Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Coreano | WPRIM | ID: wpr-173740

RESUMO

BACKGROUND: Ventrlcular tachyarrhythmias are major cause of sudden cardiac death in patients after myocardial infarction and their accurate detection seems to be important in prevention of sudden cardiac death. Clinical findings, treasmill test, holter monitoring and coronary angiography have been used to search for high risk group in sudden cardiac death. Recently electrographysiologic stimulation has been to this, but it is not practical, because of high cost and invasiveness. Signal averaged electrocardiogram(SAECG) may be helpful in prediction of high risk group in sudden cardiac death. So we try to know the values of SAECG in Korean patients without heart disease. RESULTS: 1) The mean value and standard deviation of Time domain analysis is as follows ; fQRS : 106.8+/-12.3ms, RMS : 36.2+/-21.5(micro)V, LAS : 27.2+/-8.1ms. 2) The mean value and standard deviation of Spectral turbulence analysis is a follows ; LSCR : 58.6+/-3.9, ISCM : 95.2+/-0.8, ISCSD : 71.8+/-15.7, SE : 6.9+/-1.8. CONCLUSION: There was no significant difference between male and female. Time domain analysis shows significant differences among each hour but spectral turbulence analysis did not. Spectral turbulence analysis shows high specificity.


Assuntos
Feminino , Humanos , Masculino , Angiografia Coronária , Morte Súbita Cardíaca , Eletrocardiografia , Eletrocardiografia Ambulatorial , Cardiopatias , Coração , Infarto do Miocárdio , Sensibilidade e Especificidade , Taquicardia
2.
Korean Circulation Journal ; : 1123-1129, 1997.
Artigo em Coreano | WPRIM | ID: wpr-79660

RESUMO

BACKGROUND: We addressed the problem of the circadian changes in neural control of the circulation in ambulant hypertensive subjects. With spectral analysis of heart rate variability the tonic sympathetic and vagal activities and their changes are respectively assessed by the power of 0.050 - 0.015Hz(low frequency, LF) and 0.150 - 0.350Hz(respiratory linked, high frequency, HF) components of the spectrum of the beat by beat variability of RR interval. METHODS: Heart rate variability(HRV) and its circadian rhythm were evaluated in 15 patients with hypertension. By using 24-h Holter monitoring, HRV and its spectral components were measured. Finding were compared with 15 age-matched normal controls. RESULTS: The 24-hour plot of the SDs revealed that heart rate variability was significantly lower in the hypertensive patients, and the differences reached statistical significance during hours 2, 3, 9, 13, 16, 18, 19, and 23(p<0.05). Spectral analysis showed that power in the high-frequency range(0.150 to 0.350Hz) was lower among the hypertensive patients than among the normal controls during 22 of 24 hours but that the difference was statistically significant only during 2 hours(p<0.05). Power in the low frequency range(0.050 to 0.150Hz) was low at night, increased in the morning, and high during the day among controls ; this circadian rhythm was absent among hypertensive patients. CONCLUSIONS: Among hypertensive patients, HRV is decreased with a partial withdrawal of parasympathetic tone, and the circadian rhythm of sympathetic/parasympathetic tone is altered.


Assuntos
Humanos , Ritmo Circadiano , Eletrocardiografia Ambulatorial , Frequência Cardíaca , Hipertensão
3.
Korean Journal of Medicine ; : 371-379, 1997.
Artigo em Coreano | WPRIM | ID: wpr-56215

RESUMO

OBJECTIVE: Heart rate variability(HRV) is helpful to diagnosis autonomic disturbance and sympathetic-parasympathetic imbalance in patients with myocardial infarction and diabetes mellitus. Patients with liver cirrhosis demonstrate reduced blood pressure despite increased heart rate and increased cardiac output, indicating a fall in peripheral vascular resistance. Autonomic disturbance may contribute to this phenomenon. The aim of the present study is to evaluate the degree of autonomic disturbance and the circadian rhythm of autonomic nervous system by estimating HRV with 24 hour-Holter recorder, METHODS: 24 hour-HRV with Del Mar Avionics 563 Holter recorder and cardiovascular reflex tests were carried out on 32 patients with liver cirrhosis and 20 control subjects. We evaluated the presence of autonomic disturbance, and assessed quantitatively the autonomic disturbance. RESULTS: 1) Among cardiovascular reflex tests, Valsalva test, standing test and deep breathing test were showed a significantly decreased response in liver cirrhosis compared with control groups. 2) The standard deviation of 24hours average R-R intervals were showed a significantly decrease in liver cirrhosis than control groups(P<0.0001). The HRV of low frequency(LF. P<.D.001), high frequency(HF, P<0.0001) and total power spectral density (P<0.0001) in liver cirrhosis were statistically lower than control. 3) The LF/HF ratio of patients with liver cirrhosis was showed higher than control at night CONCLUSION: Non-invasive assessment of 24 hour-HRV has a few advantages in the diagnosis and degree of autonomic disturbance, evaluation of diurnal variation of autonomic tone.


Assuntos
Humanos , Sistema Nervoso Autônomo , Pressão Sanguínea , Débito Cardíaco , Ritmo Circadiano , Diabetes Mellitus , Diagnóstico , Frequência Cardíaca , Coração , Cirrose Hepática , Fígado , Infarto do Miocárdio , Reflexo , Respiração , Resistência Vascular
4.
Korean Circulation Journal ; : 674-680, 1996.
Artigo em Coreano | WPRIM | ID: wpr-23803

RESUMO

OBJECTIVES: Power spectrum analysis decomposes the heart rate signal into its frequency components and facilitates separation of sympathetic (low frequency) and parasympathetic (high frequency) activity. In congestive heart failure, augmented sympathetic tone and decreased parasympathetic tone were found. Autonomic nervous system was normalized 6 months after myocardial infarction. So we compared the autonomic nervous system activity by the heart rate variability in congestive heart failure and old myocardial infarction. METHODS: The protocol involved 20 healthy subjects (Group 1), 5 congestive heart failure patients not caused by myocardial infarction (Group 2), 4 congestive heart failure patients due to myocardial infarction and 11 old myocardial infarction patients without heart failure. We took 24 hour Holter monitoring by Del Mar Avionic tape recorder. All Holter tapes were analyzed with use of Model 563 Stratascan Holter Analysis System. We computed power spectra on each 256 sec segment of each hour during 24 hour recording. So, RR interval, SD of RR interval by time domain, and LF, HF, LF/HF ratio, Total PSD by frequency domain were measured. RESULTS: In congestive heart failure, nocturnal HF peak and diurnal variation of LF/HF ratio was decreased relative to healthy subjects. Nocturnal HF peak in old myocardial infarction was not visualized. All of LF, HF and Total PSD in congestive heart failure and old myocardial infarction patients relative to healthy subjects. CONCLUSION: On heart rate variability analysis using by 24 hour Holter monitoring, abnormal autonomic nervous activity was demonstrated in congestive heart failure and old myocardial infarction patients relative to healthy subjects.


Assuntos
Humanos , Sistema Nervoso Autônomo , Eletrocardiografia Ambulatorial , Estrogênios Conjugados (USP) , Insuficiência Cardíaca , Frequência Cardíaca , Coração , Infarto do Miocárdio , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA