objectives; considering comparative studies, systematic reviews, literature reviews, which included criteria regarding orbital fractures and surgical treatments. The search yielded 55 articles in PubMed, 65 in Google, 4 in Scielo and 29 in Science direct, from which books, monographs, experimental studies were excluded, resulting in 21 articles for the development of this bibliographic review. The 21 articles were read and analyzed in their entirety, studying the objectives, methodology and conclusion of each one of them for subsequent comparison.


Sujet(s)
Humains , Orbite/traumatismes , Plaques orthopédiques , Titane , Matériaux biocompatibles/usage thérapeutique , Fractures osseuses/chirurgie
5.
Actual. osteol ; 19(3): 199-210, Sept - Dic 2023. ilus, tab
Article de Espagnol | LILACS, UNISALUD, BINACIS | ID: biblio-1555762

RÉSUMÉ

Introducción: el músculo pronador cuadrado funciona como un estabilizador dinámico de la articulación radiocubital distal. Su reparación posterior a la fijación interna con placa de bloqueo volar en fracturas distales del radio es controvertida. Objetivo: determinar si la reparación del músculo pronador cuadrado influye en los resultados clínicos y funcionales de pacientes con fractura de radio distal que se sometieron a reducción abierta y fijación interna con placa de bloqueo volar. Materiales y métodos: se realizó una revisión sistemática y metanálisis. Las bases de datos analizadas fueron PubMed/Medline, Embase y Bireme/Lilacs (búsqueda realizada hasta el 20 de febrero del año 2023). Los términos de búsqueda fueron: distal radius fracture AND volar plate AND pronator quadratus. Se determinó la calidad metodológica según el manual de revisiones Cochrane. Resultados: en total se incluyeron 4 ensayos clínicos aleatorizados de adecuada calidad metodológica, lo cual corresponde al análisis de 213 participantes. Existen mejores resultados en la puntuación DASH a los 12 meses de seguimiento en el grupo de no reparación del músculo pronador cuadrado DM 2,8 [IC 95%: 0,51;5,10]. No hubo diferencias significativas al año de seguimiento en las puntuaciones de dolor, rangos de movilidad de la muñeca, fuerza de agarre e incidencia de complicaciones. Conclusión: no existe evidencia que sustente la reparación rutinaria del músculo pronador cuadrado posterior a la fijación interna con placa de bloqueo volar en las fracturas de radio distal. (AU)


Introduction: the pronator quadratus muscle functions as a dynamic stabilizer of the distal radioulnar joint, and its repair after internal fixation with volar locking plate in distal radius fractures is controversial. Objective: to determine whether the repair of the pronator quadratus muscle influences the clinical and functional outcomes of patients with distal radius fracture who underwent open reduction and internal fixation with volar locking plate. Materials and methods: a systematic review and meta-analysis were conducted. The analyzed databases were Pubmed/Medline, Embase, and Bireme/Lilacs (search performed until February 20th, 2023). The search terms were distal radius fracture AND volar plate AND pronator quadratus. Methodological quality was determined according to the Cochrane Reviewer's Handbook. Results: a total of 4 randomized clinical trials of adequate methodological quality, corresponding to the analysis of 213 participants, were included. Better DASH scores were observed at 12 months of follow-up in the non-repair group of the pronator quadratus muscle, with a mean difference of 2.8 [95% CI 0.51; 5.10]. There were no significant differences at one-year follow-up in pain scores, wrist mobility ranges, grip strength, and incidence of complications. Conclusion: there is no evidence to support routine repair of the pronator quadratus muscle after internal fixation with volar locking plate in distal radius fractures. (AU)


Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Fractures du radius/chirurgie , Procédures de chirurgie opératoire/méthodes , Traumatismes du poignet/chirurgie , Ostéosynthèse interne/méthodes , Plaques orthopédiques , Mesure de la douleur , Essais contrôlés randomisés comme sujet , Amplitude articulaire , Résultat thérapeutique , Ostéosynthèse interne/rééducation et réadaptation
6.
Rev. Bras. Ortop. (Online) ; 58(2): 326-330, Mar.-Apr. 2023. tab
Article de Anglais | LILACS | ID: biblio-1449798

RÉSUMÉ

Abstract Objective Medial open wedge high tibial osteotomy (MOWHTO) significantly relieves pain in the medial joint line in medial compartment osteoarthritis of the knee. But some patients complain of pain over the pes anserinus even 1 year after the osteotomy, which may require implant removal for relief. This study aims to define the implant removal rate after MOWHTO due to pain over the pes anserinus. Methods One hundred and three knees of 72 patients who underwent MOWHTO for medial compartment osteoarthritis between 2010 and 2018 were enrolled in the study. Knee injury and osteoarthritis outcome score (KOOS), Oxford knee score (OKS), and visual analogue score (VAS) were assessed for pain in the medial knee joint line (VAS-MJ) preoperatively, 12 months postoperatively, and yearly thereafter; adding VAS for pain over the pes anserinus (VAS-PA). Patients with VAS-PA ≥ 40 and adequate bony consolidation after 12 months were recommended implant removal. Results Thirty-three (45.8%) of the patients were male and 39 (54.2%) were female. The mean age was 49.4 ± 8.0 and the mean body mass index was 27.0 ± 2.9. The Tomofix medial tibial plate-screw system (DePuy Synthes, Raynham, MA, USA) was used in all cases. Three (2.8%) cases with delayed union requiring revision were excluded. The KOOS, OKS, and VAS-MJ significantly improved 12 months after MOWHTO. The mean VAS-PA was 38.3 ± 23.9. Implant removal for pain relief was needed in 65 (63.1%) of the103 knees. The mean VAS-PA decreased to 4.5 ± 5.6 3 months after implant removal (p < 0.0001). Conclusion Over 60% of the patients may need implant removal to relieve pain over the pes anserinus after MOWHTO. Candidates for MOWHTO should be informed about this complication and its solution.


Resumo Objetivo A osteotomia tibial alta com cunha de abertura medial (MOWHTO, do inglês medial open wedge high tibial osteotomy) alivia de forma significativa a dor na linha articular medial em casos de osteoartrite do compartimento medial do joelho. Alguns pacientes, porém, se queixam de dor nos tendões dos músculos sartório, grácil e semitendinoso (pata de ganso) mesmo 1 ano após a osteotomia, o que pode exigir a remoção do implante. Este estudo define a taxa de remoção do implante após a MOWHTO devido à dor nos tendões dos músculos sartório, grácil e semitendinoso. Métodos Cento e três joelhos de 72 pacientes submetidos à MOWHTO para tratamento da osteoartrite do compartimento medial entre 2010 e 2018 foram incluídos no estudo. A pontuação de desfecho de lesão no joelho e osteoartrite (KOOS, do inglês Knee Injury and Osteoarthritis Outcome Score), a pontuação dejoelho de Oxford (OKS, do inglês Oxford Knee Score) e a escala visual analógica (EVA) de dor na linha articular medial do joelho (EVA-MJ) foram avaliados antes da cirurgia. A EVA nos tendões dos músculos sartório, grácil e semitendinoso (EVA-PA) foi adicionada a essas avaliações, também realizadas 12 meses após o procedimento e, a seguir, anualmente. A remoção do implante foi recomendada em pacientes com EVA-PA ≥ 40 e consolidação óssea adequada em 12 meses. Resultados Trinta e três (45,8%) pacientes eram homens e 39 (54,2%), mulheres. A média de idade foi de 49,4 ±8,0, e o índice de massa corpórea (IMC) médio foi de 27,0 ± 2,9. O sistema placa-parafuso tibial medial Tomofix (DePuy Synthes, Raynham, MA, EUA) foi utilizado em todos os casos. Três (2,8%) casos foram excluídos devido ao retardo de consolidação e à necessidade de revisão. Os resultados nas escalas KOOS, OKS e EVA-MJ melhoraram significativamente 12 meses após a MOWHTO. A EVA-PA média foi de 38,3 ± 23,9. A remoção do implante para alívio da dor foi necessária em 65 (63,1%) dos 103 joelhos. Três meses após a remoção do implante, a EVA-PA média diminuiu para 4,5 ± 5,6 (p < 0,0001). Conclusão A remoção do implante pode ser necessária em mais de 60% dos pacientes para alívio da dor nos tendões dos músculos sartório, grácil e semitendinoso após a MOWHTO. Os candidatos à MOWHTO devem ser informados sobre esta complicação e sua resolução.


Sujet(s)
Humains , Ostéotomie , Infection de plaie opératoire , Tibia/chirurgie , Plaques orthopédiques , Transplantation osseuse , Ablation de dispositif
7.
Article de Chinois | WPRIM | ID: wpr-981607

RÉSUMÉ

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Sujet(s)
Mâle , Femelle , Humains , Adulte , Études rétrospectives , Perte sanguine peropératoire , Tibial Plateau Fractures , Résultat thérapeutique , Plaques orthopédiques , Fractures du tibia/chirurgie , Articulation du genou , Ostéosynthèse interne , Ostéotomie , Mise en charge
8.
Article de Chinois | WPRIM | ID: wpr-981653

RÉSUMÉ

OBJECTIVE@#The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.@*METHODS@#Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.@*RESULTS@#In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).@*CONCLUSION@#Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.


Sujet(s)
Humains , Femelle , Sujet âgé , Analyse des éléments finis , Phénomènes biomécaniques , Ostéosynthèse interne/méthodes , Fractures de la hanche/chirurgie , Plaques orthopédiques , Tête du fémur , Fractures du fémur/chirurgie
9.
Article de Chinois | WPRIM | ID: wpr-981688

RÉSUMÉ

OBJECTIVE@#To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.@*METHODS@#Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.@*RESULTS@#Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.@*CONCLUSION@#Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.


Sujet(s)
Mâle , Femelle , Humains , Jeune adulte , Adulte , Adulte d'âge moyen , Sujet âgé , Adolescent , Tibial Plateau Fractures , Plaques orthopédiques , Fractures du tibia/chirurgie , Résultat thérapeutique , Articulation du genou/chirurgie , Ostéosynthèse interne/méthodes , Études rétrospectives
10.
Article de Chinois | WPRIM | ID: wpr-981700

RÉSUMÉ

OBJECTIVE@#To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.@*METHODS@#From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.@*RESULTS@#All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.@*CONCLUSION@#Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.


Sujet(s)
Adulte , Sujet âgé , Animaux , Femelle , Humains , Mâle , Adulte d'âge moyen , Jeune adulte , Plaques orthopédiques , Ostéosynthèse interne/méthodes , Radius/chirurgie , Fractures du radius/chirurgie , Amplitude articulaire , Résultat thérapeutique , Articulation du poignet
11.
Article de Chinois | WPRIM | ID: wpr-981712

RÉSUMÉ

OBJECTIVE@#To compare the clinical efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.@*METHODS@#Fifty-nine patients with metacarpal diaphyseal oblique fractures admitted between January 2018 and September 2021 were selected as the study subjects and divided into the observation group (29 cases) and the control group (30 cases) based on different internal fixation methods. The observation group was treated with Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones, while the control group was treated with micro steel plate internal fixation. Postoperative complications, operation time, incision length, fracture healing time, treatment cost, and metacarpophalangeal function were compared between the two groups.@*RESULTS@#No incision or Kirschner wire infections occurred in the 59 patients, except for one in the observation group. No fixation loosening, rupture, or loss of fracture reduction occurred in any of the patients. The operation time and incision length in the observation group were (20.5±4.2) min and (1.6±0.2) cm, respectively, which were significantly shorter than those in the control group (30.8±5.6) min and (4.3±0.8) cm (P<0.05). The treatment cost and fracture healing time in the observation group were (3 804.5±300.8) yuan and (7.2±1.1) weeks, respectively, which were significantly lower than those in the control group (9 906.9±860.6) yuan and (9.3±1.7) weeks (P<0.05). The excellent and good rate of metacarpophalangeal joint function in the observation group was significantly higher than that in the control group at 1, 2, and 3 months after operation (P<0.05), but there was no significant difference between the two groups at 6 months after operation (P>0.05).@*CONCLUSION@#Micro steel plate internal fixation and Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones are both viable surgical methods for treating metacarpal diaphyseal oblique fractures. However, the latter has the advantages of causing less surgical trauma, shorter operation time, better fracture healing, lower cost of fixation materials, and no need for secondary incision and removal of internal fixation.


Sujet(s)
Humains , Os du métacarpe/traumatismes , Fractures osseuses/chirurgie , Ostéosynthèse interne/méthodes , Fils métalliques , Plaques orthopédiques , Résultat thérapeutique
12.
Article de Chinois | WPRIM | ID: wpr-981734

RÉSUMÉ

OBJECTIVE@#To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.@*METHODS@#From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).@*RESULTS@#All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).@*CONCLUSION@#The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.


Sujet(s)
Mâle , Femelle , Humains , Adolescent , Jeune adulte , Adulte , Adulte d'âge moyen , Tibial Plateau Fractures , Fractures du tibia/chirurgie , Ostéosynthèse interne/méthodes , Résultat thérapeutique , Plaques orthopédiques , Études rétrospectives
13.
Article de Chinois | WPRIM | ID: wpr-981735

RÉSUMÉ

OBJECTIVE@#To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.@*METHODS@#This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.@*RESULTS@#The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.@*CONCLUSION@#Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.


Sujet(s)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Études rétrospectives , Reproductibilité des résultats , Fractures du radius/chirurgie , Ostéosynthèse interne/méthodes , Résultat thérapeutique , Wrist Fractures , Articulation du poignet , Plaques orthopédiques , Amplitude articulaire
14.
Article de Chinois | WPRIM | ID: wpr-981754

RÉSUMÉ

OBJECTIVE@#To summarize the surgical treatment of different proximal clavicle fractures, and discuss the classification of proximal clavicle fractures.@*METHODS@#Total of 24 patients with displaced proximal clavicle fractures were treated from January 2017 to December 2020 including 16 males and 8 females, aged 28 to 66 years old. Among them, 20 cases were fresh fractures and 4 cases were old fractures. According to the Edinburgh classification, 14 cases were type 1B1 fractures and 10 cases were type 1B2 fractures. The different internal fixation methods were selected for internal fixation treatment according to different fracture types.The operation time, blood loss, preoperative and postoperative displacement difference, fracture healing time and Rockwood scoring system were recorded.@*RESULTS@#All patients were followed up for 12 to 24 months. There were no patients with infection or loss of reduction after the operation. Three patients had internal fixation failure after operation, and the internal fixation device was removed. Results The operation time was 30 to 65 min, and the blood loss was 15 to 40 ml. No important nerves, blood vessels, or organs were damaged. The imaging healing time was 3 to 6 months. According to the Rockwood functional score, the total score was (13.50±1.86), pain (2.57±0.50), range of motion (2.78±0.41), muscle strength (2.93±0.28), restricted daily activity (2.85±0.35), subjective results (2.63±0.61);the results were excellent in 20 cases, good in 3 cases, fair in 1 case.@*CONCLUSION@#Proximal clavicular fracture is a type of fracture with low incidence. According to different fracture types, different internal fixation methods and treatment methods can be selected, and satisfactory surgical results can be achieved.


Sujet(s)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Clavicule/chirurgie , Résultat thérapeutique , Plaques orthopédiques , Fractures osseuses/chirurgie , Ostéosynthèse interne/méthodes , Études rétrospectives
15.
Article de Chinois | WPRIM | ID: wpr-981755

RÉSUMÉ

OBJECTIVE@#To compare the clinical efficacy of screw and bone plate internal fixation in the treatment of Lisfranc injury.@*METHODS@#The databases of Wanfang, CNKI, Pubmed, EMBASE, VIP, BIOSIS and other databases were retrieved by computer, and the clinical trial literature from January 1, 2000 to August 1, 2021 was retrieved, the methodological quality of the included studies was strictly evaluated and the data were extracted, and the obtained data were meta-analyzed by Revman 5.4 software.@*RESULTS@#Nine randomized controlled trial literature and 10 retrospective cohort studies were included, of which 416 patients in the experimental group were treated with screw internal fixation, and 435 patients in the control group were treated with bone plate internal fixation. Meta-analysis showed that the surgical time of the bone plate internal fixation group was longer than that of the screw internal fixation group [MD=-14.40, 95%CI(-17.21, -11.60), P<0.000 01], the postoperative X-ray anatomical reduction of the bone plate internal fixation group [MD=0.47, 95%CI(0.25, 0.86), P=0.01], the excellent and good rate of postoperative American orthopedic foot and ankle society(AOFAS) foot function score[MD=0.25, 95%CI(0.15, 0.42), P<0.000 01], postoperative AOFAS foot function score [MD=-5.51, 95%CI(-10.10, -0.92), P=0.02] of the bone plate fixation group was better than those of the screw internal fixation group. Two kinds of operation method had no statistical different for postoperative fracture healing time[MD=1.91, 95%CI(-1.36, 5.18), P=0.25], postoperative visual analgue scale(VAS)[MD=0.38, 95%CI(0.09, 0.86), P=0.11], postoperative complications [MD=1.32, 95%CI(0.73, 2.40), P=0.36], the postoperative infection [MD=0.84, 95%CI(0.48, 1.46), P=0.53], the postoperative fracture internal fixation loosening [MD=1.25, 95% CI(0.61, 2.53), P=0.54], the postoperative incidence of traumatic arthritis [MD=1.80, 95%CI(0.83, 3.91), P=0.14].@*CONCLUSION@#Bone plate fixation has better short-term and medium-term results and lower reoperation rate in the treatment of Lisfranc injury, so it is recommended to use bone plate fixation in the treatment of Lisfranc injury.


Sujet(s)
Humains , Plaques orthopédiques , Études rétrospectives , Fractures osseuses/chirurgie , Ostéosynthèse interne/méthodes , Vis orthopédiques , Résultat thérapeutique , Complications postopératoires
16.
Article de Chinois | WPRIM | ID: wpr-1009193

RÉSUMÉ

OBJECTIVE@#To investigate the effect of intramedullary nail fixation (IMN) and minimally invasive percutaneous plate internal fixation (MIPPO) techniques on tibiofibular fractures and their effect on platelet activation and serum transforming growth factor-β1 (TGF-β1) and bone morphogenetic protein-2 (BMP-2).@*METHODS@#Total of 105 patients with tibiofibular fractures from February 2019 to February 2020 were selected and divided into 53 cases in the MIPPO group and 52 cases in the IMN group. There were 29 males and 24 females with an average age of (41.74±6.05) years old in MIPPO group;in IMN group, 31 males and 21 females with an average age of (40.59±5.26) years old. The perioperative surgical indexes, postoperative complications, ankle function recovery at 12 months postoperatively, platelet activation indexes at 3 and 7 days preoperatively and postoperatively, and serum TGF-β1 and BMP-2 levels at 4 and 8 weeks preoperatively and postoperatively were compared between the two groups.@*RESULTS@#The operating time and fracture healing time in the MIPPO group were shorter than those in the IMN group(P<0.05); Compared with the preoperative period, the levels of GMP-140, PAC-1, CD63, and CD61 increased in both groups at 3 and 7 days after surgery, but were lower in the MIPPO group than in the IMN group(P<0.05);the levels of serum TGF-β1 and BMP-2 increased in both groups at 4 and 8 weeks after surgery compared with the preoperative period, and the postoperative complication rate in the MIPPO group was lower than that in the IMN group(P<0.05);the difference was not statistically significant in the excellent rate of ankle function recovery at 12 months follow-up after surgery between two groups(P>0.05).@*CONCLUSION@#Both intramedullary nail fixation and MIPO technique for treatment of tibia and fibula fractures can improve ankle joint function, but the latter has the advantages of short operation time, fast fracture healing, fewer complications, and light platelet activation. Serum TGF-β1, BMP-2 level improves quickly.


Sujet(s)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Tibia/traumatismes , Facteur de croissance transformant bêta-1 , Ostéosynthese intramedullaire/méthodes , Fractures du tibia/chirurgie , Ostéosynthèse interne/méthodes , Plaques orthopédiques , Consolidation de fracture , Complications postopératoires , Fractures multiples , Résultat thérapeutique , Protéines morphogénétiques osseuses , Interventions chirurgicales mini-invasives/méthodes , Études rétrospectives
17.
Article de Chinois | WPRIM | ID: wpr-1009210

RÉSUMÉ

OBJECTIVE@#To explore clinical effect of attaching locking plate with bone grafting based on retaining the original intramedullary nail in treating non-union after intramedullary nail fixation of long shaft fractures of lower limbs.@*METHODS@#A retrospective study was conducted on 20 patients treated with non-union fractures after intramedullary nailing of long shaft fractures of lower limbs from June 2015 to June 2020. All patients were treated with the original intramedullary nailing and bone grafting from the iliac bone, and were underwent open reduction plate internal fixation and bone grafting for old fractures. Among them, 14 were males and 6 were females, aged from 35 to 56 years old with an average of (42.2±9.6) years old. Nine patients were femoral shaft fracture and 11 patients were tibial shaft fracture. According to characteristics of fracture end nonunion, 6 patients were stable/atrophic, 9 patients were unstable/large, and 5 patients were unstable/atrophic. The nonunion time ranged from 8 to 12 months with an average of(9.8±2.0) months after the initial surgery. Visual analogue scale (VAS), knee range of motion, bone healing time, complications and fracture-end healing were recorded before and at the latest follow-up.@*RESULTS@#All patients were followed up for 18 to 48 months with an average of (36.3±10.5) months. The incision of all patients were healed at stageⅠwithout complications such as infection or internal fixation ruptur. Healing time of femur and tibia was (8.5±2.6) months and (9.5±2.2) months. Knee joint motion increased from preoperative (101.05±8.98) ° to postoperative (139.35±8.78) ° at the latest follow-up (t=-12.845, P<0.001). VAS decreased from preoperative (5.15±1.72) to postoperative (0.75±0.96) at the latest follow-up (t=11.186, P<0.001).@*CONCLUSION@#On the basis of retaining the original intramedullary nail, the addition of locking plate internal fixation and autogenous iliac bone grafting have advantages of simple operation, less trauma, fewer complications and high fracture healing rate. It is one of the effective surgical schemes for the treatment of nonunion after intramedullary nail fixation of long bone fracture of lower extremity.


Sujet(s)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Transplantation osseuse , Études rétrospectives , Plaques orthopédiques , Ostéosynthese intramedullaire/effets indésirables , Fractures du fémur/complications , Membre inférieur , Fractures non consolidées/chirurgie , Consolidation de fracture , Fractures du tibia/complications , Clous orthopédiques , Résultat thérapeutique
18.
Article de Chinois | WPRIM | ID: wpr-1009213

RÉSUMÉ

Hoffa fracture is an unstable intra-articular fracture with significant redisplacement tendency. It is easy to be missed diagnosis when accompanied by distal intercondylar or supracondylar fracture of femur. CT scan is the gold standard for the diagnosis of Hoffa fracture. The treatment principles are anatomic reduction of the articular surface, reliable internal fixation, and early functional activity. At present, the main treatment is arthroscopic screw fixation. During screw fixation, the tail cap of screw should be buried, resulting in non-healing iatrogenic injury of articular cartilage. In the early postoperative functional activity of knee joint, fracture block was repeatedly subjected to backward and upward shear force under the action of the tibial plateau, which is the main reason for the failure of internal fixation. Plate assisted screw fixation could increase local mechanical stability, but it still cannot avoid the defects of iatrogenic cartilage injury. At the same time, plate molding is required during the operation due to the absence of special anatomical plates, resulting in increased surgical trauma and time-consuming surgery. The ideal fixation method for Hoffa fracture should include:(1) Avoid iatrogenic injury of articular surface cartilage. (2) With the rear anti-shear barrier plate function.(3) The internal fixator is closer to the load interface, so as to obtain greater load and better fixed strength.


Sujet(s)
Humains , Hoffa Fracture , Fractures du fémur/chirurgie , Tomodensitométrie , Ostéosynthèse interne/méthodes , Plaques orthopédiques , Maladie iatrogène
19.
Article de Chinois | WPRIM | ID: wpr-970828

RÉSUMÉ

OBJECTIVE@#To explore the clinical outcomes of anteromedial combined with lateral locking plate for complex proximal humeral fractures in the eldery.@*METHODS@#From June 2018 to October 2020, 30 patients who underwent surgical treatment for Neer grade 3 to 4 proximal humeral fractures, including 8 males and 22 females, aged from 51 to 78 years old with an average of (61.5±7.5) years old. Of them, 15 patients had fractures fixed with anteromedial combined with lateral locking plate(ALLP group), whereas 15 received internal fixation with proximal humerus locking plate only(PHLP group). The clinical data, simple shoulder test (SST), humeral head height loss, varus angle and shoulder range of motion were compared between the two groups.@*RESULTS@#All fractures were healed. The follow-up time ranged from 12 to 24 months, with an average of(14.3±2.9) months. The operation time of ALLP group was longer than that of PHLP group (P<0.05). There was no significant difference in intraoperative blood loss between the two groups (P>0.05). There was no significant difference in SST score between the two groups at 1, 3 and 12 months after operation (P>0.05). In terms of radiographic measurement, there was no significant difference in humeral head height loss and varus angle between the two groups at 1 and 3 months after operation (P>0.05). At 12 months after operation, the height loss and varus angle of humeral head in ALLP group were lower than those in PHLP group (P<0.05). In shoulder range of motion, the range of forward elevation in ALLP group was larger than that in PHLP group 1 year after operation(P<0.05). There was no significant difference in external rotation between the two groups.@*CONCLUSION@#Anteromedial combined with lateral locking plate in the treatment of complex proximal humeral fractures in the elderly can increase the stability of the medial column and obtain a good fracture prognosis. But there are also disadvantages such as longer operation time, so it should be individualized according to the fracture type of the patient.


Sujet(s)
Mâle , Femelle , Humains , Sujet âgé , Adulte d'âge moyen , Résultat thérapeutique , Fractures de l'épaule/chirurgie , Ostéosynthèse interne , Épaule , Tête de l'humérus , Plaques orthopédiques , Fractures de l'humérus/chirurgie
20.
Article de Chinois | WPRIM | ID: wpr-970830

RÉSUMÉ

OBJECTIVE@#To evaluate the clinical outcomes of allogeneic femoral head as strut allograft combined with proximal humeral internal locking system (PHILOS) in the treatment of proximal humeral Neer grade Ⅳ fracture with humeral head collapse.@*METHODS@#From January 2018 to November 2020, 18 patients with Neer grade Ⅳ fracture with humeral head collapse were treated with strut allograft with PHILOS, including 4 males and 14 females, aged from 55 to 78 years old, with an average of (68.11±7.20) years old. The operation time, intraoperative bleeding, postoperative drainage volume, fracture healing time, neck-shaft angle and the height of the humeral head, failure of internal fixation the shoulder function at the last follow-up was assessed using Neer's scoring system.@*RESULTS@#All 18 patients were followed up, and the duration ranged from 10 to 12 months, with an average of (11.08±0.65) months. The operation time was (66.44±5.06) min, the intraoperative bleeding volume was (206.67±36.14) ml, the postoperative drainage volume was (76.11±9.63) ml, and the fracture healing time was (17.28±3.92) weeks. At the last follow-up, the degree of loss of neck-shaft angle was (5.44±0.86) ° and the loss of the height of humeral head was (1.43±0.27) mm. All 18 patients had healing without complications such as fracture, withdrawal, penetration of internal fixation and necrosis of humeral head. According to Neer's evaluation standard, the total score was (89.61±5.60), 10 cases got an excellent result, 6 good, 2 fair.@*CONCLUSION@#Allogeneic femoral head combined with PHILOS is an appropriate treatment for the four-part proximal humerus fractures with humeral head collapse, exhibiting good clinic outcome.


Sujet(s)
Mâle , Femelle , Humains , Adulte d'âge moyen , Sujet âgé , Tête de l'humérus , Épaule , Résultat thérapeutique , Plaques orthopédiques , Études rétrospectives , Humérus , Fractures de l'épaule/chirurgie , Ostéosynthèse interne/effets indésirables , Fractures de l'humérus , Allogreffes
SÉLECTION CITATIONS