RESUMO
Objective: To determine the feasibility of using temporary permanent pacemaker (TPPM) in patients with high-degree atrioventricular block (AVB) after transcatheter aortic valve replacement (TAVR) as bridging strategy to reduce avoidable permanent pacemaker implantation. Methods: This is a prospective observational study. Consecutive patients undergoing TAVR at Beijing Anzhen Hospital and the First Affiliated Hospital of Zhengzhou University from August 2021 to February 2022 were screened. Patients with high-degree AVB and TPPM were included. Patients were followed up for 4 weeks with pacemaker interrogation at every week. The endpoint was the success rate of TPPM removal and free from permanent pacemaker at 1 month after TPPM. The criteria of removing TPPM was no indication of permanent pacing and no pacing signal in 12 lead electrocardiogram (EGG) and 24 hours dynamic EGG, meanwhile the last pacemaker interrogation indicated that ventricular pacing rate was 0. Routinely follow-up ECG was extended to 6 months after removal of TPPM. Results: Ten patients met the inclusion criteria for TPPM, aged (77.0±11.1) years, wirh 7 females. There were 7 patients with third-degree AVB, 1 patient with second-degree AVB, 2 patients with first degree AVB with PR interval>240 ms and LBBB with QRS duration>150 ms. TPPM were applied on the 10 patients for (35±7) days. Among 8 patients with high-degree AVB, 3 recovered to sinus rhythm, and 3 recovered to sinus rhythm with bundle branch block. The other 2 patients with persistent third-degree AVB received permanent pacemaker implantation. For the 2 patients with first-degree AVB and LBBB, PR interval shortened to within 200 ms. TPPM was successfully removed in 8 patients (8/10) at 1 month without permanent pacemaker implantation, of which 2 patients recovered within 24 hours after TAVR and 6 patients recovered 24 hours later after TAVR. No aggravation of conduction block or permanent pacemaker indication were observed in 8 patients during follow-up at 6 months. No procedure-related adverse events occurred in all patients. Conclusion: TPPM is reliable and safe to provide certain buffer time to distinguish whether a permanent pacemaker is necessary in patients with high-degree conduction block after TAVR.
Assuntos
Feminino , Humanos , Bloqueio Atrioventricular/terapia , Estudos de Viabilidade , Substituição da Valva Aórtica Transcateter , Marca-Passo Artificial , Bloqueio de RamoRESUMO
Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter , Estudos Retrospectivos , Artérias , Aorta , Estenose da Valva Aórtica/cirurgiaRESUMO
Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter , Estudos Retrospectivos , Artérias , Aorta , Estenose da Valva Aórtica/cirurgiaRESUMO
Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.
Assuntos
Humanos , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
Objectives: To explore the efficacy and safety of emergency transcatheter aortic valve replacement (TAVR). Methods: Data of patients who underwent emergency TAVR in eight centers, namely Fuwai Hospital, Wuhan Asia Heart Hospital, Xijing Hospital, Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Guangdong Provincial People's Hospital, Zhongshan Hospital Affiliated to Fudan University, the First Affiliated Hospital of Zhengzhou University, the Second Xiangya Hospital of Central South University, between May 2017 and December 2020 were retrospectively analyzed. The use of mechanical circulatory support system (MCS) and the results of laboratory tests (N-terminal B-type natriuretic peptide (NT-proBNP)) and echocardiography (mean aortic valve cross valve pressure difference and left ventricular ejection fraction) before and after operation were collected. The primary endpoint was all-cause death, and the secondary endpoints were stroke, major bleeding, major vascular complications, myocardial infarction, permanent pacemaker implantation, and acute renal injury. Device success was caculated, which refered to absence of procedural mortality and correct positioning of a single prosthetic heart valve into the proper anatomical location and intended performance of the prosthetic heart valve (mean aortic valve gradient<20 mmHg(1 mmHg=0.133 kPa) or peak velocity<3 m/s, with no moderate or severe prosthetic valve regurgitation). Kaplan-Meier survival curve was used to estimate the survival rate of patients during follow-up. Results: This study included 48 patients. The age was (72.5±8.1) years, and 34 patients were males (70.8%). Device success rate was 91.7% (44/48). The mean aortic valve transvalvular pressure was significantly decreased after operation ((12.3±6.4)mmHg vs. (60.2±23.8)mmHg, P<0.000 1). Left ventricular ejection fraction was significantly increased ((41.5±11.7)% vs. (31.0±11.3)%, P<0.000 1). NT-proBNP significantly decreased (3 492.0 (1 638.8, 7 165.5) ng/L vs. 12 418.5 (6 693.8, 35 000.0) ng/L, P<0.000 1). In-hospital all-cause mortality was 8.3% (4/48). During hospitalization, the rate of stroke was 2.1% (1/48), major bleeding was 6.3% (3/48), major vascular complications was 10.4% (5/48), myocardial infarction was 4.2% (2/48), permanent pacemaker implantation was 6.3% (3/48), and the rate of acute renal injury was 12.5% (6/48). MCS was used in 20 patients (41.7%). The median follow-up time was 196 days. During the follow-up, one patient died (due to systemic metastasis of pancreatic cancer), two cases suffered new myocardial infarction and one case received permanent pacemaker implantation. The survival rate of 30 days, 1 year and 2 years after the operation were 91.7% (44/48), 89.6% (43/48), 89.6% (43/48), respectively. Conclusion: Emergency TAVR may be a safe and effective treatment for patients with severe decompensated aortic valve stenosis.
Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Injúria Renal Aguda , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Infarto do Miocárdio/cirurgia , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral , Volume Sistólico , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.
Assuntos
Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Fluoroscopia , Estudos Retrospectivos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
Objective: To explore the feasibility of the single-stage stent implantation following rotational atherectomy combined with transcatheter aortic valve replacement (TAVR) in treating patients with severe aortic stenosis(AS) and severe calcified coronary artery stenosis. Methods: Three patients who received single-stage stent implantation following rotational atherectomy combined with TAVR in Fuwai hospital from April to October 2019 were included in this retrospective analysis. Clinical and anatomical features (including echocardiography and aortic CT) of the patients were collected, efficacy and safety of this operation strategy were observed and 6 months follow up results were summarized. Results: Three patients (2 females, 66-80 years old) were included. The mean Society of Thoracic Surgeons (STS) risk score was 7.8%. The mean maximum velocity of aortic valve was 4.4 m/s, the mean transvalvular pressure gradient was 53.2 mmHg (1 mmHg=0.133 kPa), mean left ventricular ejection fraction (LVEF) was 48.6%. All three patients had severe calcified coronary artery stenosis: left anterior descending artery (LAD, n=2) and left main coronary artery (LM, n=1), requiring rotary grinding. The mean SYNTAX score was 20. All the procedures were performed through transfemoral access. After aortic valve crossing, all coronary lesions were successfully treated with stent implantation following rotational atherectomy, transfemoral TAVR was then immediately performed with a self-expandable Venus-A valve. One patient underwent"valve-in-valve"implantation due to the high-implantation position of the first valve. The procedures were completed without complications in all the three patients. The immediate effect was satisfactory. Echocardiography results showed that the mean maximum velocity of aortic valve was 2.1 m/s, mean gradient was 9.3 mmHg, and mean LVEF was 59% after the procedure. There was no death and revascularization during the 6 months follow-up. Conclusion: In patients with severe calcified coronary artery and severe AS with high risk of cardiac surgery, the single-stage stent implantation following rotational atherectomy combined with TAVR is feasible and results are satisfactory in this patient cohort.
RESUMO
Objective: To investigate the safety and efficacy of left ventricular guidewire pacing during transcatheter aortic valve replacement (TAVR). Methods: This is a retrospective study. Thirteen patients, who underwent TAVR with left ventricular guidewire pacing from October 2019 to December 2019 in Fuwai Hospital, were included. Clinical data and operational procedure data of the patients were collected. Changes in blood pressure and electrocardiogram were observed during operations. Ascending aorta angiography was performed to evaluate the regurgitation of aortic valve after valve implantion. The incidence of major adverse cardiac events during hospitalization and at 3-months after discharge was recorded. Results: There were 7 male and 6 female patients in this cohort,and age was (73.8±8.3) years old. Among the 13 patients, 9 were tricuspid aortic valves, 3 were bicuspid aortic valves, and 1 was degenerated bioprosthetic surgical aortic valve. TAVR were successfully performed in all of the 13 cases using pacing through the left ventricular guidewire. During balloon dilation, the blood pressure decreased to below 60 mmHg (1 mmHg=0.133 kPa) after 180 beats/min pacing, and the valve release process was smooth and the position was stable. The results of aortography showed that there was no regurgitation in 7 cases, mild regurgitation in 5 cases and moderate regurgitation in 1 case. Three patients required temporary pacing during the procedure due to complete heart block, among whom 1 patient was implanted with permanent pacemaker during hospitalization, and the other 2 patients recovered within 24 hours after operation. In another case, there was no significant change of electrocardiogram during the operation, and complete heart block occurred 10 days after the operation, and treated with permanent pacemaker. The other 10 patients began to carry out bedside activities and rehabilitation training 24 hours after operation. There was no death, myocardial infarction, stroke and other major adverse cardiac events during hospitalization and at 3-month follow-up after discharge. Conclusion: Left ventricular guidewire pacing is a safe and effective strategy for TAVR.
Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter , Resultado do TratamentoRESUMO
OBJECTIVE@#To explore the effectiveness of Danhong Injection () on improving microcirculatory injury after percutaneous coronary intervention (PCI) in patients with coronary heart disease (CHD).@*METHODS@#A randomized controlled trial was conducted and 90 patients were enrolled. A random sequence was generated using statistical analysis software. Patients with microcirculatory injuries after PCI were randomly divided into 3 groups for treatment (30 subjects in each group): Danhong Injection group: after PCI, Danghong Injections were given with intravenous administration with 40 mL twice a day for a week; statins intensive group: after PCI, atorvastatin calcium tablets were given oral medication with 80 mg once, and then atorvastatin 40 mg daily for 1 week; the control group: after PCI, atorvastatin calcium tablets were given oral medication with 10-20 mg daily for 1 week. The index of microcirculation resistance (IMR) was used to assess microcirculatory injury during PCI. The IMR of the target vessel was reexamined after 1 week of drug treatment.@*RESULTS@#After one week's drug treatment, IMR was significantly decreased in both statins intensive group and Danhong Injection group compared with the control group (P<0.01), but no difference was found between statins intensive group and Danhong injection group (14.03 ± 2.54 vs. 16.03 ± 5.72 U, P=0.080).@*CONCLUSIONS@#The efficacy of Danhong Injection is non-inferior to statin. Early use of Danhong Injection after PCI can effectively improve coronary microcirculation injury after PCI.
RESUMO
Objectives: To explore the clinical experience for a bridge therapy of percutaneous balloon aortic valvuloplasty (PBAV) in treating the patients with severe aortic stenosis (AS). Methods: A total of 37 patients with severe AS who were not suitable for surgical valvular replacement received PBAV in our hospital from 2011-03 to 2017-03 were retrospectively studied. The patient's mean age was (74±12) years, their clinical and anatomical features, efficacy and safety of operation were observed and the outcomes were evaluated by follow-up study. Results: Patients presented the high surgical risk and worse cardiac function, 50% of them had bicuspid leaflet morphology with severe calcification [HU850=(856.0±658.2) mm3]. Balloon size was chosen by the intra-operative supra-annular diameters; at 7 days after operation, aortic valve orifice area (AVOA) was increased from (0.37±0.10) cm2to (0.87±1.10) cm2, the mean trans-aortic valve gradient pressure decreased form (55.1±22.9) mmHg to (44.8±17.8) mmHg, P<0.001 and LVEF elevated form(35.8±14.3)% to(41.0±12.2)%,P<0.001.There were 4 patients died in hospital,1 received permanent pacemaker and 1 developed severe aortic valve regurgitation. The patients were followed-up for (16.5±11.1)months after operation, 13/37 (35.1%) patients were in transition to surgical or transcatheter aortic valve replacement (TAVR). Conclusions: PBAV may have good early clinical efficacy in severe AS patients who were not suitable for surgical valvular replacement and TAVR; PBAV could be expected to become a bridge therapy, smaller supra-annular diameter was safe and effective for patients having bicuspid leaflet with severe calcification.
RESUMO
<p><b>BACKGROUND</b>ST-elevated acute myocardial infarction (STEAMI) happening in the first month post percutaneous coronary intervention (PCI) is almost related to acute thrombosis or subacute thrombosis in-stents. This study aimed to investigate the possible causes of myocardial infarction one month later.</p><p><b>METHODS</b>Patients who had a history of successful PCI, and received coronary angiography or re-PCI due to STEAMI were included in this study. The AMI-related lesions and previous angiographic findings such as the number of lesions, the degree of the stenosis, the type of stents and acute results of last PCI were recorded. If the AMI-related lesion was localized in-stents or at the edge of stents (distance apart from the edge < or = 5 mm), it was defined to be late thrombosis; otherwise as a new-lesion induced AMI.</p><p><b>RESULTS</b>One hundred and ninety-two patients aged 40 - 79 years were included in this study. New lesions, as the cause of STEAMI, were found in 144 patients (Group A, 75%), and late thrombosis in 48 patients (Group B, 25%). Almost all newly built thromboses were found at the sites of previous insignificant lesions (diameter stenosis < 50%). There was a significant difference in the average time from previous PCI to AMI ((30.1 +/- 12.4) vs (20.3 +/- 11.9) months) between the two groups. Diabetes mellitus (DM) and drug-eluting stent (DES) utilization were associated with markedly higher morbidity of late thrombosis in adjusted Logistic regression (hazard ratio (HR) 3.4, 95% confidence interval (CI) 1.1 - 10.9 and 5.3, 95% CI 1.1 - 26.5).</p><p><b>CONCLUSIONS</b>STEAMIs happening 1 month after PCI are more likely to develop from previous insignificant lesion rupture than from late thrombosis in-stents. Moreover, DM and DES are associated with the high incidence of late thrombosis, which may indicate that intensive antiplatelet therapy should be considered in patients with diabetes.</p>
Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia Coronária com Balão , Angiografia Coronária , Trombose Coronária , Patologia , Stents Farmacológicos , Infarto do Miocárdio , PatologiaRESUMO
<p><b>OBJECTIVE</b>The aim of this study was to assess the long-term clinical outcome of patients with diabetes mellitus and chronic total occlusion (CTO) underwent drug-eluting stents (DES) implantation.</p><p><b>METHODS</b>Data of 143 consecutive eligible patients from January, 2006 to May, 2007 were retrospectively analyzed. The endpoint of the study was the major adverse cardiac events (MACE), including death, myocardial infarction, target lesion revascularization. The patients were divided into two groups, event group and non-event group, according to the result of follow-up.</p><p><b>RESULTS</b>Long-term follow-up was finished in 139 (97.2%) patients. Mean follow-up duration was (19.8 + or - 5.1) months. MACE rate was 10.5% during follow-up: 3 deaths, 1 myocardial infarction and 11 repeated target lesion revascularization with PCI. Compared with the non-event group, the percentage of residual lesion [(17.7 + or - 1.8)% vs. (15.4 + or - 5.0)%, P = 0.001] was significantly higher in the event group, however, the final minimal luminal diameter [(2.14 + or - 0.22)% vs. (2.89 + or - 0.37)%, P = 0.004] was lower. Cox regression analysis showed that final luminal diameter (OR: 0.097, 95%CI: 0.013 - 0.694, P = 0.020) was the only dependent predictor at follow-up.</p><p><b>CONCLUSION</b>Final minimal luminal diameter is an independent predictor of MACE during follow-up for patients with diabetes and CTO underwent DES implantation.</p>