Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Rev. Flum. Odontol. (Online) ; 1(66): 144-154, jan-abr.2025. ilus
Artigo em Português | LILACS, BBO | ID: biblio-1570750

RESUMO

O avanço da tecnologia de digitalização de imagens e desenvolvimento de dispositivos de fresagem possibilitaram a otimização de diversos processos na Odontologia. O emprego do escaneamento intraoral e do sistema CAD-CAM (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) aprimorou a realização de reabilitações protéticas, permitindo a obtenção de peças de alta qualidade em tempo reduzido. O objetivo deste trabalho é relatar um caso de reabilitação de um incisivo central inferior a partir de escaneamento intraoral, com scanner Omnicam (DentsplySirona Charlotte, NC, EUA) e aplicação do sistema CAD-CAM.


The advancement of image digitization technology and the development of milling devices have made it possible to optimize various processes in Dentistry. The use of intraoral scanning and the CAD-CAM system (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) has improved the performance of prosthetic rehabilitations, allowing the obtaining of high quality parts in a reduced time. The objective of this work is to report a case of rehabilitation of a lower central incisor using intraoral scanning, with an Omnicam scanner (Dentsply Sirona) and application of the CAD-CAM system.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Reabilitação , Desenho Assistido por Computador , Odontologia , Modelos Anatômicos
2.
Artigo em Inglês | BBO, LILACS | ID: biblio-1052030

RESUMO

Introdution: Immediate implants placement has shown contradictory results inthe posterior region. Objective: The aim of the study was to compare the successrate and predictability of the short-term treatment using immediate implants inanterior and posterior regions. Methods: A total of 1000 dental charts wereanalyzed, of which 43 were included in the study: anterior (n=20) and posterior(n=23). The inclusion criteria were: tooth extraction indication, immediate single-tooth implant placement and at least twelve months of follow-up with functionalimplant. The success rates were based on the criteria I. and II. from the healthscale for dental implants proposed at the International Congress of Oral ImplantDentistry: no pain; no mobility, until 4 mm of bone loss, no exudate. P-value <0.05was considered significant. Results: The total success rate of immediate implantswas 97.7% for immediate implants in function for at least 12 months. The use ofbiomaterial (p=0.03) and temporary prosthesis (p<0.0001) were significantly higherin the anterior group. There was no significant difference in implant failure betweengroups (p=0.47). There was no statistical difference between the groups, consideringage, sex, extraction reason, initial torque immediately following implantplacement, treatment time and implant platform type (p> 0.05). Conclusion: Itmay be concluded that the anterior and posterior regions present a high short-term success rate when the immediate implant technique was used.


Introdução: A utilização de implante imediato em regiões posteriores temapresentado resultados contraditórios. Objetivo: O objetivo deste estudo foicomparar o índice de sucesso e previsibilidade à curto prazo de implantes imediatosinstalados em regiões anterior e posterior. Métodos: Um total de 1000 prontuáriosforam analisados, dos quais 43 foram incluídos neste estudo: Anterior (n=20) eposterior (n=23). Os critérios de inclusão foram: Indicação de extração dentária,instalação de implantes imediatos unitários, no mínimo doze meses de segmentocom implante funcional. Os critérios de sucesso foram baseados na escala desaúde dos implantes dentários do Congresso Internacional de Implantologia Oral,eixo I. e II.: ausência de dor, ausência de mobilidade, ausência de exudato e perdaóssea de até 4 mm. Valor de p<0.05 foi considerado estatisticamente significante.Resultados: O índice de sucesso dos implantes imediatos foi de 97,7% paraimplantes em função por pelo menos 12 meses. O uso de biomaterial (p=0,03) eprótese provisória (p<0,0001) foi significantemente maior em região anterior.Não foi encontrado diferença significante quanto a falha dos implantescomparando os dois grupos (p=0,47). Não houve diferença estatisticamentesignificante entre os grupos, considerando a idade, gênero, motivo da extração,torque inicial, tempo de tratamento e tipo de plataforma do implante (p>0,05).Conclusão: Pode-se concluir que as regiões anterior e posterior apresentaramalta taxa de sucesso a curto prazo quanto a técnica de implante imediato.


Assuntos
Prostodontia , Implantes Dentários , Implantação Dentária
3.
Braz. dent. j ; 29(1): 14-22, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888726

RESUMO

Abstract tHistory of chronic periodontitis (CP) is a risk factor for oseointegration failure. The osteoclastogenesis system (RANK, RANKL and OPG) is critical for bone homeostatic control. We investigated the levels of OPG and RANKL in peri-implant tissues from volunteers with and without a history of CP and their association with mucosae inflammation. This is a single-blind case-contro study. Diagnosis of a history of CP and peri-implant examination was performed on 46 volunteers, divided into control (without history of CP, n=26) and CP group (with history of CP, n=20). Gingival biopsies were harvested during implant exposure. Quantitative PCR evaluated OPG/RANKL mRNA expressions. OPG and RANKL proteins were analyzed by western blot and immunohistochemistry assay. The chi-square test analyzed the significance of nominal variables between groups while continuous variables were analyzed by T-test or Mann-Whitney test, after Shapiro-Wilk test evaluation. The 2-ΔΔCT Livak method calculation evaluated the gene expression. Values of p<0.05 were considered statistically significant. Volunteers with CP history had 23 times higher chance of developing mucosae inflammation. High mucosae levels of RANKL (p=0.04) and RANKL/OPG (p=0.001) mRNA expressions were observed in CP group. CP volunteers showed increased RANKL protein levels in opposition to decreased OPG expression. Even without active periodontitis, volunteers with a history of CP had elevated gingival levels of RANKL/OPG and higher correlation with peri-implant mucosae inflammation and implant loss.


Resumo A história de periodontite crônica (CP) é um fator de risco para falhas na osseointegração. O sistema de osteoclastogênese (RANK, RANKL e OPG) é crucial para o controle da homeostase óssea. O objetivo deste estudo foi investigar os níveis de OPG e RANKL no tecido peri-implantar de voluntários com e sem histórico de CP e sua associação com inflamação da mucosa. Este é um estudo tipo caso-controle. O exame para diagnóstico de CP e na região peri-implantar foi realizado em 46 voluntários, divididos em controle (sem história CP, n=26) e grupo CP (com histórico de CP, n=20). Descartes gengivais foram obtidos durante a exposição do implante. PCR quantitativo avaliou a expressão do RNAm de OPG/RANKL. As proteínas OPG e RANKL foram analisadas por western blot e imunohistoquímica. O teste do qui-quadrado analisou a significância entre as variáveis nominais enquanto as variáveis contínuas foram analisadas pelo teste-t e Mann-Whitney, após o teste de Shapiro-wilk. O método do Livak 2--ΔΔCT avaliou a expressão gênica. Os voluntários com CP apresentaram 23 vezes mais chances de desenvolver inflamação da mucosa. Expressão elevada no RNAm de RANKL (p=0.04) e RANKL/OPG (p=0.001) foram observadas no grupo CP. Voluntários com CP mostraram aumento dos níveis da proteína RANKL em contraste com diminuída expressão de OPG. Mesmo sem periodontite ativa, voluntários com histórico de CP apresentaram elevado nível gengival de RANKL/OPG e alta correlação com inflamação peri-implantar e perda do implante.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Periodontite Crônica/metabolismo , Implantes Dentários , Mucosa Bucal/patologia , Osteoprotegerina/metabolismo , Ligante RANK/metabolismo , Western Blotting , Periodontite Crônica/patologia , Imuno-Histoquímica , Osteoprotegerina/genética , Reação em Cadeia da Polimerase , Ligante RANK/genética , RNA Mensageiro/genética
4.
Braz. dent. j ; 27(4): 367-374, July-Aug. 2016. tab
Artigo em Inglês | LILACS | ID: lil-794608

RESUMO

Abstract Despite the success of osseointegrated implants, failures have increased significantly, associated with development of peri-implantitis. Multiple factors influence the peri-implant bone loss, including environmental and genetic causes. BMPs (Bone morphogenetic proteins) are growth factors that induce bone formation. FGF (fibroblast growth factors) and their receptors (FGFRs) play important roles by controlling the levels of cell proliferation, differentiation and migration. BMP/FGF relationship is responsible for promoting bone regeneration and bone loss. The aim of this study was to analyze the correlation between BMP4, FGF3, FGF10 and FGFR1 genes and peri-implant bone loss. Two hundred and fifteen volunteers, with 754 dental implants, were submitted to oral examination and divided in healthy group (n=129) and peri-implantitis group (n=86). Thirteen polymorphisms in BMP4, FGF3, FGF10 and FGFR1 genes were analyzed individually and in haplotype. The chi-square test correlated genotypes, allelic and haplotype frequencies. Values of p<0.05 were considered significant. Volunteers with peri-implantitis demonstrated high incidence of total edentulism (p<0.0001) and thin peri-implant phenotype (p<0.04). Higher incidence of spontaneous bleeding, plaque and implant mobility was observed in peri-implantitis group (p<0.0001 for all). The TT polymorphic genotype for BMP4 rs2761884 was associated with healthy peri-implant (p=0.01). FGF3 rs4631909 (TT+CT genotype) also showed association with the control group (p=0.04). The frequency of C allele for FGF3 rs4631909 showed a tendency for association with peri-implantitis (p=0.08). FGF10 CCTG (p=0.03), BMP4 GAAA (p=0.05) and GGGA (p=0.02) haplotypes were associated with peri-implantitis (p=0.03). Therefore, it may be concluded that BMP4 and FGF10 haplotypes are associated with peri-implantitis.


Resumo Apesar do alto índice de sucesso em implantodontia, falhas tem aumentado drasticamente, estando associadas ao desenvolvimento de peri-implantite. A perda óssea peri-implantar é influenciada por múltiplos fatores, incluindo causas genéticas e ambientais. As BMPs (proteínas ósseas morfogenéticas) são fatores de crescimento indutores da formação óssea. Os FGFs (fatores de crescimento dos fibroblastos) e seus receptores (FGFRs) desenvolvem importante função na proliferação, diferenciação e migração celular. A relação BMP/FGF é responsável pela regeneração e perda óssea. O objetivo deste estudo foi estudar a possível correlação entre os genes BMP4, FGF3, FGF10 e FGFR1 e a perda óssea peri-implantar. Duzentos e quinze voluntários, com 754 implantes, foram submetidos ao exame oral e divididos em grupo saúde (n=129) e peri-implantite (n=86). Treze polimorfismos nos genes BMP4, FGF3, FGF10 e FGFR1 foram analisados individualmente e como haplótipos. O teste do qui-quadrado correlacionou as frequências dos genótipos, alelos e haplótipos. Valores de p<0,05 foram considerados estatisticamente significantes. Voluntários com peri-implantite mostraram alta incidência de edentulismo total (p<0,0001) e biotipo periodontal fino (p<0,04). Sangramento espontâneo, placa e mobilidade do implante foram altamente incidentes no grupo peri-implantite (p<0,0001). O genótipo polimórfico TT para BMP4 rs2761884 foi associado com saúde peri-implantar (p=0,01). FGF3 rs4631909 (genótipos TT+CT) mostraram associação com o grupo controle (p=0,04). A frequência do alelo C para FGF3 rs4631909 mostrou uma tendência de associação com peri-implantite (p=0,08). Os haplótipos FGF10 CCTG (p=0,03), BMP4 GAAA (p=0,05) e GGGA (p=0,02) foram associados com peri-implantite (p=0,03). Sendo assim, conclui-se que os haplótipos BMP4 e FGF10 estão associados com peri-implantite.


Assuntos
Humanos , Masculino , Feminino , Lactente , Adulto , Pessoa de Meia-Idade , Proteína Morfogenética Óssea 4/genética , Estudos Transversais , Fatores de Crescimento de Fibroblastos/genética , Predisposição Genética para Doença , Haplótipos , Peri-Implantite/genética , Método Duplo-Cego
5.
ImplantNews ; 12(5): 611-617, 2015. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-767513

RESUMO

Objetivo: avaliar, por meio da microscopia eletrônica de varredura, a desadaptação vertical entre análogos de implantes HE (hexágono externo) e diversos tipos de pilares protéticos. Material e métodos: quatro tipos de pilares foram usados: a) pilares pré-usinados de titânio; b) pilares personalizados de zircônia usinados pelo sistema CAD/CAM; c) pilares calcináveis com cinta metálica; e d) pilares calcináveis sem cinta metálica. Sete modelos de estudo foram confeccionados, cada um com quatro análogos 4,1 mm de diâmetro, conectados a um dos tipos de pilar mencionados anteriormente (28 corpos-de-prova). Os pilares de zircônia foram instalados com torque de 20 Ncm, e os metálicos com torque de 30 Ncm, conforme recomendação do fabricante. As imagens das interfaces análogos/pilares foram obtidas em MEV para geração de 144 medições das desadaptações mais 100 fotomicrografias dos corpos-de-prova. Resultados: as médias de desadaptação em micrômetros foram: a) 11,19 ± 5,54; b)2,62 ± 5,12; c) 11,31 ± 4,62; d) 18,04 ± 9,93. O teste Kruskal-Wallis mostrou diferença significativa entre os grupos analisados (p=0,005). O teste Student Newman-Keuls mostrou que pilares zircônia CAD/CAM apresentaram adaptação significativamente superior em relação aos demais tipos de pilares. Não houve diferença significativa quando foram utilizados os pilares calcináveis (com ou sem cinta metálica) ou os pilares pré-usinados em titânio. Conclusão: as imagens mostraram que existem diferenças significativas entre os pilares analisados. Apesar dos pilares zircônia CAD/CAM mostrarem os melhores resultados, excessos horizontais na base destes pilares foram detectados em relação à plataforma do análogo.


Objective: to perform a SEM evaluation of the vertical margin misfit at the implant/abutment interface of several prosthetic modalities. Material and methods: 4 abutment types were used: a) prefabricated titanium; b) CAD/CAM customized abutments; c) castable abutments with prefabricated metal collar, and d) castable abutments with no metallic collars. Seven models were fabricated, each one with 4.1 mm HE implant analogs (28 samples). The zirconia abutments were fastened with 20 Ncm torque and the metallic abutments with a 30 Ncm according to the manufacturer recommendations. The SEM images at the implant/abutment interfaces provided 144 measurements of margin misfit based on 100 electromicrographs. Results: the mean misfit values were (in micrometers): a) 11.19 ± 5.54; b) 2.62 ± 5.12; c) 11.31 ± 4.62; d) 18.04 ± 9.93. The Kruskal-Wallis test demonstrated a signifi cant difference among groups (p=0.005). The Student-Newman-Keuls test showed that the zirconia abutments were superior when compared among groups. No differences were seen for castable abutments (with/without metal collar) or for prefabricated titanium abutments. Conclusion: the images demonstrated significant differences among the analyzed abutment types. Although the zirconia CAD/CAM abutments had provided the best results, horizontal overhangs were also detected in relation to the analog platform.


Assuntos
Implantação Dentária , Microscopia Eletrônica de Varredura
6.
Artigo em Inglês | IMSEAR | ID: sea-139808

RESUMO

Background: Restorative materials must be capable not only of restoring the patient's masticatory function, but also to rescue the self-esteem of those maculated by a disharmonious smile. Among the esthetic materials available on the market, the choice frequently lies between ceramic or indirect laboratory resin restorations. Aim: This study assessed the resistance to compression of two laboratory resins found on the market, namely Artglass® and Targis® , considering Omega 900® ceramic from Vita as control. Materials and Methods: With the aid of stainless steel matrices, with internal dimensions of 8.0 mm diameter at the base, 9.0 mm in the top portion and 4.0 mm height, 15 test specimens were made, being 5 of each material to be tested. The test specimens were kept in distilled water for 72 hours and submitted to an axial load by the action of a point with a rounded tip 2 mm in diameter, adapted to an EMIC 500 universal test machine. The compression speed was 0.5 mm/min, with a load cell capacity of 200 Kgf. Results: The means of the results were calculated in kilogram-force (Kgf). The results found were treated by analysis of variance (ANOVA) and the differences found among the groups were identified by the Tukey test (5%). Conclusion: It was observed that the material Omega 900® offered significantly greater resistance to compression than the other two materials, which did not present statistically significant difference between them.


Assuntos
Análise de Variância , Resinas Compostas , Força Compressiva , Porcelana Dentária , Análise do Estresse Dentário , Restaurações Intracoronárias , Teste de Materiais
7.
Rev. bras. odontol ; 66(1): 28-32, jan.-jun. 2009. ilus
Artigo em Português | LILACS, BBO | ID: lil-575381

RESUMO

A reabilitação com prótese total fixa inferior implanto-suportada com carga imediata vem sendo realizada como uma alternativa viável, com excelente prognóstico e comodidade para o paciente, já que é concluída em um espaço de tempo curto, modificando-se desta forma o protocolo de dois estágios cirúrgicos para a instalação dos implantes e a instalação posterior da prótese. Tal procedimento se torna viável devido ao alto índice de sucesso da técnica, com resultados bastante satisfatórios. O propósito deste trabalho é relatar um caso clínico de carga imediata em implantes osseointegráveis utilizando prótese total fixa inferior com acompanhamento de dois anos.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante/métodos , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA