Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres








Gamme d'année
1.
Article de Chinois | WPRIM | ID: wpr-935813

RÉSUMÉ

Objective: To establish a high performance liquid chromatography method for the determination of 2-thioxothiazolidine-4-carboxylic acid (TTCA) in urine. Methods: After acidification with hydrochloric acid, TTCA in urine was first extracted by ethyl acetate with excessive sodium chloride, then gradient separated by a symmetry C18 column and then detected by a diode array detector. The quantification was based on a working curve of external standard method. Results: The linear relationship of TTCA in urine was good in the range of 0.03-10.00 mg/L, and the correlation coefficient was 0.9999. The detection limit and minimum quantitative concentration of TTCA in urine were 0.008 mg/L and 0.027 mg/L. The intra-assay precision of the method was 0.9%-1.4%, the inter-assay precision was 1.3%-3.5%, and the average recovery was 85.0%-92.7% while the concentrations of TTCA in urine was 0.8, 2.0 and 8.0 mg/L, respectively (n=6) . Conclusion: The gradient elution high performance liquid chromatography method has simple operation and high sensitivity, and it is suitable for the determination of TTCA on a low level in urine for occupational workers exposure to carbon disulfide.


Sujet(s)
Humains , Disulfure de carbone , Chromatographie en phase liquide à haute performance/méthodes , Thiazoles/urine , Thiazolidines , Thiones
2.
Yonsei Medical Journal ; : 265-272, 1999.
Article de Anglais | WPRIM | ID: wpr-150897

RÉSUMÉ

The objectives of this study were to develop optimal analytic methods for detecting urinary 2-thiothiazolidine-4-carboxylic acid (TTCA) and thiocarbamide simultaneously and to evaluate the usefulness of these metabolites to a biological exposure index (BEI) for carbon disulfide (CS2) exposure. For this experiment, synthesized TTCA and thiocarbamide were used. The synthesized TTCA was identified by infrared spectrophotometer, nuclear magnetic resonance spectrometer and thin layer chromatography. The recovery rates of both metabolites were calculated to find the optimum analytical method. The amounts of urinary TTCA and thiocarbamide were measured by using an ultraviolet detector connected to high performance liquid chromatography (HPLC) after the administration of CS2 (350, 700 mg/kg) into Sprague-Dawley rats intraperitoneally. The maximum absorbance wave lengths for TTCA and thiocarbamide were 272 and 236 nm, respectively. Ethyl acetate extraction with NaCl as a salting-out reagent was used as a simultaneous extraction method for these metabolites. HPLC conditions for these metabolites included using a NH2 column, 50 mM KH2PO4: acetonitrile (85:15) and pH 3. Excreted amounts of urinary TTCA and thiocarbamide were increased significantly following CS2 administration. TTCA, which was already adopted as a BEI for CS2 by the American Conference of Governmental Industrial Hygienists (ACGIH), seems to be a more useful BEI for CS2 exposure than thiocarbamide. However further studies are needed to increase analytical efficiency before thiocarbamide can be adopted as a BEI and to apply this analytic method for simultaneous analysis of these metabolites in workers exposed to CS2.


Sujet(s)
Rats , Animaux , Disulfure de carbone/pharmacologie , Exposition environnementale , Rat Sprague-Dawley , Thiazoles/urine , Thiourée/urine , Urée/urine
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE