Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
J. forensic med ; Fa yi xue za zhi;(6): 37-42, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1017658

RESUMO

Objective To investigate the toxicokinetic differences of 3,4-methylenedioxy-N-methylamphetamine(MDMA)and its metabolite 4,5-methylene dioxy amphetamine(MDA)in rats af-ter single and continuous administration of MDMA,providing reference data for the forensic identifica-tion of MDMA.Methods A total of 24 rats in the single administration group were randomly divided into 5,10 and 20 mg/kg experimental groups and the control group,with 6 rats in each group.The ex-perimental group was given intraperitoneal injection of MDMA,and the control group was given intraperi-toneal injection of the same volume of normal saline as the experimental group.The amount of 0.5 mL blood was collected from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.In the continuous administration group,24 rats were randomly divided into the experi-mental group(18 rats)and the control group(6 rats).The experimental group was given MDMA 7 d by continuous intraperitoneal injection in increments of 5,7,9,11,13,15,17 mg/kg per day,respectively,while the control group was given the same volume of normal saline as the experimental group by in-traperitoneal injection.On the eighth day,the experimental rats were randomly divided into 5,10 and 20 mg/kg dose groups,with 6 rats in each group.MDMA was injected intraperitoneally,and the con-trol group was injected intraperitoneally with the same volume of normal saline as the experimental group.On the eighth day,0.5 mL of blood was taken from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.Liquid chromatography-triple quadrupole tandem mass spectrometry was used to detect MDMA and MDA levels,and statistical software was employed for data analysis.Results In the single-administration group,peak concentrations of MDMA and MDA were reached at 5 min and 1 h after administration,respectively,with the largest detection time limit of 12 h.In the continuous administration group,peak concentrations were reached at 30 min and 1.5 h af-ter administration,respectively,with the largest detection time limit of 10 h.Nonlinear fitting equations for the concentration ratio of MDMA and MDA in plasma and administration time in the single-administration group and continuous administration group were as follows:T=10.362C-1.183,R2=0.974 6;T=7.397 3C-0.694,R2=0.961 5(T:injection time;C:concentration ratio of MDMA to MDA in plasma).Conclusions The toxicokinetic data of MDMA and its metabolite MDA in rats,obtained through single and continuous administration,including peak concentration,peak time,detection time limit,and the relationship between concentration ratio and administration time,provide a theoretical and data foundation for relevant forensic identification.

2.
J. forensic med ; Fa yi xue za zhi;(6): 419-422, 2019.
Artigo em Inglês | WPRIM | ID: wpr-985028

RESUMO

Objective To develop a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for the determination of the content of 4-fluoromethamphetamine (4-FMA) in rat plasma, and to provide a methodological basis for the study of the toxicokinetics of 4-FMA in rats. Methods Rat plasma samples were added into internal standard methamphetamine (MA). Its proteins were precipitated with methanol and then separated with Poroshell 120 EC-C18 chromatographic column. A 0.1% formic acid aqueous solution and a 0.1% formic acid acetonitrile solution were used as the mobile phase at the flow rate of 0.4 mL/min. Electrospray ionization source was used for detection in the multiple reaction monitoring (MRM) mode. Results The linear relationship was good when the mass concentration of 4-FMA in plasma samples was in the range of 5-1 000 ng/mL (r>0.999). The limit of detection (LOD) was 3 ng/mL and the limit of quantification (LOQ) was 5 ng/mL. The accuracy was expressed as relative error (RE), and in the range of ±5%, the intra-day precision and inter-day precision (relative standard deviation, RSD) less than 9%, and the extraction recovery rate was more than 90%. The analysis and detection of plasma samples were completed within 2.5 min. Conclusion This study developed a HPLC-MS/MS method for the determination of 4-FMA in rat plasma samples. This method is accurate, rapid, simple and sensitive and can be applied to the study of toxicokinetics of 4-FMA.


Assuntos
Animais , Ratos , Cromatografia Líquida de Alta Pressão , Limite de Detecção , Metanfetamina/sangue , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Toxicocinética
3.
Yao Xue Xue Bao ; (12): 1743-1747, 2017.
Artigo em Chinês | WPRIM | ID: wpr-779784

RESUMO

This study was designed to investigate the metabolites of 5F-AMB by human liver microsomes model in vitro. 5F-AMB was added in the reaction mixture to simulate the metabolic process in human hepatocytes in vivo, and then to determine the reaction points and pathways of metabolism by ultra performance liquid chromatography (UPLC) coupled to high resolution mass spectrum (HR-MS). 5F-AMB generated 9 metabolites in total in the human liver microsomes model. Ester hydrolysis, combination of ester hydrolysis and oxidative defluorination, combination of ester hydrolysis and hydroxylation on pentyl chain moiety and combination of ester hydrolysis and hydroxylation on indazole ring moiety reactions were its main metabolic pathways. The method is fast and efficient so that the ester hydrolysis, combination of ester hydrolysis and oxidative defluorination, combination of ester hydrolysis and hydroxylation on pentyl chain moiety and combination of ester hydrolysis and hydroxylation on indazole ring moiety metabolites of 5F-AMB can be used as the suitable and potential biomarkers in the urine samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA