RESUMO
ABSTRACT Aging and face sagging have many causes, and various techniques are used for treatment, including noninvasive procedures, such as focused ultrasound, which uses the principle of collagen regeneration by coagulative necrosis of the dermis layers using radiofrequency, but this procedure has complications. We reported a case of a 54-year-old female patient who complained of poor visual acuity in her right eye three days after a focused ultrasound facial aesthetic procedure, with the best visual acuity of 20/60. Biomicroscopy of the right eye revealed an acute cataract with three points of fibrosis extending from the posterior to the anterior capsule. The patient underwent phacoemulsification surgery with visual rehabilitation and improved vision of 20/20. We hypothesized that the occurrence of acute cataract was related to the inappropriate use of focused ultrasound.
RESUMO
Flanged intrascleral intraocular lens implantation has become one of the mainstream treatment solutions for aphakia in clinical practice due to its ability to avoid dislocation of the intraocular lens,or subluxation caused by suture degradation or breakage,as well as the ability to eliminate complications such as inflammation or infection caused by su-tures,and the significant improvement in postoperative vision for patients.However,there has been no systematic analysis of the factors that may lead to postoperative refractive prediction errors in China.This article analyzes the possible prob-lems of flanged intrascleral intraocular lens implantation and the reasons for postoperative refractive prediction errors,in order to provide reference for clinical work.
RESUMO
AIM: To investigate the effect of different lens combinations on visual acuity, visual quality and patient satisfaction by comparing mixed implantation of Tecnis Symfony ZXR00(ZXR00)and Tecnis ZMB00(ZMB00)lenses, bilateral implantation of ZMB00 lenses, and bilateral implantation of ZXR00 lenses.METHODS:This retrospective case-control study included 117 patients with cataracts(234 eyes)who underwent phacoemulsification combined with intraocular lens(IOLs)implantation from August 2020 to December 2021. The 3 groups included 36 patients(72 eyes)who underwent bilateral implantation of ZXR00(RR group), 37 patients(74 eyes)who underwent bilateral implantation of ZMB00(MM group), and 44 patients(88 eyes)who underwent implantation with a combination of ZXR00 and ZMB00(MR group). The uncorrected distance visual acuity(UDVA, 5 m), uncorrected intermediate visual acuity(UIVA, 80 cm), uncorrected near visual acuity(UNVA, 40 cm), corrected distance visual acuity(CDVA), defocus curve, stereopsis and VF-14 and QoV visual quality scale of the patients in the three groups were assessed at 3-month follow-up.RESULTS:Bilateral UNVA in the MM and MR group were significantly better than that in the RR group(P<0.05). Bilateral UIVA was the best in the RR group. There were no significant differences in bilateral UDVA, CDVA and stereopsis among the groups(P>0.05). Values for near-stereoscopic acuity at 40 cm were 107.27±80.53, 105.67±83.79, and 108.69±97.66(20-400)arcsec in the MR, MM, and RR groups, respectively(P>0.05). Satisfaction rates exceeded 90% in all groups.CONCLUSION:All groups achieved good distance, intermediate, and near visual acuity and near-stereoscopic vision postoperatively. Mixed implantation with ZXR00 and ZMB00 lenses achieved excellent full-range vision and resulted in high satisfaction. These results may aid in developing individualized clinical treatment plans.
RESUMO
AIM: To evaluate the efficacy of phacoemulsification with intraocular lens implantation(PEI)combined with goniosynechialysis(GSL)and goniotomy(GT)under direct vision with gonioscope in the treatment of advanced primary angle-closure glaucoma(PACG)combined with cataract.METHODS: Retrospective case series study. A total of 62 patients(65 eyes)with advanced PACG combined with cataract who were treated in the Second Hospital of Anhui Medical University from December 1, 2021 to March 31, 2023 were enrolled, and they were divided into two groups according to different surgical methods. The control group(32 cases, 33 eyes)received PEI+GSL, whereas the observation group(30 cases, 32 eyes)received PEI+GSL+GT. The intraocular pressure(IOP), best corrected visual acuity(BCVA)and the number of anti-glaucoma medications of the two groups before surgery and at 1 d, 1 wk, 1, 3, and 6 mo after surgery were evaluated. In addition, the visual field, cup-to-disc ratio(C/D), angle open range, anterior chamber depth, and average thickness of retinal nerve fiber layer(RNFL)were evaluated before and 6 mo after surgery.RESULTS: There were significant differences in IOP and lowering range of average IOP at 6 mo between the PEI+GSL+GT group(16.68±2.65, 11.12±8.53 mmHg)and the PEI+GSL group(18.71±2.51, 8.32±4.17 mmHg; P<0.05), and there was no difference in the rate of IOP reduction(44.57%±21.79% and 35.20%±17.94%, P>0.05). The number of anti-glaucoma medications, BCVA, anterior chamber depth, and angle closure range were improved in the two groups at 6 mo after operation(all P<0.01). The number of medication reductions and the range of angle opening at 6 mo after surgery in the PEI+GSL+GT group were significantly higher than those in the PEI+GSL group(P<0.05), and there was no difference in the other indicators between the two groups(all P>0.05). There was no difference in the mean deviation of visual field, C/D and average thickness of RNFL between the two groups at 6 mo after operation compared with those before operation(all P>0.05). The complete surgery success rate of the PEI+GSL+GT group was 81%(26/32), and the conditional success rate was 94%(30/32); while those rates of the PEI+GSL group were 58%(19/33)and 76%(25/33), respectively. There were statistical significance in the success rate of surgery between the two groups(complete success rate χ2=4.275, P=0.039; conditional success rate χ2=4.040, P=0.044). No vision-threatening complications and another surgery occurred in either group.CONCLUSION: The study showed that for patients with advanced PACG with cataract, PEI+GSL+GT is more effective than PEI+GSL.
RESUMO
AIM: To evaluate the diopter errors and safety of secondary intraocular lens(IOL)implantation in the ciliary sulcus using a modified incision procedure in children with bilateral aphakia.METHODS: The data of 12 children(24 eyes)with bilateral aphakia who had undergone secondary foldable IOL implantation in the ciliary sulcus using a modified incision procedure from 2020 to 2021 were retrospectively reviewed. Incision-related complications were analyzed intraoperatively and at 1 d and 1 mo postoperatively. Best-corrected visual acuity(BCVA), axial length(AL), white-to-white(WTW), and refractive outcomes in terms of preoperative reserved diopters(PRD)and actual equivalent spherical diopters(AESD). The patients were divided into two groups by age(≤7 and >7 a), AL(<23 and ≥23 mm)and WTW(≤11.5 and >11.5mm), and the diopter errors between their AESD and PRD predicted based on the measurement results were compared.RESULTS: The patients comprised 9(75%)boys and 3(25%)girls. Two(17%)patients had anterior subcapsular cataracts, 4(33%)had posterior polar cataracts, and 6(50%)had nuclear cataracts. The mean age at cataract extraction was 6.4±1.61(3.4-8.9)mo. The mean interval between cataract extraction and secondary IOL implantation was 6.8±1.82(4.4-11.5)a. The mean preoperative BCVA was 0.49±0.33(1.0-0.1)LogMAR. The mean postoperative BCVA was 0.38±0.32(1.0-0.0)LogMAR. The mean AL was 23.56±1.96(19.00-26.38)mm, and the mean WTW was 11.5±0.92(9.3-13.9)mm. The mean PRD was 1.57±0.60(0.73-2.77)D, the mean AESD was 0.57±0.55(-0.50 to 1.75)D, and the mean difference between the AESD and PRD was -0.99±0.52(-2.22 to 0.32)D. The differences in the AESD and PRD between the groups according to age, AL and WTW were not statistically significant(P=0.59, 0.56, and 0.53, respectively).CONCLUSION: IOL implantation in the ciliary sulcus after a modified incision is safe and feasible for children with aphakia. It is necessary to subtract approximately 1 D of IOL power from the formula-selected power when implanting an IOL in the ciliary sulcus. Age, AL, and WTW do not significantly affect the difference.
RESUMO
Keratoconus is a chronic non-inflammatory corneal disease characterized by thinning and localized protrusion of the corneal stroma in a conical shape. It often leads to irreversible irregular astigmatism and varying degrees of decline in corrected visual acuity. With the rise of femtosecond laser refractive surgery, corneal lenses were discovered as a good biological material. Corneal lens implantation of the cornea can increase the thickness of the cornea and delay the progression of keratoconus disease for further treatment. Currently, convex lenses obtained from myopic small incision lenticule extraction(SMILE)surgery and concave lenses obtained from farsighted SMILE surgery, as well as parallel lenses obtained from donors, can be implanted into the cornea with the aid of femtosecond lasers as lens materials. This article will summarize and discuss the above three lens material implantation methods to provide reference for the selection of keratoconus treatment.
RESUMO
AIM: To observe the efficacy of phacoemulsification combined with capsular tension ring and intraocular lens implantation in the treatment of high myopia with cataract.METHODS: Retrospective study. A total of 82 cases(82 eyes)of high myopia complicated with cataract who admitted to the cataract department of our hospital from December 2021 to April 2023 were selected as study objects, and they were divided into control group(n=39)and combination group(n=43)according to whether or not the capsular tension ring was used intraoperatively. Patients in the control group were treated with intraocular lens implantation alone, and those in the combination group were treated with phacoemulsification combined with capsular tension ring and intraocular lens implantation. The preoperative and postoperative best corrected visual acuity, central anterior chamber depth, trabecular ciliary process, visual quality and complications were compared.RESULTS: At 1 mo after surgery, the best corrected visual acuity(LogMAR)of both groups increased significantly(combination group: 0.64±0.28 vs 0.12±0.14; control group: 0.62±0.26 vs 0.23±0.25, both P<0.001). Central anterior chamber depth in both groups were higher than those before surgery(combination group: 2.57±0.56 vs 1.97±0.40 mm; control group: 2.22±0.45 vs 1.89±0.37 mm; both P<0.001), and the best corrected visual acuity and central anterior chamber depth of the combination group were significantly better than those of the control group(both P<0.05). The distance of trabecular ciliary process showed no statistical significance(combination group: 0.68±0.22 vs 0.74±0.20 mm; control group: 0.74±0.19 vs 0.78±0.17 mm, both P>0.05). The visual quality scores of the combination group were all higher than the control group at 1 mo after surgery [watching TV: 3.00±0.38 vs 2.22±0.46 points; reading books: 2.85±0.42 vs 2.21±0.44 points; night vision: 2.71±0.34 vs 2.37±0.41 points; fine operation: 2.82±0.38 vs 2.33±0.40 points, all P<0.001]. The incidence of complication in the combination group was significantly lower than that of the control group(33% vs 14%, P<0.05).CONCLUSION: Phacoemulsification combined with capsular tension ring and intraocular lens implantation can effectively promote the recovery of visual function, improve the structure of chamber angle, and reduce the incidence of complications in the treatment of patients with high myopia and cataract.
RESUMO
AIM: To explore the effects of femtosecond laser-assisted cataract surgery combined with intraocular lens implantation(FLACS-IOL)on postoperative deviation rate of multifocal intraocular lens(MIOL)and visual quality in cataract patients.METHODS: In the prospective study, 95 patients with cataract(108 eyes)who underwent MIOL implantation in the hospital between January 2021 and December 2022 were enrolled. According to different surgical methods, they were divided into FLACS group(51 cases, 56 eyes)and Phaco group(44 cases, 52 eyes). The operation time, incision diameter of anterior capsule, effective phaco time(EPT), cumulative dissipated energy(CDE), uncorrected distance visual acuity(UCDVA), best corrected distance visual acuity(BCDVA), eccentricity distance of IOL and deviation rate at 3 mo after surgery, total high order aberration(HOA), Trefoil and coma under 3 mm pupil were compared between the two groups.RESULTS: The operation time in the FLACS group was significantly shorter than that in the Phaco group, EPT and CDE were significantly lower than those in the Phaco group(all P<0.05). There was no significant difference in incision diameter of anterior capsule between the two groups(P>0.05). At 1 wk, 3 mo after surgery, UCDVA in the FLACS group was better than that in the Phaco group(all P<0.05). There were significant difference in UCDVA at 1 wk, 3 mo after surgery or BCDVA at 3 mo after surgery between the two groups(P<0.05). At 3 mo after surgery, eccentricity distance of IOL in the FLACS group was shorter than that in the Phaco group, and deviation rate was significantly lower than that in the Phaco group(all P<0.05). Under pupil diameter of 3 mm, HOA, trefoil and coma of whole eyes were decreased in both groups at 3 mo after surgery(P<0.05). At 3 mo after surgery, there were significant differences in HOA and trefoil of whole eyes between the FLACS group and Phaco group(P<0.05), but there was no significant difference in coma at 3 mo after surgery(P>0.05).CONCLUSION: FLACS-IOL can effectively reduce deviation rate of IOL and obtain better visual quality in cataract patients.
RESUMO
ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.
RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.
RESUMO
ABSTRACT We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.
RESUMO
ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.
RESUMO Objetivo: Avaliar os resultados visuais, satisfação e qualidade de vida de pacientes atendidos em um hospital escola pelo Sistema Único de Saúde, submetidos a implante bilateral de lente intraocular multifocal difrativa. Métodos: Estudo tipo série de casos com intervenção, incluindo 20 pacientes submetidos a implante bilateral da lente intraocular multifocal difrativa EyeDiff® (Eyeol UK, Dunstable, UK). Os critérios de exclusão foram astigmatismo corneano >1,5 dioptria cilíndrica, cirurgia ou doença ocular prévias e complicações intraoperatórias ou pós-operatórias. Os pacientes foram avaliados após 1, 3 e 6 meses da cirurgia. Foram avaliadas a acuidade visual monocular e binocular para longe, intermediário e perto sob condições fotópica e mesópica, sensibilidade ao contraste monocular sob condições fotópicas, curva de defocus e questionário para avaliação da qualidade de vida. Resultados: A acuidade visual para longe corrigida monocular foi de 0,3 logMAR ou melhor e a acuidade visual para perto com correção para longe foi J3 ou melhor em todos os olhos, sob condições fotópicas. A acuidade visual binocular para perto com a correção para longe foi J1 em todos os casos. A sensibilidade ao contraste estava no nível mínimo de normalidade para frequências espaciais baixas e altas e abaixo dos limites normais para frequência espacial intermediária. O questionário de qualidade de vida mostrou que os pacientes apresentavam altos níveis de satisfação. Conclusão: O implante bilateral da lente intraocular multifocal EyeDiff® proporcionou boa acuidade visual e qualidade de vida, e independência de óculos aos pacientes. A acuidade visual e a sensibilidade ao contraste melhoraram progressivamente entre um e seis meses de pós-operatório.
RESUMO
We described a modified Yamane technique for simplifying trailing haptic insertion in aphakia correction. In Yamane intrascleral intraocular lens (IOL) implantation technique, trailing haptic implantation is challenging for many surgeons. This modification provides an easier and safer way of trailing haptic insertion into the needle tip and decreases the possibility of bending or breaking the trailing haptic.
RESUMO
Background: Inadequate posterior capsular support during cataract surgery makes it difficult to implant posterior chamber intraocular lens.One of the secondary intraocular lens implantation options is iris claw lens.Retropupillary iris claw lens is preferred than anterior because chances of damage to the anterior chamber angle and iris root are avoided as the lens is fixed to the mid periphery of iris. The prospective study aims to analyse the visual outcomes and immediate postoperative complications after retropupillary iris-claw lens implantation in a tertiary care hospital. Methods: It was a prospective study done conducted on 24 patients with inadequate posterior capsular support in which retropupillary iris-claw lens implantation was done from December 1, 2021 to May 31, 2022 at Government Regional Eye Hospital, Visakhapatnam. Immediate postoperative complications were noted. Final visual outcomes were noted after 2 months. Results: The study comprised of 24 eyes. The mean patient age was 55.91 years (range 44-77 years).The IOLs were inserted during primary lens surgery in 16 eyes (66.6%) and as a secondary procedure in 8 aphakic eyes (33.4%). The mean postoperative intraocular pressure was 15.1 mmHg. Majority of the eyes had best corrected visual acuity of 6/12 (41.6%).The most common immediate postoperative complication was pupil ovalization (25%) and striate keratopathy (25%). Least common complication was choroidal detachment (3.6%). Conclusions: Visual outcomes of primary and secondary iris claw implantation were similar. The retro-pupillary iris-claw lens implantation provided good visual outcome with tolerable complications. It can be used in eyes with inadequate posterior capsular support.
RESUMO
Introduction@#Intraocular lens (IOL) implants are monofocal and trifocal lenses which helps to clear up the vision after cataract surgery.@*Goal@#In this work, we aimed to compare the monofocal and trifocal IOL implantation during phacoemulsification surgery.@*Materials and Methods@#This study was conducted on 133 participants. Females comprised n=81, mean n=52 into equal groups. Preoperative and Postoperative cataract surgery UCVA and BCVA were measured and compared during the after 1 day, week 1, 2 weeks and month1. @*Statistical analysis@#The results of the study were processed using the SPSS 25.0 program after coding the data and checking for typographical errors. The normality of the data distribution was tested by inspecting a histogram. Categorical variables were compared using the chi-square test or Fisher's test. Statistical significance was determined at a p-value lower than 0.05@*Ethical statement@#The study was approved by the Research Ethics Committee of the Mongolian National University of Medical Sciences (No.2021/05/21). All patients provided written informed consent before participating in this study.@*Results@#The mean preoperative UCVA was 1.09±0.45D in monofocal IOL group, 0.99±0.49D in trifocal IOL group. At the first week: The mean postoperative UCVA at one week was 0.34±0.29D and 0.27±0.17D, in each group respectively. The mean postoperative BCVA in the first week was 0.28±0.27D and 0.20±0.15D in each group respectively. The mean postoperative UCVA at 1 month was 0.27±0.24D and 0.15±0.16D in each group, while BCVA was 0.26±24.94D and 0.06±0.63D.There was a highly significant statistical difference between the result of UCVA preoperative and the results of UCVA at the early and last postoperative follow up. @*Conclusion@#From our results, the best corrected visual acuity and was better for Trifocal group than Monofocal group. It is evident that post-operative near UCVA and BCVA was statistically significant at monofocal and trifocal groups.
RESUMO
Corneal refractive surgery and intraocular collamer lens(ICL)implantation are the mainstream refractive surgery methods at present. Many studies have proved that ICL implantation can effectively improve the postoperative visual acuity of patients. ICL implantation has gained favor among refractive doctors and patients because of its multiple advantages. Excellent postoperative visual acuity and visual quality are the key factors to improve patients' satisfaction. In order to evaluate the subjective and objective visual quality of patients after operation and avoid complications, this article reviews the visual quality and postoperative complications after ICL implantation.
RESUMO
Myopia is considered to be a disease occurred under the influence of genetic and environmental factors, and it can only be restored by corrective surgeries. The current surgical methods include laser surgeries and phakic intraocular lens(PIOL)implantation, and PIOL has the advantages of wide range of correction, repeatable procession and small damage to corneal tissue. Furthermore, good visual acuity can be achieved after implantation of intraocular lens. Implantable collamer lens(ICL)is the most common surgical method in this group. The vertical distance between the highest point of the posterior central surface of the implanted lens and the anterior surface of the crystalline lens is called vault. It will cause serious complications if the vault turns out to be abnormal. Up to now, there is no optimal prediction method. This research focuses on vault, discusses the ideal range of postoperative vault, the safety and effectiveness of this surgery, and analyzes the existing prediction methods to provide directions for future clinical research.
RESUMO
Objective:To observe the unfolding status of foldable acrylic intraocular lens (IOL) of different materials, designs and refractive powers implanted in the capsular bag during cataract surgery, and to investigate its influence on the IOL implantation procedure.Methods:An observational case series study was conducted.A total of 1 005 patients who underwent routine phacoemulsification and IOL implantation in Shaanxi Eye Hospital from February to August 2021 were enrolled.The status and unfolding time of the leading haptic, optical region, and trailing haptic of the IOL in the capsular bag and the surgeon were recorded in real-time intraoperative video.Of the 1 005 IOL implants, 681 were hydrophobic, 324 hydrophilic, 733 C-loop, 272 plate-haptic, 909 single-piece, 96 three-piece, 620 preloaded, and 385 non-preloaded.The differences in unconventional implantation factors and IOL unfolding time were compared.The factors influencing IOL implantation status were analyzed by multivariate logistic regression.Multivariate logistic regression was used to analyze the relevant factors affecting IOL implantation status.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Xi'an People's Hospital (Xi'an Fourth Hospital)(No.20200035). Written informed consent was obtained from each subject.Results:There were 14(1.4%) IOLs with unconventional leading haptic status during implantation, including 7 recurved, 4 folded, 2 twisted and 1 straightened.There were 101(10.0%) IOLs with unconventional trailing haptic status during implantation, including 49 stuck in the injector, 40 folded, 10 recurved and 2 broken.There were 22(2.2%) IOLs with overlapped leading and trailing haptic requiring additional separation.There were 4(0.4%) IOLs with reversed optical regions and 2(0.2%) with damaged optical regions.The occurrence rate of unconventional leading haptic status using C-loop IOL was higher than that using plate IOL, and the difference was statistically significant ( P<0.05). The occurrence rate of unconventional trailing haptic status using hydrophilic, non-preloaded, three-piece, and C-loop IOL was higher than that using hydrophobic, preloaded, single-piece, and plate IOL, respectively, and the differences were statistically significant ( χ2=9.100, 61.400, 81.885, 7.587; all at P<0.05). The 22(2.2%) IOLs with overlapped leading and trailing haptic were hydrophobic.The 4 (0.4%) IOLs with reversed optical region were non-preloaded.The results of multivariate logistic regression analysis showed that IOL material, loading method, design and surgeons were related to the unconventional trailing haptic status in implantation ( OR=9.894, 3.720, 6.810, 1.338; all at P<0.05). The average unfolding time of hydrophobic IOL was 26.12(21.21, 30.91)s, which was significantly longer than 3.03(2.16, 4.49)s of hydrophilic IOL ( Z=-25.603, P<0.05). The average unfolding time of C-loop IOL was 25.53(19.41, 30.25)s, which was significantly longer than 2.70(2.08, 3.69) s of plate IOL ( Z=-23.764, P<0.05). Conclusions:A variety of unconventional statuses of IOL can occur during implantation into the lens capsular bag.The use of hydrophobic, preloaded, single-piece, and plate IOLs can reduce the occurrence of unconventional status.The use of hydrophilic IOLs can reduce the overlap of leading and trailing haptic.The use of preloaded IOLs can reduce the occurrence of IOL optical region reversal.The use of hydrophilic and plate IOLs can shorten the operation time.
RESUMO
Cataract extraction is often combined with the implantation of intraocular lens (IOL) with the diopter matching the operated eye to restore optimal visual function after surgery.However, there are often errors between the actual refractive power of the operated eye and the predicted value.One of the major causes of postoperative refractive error is the change in IOL position compared with the expected position.In order to improve the accuracy of postoperative refraction prediction, Holladay proposed to introduce the concept of effective lens position (ELP) into the IOL diopter calculation formula.The differences in the parameters and algorithms incorporated in the calculation of ELP lead to differences in the accuracy of IOL calculation formulas.With the application of multi-parameter calculation methods, especially the formula based on the artificial intelligence algorithm, the accuracy of IOL calculation formula has been significantly improved.ELP is also affected by various factors such as differences in ocular anatomy, IOL design and material, and surgical procedures, especially the factors affecting the stability of the capsular bag that increase the difficulty of accurately predicting ELP.Therefore, the changes in postoperative ELP need to be further discussed in order to obtain more accurate postoperative refraction.This article aimed to give a review of the development of calculation formulas and the influencing factors of ELP.
RESUMO
ABSTRACT A 38-year-old patient who developed aphakia and aniridia secondary to trauma suffered from vision loss. To improve her vision, an iris-intraocular lens complex (Reper®) was fixed to the sclera with Canabrava's double-flanged technique. There was a satisfactory increase in the patient's visual acuity and no complications were observed during the 6-months follow-up. Canabrava technique simplifies and improves the fixation of the iris-intraocular lens complex to the sclera. It is a safe option that does not require scleral flaps or knots.
RESUMO Uma paciente de 38 anos desenvolveu afacia e aniridia secundárias a um trauma, levando à perda da visão. Para melhorar sua visão, um complexo de íris e lente intraocular (Reper®) foi fixado à esclera com a técnica de flange duplo de Canabrava. Houve um aumento satisfatório na acuidade visual do paciente e nenhuma complicação foi observada durante o acompanhamento de 6 meses. A técnica de Canabrava simplifica e melhora a fixação do complexo de íris e lente intraocular na esclera. É uma opção segura que não requer retalhos ou pontos esclerais.
RESUMO
AIM:To observe the early variation trend of the vault after phakic posterior chamber implantable collamer lens/toric implantable collamer lens(ICL/TICL V4c)implantation and analyze the related influencing factors.METHODS:In this retrospective study, a total of 49 patients(98 eyes)who underwent ICL/TICL V4c implantation in the Lanzhou Huaxia Eye Hospital from October 2020 to March 2021 were enrolled. Preoperative ocular biometric parameters were collected, including spherical equivalent(SE), intraocular pressure, axial length, anterior chamber depth(ACD), lens thickness(LT), central corneal thickness, anterior chamber angle(ACA), anterior chamber volume(ACV), white to white corneal diameter(WTW), mean keratometry K1 and K2, and intraoperative implantation size of ICL. The vault was measured by anterior segment optical coherence tomography(AS-OCT)at 1, 3d, 1wk and 1mo after surgery. The patients were divided into insufficient vault group(<250μm, 12 eyes), normal vault group(250-750μm, 62 eyes)and excessive vault group(>750μm, 24 eyes)according to the vault at 1mo after surgery. The factors affecting the postoperative vault were analyzed.RESULTS:The mean vault values at 1 and 3d, 1wk and 1mo after surgery were 591.05±293.44, 599.62±309.78, 592.22±301.49 and 586.69±285.63μm, respectively. There were significant differences in WTW, ACA, ACV, ACD, ICL size and LT at 1mo after surgery(all P<0.05). The regression equation of vault at 1mo after surgery was as follows: vault(μm)=-3142.19+388.25×WTW+10.40×ACA-301.63×LT(R=0.674, R2=0.454, adjusted R2=0.436). WTW had the greatest influence on vault at 1mo after surgery(β=0.47, P<0.001), followed by LT(β=-0.34, P<0.001)and ACA(β=0.17, P=0.047).CONCLUSION:WTW, ACA and LT were the main factors that affected and predicted the vault at 1mo after ICL/TICL V4c implantation.