RESUMO
Objective:To evaluate a novel distraction reductor in the surgical treatment of unstable distal radius fractures with metaphyseal volar comminution.Methods:From January 2019 to December 2020, 27 patients with unstable distal radius fracture complicated with metaphyseal volar comminution were treated at Department of Orthopaedics, Zhoupu Hospital Affiliated to Shanghai University of Medicine & Health Sciences. They were 6 males and 21 females, with an age of (69.4±9.4) years. All fractures were unilateral and closed, involving the right side in 17 cases and the left side in 10 cases. All patients were treated by internal fixation with an anatomical locking plate through the volar approach and the novel distraction reductor was used to reduce the fracture ends. Regular imaging examinations were performed to evaluate the reduction, maintenance and union of fractures after surgery. One year after operation, the curative efficacy was assessed by evaluation of the range of wrist motion, Disabilities of the Arm, Shoulder and Hand (DASH) score, Gartland-Werley score and Bartra radiology score.Results:All the operations went on successfully with a duration of (92.3±8.9) min. All the incisions healed primarily. The follow-up time was (15.9±2.9) months. The radial height, palmar tilt, ulnar inclination and articular surface step-off immediately after operation [(11.23±1.51) mm, 12.10°±3.44°, 20.54°±3.44°, and (0.95±0.42) mm] were not significantly lost compared with those one year after operation [(11.22±1.55) mm, 12.07°±3.44°, 20.51°±3.33°, and (0.93±0.40) mm] (all P>0.05). One year after operation, the range of wrist motion was good with dorsiflexion of 59.7°±5.5°, palm flexion of 63.0°±9.1°, pronation of 66.5°±5.5°, supination of 61.2°±5.6°, radial deviation of 22.7°±4.8°, and ulnar deviation of 30.3°±6.1°; DASH score was 13.5±5.5; Bartra radiology score was 88.6±6.5, giving an excellent and good rate of 88.9% (24/27);Gartland-Werley score was 2.7±2.1, giving an excellent and good rate of 92.6% (25/27). Follow-ups observed no poor fracture healing, internal fixation failure, tendon or nerve injury or traumatic arthritis. Conclusion:In the surgical treatment of unstable distal radius fractures with metaphyseal volar comminution, the novel distraction reductor can lead to ideal reduction of displaced fractures and effectively correct the shortening caused by volar cortex comminution to achieve satisfactory functional effects in clinic.