1.
Braz. dent. j ; 33(1): 57-67, jan.-fev. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1364488

RESUMO

Abstract The aim of this study was to evaluate the efficacy of an ultrasound device and the dentin surface morphology after removal of the caries dentin lesions by removal rate and scanning electron microscopy (SEM). The Knoop hardness test on the bovine dentin blocks (n = 20, 4x4x2mm) was performed to standardize the samples and only those with 38 ± 2 KHN were included. The dentin blocks were submitted to induction of artificial caries lesions, using the bacterial model. Strains of Streptococcus mutans and Lactobacillus acidophilus were used for 7 days. The caries dentin lesion was removed for 1 min, according to two methods: G1 - carbide bur under low-speed rotation (control group) and G2 - ultrasound device under refrigeration. For the removal rate, the samples were weighed 3 times: T0 (before induction), T1 (after induction) and T2 (after removal). Morphology evaluation of the residual dentin surface was performed by SEM. Data normality was verified by Shapiro-Wilk test (p ≥ 0.240). T-test for independent samples was applied to evaluate the removal rate. A significance level of 5% was adopted. G2 provided lower removal rate than G1 (G1: 3.68 mg and G2 = 2.26 mg). SEM images showed different morphological characteristics between the groups. G2 showed absent of smear layer, while G1 showed a visible smear layer over the surface. We concluded that ultrasound device provides minimally invasive removal with residual dentin exhibiting open dentin tubules and no smear layer formation and no bacteria, which infer the removal of the infected tissue.


Resumo O objetivo deste estudo foi avaliar a eficácia de um dispositivo ultrassônico e a morfologia da superfície dentinária após a remoção da dentina cariada por meio da taxa de remoção e imagens de microscopia eletrônica de varredura (MEV). Foi realizado o teste de dureza Knoop nas amostras de dentina bovina (n = 20, 4x4x2mm) afim de padronizar as amostras e foram incluídas apenas aquelas com 38 ± 2 KHN. As amostras de dentina foram submetidas à indução de lesões artificiais de cárie, utilizando-se modelo biológico contendo cepas de Streptococcus mutans e Lactobacillus acidophilus durante por 7 dias. As lesões foram removidas por 1 min, de acordo com dois métodos: G1 - fresa esférica sob baixa rotação (grupo controle) e G2 - dispositivo ultrassônico sob refrigeração. Para a taxa de remoção, as amostras foram pesadas em três tempos: T0 (antes da indução), T1 (após a indução) e T2 (após a remoção). A avaliação morfológica da superfície residual da dentina foi realizada por MEV. A normalidade dos dados foi verificada pelo teste de Shapiro-Wilk (p ≥ 0,240). Teste T para amostras independentes foi aplicado para avaliar a taxa de remoção. Foi adotado nível de significância de 5%. G2 apresentou menor taxa de remoção que G1 (G1: 3,68 mg e G2 = 2,26 mg). As imagens de MEV mostraram características morfológicas diferentes entre os grupos. G2 mostrou ausência de smear layer, enquanto G1 mostrou grande quantidade de smear layer sobre a superfície. Com base neste estudo in vitro, o dispositivo de ultrassom promoveu remoção minimamente invasiva e dentina residual exibindo túbulos dentinários abertos e mínima formação de smear layer.

2.
Braz. dent. sci ; 23(2): 1-8, 2020. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1095782

RESUMO

Objective: The aim of this in vitro study was to evaluate the efficacy of photodynamic inactivation (PDI) with erythrosine (E), using a light-emitting diode (LED) on planktonic cultures of Streptococcus mutans. Material and Methods: A Streptococcus mutans strain (UA 159) was used to prepare the suspensions containing 107 cells/mL, which was tested under different experimental conditions: a) LED irradiation in the presence of erythrosine as a photosensitizer (E+L+); b) LED irradiation only (P-L+); c) treatment with erythrosine only (E+L-); and d) no LED irradiation or photosensitizer (P) treatment, which served as a control group (P-L-). After treatment, strains were seeded onto MSBS agar for determination of the number of colony-forming units (CFU/mL). Results: The results were submitted to analysis of variance and the Tukey test (p < 0.05). No reduction in the number of CFU/mL was observed in the treatment group with erythrosine (E+L+) when compared to the control (P-L-). Conclusion: PDI using erythrosine did not reduce the number of CFUs per millimeter within the parameters in this study. (AU)


Objetivo: o objetivo deste estudo in vitro foi avaliar a eficácia da inativação fotodinâmica (PDI) com a eritrosina (E), usando diodo de emissão de luz azul (LED) em culturas planctônicas de Streptococcus mutans. Material e métodos: a cepa de Streptococcus mutans (UA 159) foi usada para o preparo das suspensões padrões contendo 107 células/mL, as quais foram testadas em diferentes condições experimentais a) irradiação com LED em presença da eritrosina como fotossensibilizador (E+L+); b) irradiação com LED apenas (F-L+); c) tratamento com eritrosina apenas (E+L-); e d) tratamento sem irradiação com LED ou fotossensibilizador (F), que serviu como grupo controle (F-L-). Após o tratamento, as cepas foram semeadas em ágar MSBS para determinação do número de unidades formadoras de colônias (UFC/mL). Resultados: os resultados foram submetidos à análise de variância e teste de Tukey (p < 0.05). Não foi observada redução no número de UFC/mL no grupo de tratamento com eritrosina (E+L+) quando comparado ao grupo controle (F-L-). Conclusão: a PDI usando etritrosina e LED não reduziu o número de UFCs por milímetro com os parâmetros utilizados neste estudo.(AU)


Assuntos
Streptococcus mutans , Fármacos Fotossensibilizantes , Cárie Dentária , Eritrosina
3.
Braz. dent. sci ; 17(1): 45-53, 2014. ilus, graf
Artigo em Inglês | LILACS, BBO | ID: lil-728106

RESUMO

Objective: This study assessed the Vickers hardness (VHN) provided by two LCUs when using (1) direct and indirect light-curing techniques, (2) 40 and 60 s and (3) top and bottom surfaces. Material & Methods: One halogen Curing Light 2500 (3M Espe) and one LED (MM Optics) were used by direct and indirect (0,1.0, 2.0 and 3.0 mm of dental structure) techniques during 40 and 60 s. The samples were made with FiltekTM Z250 in a metallic mould with a central orifice (4 mm in diameter, 2 mm in thickness). The samples were stored in dry mean by ± 24 h and the hardness measurements were performed in a testing machine (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). A 50 gf load was used and the indenter with a dwell time of 30 s. The data were submitted to multiple ANOVA and Newman-Keuls‘s test (p < 0.05). Results: Halogen LCU exhibited higher Vickers hardness values than LED mainly because of the power density used. Hardness values were influenced by LCUs, lightcuring techniques, irradiation times and surfaces. For both LCUs, hardness values were found to decrease with indirect light-curing technique, mainly for the bottom surface. Samples irradiated for 60 s exhibited higher hardness values when the halogen LCU was used. For 60 s, the VHN values were statistically significant greater than 40 s. Significant differences in top and bottom surfaces Vickers hardness number (VHN) values were observed among different LCUs used 40 and 60 s. Conclusion: The LCUs, lightcuring techniques, variations of irradiation times, and surfaces (top and bottom) influence the composite resin hardness.


Objetivo: Este estudo avaliou a dureza Vickers (VHN) em função de duas fontes de luz quando utilizadas diferentes (1) técnicas de fotoativação, direta e indireta, (2) 40 e 60 s, e (3) superfícies de topo e base. Material e Métodos: Uma fonte de luz halógena Curing Light 2500 (3M Espe) e um LED (MM Optics) foram utilizados nas técnicas de fotoativação direta e indireta (0 , 1,0, 2,0 e 3,0 milímetros de estrutura dental), durante 40 e 60 s. As amostras foram feitas utilizando-se FiltekTM Z250 em matriz metálica com orifício central (4 mm de diâmetro, com 2 mm de espessura). As amostras foram armazenadas em meio seco por ± 24 h e as medidas de dureza foram realizadas em microdurômetro (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). Uma carga de 50 gf durante 30 s foi utilizada. Os dados foram submetidos à análise de variância múltipla e teste de Newman-Keuls (p < 0,05). Resultados: A fonte de luz halógena promoveu os maiores valores de dureza Vickers, principalmente, em função da densidade de potência utilizada. Os valores de dureza foram influenciados pelas fontes de luz, técnicas de fotoativação, tempos de irradiação e superfícies, topo e base. Para ambas as fontes de luz, os valores de dureza diminuíram com a técnica de fotoativação indireta, principalmente para a superfície de base. Amostras irradiadas por 60 s apresentaram valores de dureza maiores quando a fonte de luz halógena foi utilizada. Durante 60 s , os valores de VHN foram estatisticamente significativos maior do que 40 s. Diferenças significativas foram observadas nos valores dureza Vickers (VHN) para as superfícies de topo e base utilizando 40 e 60 s. Conclusão: As fontes de luz, técnicas de fotoativação direta e indireta, tempos de irradiação e superfícies (topo e base) influenciam na dureza da resina composta.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária
4.
Rev. CEFAC ; 14(3): 506-515, mayo-jun. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-640895

RESUMO

OBJETIVO: avaliar a prevalência dos hábitos de sucção não nutritiva presentes em crianças pré-escolares do município de Araraquara-SP, buscando conhecer melhor suas características, distribuição e relação com o aleitamento materno. MÉTODO: aplicação de um questionário enviado aos pais ou responsáveis. A amostra foi composta por 1371 crianças com idades entre seis meses e cinco anos, na qual 702 crianças (51,2%) apresentavam hábitos deletérios, num total de 812 hábitos relatados. RESULTADOS: de acordo com os resultados, os hábitos foram mais prevalentes no gênero feminino (55%) e na faixa etária entre seis meses e dois anos. O hábito mais comumente encontrado foi o de sucção chupeta (30%), seguido pela sucção de mamadeira (18,4%) e sucção digital (7,6%), não havendo associação entre o tipo de hábito e condição sócio-econômica. Das crianças participantes, 1.239 (90,4%) receberam aleitamento materno, sendo que o tempo de maior prevalência de amamentação foi entre seis meses e 12 meses (43%), não necessariamente de forma exclusiva, mas por um período igual ou superior ao preconizado pela OMS. CONCLUSÃO: houve associação entre o tempo de amamentação com a presença e o tipo de hábito, visto que as crianças que receberam o aleitamento natural por um período superior a 12 meses tenderam a não desenvolver hábitos deletérios. Os resultados comprovam que quanto maior é o tempo de amamentação, menor é a prevalência de hábitos.


PURPOSE: to evaluate the prevalence of nonnutritive sucking habits in preschool children from Araraquara-SP, seeking to better understand their characteristics, distribution and relation to breastfeeding. METHOD: application of a questionnaire sent to parents or guardians. The sample comprised 1371 children aged between 6 months and 5-year old, where 702 children (51.2%) had deleterious habits, from a total of 812 reported habits. RESULTS: the habits were more prevalent in women (55%) and aged between 6 months and 2 years. The most commonly found practice was sucking a pacifier (30%), followed by suction bottle (18.4%) and sucking (7.6%), there was no association between the type of habit and socioeconomic status. From the participating children, 1,239 (90.4%) were breastfed, and the length of breastfeeding was most prevalent between 6 months and 12 months (43%), not necessarily exclusive but for a period not less than the recommended by WHO. CONCLUSION: there was an association between duration of breastfeeding in the presence and type of habit, since children who received breastfeeding for a period exceeding 12 months tended not to develop harmful habits. The results show that the greater the duration of breastfeeding is, the lower becomes the prevalence of habits.

5.
J. appl. oral sci ; 20(2): 212-217, Mar.-Apr. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-626423

RESUMO

OBJECTIVE:This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). MATERIAL AND METHODS: Filtek TM Z350 nanofilled composite resins and Amelogen® Plus, Vit-l-escenceTM and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free LightTM 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm-1) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). RESULTS: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey’s test showed that the nanofilled resin (FiltekTM Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (FiltekTM Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free LightTM 2). CONCLUSIONS: The nanofilled resin showed the lowest DC, and the Vit-l-escenceTM microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.


Assuntos
Lâmpadas de Polimerização Dentária , Resinas Compostas/química , Nanocompostos/química , Análise de Variância , Resinas Compostas/efeitos da radiação , Luz , Teste de Materiais , Nanocompostos/efeitos da radiação , Transição de Fase , Polimerização , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Fatores de Tempo
6.
ImplantNews ; 9(3): 367-373, 2012. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-654773

RESUMO

A Osseointegração envolve uma cascata de eventos biológico-celulares, que podem ser acelerados por meio da modificação micro e/ou nanométrica da topografia da superfície dos implantes dentais. Considerando-se que diferentes tipos de tratamentos modificam a superfície do titânio, conferindo-lhe uma topografia mais rugosa, além de alterações físico-químicas que parecem influenciar positivamente a osseointegração, foi realizada uma revisão da literatura sobre os principais tipos de tratamentos de superfícies de implantes de titânio e sua influência na Osseointegração do ponto de vista biológico-celular. Para a realização deste estudo foi feito um levantamento bibliográfico de publicações que datam de 1969 até o presente. Apesar do papel preciso da topografia e da química de superfície sobre a osseointegração de implantes dentários não estar completamente elucidado, os efeitos específicos da superfície de implantes sobre regeneração óssea inicial, cinética e evolução das propriedades mecânicas têm se mostrado bastante promissores. Assim, baseado nas modificações das superfícies de implantes dentais, a Osseointegração pode ser definida como um processo pelo qual a fixação rígida e assintomática de um material aloplástico pode ser alcançada e mantida em íntimo contato com o tecido ósseo, apresentando resistência às cargas funcionais precoces e tardias, podendo este processo ser modulado pelo adequado tratamento da superfície do material aloplástico.


Osseointegration involves a cascade of biological events, which can be accelerated by modifying the micro and/or nanometric topography of dental implant surfaces. Considering that different treatment types modify the titanium surface giving it a more pronounced rough topography, and physicochemical changes that appear to positively influence the osseointegration process, a literature review was made on the main types of surface treatments and their influence on the biological and cellular aspects of osseointegration, with publications dating from 1969 until the present moment. Although the precise role of the implant surface on the osseointegration of dental implants is not completely clear, the specific effects of implant surface on bone regeneration, initial kinetics, and evolution of mechanical properties have shown to be quite promising. Thus, based on dental implant surface modifications, osseointegration can be defined as a process by which rigid asymptomatic fixation of an alloplastic material can be achieved and kept in close contact with bone tissue, being resistant to early and late functional loads. This process can be modulated by an appropriate treatment of the alloplastic material surface.


Assuntos
Implantes Dentários , Osseointegração , Propriedades de Superfície
7.
RGO (Porto Alegre) ; 57(1): 27-31, jan.-mar. 2009. graf, ilus
Artigo em Português | LILACS, BBO | ID: biblio-873758

RESUMO

Métodos: Vinte e oito corpos de prova cilíndricos (8 x 1mm) de resina FiltekTM Supreme XT (3M ESPE, Sumaré, Brasil) foram preparados e divididos em 5 Grupos. A microdureza Vickers inicial foi mensurada (carga de 50 gramas força por 30 segundos) na superfície de topo dos corpos de prova. Os grupos foram tratados e divididos da seguinte maneira: G1) saliva artificial (21 dias - controle); G2) gel de peróxido de hidrogênio 7% aplicado por 4h/dia, durante 14 dias; G3) peróxido de carbamida 10% por 4h/dia, durante 14 dias: G4) gel de peróxidode hidrogênio 35% aplicado em três sessões de 30 minutos cada, com intervalo entre sessões de uma semana (21 dias); e G5) peróxido de carbamida a 35%, três sessões de 30 minutos cada, com intervalo entre sessões de uma semana (21 dias). As superfícies de topo dos corpos de prova receberam os tratamentos e foram submetidas ao teste de microdureza Vickers. Resultados: Os resultados obtidos foram submetidos à Análise de Variância a um critério fixo, com nível de significância p=0,05. Não foram observadas diferenças significativas entre os tratamentos testados (p=0,42) quando comparados com G1. Diferenças significativas (Teste Tukey) foram encontradas quando comparados os valores de microdureza inicial com os valores após os tratamentos experimentais (p<0,01). Conclusão: A aplicação dos agentes clareadores não alterou a microdureza das resinas compostas. Portanto não há necessidade de troca das restaurações após o clareamento.


Objective: To assess the effect of bleaching agents on the microhardness of nanoparticle resin composite. Methods: Twenty-eight cylindrical test specimens (8x1mm) of FiltekTM Supreme XT resin (3M/ESPE) were prepared and divided into 5 groups. The initial Vickers microhardness was measured (load of 50 grams force for 30 seconds) on the top surface of the test specimens. The groups were treated and divided as follows: G1 - artificial saliva (21 days - control); G2 - 7% hydrogen peroxide gel applied for 4h/day, for 14 days; G3 - 10% carbamide peroxide for 4h/day, for 14 days: G4 - 35% hydrogen peroxide gel applied in three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions; G5 - 35% carbamide peroxide, three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions. The top surfaces of the test specimens received treatment and were submitted to the Vickers microhardness test. Results: The results obtained were submitted to the Analysis of Variance at a fixed criterion, at a level of significance of p=0.05. No significant differences were observed among the treatments tested (p=0.42) when compared with G1. Significant differences (Tukey test) were found when the initial microhardness values were compared with the values after experimental treatments (p<0.01). Conclusion: The application of bleaching agents did not alter the microhardness of resin composites. Therefore, there is no need to changerestorations after bleaching.


Assuntos
Resinas Compostas , Clareamento Dental/efeitos adversos , Dureza , Estudos de Casos e Controles
8.
Rev. dental press estét ; 5(1): 89-98, jan.-mar. 2008. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-529387

RESUMO

Muitos fatores promovem influência no processo de fotoativação. Assim, o propósito deste estudo foi avaliar a interferência de diferentes comprimentos de onda e tempos de exposição na dureza, no grau de conversão e alteração de temperatura durante a fotoativação. A resina composta microhíbrida Filtek Z-250 (3M/ESPE) na cor A2 foi utilizada na confecção dos espécimes em matriz metálica (2mm de espessura e 5mm de diâmetro), sendo fotoativadas por laser de argônio (Coerente, Innova 200-20, EUA) em modo standard com intensidade constante por 15, 40 e 60 segundos de exposição para as medidas de dureza Vickers e alteração de temperatura. Para o teste de grau de conversão, os espécimes foram fotoativados durante 10 e 20 segundos. A análise dos valores médios para os diferentes testes foram realizadas pela Análise de Variância (ANOVA) e teste Tukey (p<0,05). Foi observada diferença estatisticamente significante entre os diferentes comprimentos de onda utilizados. O comprimento de onda de 488nm promoveu os maiores valores de dureza e grau de conversão e a menor alteração de temperatura. O comprimento de onda de 488nm foi mais eficiente no processo de fotoativação.


Assuntos
Resinas Compostas , Lasers , Análise de Variância , Testes de Dureza
9.
Rev. dental press estét ; 5(1): 122-129, jan.-mar. 2008. ilus
Artigo em Português | LILACS, BBO | ID: lil-529390

RESUMO

A estética dentária tem sido bem valorizada nos dias atuais. Dessa forma, um sorriso esteticamente harmonioso inclui características que variam de acordo com o gênero, alinhamento dos dentes no arco dentário, forma, textura superficial e cor dos elementos dentários. Assim, o profissional é constantemente procurado por pacientes ansiosos em terem seus dentes devidamente clareados ou esteticamente recuperados. Por outro lado, a procura por um sorriso esteticamente agradável deve estar vinculada à utilização de procedimentos minimamente invasivos, uma vez que, atualmente, a Odontologia preconiza a preservação da estrutura dentária sadia. A partir destas considerações, o presente artigo tem por objetivo apresentar o restabelecimento do contorno cosmético por meio da apresentação de um caso clínico, utilizando-se uma resina composta nanoparticulada, em uma paciente do gênero feminino que apresentava diastemas e ângulos incisais retos, ou seja, características incompatíveis com a harmonia do sorriso feminino. Por meio deste caso clínico concluímos que o emprego da técnica direta com esta nova categoria de resina composta proporciona além do restabelecimento estético (forma, cor e textura superficial) a preservação das estruturas dentárias sadias, uma vez que dispensa a confecção de preparos cavitários.


Assuntos
Humanos , Feminino , Adulto , Resinas Compostas , Adesivos Dentinários , Diastema , Estética Dentária , Restauração Dentária Permanente/métodos , Sorriso
11.
Rev. dental press estét ; 4(1): 115-123, jan.-mar. 2007. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-529347

RESUMO

O objetivo deste estudo foi avaliar a fluorescência de diferentes cores de uma resina composta e da estrutura dentária por meio de imagens de fluorescência conjugada ao processamento digital. A amostra foi constituída por 192 imagens, sendo 176 de corpos-de-prova de resina composta e 16 da estrutura dentária. Os corpos-de-prova foram confeccionados em matriz circular metálica, contendo orifíco central de 10mm de diâmetro e 1mm de espessura, sendo confeccionado 1 corpo-de-prova para cada uma das 11 cores avaliadas da resina composta Helio Fill (Vigodent). A análise digital da fluorescência foi realizada com auxílio de câmera CCD conectada ao computador, sendo a fluorescência analisada sob iluminação com LED UV. Foram coletadas 16 imagens pela câmera para cada corpo-de-prova e estrutura dentária e estas foram processadas matematicamente, quantificando a intensidade de fluorescência na escala de cinza. Foi aplicada análise de variância a um critério fixo e realizado teste de Tukey para os contrastes. Verificou-se que a tonalidade A1 apresentou maior média de intensidade de fluorescência e a tonalidade C3 apresentou a menor entre as resinas compostas. O comportamento foi semelhante para cores B1 e B2, bem como para A4 e C2. Porém, a intensidade média da estrutura dentária apresentou valor médio inferior a todas as cores avaliadas. Conclui-se que todas as cores analisadas sob iluminação UV possuem fluorescência superior à da estrutura dentária.


Assuntos
Resinas Compostas , Dentística Operatória , Fluorescência , Análise de Variância , Cor , Estética Dentária
12.
Rev. bras. odontol ; 64(1/2): 33-37, 2007. tab
Artigo em Português | LILACS, BBO | ID: lil-541849

RESUMO

O objetivo deste trabalho foi aplicar dois métodos de mensuração da infiltração marginal da resina composta com intuito de verificar qual delas permite maior confiabilidade dos resultados. Foram confeccionadas cavidades de classe V, com margem cervical em dentina, restauradas com o sistema restaurador Single Bond/Z250. As medidas de infiltração dos grupos foram realizadas por meio de dois métodos: análise por escores e análise por programa de computador específico (Image Tool), através do qual foram realizadas medidas para obtenção de valores em milímetros. A análise estatística demonstrou que não houve compatibilidade dos resultados obtidos através das duas técnicas.


Assuntos
Humanos , Infiltração Dentária , Resinas Compostas/normas , Dente Molar
13.
JBC j. bras. clin. odontol. integr ; 8(47): 415-418, out.-dez. 2004. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-444972

RESUMO

No presente estudo, avaliou-se a microdureza nas superfícies de topo e de base de corpos-de-prova confeccionados com duas marcas comerciais de resinas compostas micro-híbridas: Filtek Z-250 (3M) e Vistalescence (Ultradent), ambas nas cores A3 e incisal. Foram confeccionados cinco corpos-de-prova para cada grupo de materiais, cada corpo-de-prova teve suas superfícies de topo e de base divididas em quatro quadrantes e realizado o teste de microdureza Vickers com três impressões em cada quadrante, totalizando 120 impressões por grupo testado. Os resultados foram avaliados pelo teste de Tukey, significativo ao nível de 5%. As resinas de cor A3 apresentaram dureza Vickers significativamente superior às resinas translucentes, tanto nas superfícies de topo quanto nas de base. Observou-se também diferença significativa de microdureza entre as superfícies de topo e de base de todos os grupos testados


Assuntos
Cor , Resinas Compostas , Adesivos Dentinários , Testes de Dureza/métodos
14.
JBC j. bras. clin. odontol. integr ; 8(45): 249-253, maio-jun. 2004. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-436338

RESUMO

Este trabalho propôs-se a avaliar a intensidade da luz emitida por 100 aparelhos fotopolimerizadores, usados nas clínicas da Faculdade de Odontologia de Araraquara - Unesp, com o objetivo de alertar o Cirurgião-dentista sobre a necessidade de um constante controle e manutenção de sua unidade fotopolimerizadora, como um dos fatores determinantes para garantir uma adequada fotopolimerização. A avaliação foi realizada com um radiômetro (DMC; modelo CL-150), com o qual se constatou que 15% situavam-se em uma faixa abaixo de 200mW/cm², valor inadequado para uma satisfatória fotopolimerização


Assuntos
Humanos , Feminino , Adulto , Avaliação de Programas e Instrumentos de Pesquisa , Luz , Estudo de Avaliação , Manutenção de Equipamento/políticas
15.
RGO (Porto Alegre) ; 52(1): 7-12, jan.-mar. 2004. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-397039

RESUMO

O objetivo deste trabalho foi avaliar a capacidade de fotopolimerização do aparelho fotopolimerizador à base de luz halógena Ultralux (Dabi Atlante) e o sistema de LEDs Ultraled (Dabi Atlante) aplicados por 40 segundos em dois tipos de resinas compostas; híbrida Charisma (Heraeus-Kulzer) e outra de alta densidade ou condensável Filtek (TM) P60(3M), ambas na cor A3. Foram confeccionados 20 corpos-de-prova divididos em 4 grupos: Grupo I - Charisma (Heraeus-Kulzer) e Luz halógena; Grupo II - Charisma (Heraeus-Kulzer) e sistema de LEDs; Grupo III - Filtek (TM) P60 (3M) e luz halógena; Grupo IV - Filtek(TM) P60 (3M) e sistema de LEDs. Imediatamente após a fotopolimerização, obteve-se 12 valores de microdureza Vickers tanto na superfície de topo quanto na base dos corpos-de-prova. O aparelho de luz halógena proporcionou melhores resultados de microdureza do que o aparelho com sistema de LEDs para as duas resinas compostas avalidas e a resina composta Filtek(TM) P60 (3M) apresentou maiores médias de microdureza do que a resina composta Charisma (Heraeus-Kulzer)


Assuntos
Resinas Compostas , Dureza , Técnicas In Vitro , Luz
16.
Araraquara; s.n; 2004. 286 p. ilus, tab.
Tese em Português | LILACS, BBO | ID: lil-466891

RESUMO

O objetivo desse trabalho foi avaliar a capacidade de polimerização de uma fonte de luz halógena e um dispositivo LEDs utilizados na técnica de fotoativação trans-dental. Para isto, foram confeccionadas amostras em uma matriz metálica circular contendo um orifício central com 4 mm de diâmetro e 2 mm de profundidade (ISO 4049) utilizando-se a resina composta microhíbrida Filtek Z-250 (3M/ESPE), na cor A2. Cinco amostras foram confeccionadas para cada situação diferentes, distribuídas em grupos da seguinte maneira: GRUPO I - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental, nas mesmas condições de operação armazenados em meio seco por 24 horas, avaliados pelo teste de dureza Vickers (VHN); GRUPO II - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental nas condições originais de operação armazenados em meio seco por 24 horas e 30 dias, água destilada, saliva artificial e ácido acético a 10 percento por 30 dias, avaliados pelo teste de dureza Vickers (VHN)...


Assuntos
Resinas Compostas , Fluorescência , Dureza
17.
Rev. paul. odontol ; 20(4): 8-10, jul.-ago. 1998. ilus
Artigo em Português | LILACS, BBO | ID: lil-298330

RESUMO

O propósito deste trabalho é demonstrar, por meio de um caso clínico, a seqüência da técnica da microabrasäo bem como o material utilizado para a realizaçäo da mesma. Através desta técnica, manchas brancas presentes na superfície dentária vestibular dos incisivos centrais superiores foram removidos com sucesso. Nesta técnica foi utilizada uma pasta abrasiva formada por pedra pomes + ácido fosfórico a 37 por cento em quantidades iguais (1:1). A pasta foi aplicada à superfície dentária por meio de uma espátula de madeira fazendo-se movimentos circulares durante 10 segundos por aplicaçäo, totalizando 16 aplicaçöes. Além de apresentar bons resultados, esta técnica permitiu conservar a estrutura dentária, evitando dessa maneira procedimentos restauradores


Assuntos
Fluorose Dentária , Microabrasão do Esmalte/métodos , Hipoplasia do Esmalte Dentário