Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1557212

RESUMO

Abstract This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Resumo Este estudo avaliou o efeito de um novo método para aplicação do sistema adesivo na resistência de união entre pino de fibra e dentina radicular usando dois sistemas adesivos. Os canais de sessenta incisivos bovinos foram preparados e obturados. As raízes foram divididas em seis grupos (n=10) de acordo com o sistema adesivo (Clearfil SE - CSE e Single Bond Universal - SBU) e com a estratégia de aplicação (microbrush - MB, escova rotatória - RB e inserto ultrassônico - US). Os pinos de fibra foram cimentados utilizando cimento resinoso (RelyX ARC). As raízes foram seccionadas perpendicularmente ao seu longo eixo e três fatias foram obtidas. Previamente ao teste de push-out, foi realizada microscopia de varredura confocal a laser para ilustrar a adaptação interfacial do cimento às paredes do canal radicular. Os padrões de falha foram analisados com magnificação de 40x. O teste de Shapiro-Wilk indicou distribuição normal dos dados. Os valores de resistência de união foram comparados usando o teste ANOVA de uma via e post hoc de Tukey. As diferenças entre os sistemas adesivos em cada terço e de acordo com cada protocolo foram analisadas pelo teste T de Student. O nível de significância foi de 5%. CSE aplicado com RB apresentou maiores valores médios de resistência de união do que quando aplicado com MB (técnica convencional) (P<0,05). Aplicação com US apresentou valores intermediários de resistência de união para o CSE (P>0,05). A aplicação do SBU utilizando RB gerou maiores valores médios de resistência de união comparados com MB e US (P<0,05). Falhas adesivas foram predominantes (65,5%). A aplicação do CSE e SBU com a nova escova rotatória melhorou a resistência de união dos pinos de fibra à dentina radicular comparados com a estratégia convencional.

2.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513030

RESUMO

This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) - Bio-C Temp and Ultracal - after different activation protocols in teeth with simulated internal root resorption. Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05). There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05). Due to this, it can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption.

3.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513031

RESUMO

Aims: This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) -Bio-C Temp and Ultracal -after different activation protocols in teeth with simulated internal root resorption.Materials and methods: Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05).Results:There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05).Conclusion:It can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption.

4.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513032

RESUMO

Aims: This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) -Bio-C Temp and Ultracal -after different activation protocols in teeth with simulated internal root resorption.Materials and methods: Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05).Results:There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05).Conclusion:It can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption

5.
J. res. dent ; 10(1): 1-8, jan.-mar2022. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1378176

RESUMO

This study aimed to evaluate if 2.5% sodium hypochlorite compromises the adhesion of bonding materials. The factors in the study were the irrigation solutions in two levels: 2.5% sodium hypochlorite and saline solution; and the adhesive systems used in three levels: three-step adhesive, universal adhesive, and two-step self-etch adhesive systems. The answer variable used was the microshear bond strength obtained through a universal testing machine and fracture mode. Six groups were obtained (n=10) : Etch-and-rinse/Saline (saline solution + 3-step adhesive system - Scotchbond Multipurpose, 3M ESPE); Universal/saline (saline solution + universal adhesive system ­ Prime&Bond,); Self-etch/saline (saline solution + 2-step self-etch adhesive systems - Clearfil SE Bond); Etch-and-rinse/Hypo (sodium hypochlorite 2,5% + 3-step adhesive system - Scotchbond Multiuso); Universal/Hypo (sodium hypochlorite 2,5% + universal adhesive system ­ Prime&Bond); Self-etch/Hypo (sodium hypochlorite 2,5% + 2-step self-etch adhesive system - Clearfil Se Bond). The specimens were obtained from 60 healthy bovine incisors. The crowns were separated from the roots, and the regularization of the buccal surface was performed. The groups received saline solution and 2.5% sodium hypochlorite for 30 minutes, respectively. A matrix of 1mm and 3mm oh height was stabilized by Scotch tape to obtain the resin sticks. Afterward, the bond strength test was performed in a universal testing machine at 1mm/min speed. The data were analyzed with normality Shapiro-Wilk, two-way ANOVA, and Tukey's tests (p<0.001). Etch-and-rinse and Self-etch adhesives presented the highest bond strength values after irrigation with saline solution and 2.5% sodium hypochlorite, respectively (P < 0.01). The irrigation with 2.5% sodium hypochlorite decreased the bond strength values of Etch-and-rinse and Universal (P < 0.01). On the other hand, 2.5% sodium hypochlorite improved the bond strength values of Self-etch (P < 0.01). In conclusion, 2.5% sodium hypochlorite negatively impacted the bond strength of Etch-and-rinse and Universal but improved the adhesion of Self-etch.


Assuntos
Animais , Bovinos , Hipoclorito de Sódio/administração & dosagem , Adesivos/química , Desinfecção , Colagem Dentária/métodos , Cimentos Dentários/uso terapêutico , Hipoclorito de Sódio/uso terapêutico , Solução Salina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA