Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-879323

RESUMO

OBJECTIVE@#To compare clinical effect of movable external fixation and fusion fixation for the treatment of elbow tuberculosis.@*METHODS@#From October 2013 to June 2019, 52 patients with elbow tuberculosis treated with standard antituberculosis therapy were divided into movable external fixation group and fusion fixation group according to treatment methods. In group A, there were 25 patients, including 11 males and 14 females, aged from 24 to 75 years old with an average of (42.81± 9.01) years old; the courses of diseases ranged from 2 to 9 months with an average of (3.96±1.45) months. In group B, there were 27 patients, including 15 males and 12 females, aged from 23 to 77 years old with an averageof (44.08±7.44) years old; the courses of diseases ranged from 2 to 7 months with an average of (3.88±1.67) months. All patients were performed focus debridement. Intraoperative blood loss, operative time were compared between two groups. VAS score before operation, 2 weeks and 12 months after operation were applied to evaluate pain relieve;Mayo elbow performance score (MEPS) before operation, 1 and 12 months after operation were used to evaluate clinical effect;changes of erythrocyte sedimentation rate (ESR) and Creactive protein, CRP) before operation, 3 weeks after antituberculosis therapy, 1 week and 6 months after operation were compared between two groups.@*RESULTS@#All patients were followed up from 12 to 20 months with an average of (13.50±4.85) months. No mixed infection and recurrence of tuberculosis occurred. There were no statistical differences in intraoperative blood loss and operative time(@*CONCLUSION@#For elbow tuberculosis, movable external fixation and fusion fixation have equal effect in operative time, amount of bleeding and control of tuberculosis infection indicator. Movable external fixation need earlier functional exercise, not conducive to pain relief at early stage, which may be better than fusion fixation, it is worth clinical promoting.


Assuntos
Feminino , Humanos , Lactente , Masculino , Cotovelo , Articulação do Cotovelo/cirurgia , Fixadores Externos , Fixação de Fratura , Resultado do Tratamento , Tuberculose/cirurgia
2.
Artigo em Chinês | WPRIM | ID: wpr-879338

RESUMO

Diabetic foot ulcers (DFUs) is a severe complication of the diabetes mellitus, which is the first leading cause of non-traumatic lower limbs amputations. The pathogenesis of diabetic foot involves a variety of mechanisms, treatment involves the department of foot and ankle surgery, department of vascular surgery, endocrinology, and infection control. Treatment need multidisciplinary diagnosis and treatment. Debridement is the basis of treating diabetic foot ulcers, and the normal anatomical structure should be maintained during the process. Vacuum sealing drainage (VSD) and antibiotic-laden bone cement (ALBC) have more advantages of controlling infection and ulceration wound healing, which could receive good clinical effect. Tendon lengthening could alleviate the problem of ulcer occurrence and progression caused by stress concentration on the bottom of foot, which has widely application and has advantages of preventing formation of foot ulcers. Flap transplantation could solve the problem of wound healing, but it is necessary to consider whether the transplanted flap could bear the same function as plantar tissue. Tibial bone transverse distraction is a relatively new technique, and the mechanism is not clear, but it has certain application prospects from the perspective of clinical efficacy.


Assuntos
Humanos , Desbridamento , Diabetes Mellitus , Pé Diabético/cirurgia , Úlcera do Pé , Terapia de Salvação , Cicatrização
3.
Chinese Journal of Orthopaedics ; (12): 1381-1391, 2019.
Artigo em Chinês | WPRIM | ID: wpr-803253

RESUMO

Objective@#The related literatures on supra acetabular spinal pedicle screws and a subcutaneous connecting rod (INFIX) in recent years was reviewed, and the overall prognosis was analyzed by meta analysis.@*Methods@#literatures were obtained by searching the PubMed, Google Scholar, and Wanfang Full-text Database according to the criteria of inclusion and exclusion. The two members independently screened the qualified literature, evaluated the quality of the literature and extracted the data information. The data information includes demographic and surgical information, main results and secondary results. A large number of data in the selected articles were analyzed and summarized by meta.@*Results@#A total of 20 studies were included, including 567 patients. The clinical results were evaluated by Majeed standard in 6 articles, of which 5 articles described the number of excellent and general prognosis, including 185 patients. The excellent and good prognosis rate was 91% (95%CI: 80%-103%) by meta analysis. The general prognosis rate was 9% (95%CI: 3%-14%). Among the prognostic complications, the incidence of lateral femoral cutaneous nerve damage and heterotopic ossification was higher, and the incidence of other complications was less than 5%. There were 13 articles about the complications of ectopic ossification, of which 1 did not mention the specific number of asymptomatic heterotopic ossification, and the remaining 12 included 424 cases, including 132 cases of ectopic ossification. The incidence of ectopic ossification was 26% (95%CI: 11%-40%). Among the 567 cases, obvious symptoms of lateral femoral cutaneous nerve injury were reported. The patients with lateral femoral cutaneous nerve injury accounted for 25% (95%CI: 17%-32%), and the temporary nerve damage was found in 124 cases. The incidence of temporary agitation after subgroup analysis was 21% (95%CI: 14%-28%). Five articles mentioned the manifestations of postoperative femoral nerve damage, including 10 patients, the incidence of femoral nerve damage was 3% (95%CI: -1%-6%). A total of 18 articles on surgical site-related infections were reported, including 534 patients, of which 15 were infected, with an infection rate of 3% (95%CI: 2%-4%). 19 articles clearly reported the failure of internal fixation after INIFX operation, including 32 patients who needed reoperation for different reasons. The failure of internal fixation was 3% (95%CI: 2%-4%). A total of 585 cases of fracture non-prognosis data were reported, of which 473 cases were cured and 3 cases had bone nonunion. The non-union rate of fracture was 3% (95%CI: 1%-5%).@*Conclusion@#After InFix pelvic surgery, the patient's clinical follow-up prognosis score and imaging findings showed that the postoperative recovery was good, and the new technique also avoided the inconvenience and postoperative complications caused by many traditional pelvic external fixation techniques. However, it was also found that the lateral femoral cutaneous nerve damage and the incidence of heterotopic ossification were also higher.

4.
Artigo em Chinês | WPRIM | ID: wpr-690014

RESUMO

<p><b>OBJECTIVE</b>To explore clinical application of three-dimensional printing technology to design individual angle section on Chevron of hallux valgus osteotomy.</p><p><b>METHODS</b>From May 2013 to May 2016, 47 patients(66 feet) with mild to moderate hallux valgus treated by Chevron osteotomy according to different preoperative design were divided into computer osteotomy group(group A) and traditional osteotomy group(group B). In group A, there were 25 patients (33 feet), including 4 males(5 feet) and 21 females(28 feet) with an average age of (47.88±6.08) years old, average weight IMA was (13.58±1.15) degree, AOFAS score was 59.00±5.86, and treated individual 3D printing technology to design operation scheme. While in group B, there were 22 patients (33 feet), including 3 males (3 feet) and 19 females (28 feet) with an average age of (48.16±6.16) years old, average weight IMA was(13.51±1.14) degree, AOFAS score was 60.67±5.85, and treated with osteotomy according to surgical experience. Operation time, blood loss, hospital stays, VAS score at 1 week after operation, wound healing and improvement of postoperative weight-bearing intermetatarsal angle(IMA) were compared between two groups, AOFAS score system was used to evaluate ankle function after surgery.</p><p><b>RESULTS</b>There was no significant difference in following-up between group A 12.41±2.32 and group B 11.73±2.76. There was 1 patient in group B were excluded. Others perform good wounds healing on the first stage after operation. There were no significant differences in operation time, blood loss, hospital stays and VAS score at 1 week after operation(<0.05); IMA in group A was (5.21±0.88)°, (6.42±0.85)° in group B, and had significant differences between two groups (=5.68, <0.05). There was obvious meaning in AOFAS score between group A 88.15±5.19 and group B 82.90±5.01(=4.14, <0.05). Fourteen feet in group A obtained excellent results and 19 feet good, while 5 feet in group B obtained excellent results and 27 feet good.</p><p><b>CONCLUSIONS</b>Compared with traditional osteotomy group, three-dimensional printing technology to design individual angle section on Chevron of hallux valgus osteotomy could better correct IMA, improve postoperative foot function, and it is a kind of individualized and digital method to design operation.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hallux Valgus , Cirurgia Geral , Ossos do Metatarso , Cirurgia Geral , Osteotomia , Impressão Tridimensional , Radiografia , Resultado do Tratamento
5.
Artigo em Chinês | WPRIM | ID: wpr-281334

RESUMO

<p><b>OBJECTIVE</b>To discuss the suitable surgical approach and the internal fixation of unstable pelvic pelvic fractures.</p><p><b>METHODS</b>From May 2010 to May 2015, 45 patients with unstable pelvic fractures were treated with different approaches and fixations, including 38 males and 7 females with an average age of 45 years ranging from 21 to 61 years. The course was within 2 weeks. According to Young-Burg classification, 23 patients were lateral compression injuries, 6 patients were vertical shearing injuries, 16 patients were anterior-posterior compression injuries. All patients had hip pain and limitation of motion, the X-rays showed the pelvic ring fracture.</p><p><b>RESULTS</b>All wounds healed well without complications, 45 cases were followed up for a mean period of 13 months (ranged 9 to 21 months). Patients with hip pain had a good postoperative pain relief. The post-operative X-rays showed the reduction was satisfied and the pelvic ring shaped well. According to Majeed standards, the final follow-up score was 93.5±11.6, 35 cases got excellent results, 8 were good, 2 were fare.</p><p><b>CONCLUSIONS</b>The unstable pelvic and acetabular fractures are always with compound injury. Beside the reduction, to decrease the second surgery trauma should take into consideration as well, the intra-articular reduction and the stability of the pelvic were especially valued, so combined the different approach with minimal invasive technique can get good clinical result.</p>

6.
Zhongguo Zhong Yao Za Zhi ; (24): 382-389, 2015.
Artigo em Chinês | WPRIM | ID: wpr-305290

RESUMO

Vitexin, a naturally occurring flavone glycoside in plants, has many pharmacological effects, which is widely distributed in nature. This paper reviewed the research progress of the distribution of vitexin in the plant resources and its pharmacological effects, and summarized its application prospects, aiming to provide a useful reference for the development of vitexin-enriched plant resources.


Assuntos
Animais , Humanos , Antineoplásicos , Farmacologia , Antioxidantes , Farmacologia , Apigenina , Farmacologia , Hipoglicemiantes , Farmacologia , Infarto do Miocárdio , Tratamento Farmacológico , Dispersão Vegetal
7.
Zhongcaoyao ; Zhongcaoyao;(24): 1454-1459, 2015.
Artigo em Chinês | WPRIM | ID: wpr-854388

RESUMO

Objective: Processing technology and antioxidant activity in vivo of pomegranate superfine powder were investigated. Methods: Processing technology of superfine powder of Granati Pericarpium was optimized using single-factor tests and response surface methodology (RSM). The antioxidant effect in vivo of superfine powder of Granati Pericarpium with different particle, vitamin E, and normal saline were studied. Results: The optimally grinding conditions for Granati Pericarpium were grinding time of 25 min, grinding temperature of -17℃, and input quantity of 198 g. Under the optimally grinding conditions, the minimum particle size of superfine powder of Granati Pericarpium was 7.68 μm which was close to the predicted value of 7.96 μm. Therefore, the established regression model has good prediction capability. Experimental results show that the superfine powder and vitamin E groups compared with the coarse powder and blank groups could significantly improve the activity of SOD, CAT, and GSH-Px, and reduce the content of MDA in serum of mice. Conclusion: The ability of superfine powder group on the protection of membrane lipid peroxidation and scavenge free radical is quite superior. It indicates that the active ingredients in the superfine powder of Granati Pericarpium could be dissolved better and more quickly in solvent than those in coarse powder. Therefore, the superfine powder of Granati Pericarpium has the better anti-oxidant effect in vivo.

8.
Artigo em Chinês | WPRIM | ID: wpr-301809

RESUMO

<p><b>OBJECTIVE</b>To evaluate the feasibility and efficacy of unilateral pedicle screw fixation in treating thoracolumbar fractures through paraspinal approach.</p><p><b>METHODS</b>From January 2006 to January 2009,21 patients with single level thoracolumbar fracture without neurological symptoms were treated with unilateral pedicle screw fixation through paraspinal approach. There were 14 males and 7 females,aged from 21 to 65 years old with a mean of 36.4 years. The duration from injury to operation ranged from 6 h to 5 d with an average of 3 d. According to the classification of Denis fracture, compression fractures happedned in 12 cases and burst fractures happened in 9 cases,including 1 case with T5 fracture, 2 cases with T7 fracture, 2 cases with T10 fracture, 3 cases with T11 fracture, 8 cases with T12 fracture, and 5 cases with L1 fracture. Based on the Flankel grade, all patients were classified as grade E. Anterior vertebral body height ratio, sagittal Cobb angle, condition of internal fixation failure, visual analogue score (VAS) were evaluated.</p><p><b>RESULTS</b>All patients were followed up from 12 to 36 months with an average of 20.5 months. No internal fixation failure was found. Anterior vertebral body height ratios at preoperative 3 days after operation and last follow-up were 54.3 +/- 2.8, 92.9 +/- 1.5, 93.8 +/- 1.7, respectively;sagittal Cobb angle at the three timepoints were (27.8 +/- 2.5) degrees, (5.3 +/- 0.8) degrees, (6.3 +/- 1.4) degrees, respectively; the difference was statistical significant (P < 0.05). VAS was (1.2 +/- 0.4) points at last follow-up and had obviously improved (P < 0.05).</p><p><b>CONCLUSION</b>Treatment of thoracolumbar fractures with unilateral pedicle screw fixation through paraspinal approach is safe with the advantages of micro-trauma and less blood loss,which can not only completely retain the posterior spinal complex structure, reinforce the spinal stability, raise the reductional quality, but also improve the strength of fixation and the distribution of stress force.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Parafusos Ósseos , Estudos de Viabilidade , Fixação Interna de Fraturas , Métodos , Fraturas da Coluna Vertebral , Diagnóstico por Imagem , Cirurgia Geral , Vértebras Torácicas , Diagnóstico por Imagem , Ferimentos e Lesões , Cirurgia Geral , Tomografia Computadorizada por Raios X
9.
Artigo em Chinês | WPRIM | ID: wpr-448466

RESUMO

A total of 33 non-neurological symptoms patients with thoracolumbar fractures underwent unilateral pedicle screw fixation plus short segment pedicle screw through para-vertebral muscles. Preoperative computed tomography ( CT) scan showed one side pedicle was complete.The average follow-up period was 22 (12-40) months.There was no internal fixation failure.The posterior paraspinal approach for unstable thoracolumbar fractures , retaining posterior ligament complex and fixation by unilateral pedicle screw fixation through the pedicle of fractured vertebra , is both safe and effective for thoracolumbar fractures.

10.
Artigo em Inglês | WPRIM | ID: wpr-812199

RESUMO

AIM@#To establish a method to simultaneously determine the main five alkaloids of Catharanthus roseus for trace samples, a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) analysis method was developed.@*METHOD@#The five Catharanthus alkaloids, vinblastine, vincristine, vinleurosine, vindoline, and catharanthine were chromatographically separated on a C18 HPLC column. The mobile phase was methanol-15 nmol·L(-1) ammonium acetate containing 0.02% formic acid (65 : 35, V/V). The quantification of these alkaloids was based on the Multiple Reaction Monitoring (MRM) mode.@*RESULTS@#This method was validated, and the results achieved the aims of the study. The intra- and inter-day precision and accuracy of the five alkaloids were within 1.2%-11.5% (RSD%) and -10.9%-10.5% (RE%). The recovery rates of the five alkaloids of samples were from 79.9% to 91.5%. The five analytes were stable at room temperature for 2 h, at 4 °C for 12 h, and at -20 °C for two weeks. The developed method was applied successfully to determine the content of the five alkaloids in three plant parts of three batches of C. roseus with a minute amount collected from three regions of China.@*CONCLUSION@#The HPLC-ESI-MS/MS method can be used for the simultaneous determination of five important alkaloids in trace C. roseus samples.


Assuntos
Alcaloides , Química , Catharanthus , Química , China , Cromatografia Líquida de Alta Pressão , Métodos , Medicamentos de Ervas Chinesas , Química , Espectrometria de Massas em Tandem , Métodos
11.
Artigo em Chinês | WPRIM | ID: wpr-250724

RESUMO

<p><b>OBJECTIVE</b>To compare different surgical approaches in order to obtain better surgical exposure and more reliable reset fixation according to the different types of quadrilateral area fractures of acetabular.</p><p><b>METHODS</b>From January 2006 to January 2011, 58 patients with the quadrilateral area fractures of acetabular were treated by surgical operation through the simple Kocher-Langenbeck (KL) approach, ilioinguinal approach, modified Stoppa approach, or combined surgical approach, or a combination of anterior column screw fixation percutaneously and modify Stoppa approach.</p><p><b>RESULTS</b>Forty-nine patients were followed up for an average time of 32 months ranging from 2 to 6 years. One patient with deep infection cured after treatment of effective antibiotics and drainage, 2 patients had a sciatic nerve injury, 2 cases of avascular necrosis of the femoral head. Among them, 36 cases were anatomical reducted, 8 were good and 5 were poor according to Matta's radiographic assessment system. According to the mean Merle d'Aubigne and Postel Score,32 patients got excellent result, 12 good,4 fair and 1 bad,the average score was (15.3 +/- 2.5).</p><p><b>CONCLUSION</b>Single classic surgical approach can only use for some types of the complex quadrilateral area fractures of acetabular while combination approach may need for some fractures. Modified Stoppa approach combined with ilioinguinal approach or a combination of anterior column acetabular screw fixation are the most effective surgical approaches for complex quadrilateral area fractures of acetabular.</p>


Assuntos
Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Acetábulo , Ferimentos e Lesões , Cirurgia Geral , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas , Cirurgia Geral
12.
Artigo em Chinês | WPRIM | ID: wpr-313822

RESUMO

<p><b>OBJECTIVE</b>To investigate the clinical usage of percutanious retrograde acetabular anterior horn screw fixation.</p><p><b>METHODS</b>From June 2006 to November 2011,27 patients with anterior horn accetabular fractures were treated with percutaneous retrograde screw. There were 20 males and 7 females with an average age of 35 years (ranged,20 to 61). According to Tile classification,type A was in 5 cases,type B was in 18 cases and type C was in 4 cases. The intra-operative blood loss volume, fractured reduction and screw location were observed.</p><p><b>RESULTS</b>Postoperative X-ray and CT scan showed good reduction. According to the standard of Matta, 10 cases got excellent results, 15 good and 2 poor. All fractures healed and no complications such as neurovascular injuries and femoral head necrosis were found.</p><p><b>CONCLUSION</b>Percutanious retrograde acetabular anterior horn screw technique have advantages of little trauma, less blood loss volume, reliable fixation, which can be effectively used in clinic.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acetábulo , Diagnóstico por Imagem , Ferimentos e Lesões , Cirurgia Geral , Parafusos Ósseos , Fixação Interna de Fraturas , Métodos , Fraturas Ósseas , Diagnóstico por Imagem , Cirurgia Geral , Radiografia
13.
Artigo em Chinês | WPRIM | ID: wpr-297835

RESUMO

Finite element analysis (FEA) is broadly used in engineering, it was initially applied to simulate and solve a variety of engineering mechanics, thermal, electromagnetics, and other physical problems. The principle is a collective to be composed by an infinite number of particles, and an unlimited number of degrees of freedom from the continuum approximation. Brekelmas and Ryblcki firstly applied the finite element method to orthopedic biomechanics research in 1972. The first cervical vertebra finite element model was established in 1982 by Hosey. With the computer and software technology advances in the past 20 years, finite element method in cervical spine biomechanics studies is increased and widespread.


Assuntos
Humanos , Fenômenos Biomecânicos , Vértebras Cervicais , Fisiologia , Análise de Elementos Finitos , Modelos Anatômicos , Modelos Biológicos , Movimento
14.
Artigo em Chinês | WPRIM | ID: wpr-332832

RESUMO

<p><b>OBJECTIVE</b>To investigate the damage characteristics and biomechanical mechanisms of the thoracolumbar vertebral bursh fracture during the impact loading.</p><p><b>METHODS</b>From September 2008 to October 2009, 10 fresh human thoracolumbar spine specimens were collected for experimental model and divided into two groups. Biomechanical static and dynamic impact strength test were performed respectively in two groups. The static and dynamic data from thoracolumbar vertebrae shock response in different loads were observated.</p><p><b>RESULTS</b>Thoracolumbar yield load was (5 280.00 +/- 354.2) N, yield displacement was (13.32 +/- 2.07) mm, the limit load was(6 590.00 +/- 249.20) N, ultimate displacement was (20.60 +/- 2.57) mm, load speed was 0.02 g, and the average limit load of dynamic mechanical properties of thoracic and lumbar vertebrae was (14 425.60 +/- 1101.52) N, the average reaction time load was (17.29 +/- 2.04) ms, the average of acceleration was (36.80 +/- 2.81) g, the dynamic displacement was (45.11 +/- 1.13) mm.</p><p><b>CONCLUSION</b>Thoracolumbar vertebral burst fracture is a serious injury caused by the release of high-energy moment, the role of biomechanical forces are in a pattern of pulse change, thoracic and lumbar vertebrae present with the viscoelastic properties of biological materials.</p>


Assuntos
Humanos , Fenômenos Biomecânicos , Cadáver , Vértebras Lombares , Ferimentos e Lesões , Fraturas da Coluna Vertebral , Metabolismo , Estresse Mecânico , Vértebras Torácicas , Ferimentos e Lesões
15.
Acta Anatomica Sinica ; (6): 153-156, 2010.
Artigo em Chinês | WPRIM | ID: wpr-401819

RESUMO

Objective To investigate a special optimization technique for computer aided measure, and provide anatomical basis for screw internal fixation in the cavitas glenoidalis through the coracoid process of scapula. Methods Thirty accurate scapula models were reconstructed from CT data sets. First, special optimization objective function was designed for single screw internal fixation configuration, and the optimal placement of screw was found automatically under constraints. Then, the placements of double screws internal fixation configuration were searched taking advantage of principal component analysis. Finally, statistical measure data were provided according to new anatomical reference landmarks for clinical use. Results For single screw internal fixation configuration, the distance from the optimal screw entry point P to the acromion process point X was (39.15±2.28) mm, to the coracoid process point Y was (28.66±2.68) mm, to the angulus superior point Z was (61.13±6.57) mm;The angle was (81.27±7.15)° between PX and PY, and (133.27±6.84)° between PX and PZ. The mean inclination of the lag screw was (104.08±4.41)° for the angle with line PX, (101.29±3.51)° with line PY, and (76.23±5.03)° with line PZ. For double screws configuration, the distance from the original single screw entry point P to the screw entry point E was (5.12±1.37)mm,to the screw entry point F was (3.88±0.94)mm. The angle between the long axis of coracoid process and line EF was (27.41±3.51)°. Conclusion The automatic optimization technique for computer aided measure is very efficient and has many advantages over the conventional manual dissection methods, and is convenient to design new anatomical reference landmark system for clinical use.

16.
Yao Xue Xue Bao ; (12): 525-531, 2009.
Artigo em Chinês | WPRIM | ID: wpr-278226

RESUMO

To study the preparation, activity and targeting ability evaluation in vitro on epigallocatechin-3-gallate (EGCG) bovine serum albumin nanoparticles targeting to PC-3 cells, the folate mediated EGCG bovine serum albumin nanoparticles (FA-EGCG-BSANP) were prepared by desolvation process. The morphology and particle size of the nanoparticles were determined by atomic force microscope (AFM). HPLC was used to analyse the entrapment efficiency and drug loading rate of EGCG The amount of folate conjugation on the BSANP was determined by quantitative ultraviolet (UV) spectrophotometer analysis. The targeting ability to PC-3 was observed using laser scanning confocal microscope (LSCM) and fluorophotometer microscope. And the activity of FA-EGCG-BSANP was mensurated by MTT method. The morphology and particle size distribution of FA-EGCG-BSANP were uniform and even with the mean particle size of 200 nm. The entrapment efficiency and loading rate of EGCG were (81.5 +/- 1.8) % and (29.3 +/- 0.6) %, respectively, and the amount of folate conjugation was 18.363 microg x mg(-1) BSA. The FA-EGCG-BSANP uptakes by cultured PC-3 cells were 23.65 times the amount of EGCG-BSANP in a concentration dependant manner. The lethality of PC-3 cells treated with FA-EGCG-BSA was 82.8%, while those treated with EGCG and EGCG-BSANP were 58.6% and 55.1%, respectively. And lethality of PC-3 cells was positively correlated with the nanoparticles uptake amount. FA-EGCG-BSANP can significantly promote EGCG to PC-3 cells sites and improve their efficacy, which is considered to an experimental foundation for further research on its activity, targeting ability and metabolism in vivo.


Assuntos
Humanos , Masculino , Antineoplásicos Fitogênicos , Farmacocinética , Farmacologia , Catequina , Farmacocinética , Farmacologia , Morte Celular , Linhagem Celular Tumoral , Portadores de Fármacos , Composição de Medicamentos , Sistemas de Liberação de Medicamentos , Métodos , Ácido Fólico , Química , Farmacocinética , Nanopartículas , Tamanho da Partícula , Neoplasias da Próstata , Metabolismo , Patologia , Soroalbumina Bovina , Química , Farmacocinética , Farmacologia
17.
Zhongguo Zhong Yao Za Zhi ; (24): 2486-2489, 2008.
Artigo em Chinês | WPRIM | ID: wpr-283857

RESUMO

To investigate the technological parameters of the isolation and purification of 10-hydroxycamptothecin and vincoside-lactam from Camptotheca acuminata seed by polyamide. The static arid dynamic adsorption characteristics of 10-hydroxycamptothecin and vincoside-lactam on polyamide were studied, and the contents were determined by HPLC. The optimum parameters for adsorption were as follows: the contents of 10-hydroxycamptothecin and vincoside-lactam in the extracts were 0.189 g x L(-1) and 0.334 g x L(-1), respectively, pH 6, flow rate was 1.0 mL x min(-1), processing volume was 3 BV; for desorption: ethanol-water (60:40), flow rate was 1.0 mL x min(-1), 5 BV as an eluent. After treated with polyamide, the contents of 10-hydroxycamptothecin and vincoside-lactam were 17.52% and 32.87%, respectively, the recovery yields were 66.05% and 75.86%, respectively. Results showed that polyamide revealed a good ability to separate 10-hydroxycamptothecin and vincoside-lactam. Therefore, we concluded that results in this study may provide scientific references for the large-scale production of 10-hydroxycamptothecin and vincoside-lactam extracted from C. acuminata seed.


Assuntos
Camptotheca , Química , Camptotecina , Química , Cromatografia Líquida de Alta Pressão , Medicamentos de Ervas Chinesas , Química , Concentração de Íons de Hidrogênio , Nylons , Química , Sementes , Química
18.
Artigo em Chinês | WPRIM | ID: wpr-323157

RESUMO

The periprosthetic osteolysis is one of the complications of artificial joint replacement. The function and the stability of the hip joint will be severely affected once the periprosthetic osteolysis occurred postoperatively,so it's necessary to fully recognize the mechanism of the osteolysis. There is no globally accepted diagnostic standard of this disease, and then, the grading of the postoperative hip joint function is indispensable. The using of diphosphonate to prevent the osteolysis has positive significance, but it is not broadly used in clinical. Taking the periprosthetic osteolysis of hip arthroplasty as the central, this article shows a briefly overview of this subject.


Assuntos
Humanos , Artroplastia de Quadril , Osteólise , Diagnóstico , Tratamento Farmacológico , Complicações Pós-Operatórias , Diagnóstico , Tratamento Farmacológico
19.
Artigo em Chinês | WPRIM | ID: wpr-263728

RESUMO

<p><b>OBJECTIVE</b>To evaluate the therapeutic effects of three different intervertebral fusion with bone graft and internal fixation in the treatment of cervical spondylotic myelopathy.</p><p><b>METHODS</b>In the retrospective study, 83 patients (38 males and 45 females, with an average age of 69 years) with cervical spondylotic myelopathy were divided into three groups. The patients in three groups were treated by autogenous iliac bone grafting (Robingson grafting) with anterior cervical plate-screw fixation, Pyramesh with anterior cervical plate-screw fixation and BAK fixation respectively. JOA scores and the bony fusion time were recorded and the results were evaluated by numeric computer system.</p><p><b>RESULTS</b>The JOA scores of all the patients were higher than those before surgery (t = 1.55, P < 0.05). There were no statistical difference of JOA scores in the three groups (F = 2.51, P > 0.05).</p><p><b>CONCLUSION</b>It is concluded that internal fixation of the three types is promising to the treatment of cervical spondlotic myelopathy. Robingson grafting with anterior cervical plate-screw fixation provides good stability and bony fusion. BAK is better technically required but there was height loss in clinic. Pyramesh with anterior cervical plate-screw fixation combines the merits of both two techniques above but the cost is higher.</p>


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Ósseo , Vértebras Cervicais , Cirurgia Geral , Fixação Interna de Fraturas , Métodos , Fusão Vertebral , Métodos , Espondilose , Cirurgia Geral
20.
Artigo em Chinês | WPRIM | ID: wpr-263764

RESUMO

<p><b>OBJECTIVE</b>To evaluate the biomechanical personality of the sacroiliac anatomy type Bar-plate system (SABP), which was of fixation usage to the fracture or dislocation of the sacroliliac joint.</p><p><b>METHODS</b>Twenty fresh and freeze cadaver pelvises were prepared with pelvic fracture model,compared with different internal fixation systems such as Galveston technique, transiliac rod fixation, reconstruction plate and sacroiliac joint screws using experimental stress analysis methods,and then the stability of the pelvic was obtained and evaluated.</p><p><b>RESULTS</b>Using new SABP system to treat pelvic sacroiliac joint fracture and dislocation was higher 10%, 11%, 16%, 21% in the strength; more 12%, 14%, 21%, 31% in rigidity; less 13%, 14%, 22%, 25% in straining;less 10%, 12%, 16%, 20% in shifting than the Galveston technique, transiliac rod fixation, reconstruction plate and sacroiliac joint screws, with remarkable statistic difference (P < 0.05), and it was even better than cadaver pelvis.</p><p><b>CONCLUSION</b>To treat pelvic facture, the fixation with new SABP system is of better strength, rigidity and stability, and the SABP system is an ideal new application.</p>


Assuntos
Adulto , Humanos , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Placas Ósseas , Fraturas Ósseas , Cirurgia Geral , Fixadores Internos , Luxações Articulares , Cirurgia Geral , Articulação Sacroilíaca , Ferimentos e Lesões , Cirurgia Geral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA