Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Article Dans Chinois | WPRIM | ID: wpr-1045932

Résumé

There are clear indoor air pollution sources of trichloroethylene and tetrachloroethylene. A large number of epidemiological evidence has confirmed their carcinogenic toxicity and non-carcinogenic toxicity. Several countries and international organizations have paid attention to indoor air trichloroethylene and tetrachloroethylene. It has been also assessed that there should be certain potential health risk of indoor air trichloroethylene and tetrachloroethylene in China. Based on the latest research results of health risk assessment of indoor air trichloroethylene and tetrachloroethylene, the "Standards for indoor air quality (GB/T 18883-2022)" added trichloroethylene and tetrachloroethylene as indicators. The index limit of trichloroethylene is 6 μg/m3 for an 8-hour average concentration. The index limit of tetrachloroethylene is 120 μg/m3 for an 8-hour average concentration. The technical contents related to the determination of the standard limits of trichloroethylene and tetrachloroethylene in indoor air were analyzed and discussed, including the sources, the exposure, the health effects, the determination of the limit values, and the recommendations for standard implementation. It also proposed recommendations for the implementation of"Standards for indoor air quality (GB/T 18883-2022)".


Sujets)
Humains , Tétrachloroéthylène/analyse , Pollution de l'air intérieur , Trichloroéthylène/analyse , Chine
2.
Article Dans Chinois | WPRIM | ID: wpr-985483

Résumé

The usage of vinyl chloride and trichloroethylene in China has been increasing year by year, and they have been detected in both drinking water and environmental water, making them important environmental pollutants. Based on the latest research results on the health effects of vinyl chloride and trichloroethylene, the newly issued, "Standards for Drinking Water Quality (GB5749-2022)" in China has adjusted the standard limit of vinyl chloride from 0.005 mg/L to 0.001 mg/L and the standard limit of trichloroethylene from 0.07 mg/L to 0.02 mg/L. This article analyzed and discussed the relevant technical contents for determining the above standard limits, including the levels and exposure conditions of vinyl chloride and trichloroethylene in the water environment, health effects, derivation of safety reference values, and determination of hygiene standard limits. Suggestions were also made for the implementation of this standard.


Sujets)
Humains , Chloro-éthylène/analyse , Trichloroéthylène/analyse , Eau de boisson , Polluants environnementaux , Chine , Polluants chimiques de l'eau/analyse
3.
Article Dans Chinois | WPRIM | ID: wpr-1046255

Résumé

There are clear indoor air pollution sources of trichloroethylene and tetrachloroethylene. A large number of epidemiological evidence has confirmed their carcinogenic toxicity and non-carcinogenic toxicity. Several countries and international organizations have paid attention to indoor air trichloroethylene and tetrachloroethylene. It has been also assessed that there should be certain potential health risk of indoor air trichloroethylene and tetrachloroethylene in China. Based on the latest research results of health risk assessment of indoor air trichloroethylene and tetrachloroethylene, the "Standards for indoor air quality (GB/T 18883-2022)" added trichloroethylene and tetrachloroethylene as indicators. The index limit of trichloroethylene is 6 μg/m3 for an 8-hour average concentration. The index limit of tetrachloroethylene is 120 μg/m3 for an 8-hour average concentration. The technical contents related to the determination of the standard limits of trichloroethylene and tetrachloroethylene in indoor air were analyzed and discussed, including the sources, the exposure, the health effects, the determination of the limit values, and the recommendations for standard implementation. It also proposed recommendations for the implementation of"Standards for indoor air quality (GB/T 18883-2022)".


Sujets)
Humains , Tétrachloroéthylène/analyse , Pollution de l'air intérieur , Trichloroéthylène/analyse , Chine