RESUMO
PURPOSE: The purposes of the present study were to review published studies that investigated arthroscopic meniscus repair to treat meniscus injury in young patients and to compare all-inside and inside-out suture techniques. METHODS: Various electronic databases were queried for published articles, and this search was updated in August 2017 for evaluating the outcomes of arthroscopic meniscus surgery in young patients. Data search, extraction, analysis, and quality assessment were performed according to the Cochrane Collaboration guidelines, and the clinical outcomes were evaluated using various outcome values in young patients according to suture techniques. RESULTS: Three randomized controlled trials and three prospective comparative studies were included in this systematic review and meta-analysis. There were no significant differences in clinical outcomes such as meniscus healing rate (risk ratio [RR], 1.11; 95% confidence interval [CI], 0.90 to 1.37; I²=39%) and perioperative complications (RR, 0.62; 95% CI, 0.23 to 1.72; I²=43%) between all-inside and inside-out techniques for meniscus repair. CONCLUSIONS: The present study shows favorable results for clinical outcomes such as meniscus healing rate and perioperative complications in young patients. Furthermore, based on our results, both all-inside and inside-out meniscal suture techniques are equally effective in these patients.
Assuntos
Humanos , Comportamento Cooperativo , Joelho , Estudos Prospectivos , Técnicas de Sutura , Suturas , LágrimasRESUMO
Carpal malalignments in malunion of distal radius fracture are considered as an adaptive response of the carpus to loss of normal architecture of the distal radius. This condition leads to mechanical overload, ligament attenuation and progressive dynamic instability around the wrist joint. Radial corrective osteotomy is suggested as a treatment option of carpal malalignment after distal radius malunion. In radiocarpal malalignment, the lunate is usually observed in flexion in contrast to its extension posture in the more common midcarpal malalignment. We report two cases of fixed lunate flexion deformity after a distal radius fracture, in which reduction and fixation of fresh fracture or corrective osteotomy of malunion were not successful. Arthritic changes were observed in the radiolunate joint on arthroscopy. Thus, fixed flexion deformity of the lunate might be associated with posttraumatic arthritic change in the radiolunate joint.
Assuntos
Artroscopia , Anormalidades Congênitas , Articulações , Ligamentos , Osteotomia , Postura , Fraturas do Rádio , Rádio (Anatomia) , Articulação do PunhoRESUMO
Carpal malalignments in malunion of distal radius fracture are considered as an adaptive response of the carpus to loss of normal architecture of the distal radius. This condition leads to mechanical overload, ligament attenuation and progressive dynamic instability around the wrist joint. Radial corrective osteotomy is suggested as a treatment option of carpal malalignment after distal radius malunion. In radiocarpal malalignment, the lunate is usually observed in flexion in contrast to its extension posture in the more common midcarpal malalignment. We report two cases of fixed lunate flexion deformity after a distal radius fracture, in which reduction and fixation of fresh fracture or corrective osteotomy of malunion were not successful. Arthritic changes were observed in the radiolunate joint on arthroscopy. Thus, fixed flexion deformity of the lunate might be associated with posttraumatic arthritic change in the radiolunate joint.
Assuntos
Artroscopia , Anormalidades Congênitas , Articulações , Ligamentos , Osteotomia , Postura , Fraturas do Rádio , Rádio (Anatomia) , Articulação do PunhoRESUMO
PURPOSE: The purpose of this study is to report the results of culture test at the time of removal of metal devices used for management of ankle fractures and for analysis of contributing factors. MATERIALS AND METHODS: We reviewed medical records of 132 patients with lower tibia and ankle fracture who had their metal devices removed during the period from January 2010 to February 2014. Patients with clinical signs of infection were excluded. Culture test was performed by taking the granulation tissue around the metal device at the time of removal. We divided the subjects into two groups, culture positive and negative. We then performed a retrospective review of each medical record of multiple factors that might contribute to the culture results, including laboratory results, medical history, material and size of metal device, indwelling period, and whether or not it was open injury. RESULTS: Among 132 cases, six were culture positive. Enterococcus was detected in two cases and the others were Staphylococcus. No significant difference in medical history of patients and laboratory results, including C-reactive protein level, was observed between the culture positive and negative group. Culture positive rate was 5.4% in titanium and 3.9% in stainless steel. In terms of metal size, culture positive rate was 5.1% in small plates, 6.7% in large plates, and culture negative in intramedullary nails. The average indwelling period of metal device was 61.5 weeks in the culture positive group, and 68.6 weeks in the negative group. Nine cases were open fractures and all were in the culture negative group. CONCLUSION: Whether or not the culture result was positive, there were no meaningful contributing factors. Presence of bacterium on the metal device could not be screened by any laboratory results or other factors.