Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1023054

RESUMO

Objective:To investigate the value of ultrasonic measurement of the ratio of optic nerve sheath diameter (ONSD) to eyeball transverse diameter(ETD) in the diagnosis and prognosis of intracranial hypertension in patients with craniocerebral trauma.Methods:A total of 120 patients with craniocerebral trauma treated in the Xingtai General Hospital of North China Medical and Health Group from December 2021 to January 2023 were perspectively selected, and they were divided into normal intracranial pressure group (73 cases) and intracranial hypertension group (47 cases) according to the results of intracranial pressure measurements, and the intracranial hypertension group was divided into good prognosis group (20 cases) and poor prognosis group (27 cases) according to the follow-up prognosis. The efficacy of ONSD, ETD and ONSD/ETD in intracranial hypertension diagnosis and prognosis assessment were analyzed by receiver operating characteristic (ROC) curve. Kaplan-Meier method was used to evaluate the 6-month risk of adverse prognosis of patients, and the comparison was made by Log-rank test.Results:The levels of intracranial pressure, ONSD, ONSD/ETD in the normal intracranial pressure group were lower than those in the intracranial hypertension group: (130.73 ± 23.63) mmH 2O (1 mmH 2O = 0.009 8 kPa) vs. (270.11 ± 35.78) mmH 2O, (5.47 ± 0.29) mm vs. (5.78 ± 0.44) mm, 0.246 ± 0.018 vs. 0.263 ± 0.018, there were statistical differences ( P<0.05). The scores of Glasgow Coma Scale (GCS), intracranial pressure, ONSD, ONSD/ETD in the good prognosis group were lower than those in the poor prognosis group: (5.50 ± 1.24) scores vs. (6.41 ± 1.34) scores, (256.15 ± 30.23) mmH 2O vs. (280.44 ± 36.56) mmH 2O, (5.62 ± 0.40) mm vs. (5.90 ± 0.44) mm, 0.254 ± 0.014 vs. 0.270 ± 0.017, there were statistical differences ( P<0.05). ROC curve analysis results showed that the area under the curve (AUC) of ONSD and ONSD/ETD for diagnosing intracranial hypertension in patients with craniocerebral trauma were 0.718 and 0.765, respectively, and the critical values were 5.87 mm and 0.263, respectively. The AUC of ONSD and ONSD/ETD predicting prognosis of intracranial hypertension patients was 0.677 and 0.763, respectively, and the critical values were 5.90 mm and 0.267, respectively. Grouped by the threshold of ONSD/ETD for the prognosis of intracranial hypertension (0.267), the incidence of adverse prognosis in ONSD/ETD > 0.267 group was higher than that in the ONSD/ETD≤0.267 group, there was statistical difference ( P<0.05). Conclusions:ONSD/ETD can be used as an index for diagnosis and prognosis of intracranial hypertension.

2.
Chongqing Medicine ; (36): 592-596,602, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1017504

RESUMO

Objective To explore the application value of ultrasonic measurement of optic nerve sheath diameter(ONSD)and cerebral blood flow parameters in intracranial hypertension caused by AIDS cryptococ-cal meningitis.Methods A total of 27 patients with cryptococcal meningitis diagnosed by Chongqing Public Health Medical Center from February to July,2022 were included.All patients were examined with ultrasound measurement of ONSD and ultrasound measurement of cerebral blood flow of intracranial middle cerebral ar-tery(MCA),including peak systolic velocity(PSV),end diastolic velocity(EDV),peak systolic velocity/end diastolic velocity(S/D)and resistance index(RI),and then lumbar puncture was performed and intracranial pressure(ICP)was recorded.The ICP≥200 mmH2O was defined as the ICP increased group,ICP<200 mmH2O was defined as the ICP normal group,and 17 AIDS patients without complications were selected as the control group.The baseline data,ONSD and MCA cerebral blood flow parameters of the three groups were compared,and the statistically significant indexes were correlated with ICP,and the receiver operating charac-teristic(ROC)curve of the subjects was drawn to analyze the diagnostic efficacy of ONSD value in predicting intracranial hypertension caused by AIDS cryptococcal meningitis.Results There were no significant differ-ences in gender,age,systolic blood pressure or diastolic blood pressure among the ICP increased group,the ICP normal group and the control group(P>0.05).There were no significant differences in PSV,EDV,S/D and RI among the three groups of MCA(P>0.05),but there was significant difference in ONSD among the three groups(P<0.05).There was a positive correlation between ICP and ONSD in the patients with AIDS cryptococcal meningitis(P<0.01,r=0.736).The ROC curve analysis showed that when the ONSD cutoff value was 3.965 mm,it predicted the highest efficacy of intracranial high pressure in the patients with AIDS cryptococcal meningitis.The area under the ROC curve was 0.90(95%CI:0.714-1.000,P=0.001),the sensitivity was 90%,and the specificity was 100%.Conclusion Ultrasonic measurement of ONSD can effec-tively predict ICP in patients with AIDS cryptococcal meningitis and guide clinical decompression measures in time,which is worthy of clinical application.

3.
Braz. J. Anesth. (Impr.) ; 73(6): 769-774, Nov.Dec. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1520374

RESUMO

Abstract Background: Positive end-expiratory pressure (PEEP) can overcome respiratory changes that occur during pneumoperitoneum application in laparoscopic procedures, but it can also increase intracranial pressure. We investigated PEEP vs. no PEEP application on ultrasound measurement of optic nerve sheath diameter (indirect measure of increased intracranial pressure) in laparoscopic cholecystectomy. Methods: Eighty ASA I-II patients aged between 18 and 60 years scheduled for elective laparoscopic cholecystectomy were included. The study was registered in the Australian New Zealand Clinical Trials (ACTRN12618000771257). Patients were randomly divided into either Group C (control, PEEP not applied), or Group P (PEEP applied at 10 cmH20). Optic nerve sheath diameter, hemodynamic, and respiratory parameters were recorded at six different time points. Ocular ultrasonography was used to measure optic nerve sheath diameter. Results: Peak pressure (PPeak) values were significantly higher in Group P after application of PEEP (p = 0.012). Mean respiratory rate was higher in Group C at all time points after application of pneumoperitoneum (p < 0.05). The mean values of optic nerve sheath diameters measured at all time points were similar between the groups (p > 0.05). The pulmonary dynamic compliance value was significantly higher in group P as long as PEEP was applied (p = 0.001). Conclusions: During laparoscopic cholecystectomy, application of 10 cmH2O PEEP did not induce a significant change in optic nerve sheath diameter (indirect indicator of intracranial pressure) compared to no PEEP application. It would appear that PEEP can be used safely to correct


Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Pneumoperitônio , Colecistectomia Laparoscópica , Nervo Óptico/diagnóstico por imagem , Austrália , Pressão Intracraniana , Respiração com Pressão Positiva/métodos
4.
Artigo em Chinês | WPRIM | ID: wpr-1027132

RESUMO

Objective:To investigate the diagnostic value of ultrasonic measurement of optic nerve sheath diameter (ONSD) and optical disk elevation (ODE) for intracranial hypertension in patients with cerebral venous sinus thrombosis(CVST).Methods:A total of 50 patients with CVST who underwent lumbar puncture and ONSD examination in the Department of Neurology and Emergency Department of Xuanwu Hospital, Capital Medical University from January 2021 to December 2021 were retrospectively enrolled. After lumbar puncture, the patient′s initial intracranial pressure was recorded. Normal ICP was defined as ICP between 80 and 200 mmH 2O, and increased ICP was defined as ICP>200 mmH 2O. Fifty patients with CVST were divided into normal ICP group (14 cases) and increased ICP group (36 cases). The differences of baseline data, ONSD and ODE between the two groups were compared, and the receiver operating characteristic (ROC) curve was generated. The area under the curve (AUC) and the diagnostic cut-off value of ONSD were analyzed. Spearman correlation analysis was used to analyze the correlation between ONSD, ODE, CVST involvement range scores and intracranial pressure. Results:①There were no significant differences in gender, age and body mass index between the normal ICP group and the increased ICP group (all P>0.05). ②The ONSD and ODE in the increased ICP group were higher than those in the normal ICP group, and the differences were statistically significant [(4.83±0.33)mm vs (4.21±0.21)mm, (0.67±0.44)mm vs (0.24±0.29)mm, all P<0.001]. Spearman correlation analysis showed that ONSD and ODE were positively correlated with intracranial pressure ( rs=0.74, 0.51, all P<0.001). ③The extent of CVST involvement in the intracranial hypertension group was higher than that in the normal intracranial pressure group, and the difference was statistically significant [5.0(3.0, 7.5) vs 2.5(2.0, 5.0), P=0.015]. Spearman correlation analysis showed that CVST involvement score was positively correlated with intracranial pressure ( rs=0.43, P<0.001). ④In the diagnosis of intracranial hypertension in patients with cerebral venous sinus thrombosis, the AUC of ONSD was 0.935, the best diagnostic threshold of ONSD was 4.5 mm, the sensitivity was 0.81, and the specificity was 0.93. Conclusions:ONSD and ODE measured by ultrasound are reliable imaging methods to identify intracranial hypertension in patients with CVST.

5.
Artigo em Chinês | WPRIM | ID: wpr-1018131

RESUMO

Objective:To evaluate the effects of intrathecal infusion chemotherapy on intracranial pressure (ICP) in non-small cell lung cancer (NSCLC) patients with leptomeningeal metastases (LM) by ultrasound measurement of the optic nerve beside the bed of optic nerve sheath diameter (ONSD) .Methods:A total of 31 NSCLC-LM patients who underwent intrathecal infusion chemotherapy at Nanjing Drum Tower Hospital, Affiliated Hospital of Nanjing University Medical School from June 10, 2021 to December 25, 2022 were collected. The ONSD values were measured before and after the first lumbar puncture by bedside optic nerve ultrasound, and measured dynamically 30 min before intrathecal infusion chemotherapy (T0) , 30 min (T1) , 1 h (T2) , 2 h (T3) , 4 h (T4) , 6 h (T5) , and 24 h (T6) after intrathecal infusion chemotherapy. ICP ONSD was calculated, with differences between ICP LP and ICP ONSD, and differences between ONSD and ICP ONSD series at different time being compared separately. Mean arterial pressure (MAP) , heart rate, and headache score were assessed and compared respectively at T0, T1, T2, T3, T4, T5 and T6. Spearman analysis was used to evaluate the correlation between the response assessment in neuro-oncology (RANO) score and ICP. Results:Before the first lumbar puncture for cerebrospinal fluid drainage, ICP LP was (218.55±63.83) mmH 2O, left eye, right eye, and binocular eyes ICP ONSD were (217.28±57.17) mmH 2O, (223.64±51.13) mmH 2O, and (220.46±52.50) mmH 2O respectively, in NSCLC-LM patients, with no statistically significant difference ( F=0.77, P=0.463) . After first lumbar puncture for cerebrospinal fluid drainage, ICP LP was (214.68±58.01) mmH 2O, left eye, right eye, and binocular eyes ICP ONSD were (216.71±48.96) mmH 2O, (216.62±47.18) mmH 2O, and (216.67±47.86) mmH 2O respectively, with no statistically significant difference ( F=0.12, P=0.757) . At T0, T1, T2, T3, T4, T5, and T6, the MAP during intrathecal infusion chemotherapy was 89.80 (83.40, 93.67) mmHg, 95.00 (80.83, 99.37) mmHg, 91.86 (79.88, 100.14) mmHg, 90.15 (79.04, 100.55) mmHg, 105.14 (88.55, 114.74) mmHg, 98.96 (81.72, 111.81) mmHg, and 89.29 (85.45, 100.38) mmHg, with a statistically significant difference ( χ2=16.11, P=0.013) ; heart rates were 80.00 (75.00, 84.50) times/min, 80.00 (72.50, 87.50) times/min, 74.00 (66.00, 87.50) times/min, 82.00 (72.00, 90.00) times/min, 80.00 (70.50, 90.00) times/min, 77.00 (68.00, 91.00) times/min, 77.00 (71.50, 88.50) times/min, with no statistically significant difference ( χ2=2.18, P=0.902) ; headache scores were 2.00 (0.50, 3.00) score, 2.00 (1.00, 3.00) score, 2.00 (2.00, 3.00) score, 2.00 (1.00, 3.00) score, 2.00 (1.00, 2.00) score, 2.00 (1.00, 2.00) score, and 2.00 (0.00, 2.00) score, with no statistically significant difference ( χ2=11.64, P=0.071) . At T0, T1, T2, T3, T4, T5, and T6, left eye, right eye, and binocular ONSD were (5.85±0.64) mm, (5.72±0.68) mm, (7.11±1.11) mm, (6.42±0.78) mm, (5.69±0.63) mm, (5.61±0.64) mm, (5.65±0.88) mm, (5.85±0.12) mm, (5.89±0.12) mm, (6.93±0.20) mm, (6.40±0.14) mm, (5.71±0.12) mm, (5.66±0.12) mm, (5.33±0.14) mm, (5.85±0.64) mm, (5.81±0.64) mm, (7.02±1.03) mm, (6.41±0.75) mm, (5.70±0.63) mm, (5.64±0.63) mm, (5.49±0.76) mm, with statistically significant differences ( F=58.48, P<0.001; F=49.34, P<0.001; F=78.05, P<0.001) ; ICP ONSD were (222.81±56.81) mmH 2O, (211.89±60.29) mmH 2O, (335.12±98.32) mmH 2O, (274.17±68.87) mmH 2O, (208.77±56.12) mmH 2O, (201.75±56.79) mmH 2O, (205.59±78.36) mmH 2O, (223.26±58.33) mmH 2O, (227.08±61.68) mmH 2O, (319.36±101.10) mmH 2O, (272.33±69.61) mmH 2O, (211.21±57.73) mmH 2O, (206.51±57.22) mmH 2O, (177.22±68.98) mmH 2O, (223.03±57.24) mmH 2O, (219.49±57.24) mmH 2O, (327.24±91.56) mmH 2O, (273.25±67.04) mmH 2O, (209.99±56.26) mmH 2O, (204.13±56.29) mmH 2O, (191.40±67.95) mmH 2O, with statistically significant differences ( F=58.48, P<0.001; F=49.34, P<0.001; F=78.13, P<0.001) . The ONSD of the left eye, right eye, and binocular eyes and the corresponding ICP ONSD increased significantly at T2 compared with T0, T1, T3, T4, T5, and T6, with statistically significant differences (all P<0.05) . Pre- and post-treatment RANO scores were 4.00 (3.00, 7.00) score and 3.00 (2.00, 6.00) score respectively. Pre- and post-treatment RANO scores were positively correlated with ICP ONSD in the left eye ( r=0.55, P=0.001; r=0.60, P<0.001) , right eye ( r=0.54, P=0.001; r=0.46, P=0.009) and binocular eyes ICP ONSD ( r=0.45, P=0.010; r=0.37, P=0.043) . Conclusion:Intrathecal infusion chemotherapy for NSCLC-LM patients can cause a transient increase in ONSD and ICP, with the greatest effect at 1 hour after intrathecal infusion chemotherapy. RANO score is positively correlated with ICP ONSD before and after treatment, which can provide an important reference for evaluating the efficacy of intrathecal infusion chemotherapy.

6.
Artigo em Chinês | WPRIM | ID: wpr-1018908

RESUMO

Objective:To explore the predictive value of bedside ultrasound monitoring of optic nerve sheath diameter (ONSD) for short-term neurological prognosis in critically ill patients without primary brain injury.Methods:An observational prospective study was conducted to enroll critically ill patients without primary brain injury admitted to the emergency intensive care unit (ICU) of Cangzhou Central Hospital from January 2021 to April 2022. The exclusion criteria were as follows: age < 18, combined ocular and optic nerve pathology or injuries, impaired consciousness due to prior neuropathy, primary brain injury, ICU stay < 3 days, death or loss of follow-up within 28 days. Bedside ultrasound measurements of ONSD were performed within 24 hours of ICU admission and on day 3 of ICU admission. The consciousness status was assessed daily during ICU hospitalization. If the Glasgow Coma Scale (GCS) is 15 and the confusion assessment method intensive care unit (CAM-ICU) is negative, the consciousness status will be defined as nonconsciousness disorder. While if the GCS score is less than 15 or the CAM-ICU is positive, the consciousness status will be defined as consciousness disorder. According to the status of consciousness at 28 days, patients were divided into a nonconscious disorder group and a conscious disorder group, and the difference in each index was compared between the two groups. Univariate and multivariate Cox regression were used to analyze the factors influencing 28-day neurological function prognosis, and a Kaplan?Meier survival curve was plotted to analyze the relationship between ONSD and 28-day neurological function prognosis.Results:Sixty-one critically ill patients without primary brain injury (48 in the nonconscious disorder group and 13 in the conscious disorder group) were recruited. Compared to patients in the unconscious disorder group, those in the conscious disorder group had lower GCS upon ICU admission [7(4, 8) vs. 8(6, 14), P<0.05], longer length of mechanical ventilation (MV) [28(15, 28) days vs. 10(4, 14) days, P<0.001], and longer length of ICU stay [28(28, 28) days vs. 12(7, 20) days, P<0.001]. Patients in the conscious disorder group had a higher ONSD within 24 hours of ICU admission [(5.75±0.53) mm vs. (5.45±0.60) mm, P=0.114] and a higher ONSD 3 days after ICU admission [(5.54±0.64) mm vs. (5.22±0.65) mm, P=0.124] than patients in the unconscious disorder group, but the differences were not statistically significant. Multivariate Cox regression analysis showed that use of MV, GCS upon ICU admission and ONSD on day 3 of ICU admission were independent risk factors. Kaplan?Meier survival analysis showed that patients with an ONSD < 5.30 mm on day 3 had a better 28-day neurological prognosis. Moreover, among the patients with ONSD within 24 hours ≥5.30 mm, the patients with ONSD decreased to < 5.30 mm on day 3 had significantly better 28-day neurological prognosis than those with ONSD ≥ 5.30 mm on day 3 ( P=0.042). Conclusions:ONSD within 24 hours of ICU admission, especially ONSD levels and changes in ONSD on day 3, had predictive value for the short-term neurological prognosis of critically ill patients without primary brain injury.

7.
Rev. cuba. pediatr ; 94(4)dic. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1441805

RESUMO

Introducción: El traumatismo craneoencefálico es responsable de más de 500 000 visitas a departamentos de urgencias, 95 000 hospitalizaciones y 7 000 muertes en la población infantil. La monitorización clínica se apoya en técnicas imagenológicas, entre otras. Objetivo: Relacionar los hallazgos tomográficos encontrados, a través de la clasificación de Marshall al ingreso y diámetro de la vaina del nervio óptico y su asociación con la presión intracraneal y con los resultados en el paciente pediátrico con traumatismo craneoencefálico grave. Métodos: Estudio descriptivo prospectivo con todos los pacientes pediátricos aquejados de traumatismo craneoencefálico grave entre enero de 2003 y diciembre de 2017. Resultados: De los 41 casos, se encontró relación entre los niveles de presión intracraneal y el grado de luxación de la línea media >10 mm en 10 enfermos (62,5 %) y con el diámetro de la vaina del nervio óptico (>5,5 mm) por tomografía de cráneo en 12 (75,0 %), igualmente existió relación entre esas dos variables con los resultados a los 6 meses de evolución. Conclusiones: La utilización de la tomografía de cráneo simple como herramienta para la determinación de variables utilizadas en el monitoreo no invasivo de la presión intracraneal como son la clasificación tomográfica de Marshall, la luxación de la línea media y la medición del diámetro de la vaina del nervio óptico, permite identificar incrementos de la presión intracraneal. Esto pudiera utilizarse para el tratamiento intensivo de los pacientes pediátricos con traumatismo cráneo encefálico grave, sin necesidad de la utilización de monitoreo invasivo en ellos.


Introduction: Traumatic brain injury is responsible for more than 500,000 visits to the emergency services, 95,000 hospitalizations and 7,000 deaths in children. Clinical monitoring is based on imaging techniques, among others. Objective: To relate the tomographic findings found, through Marshall's classification at the entrance and diameter of the optic nerve sheath and its association with intracranial pressure and with the results in the pediatric patient with severe head trauma. Methods: Prospective descriptive study with all pediatric patients suffering from severe head trauma between January 2003 and December 2017. Results: Of the 41 cases, a relationship was found between the levels of intracranial pressure and the degree of dislocation of the midline >10 mm in 10 patients (62.5%) and with the diameter of the optic nerve sheath (>5.5 mm) by skull tomography in 12 (75.0%); there was also a relationship between these two variables with the results at 6 months of evolution. Conclusions: The use of simple tomography of the skull as a tool for the determination of variables used in the non-invasive monitoring of intracranial pressure such as Marshall tomographic classification, midline dislocation and measurement of the diameter of the optic nerve sheath, allows to identify increases in intracranial pressure. This could be used for the intensive treatment of pediatric patients with severe head trauma, without the need for invasive monitoring in them.

8.
Rev. medica electron ; 44(4): 739-747, jul.-ago. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1409760

RESUMO

RESUMEN La ultrasonografía del diámetro de la vaina del nervio óptico es un método no invasivo para monitorizar la presión intracraneal. Se ha utilizado en múltiples patologías neurocríticas, incluyendo la infección complicada del sistema nervioso central. Se presenta el caso de una paciente femenina de 47 años, quien ingresó en la Unidad de Cuidados Intensivos luego de presentar progresión al estado comatoso secundario a cuadro de meningoencefalitis bacteriana. Al ingreso se constata midriasis bilateral arreactiva, ausencia parcial de reflejos del tallo encefálico y bradicardia. Ante la sospecha clínica de hipertensión intracraneal, se indica ultrasonografía del diámetro de la vaina del nervio óptico en plano axial. Se realizaron tres mediciones para cada ojo, mostrando un valor de 6,3, 6,6 y 6,00 mm en ojo derecho, y 6,8, 6,6 y 6,8 mm en el izquierdo (promedio biocular: 6,5 mm). Con esta medición se complementó el diagnóstico sospechado. Esta técnica representa un proceder seguro y no invasivo. Su uso completa los datos recogidos en el examen clínico. El punto de corte universalmente aceptado para el diagnóstico es de 5,0 mm o más para un valor de presión intracraneal > 20 mmHg.


ABSTRACT The optic nerve sheath ultrasonography is a non-invasive method for monitoring intracranial pressure. It has been used in multiple neurocritical pathologies, including the complicated infection of the central nervous system. The case of a 47-year-old female patient is presented; she was admitted to the Intensive Care Unit after presenting progression to comatose state secondary to bacterial meningoencephalitis. On admission, bilateral arreactive mydriasis, partial absence of brainstem reflexes and bradycardia are confirmed. Given the clinical suspicion of intracranial hypertension, ultrasonography of the optic nerve sheath diameter in the axial plane is indicated. Three measurements were made for each eye, showing a value of 6.3, 6.6 and 6.00 in the right eye, and 6.8, 6.6 and 6.8 in the left one (biocular average: 6.5 mm). With this measurement the suspected diagnosis was completed. This technique represents a secure and non-invasive procedure. Its use completes the data collected in the clinical examination. The universally accepted cut-off point for diagnosis is 5.0 mm or more for an intracranial pressure value of > 20 mmHg.

9.
China Pharmacy ; (12): 2137-2141, 2022.
Artigo em Chinês | WPRIM | ID: wpr-941457

RESUMO

OBJECTIVE To investigate the effects of different doses of dexmedetomidine on intracranial pressure in patients undergoing gynecological laparoscopic surgery. METHODS Ninety patients undergoing selective gynecological laparoscopic surgery in trendelenburg position were divided into low-dose experimental group (group D 1),high-dose experimental group (group D 2) and control group (group C )according to random number table ,with 30 cases in each group. Group D 1 and group D 2 received continuous intravenous infusion of dexmedetomidine 1.0 μ g/kg for 10 min for induction of anesthesia ,and then continued intravenous infusion at the rate of 0.4 μg(/ kg·h)and 0.6 μg(/ kg·h)respectively. Group C was continuously pumped with the constant volume of Sodium chloride injection. Three groups stopped pumping 30 minutes before the end of the operation. The heart rate(HR)and mean arterial pressure (MAP)were recorded when entering the room (T0),10 min after intravenous pump of dexmedetomidine(T1),10 min(T2),30 min(T3),60 min(T4)after pneumoperitoneum ,10 min after pneumoperitoneum was closed to restore the supine position (T5). At the same time ,optic nerve sheath diameter (ONSD)in both eyes was measured by ultrasound,and the occurrence of intraoperative bradycardia and the use of atropine were recorded. RESULTS There was no statistical significance in ONSD ,HR or MAP among 3 groups at T 0(P>0.05). Compared with T 0,ONSD of 3 groups were decreased significantly at T 1(except for group C );ONSD of 3 groups were increased significantly at T 2-T5,while MAP and HR were all decreased significantly (P<0.05). HR of group D 2 was decreased significantly at T 1(P<0.05). Compared with group C , ONSD and HR of group D 1 and D 2 were all decreased significantly at T 1-T5(P<0.05). Compared with group C ,the number of patients with bradycardia and those who used atropine in group D 1 and D 2 were increased significantly (P<0.05). CONCLUSIONS Continuous pumping of dexmedetomidine during gynecologic laparoscopic surgery can reduce the increase of intracranial pressure in patients ;compared with pumping rate of 0.6 μg(/ kg·h),the change of patient ’s HR tends to be more stable with a pumping rate of 0.4 μg(/ kg·h).

10.
Artigo em Chinês | WPRIM | ID: wpr-1039285

RESUMO

@#The clinical presentation of cerebral venous sinus thrombosis (CVST) overlaps with that of idiopathic intracranial hypertension (IIH),but no screening tool exists. We investigated the role of eye-neck integrated ultrasound in the diagnosis and differentiation of IIH and CVST. Methods Twenty IIH patients,25 CVST patients,and 40 healthy controls were retrospectively analyzed.The ultrasonographic optic nerve sheath diameter (ONSD) and hemodynamic characteristics of the internal jugular veins(IJVs)were recorded. The cerebrospinal fluid opening pressure was measured after ultrasonic examination.Results The ONSD was significantly larger in IIH patients than in controls (4.71±0.41 vs. 3.93±0.24 mm,P<0.001).The ONSD cut off for IIH diagnosis was 4.25 mm (AUC=0.978,95%CI 0.95~1.00,P<0.001,sensitivity:90%,specificity:93%).In the CVST group,19 (76%) patients had elevated intracranial pressure (ICP);the mean ONSD was significantly higher in patients with increased ICP than in those without (4.35±0.22 vs. 3.96±0.18 mm,P<0.001).The mean blood flow volume (BFV) was significantly reduced in CVST patients (404.43±314.73 mL/min) compared to that in controls(680.37±233.03 mL/min,P<0.001) and IIH patients (617.67±282.96 ml/min,P=0.008). The optimal BFV cut off for predicting CVST was 471.60 ml/min(AUC=0.841,95%CI 0.73~0.95,P<0.001,sensitivity:88%,specificity:72%).No difference in frequency of IJVVI between patients and controls. Conclusion Eyeneck integrated ultrasound is an easily available bedside technique to assess ICP and hemodynamic characteristics of IJVs.ONSD measurement can identify patients with increased ICP,and reduced IJV BFV may aid the differentiation of CVST and IIH.

11.
Artigo em Chinês | WPRIM | ID: wpr-1039302

RESUMO

@#To explore The clinical value of Multimode ultrasound in evaluating cerebral hemorrhage with intracranial pressure(ICP). Methods A total of 17 patients with cerebral hemorrhage who received lumbar puncture according to their medical necessity in the ICU of the Affiliated Hospital of Yanbian University from September 2019 to June 2021 were enrolled. The diameter of optic nerve sheath (ONSD) and transcranial Doppler ultrasound (TCD) were performed before lumbar puncture. The patients were divided into elevated intracranial pressure group (9 cases) and normal intracranial pressure group (8 cases),according to the results of lumbar puncture pressure (more than 200 mmH2O was defined as elevated intracranial pressure,and 80~200 mmH2O was defined as normal intracranial pressure). The Systolic blood pressure,diastolic blood pressure,partial pressure of carbon dioxide,GCS,ONSD and TCD parameters (such as peak systolic velocity,end diastolic velocity,mean blood flow velocity and pulse index of bilateral middle cerebral artery) were compared between the two groups,and the correlation between ICP and ONSD,pulse index(PI) was analyzed. Results (1)The systolic blood pressure,diastolic blood pressure,partial pressure of carbon dioxide (P CO2) and GCS scores between the two groups were not significantly different (all P> 0.05);(2)The ONSD was significantly higher in the elevated intracranial pressure group[(5.15±0.24) mm vs. (3.97±0.22) mm,t=10.69,P<0.001)];(3)The systolic peak flow velocity (PSV),end diastolic flow velocity (EDV) and mean flow velocity (MV) between the two groups were not significantly different(all P> 0.05),while the PI was significantly higher in the elevated intracranial pressure group[Right(1.20±0.19) vs.(0.95±0.12),t=3.148,P=0.007);Left(1.20±0.17) vs. (0.92±0.10),t=3.893,P=0.001)].(4)ICP was significantly associated with PI (r=0.52,P<0.02) and ONSD(r=0.64,P<0.01). Conclusion Combine with Ultrasonographic ONSD measurement and TCD can effectively assess intracranial hypertension in patients with intracerebral hemorrhage.

12.
Artigo em Chinês | WPRIM | ID: wpr-989775

RESUMO

Objective:To explore the value of Glasgow coma score (GCS) combined with optic nerve sheath diameter (ONSD) in predicting the death risk of patients with cerebrocardiac syndrome (CCS).Methods:From January 2021 to September 2021, 83 patients with CCS secondary to severe traumatic brain injury (sTBI) in our hospital were collected and divided into a survival group ( n = 37) and death group ( n = 46) according to CCS-related death. The clinical data including age, sex, underlying diseases, head CT imaging manifestations, electrolytes, blood glucose, C-reactive protein (CRP), neuron-specific enolase (NSE), lactate dehydrogenase (LDH), creatine kinase (CK), creatine phosphokinase isoenzyme (CKMB), intracranial pressure (ICP), ONSD, cardiac color ultrasound, acute physiology and chronic health evaluationII (APACHEⅡ ) and GCS were analyzed and compared between the two groups. The proportion and dosage of vasoactive drugs used at admission, daily fluid balance volume during hospitalization, total amount of sedative and analgesic drugs, and average daily dose were analyzed and compared between the two groups. The independent risk factors for CCS-related death were analyzed using multivariate logistic regression. The receiver operating characteristic (ROC) curve was drawn to evaluate the predictive value of the independent risk factors in CCS-related death. Results:In this study, 55.4% of the patients died of CCS. The ONSD, ICP change rate, right ventricular Tei index and NSE in the death group were higher than those in the survival group, with statistically significant differences ( P < 0.05), while the GCS in the death group was significantly lower than that in the survival group, with a statistically significant difference ( P < 0.01). ONSD ( OR = 23.890, 95% CI: 5.526-103.286, P < 0.001), GCS ( OR = 17.066, 95% CI: 1.476-197.370, P = 0.023) and ICP change rate ( OR = 0.060, 95% CI: 0.007-0.477, P = 0.008) were the independent risk factors for CCS-related death. The area under the ROC curve (AUC = 0.897) of ONSD combined with GCS in evaluating CCS-related death was larger than that of ONSD, ICP change rate alone and the corresponding AUC of 1/GCS (0.876, 0.785, 0.800, respectively), with the advantages of non-invasive, dynamic monitoring and low inspection costs. Conclusions:The mortality rate of CCS is high. ONSD, GCS and ICP change rates are independently correlated with the death of CCS patients. ONSD combined with GCS is an ideal indicator for clinical prediction of CCS-related death.

13.
Chinese Critical Care Medicine ; (12): 635-639, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956024

RESUMO

Objective:To explore the changes of intracranial pressure in intensive care unit (ICU) patients during the occurrence and evolution of delirium by using bedside ultrasound to measure the optic nerve sheath diameter (ONSD) to evaluate intracranial pressure.Methods:A retrospective observational study was conducted. Adult patients who developed delirium during hospitalization in the general ICU of Beihai People's Hospital from October 2020 to November 2021 were enrolled, and patients who did not have ultrasonographic ONSD records within 24 hours after the diagnosis of delirium were excluded. The ONSD measured before delirium was recorded as ONSD 0, the ONSD measured within 24 hours of the onset of delirium recorded as ONSD 1, and the ONSD reexamined after ONSD 1 recorded as ONSD 2. Patients were divided into intracranial hypertension group (ONSD 1 > 5 mm) and normal intracranial pressure group (ONSD 1 ≤ 5 mm) according to the size of ONSD 1. According to the outcome of delirium, the patients were divided into cured, improved, and non-improved groups. The reduction ratio of ONSD 2 to ONSD 1 in the three groups were calculated and compared. Pearson correlation test was used to analyze the correlation between fluid balance and ONSD changes after delirium. Results:There were 43 patients, including 40 cases in the intracranial hypertension group (the incidence rate was 93.0%), 3 cases in the normal intracranial pressure group, 23 cases were cured, 13 cases were improved, and 7 cases were not improved. In the intracranial hypertension group, 11 cases had ONSD 0 and ONSD 1 records, and ONSD 1 was significantly higher than ONSD 0 [mm: 5.88±0.61 vs. 5.34±0.57, 95% confidence interval (95% CI) -0.85 to -0.23, P = 0.003]. The reduction ratio of ONSD 2 to ONSD 1 in the cured group was significantly higher than that in the improved group and the non-improved group [(12.04±6.20)% vs. (5.68±4.10)%, (0.17±3.96)%; 95% CI were 2.37 to 10.33, 6.41 to 17.31, P values were 0.003 and 0.000, respectively]. The correlation analysis showed that the reduction ratio of ONSD 2 to ONSD 1 was negatively correlated with fluid balance ( r = -0.42, 95% CI was -0.66 to -0.10, P = 0.012). Conclusions:The incidence of intracranial hypertension in ICU delirium patients is high. A more pronounced decrease in intracranial pressure predicts a better delirium outcome. Dynamic ONSD measurement can provide valuable information for the prevention and treatment of delirium.

14.
Artigo em Chinês | WPRIM | ID: wpr-1014747

RESUMO

AIM: To evaluate the effects of propofol and desflurane on intracranial pressure in patients undergoing gynecological laparoscopic surgery by measuring the ratio of optic nerve sheath diameter (ONSD) to transverse diameter of the eye (ETD). METHODS: Forty patients, scheduled for elective gynecological endoscopic surgery, were randomly divided into propofol group (group P) and desflurane group (group D) (n b 20). Anesthesia maintenance: propofol was injected intravenously in group P, desflurane was inhaled in group D. Remifentanil was injected intravenously and rocuronium was added on schedule. The patients were mechanically ventilated in volume-controlled mode. ETD was recorded after induction of anesthesia. ONSD, HR, MAP, peak airway pressure (Ppeak) and P

15.
Rev. cuba. anestesiol. reanim ; 20(3): e710, 2021. tab, graf
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1351982

RESUMO

Introducción: El neuromonitoreo no invasivo en pacientes críticos representa una opción de primera línea para el manejo de complicaciones fatales derivadas del aumento de la presión intracraneal. En esta modalidad se incluye la ultrasonografía del diámetro de la vaina del nervio óptico, la cual representa una técnica rápida, fácil de realizar y disponible a la cabecera del paciente. Objetivos: Describir aspectos fundamentales y actualizados sobre el uso de la ultrasonografía en el monitoreo de la presión intracraneal a través de la medición del diámetro de la vaina del nervio óptico en los diferentes escenarios neuroclínicos. Métodos: Se realizó una revisión de la literatura publicada en bases de datos como: PubMed/Medline, SciELO y Google académico entre los meses mayo y julio de 2020. Se revisaron publicaciones en inglés y español. Se seleccionaron 46 bibliografías que cumplieron con los criterios de inclusión. Se describen aspectos fundamentales como la anatomía ecográfica del nervio óptico, descripción de la técnica y su uso en entidades neurocríticas como el traumatismo craneoencefálico, ictus, muerte encefálica, entre otros. Conclusiones: La ecografía de la vaina del nervio óptico representa una alternativa no invasiva ampliamente aceptada para la medición del incremento de la presión intracranial. Con un diámetro de 5,0 hasta 5,9 mm o más se puede asumir el diagnóstico de hipertensión intracraneal con alta sensibilidad y especificidad, aunque debe individualizarse su uso en cada patología neurocrítica. La curva de aprendizaje para la realización del proceder es de breve tiempo y satisface las habilidades necesarias(AU)


Introduction: Noninvasive neuromonitoring in critically ill patients is a first-line option for the management of fatal complications derived from increased intracranial pressure. This modality includes ultrasound of optic nerve sheath diameter, which is a quick technique, easy to perform and available at the bedside. Objectives: To describe significant and state-of-the-art aspects regarding the use of ultrasound for monitoring intracranial pressure through measurement of the optic nerve sheath diameter in different neuroclinical settings. Methods: A review was carried out, between May and July 2020, of the literature published in databases such as PubMed/Medline, SciELO and Google Scholar. Publications in English and Spanish were reviewed. Forty-six bibliographic sources were chosen, as long as they met the inclusion criteria. Fundamental aspects are described, such as the ultrasound anatomy of the optic nerve, the technique procedures and its use in neurocritical entities such as head trauma, stroke and brain death, among others. Conclusions: Ultrasound of the optic nerve sheath is a widely accepted noninvasive choice for measurement of increased intracranial pressure. With a diameter of 5.0 to 5.9 mm or more, the diagnosis of intracranial hypertension can be assumed with high sensitivity and specificity, although its use should be individualized in each neurocritical pathology. The learning curve for carrying out the procedure is short and satisfies the necessary skills(AU)


Assuntos
Humanos , Masculino , Feminino , Nervo Óptico/diagnóstico por imagem , Pressão Intracraniana/fisiologia , Estado Terminal , Acidente Vascular Cerebral , Lesões Encefálicas Traumáticas , Traumatismos Craniocerebrais
16.
Med. crít. (Col. Mex. Med. Crít.) ; 35(6): 329-335, Nov.-Dec. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1405554

RESUMO

resumen está disponible en el texto completo


Abstract: Introduction: Traumatic brain injury (TBI) is a medical-surgical condition characterized by brain involvement secondary to a traumatic lesion. Patients with severe TBI are at high risk of mortality and this will depend on different factors such as the presence of intracranial hypertension, age, origin of the injury and score on the Glasgow coma scale. Measurement of the optic nerve sheath diameter (ONSD) appears to be a good indirect indicator of intercranial hypertension and therefore, a good predictor of mortality. Objective: To determine the most appropriate cut-off point, as well as the measurement of the ONSD usefulness as a prognostic indicator of mortality in patients with severe TBI in the Intensive Care Unit (ICU). Material and methods: This is an analytical, descriptive, and retrospective study. The universe of study consists of all the case/files with TBI. For the sample selection, all available records of patients with severe TBI sent to the ICU during the period from March 1 to August 31, 2021, will be included. Within the inclusion criteria patients with a Glasgow scale score of < 8 points on entry and with a computerized scan done. The dependent variables to considerer are the outcome understood as death or survival of the patient, the days hospitalized in the ICU, the presence of complications; among the dependent variables is the diameter of the optic nerve sheath measured by computerized tomography. Intervening variables were also considered such as the presence of comorbidities and overweight/obesity, the age and sex of the patient. The project consisted of four phases: 1) request for authorization and access to files, 2) application of selection criteria, 3) performance of ONSD measurements and 4) creation of the database. Finally, once the database is formed, the statistical analysis will proceed; for the descriptive part, prevalence's, means (standard deviation) and medians (percentiles) will be calculated for the variables by sex and by outcome, subsequently the diagnostic capacity of the ONSD will be analyzed through the area under the ROC curve (receiving operating characteristics) for the outcome. Afterwards the performance of this and other cut-off points are compared using the Youden index. Results: Sixty records of TBI patients admitted to the ICU were studied, 51 were men (85%), 45 patients survived (75%) and 15 patients died (25%). The average age was of 50.5 ± 10.6 years, the average Glasgow score on admission was 6.6 ± 1.6 points, the average BMI was 26.42 ± 4.10 kg/m2, and the average number of days spent in the ICU was 9.03 ± 6.4. The diameter of the optic nerve was not a predictor of mortality, but if the Glasgow coma scale was, with an AUC of 0.775 (95% CI: 0.648-0.901, p = 0.002), the best cut-off point was 7 with a sensitivity of 93% and specificity of 54%. The bivariate linear regression model points to low Glasgow coma score and long hospital stay as predictors of mortality. Conclusions: The results of this study infer that, consistent with current scientific evidence, the sociodemographic characteristics of our population are similar to those reported by other authors, with men over 50 years of age being the most affected by this entity. On the other hand, the measurement of the diameter of the optic nerve sheath has been considered a good prognostic indicator of intracranial hypertension, which in turn is associated with increased mortality. However, in the present study there is no association between the diameter of the optic nerve sheath and the prognosis of mortality.


Resumo: Introdução: O traumatismo cranioencefálico (TCE) é uma condição médico-cirúrgica caracterizada por lesão cerebral secundária a uma lesão traumática. Pacientes com TCE grave apresentam alto risco de mortalidade e isso dependerá de diversos fatores, como presença de hipertensão intracraniana, idade, origem da lesão e pontuação na Escala de Coma de Glasgow. A medida do diâmetro da bainha do nervo óptico (DBNO) parece ser um bom indicador indireto de hipertensão intracraniana e, portanto, um bom preditor de mortalidade. Objetivo: Determinar o ponto de corte mais adequado, bem como a utilidade da medida do DBNO como indicador prognóstico de mortalidade em pacientes com TCE grave na Unidade de Terapia Intensiva. Material e métodos: Trata-se de um estudo analítico, descritivo e retrospectivo. O universo de estudo é composto por todos os prontuários de casos/pacientes com TCE grave. Para a seleção da amostra foram incluídos todos os prontuários disponíveis de pacientes com TCE grave encaminhados à Unidade de Terapia Intensiva no período de 1o de março a 31 de agosto de 2021, dentro dos critérios de inclusão foram considerados pacientes com escala de Glasgow < 8 pontos na admissão e com uma tomografia computadorizada realizada. As variáveis ​​dependentes consideradas são o desfecho entendido como óbito ou sobrevida do paciente, os dias de internação na UTI, a presença de complicações; dentro das variáveis ​​independentes está o diâmetro da bainha do nervo óptico medido por tomografia computadorizada. Também foram consideradas variáveis ​​intervenientes, como presença de comorbidades e sobrepeso/obesidade, idade e sexo do paciente. O projeto consistiu em três fases: a) Pedido de autorização e acesso aos prontuários, b) Aplicação dos critérios de seleção, c) Desenvolvimento da base de dados. Por fim, uma vez formada a base de dados, procedeu-se à análise estatística. Para a parte descritiva, foram calculadas as prevalências, médias (desvio padrão) e medianas (percentis) das variáveis ​​por sexo e por desfecho. Posteriormente, a capacidade diagnóstica do DBNO foi analisada pela área sob a curva ROC (Receiving Operating Characteristics) para o resultado. Posteriormente, o desempenho deste e de outros pontos de corte foi comparado pelo índice de Youden. Resultados: Foram estudados 60 prontuários de pacientes com TCE que deram entrada na UTI, 51 eram homens (85%), 45 pacientes sobreviveram (75%) e 15 pacientes morreram (25%). A média de idade foi de 50.5 ± 10.6 anos, a média de Glasgow na admissão foi de 6.6 ± 1.6 pontos, a média de IMC foi de 26.42 ± 4.10 kg/m2 e a média de dias de internação na UTI foi de 9.03 ± 6.4. O diâmetro do nervo óptico não foi preditor de mortalidade, mas a Escala de Coma de Glasgow sim, com AUC de 0.775 (IC 95%: 0.648-0.901, p = 0.002), o melhor ponto de corte foi 7 com sensibilidade de 93% e especificidade de 54%. O modelo de regressão linear bivariada aponta para baixo escore de coma de Glasgow e longa permanência hospitalar como preditores de mortalidade. Conclusões: Os resultados deste estudo inferem que, de acordo com as evidências científicas atuais, as características sociodemográficas de nossa população são semelhantes às relatadas por outros autores, sendo os homens com aproximadamente 50 anos de idade os mais acometidos por essa entidade. Por outro lado, a medida do diâmetro da bainha do nervo óptico tem sido considerada um bom indicador prognóstico de hipertensão intracraniana, que por sua vez está associada ao aumento da mortalidade. No entanto, no presente estudo não há associação entre o diâmetro da bainha do nervo óptico e o prognóstico de mortalidade.

17.
Chinese Journal of Traumatology ; (6): 180-182, 2021.
Artigo em Inglês | WPRIM | ID: wpr-879680

RESUMO

Early diagnosis of cerebral fat embolism in a patient with contradiction to MRI is challenging. Here we report an interesting case, where the raised optic nerve sheath diameter helped us to predict the early cerebral involvement with fat emboli in a left femoral shaft fracture patient. MRI scan could not be performed due to the presence of a metallic implant in the patient from a previous surgery. He was later diagnosed as an atypical presentation of fat embolism syndrome. Optic nerve sheath monitoring also helped us to guide further management of the patient.

18.
Artigo em Chinês | WPRIM | ID: wpr-880836

RESUMO

OBJECTIVE@#To investigate the effects of restrictive fluid management in patients with severe traumatic brain injury (sTBI).@*METHODS@#Between January, 2019 and June, 2020, we randomly assigned 51 postoperative patients (stay in the ICU of no less than 7 days) with sTBI into treatment group (@*RESULTS@#The cumulative fluid balance of the two groups were positive on day 1 and negative on days 3 and 7 after ICU admission; at the same time points, the patients in the treatment group had significantly greater negative fluid balance than those in the control group (@*CONCLUSIONS@#Restrictive fluid management can reduce cerebral edema and improve the prognosis but does not affect the 28-day mortality of patients with sTBI.


Assuntos
Humanos , Lesões Encefálicas Traumáticas/terapia , Hidratação , Prognóstico , Respiração Artificial , Resultado do Tratamento
19.
Artigo em Chinês | WPRIM | ID: wpr-1039330

RESUMO

@#To explore whether ultrasound measurement of optic disc height can evaluate intracranial hypertension and the value of ultrasound measurement of optic nerve sheath diameter combined with optic disc height in the diagnosis of elevated intracranial hypertension. Methods Enrolled patients who needed lumbar puncture in the Department of Neurology of the First Hospital of Jilin University between July 2019 and November 2020.Complete ultrasound examination before lumbar puncture,measure ONSD and ODH. According to the lumbar puncture pressure,the patients were divided into normal intracranial pressure group and intracranial hypertension group. Singlefactor and multifactor analysis were performed to obtain the relationship between ICP and each ultrasound data. Analyze the correlation between ICP and ONSD and ODH. Generate ROC curve,evaluate and compare the value of ONSD,ODH and ONSD combined with ODH in diagnosing intracranial hypertension. Results A total of 78 patients,39 cases in each group. There was no statistical difference in baseline data between the two groups. (1) ONSD[(5.04±0.34) mm]in intracranial hypertension group is higher than normal intracranial pressure group[(4.17±0.38) mm](P<0.001);ODH[0.81 (0.59-1) mm]in intracranial hypertension group is higher than normal intracranial pressure group[0.39 (0-0.59) mm](P<0.001);(2)Correlation analysis showed that ICP was positively correlated with ONSD (r=0.779,P<0.001)and ODH(r=0.572,P<0.001);(3) The cutoff value of ODH for diagnosing elevated ICP is 0.54 mm,the sensitivity and specificity are 85% and 72%,respectively;the cutoff value of ONSD for diagnosing elevated ICP is 4.68 mm,the sensitivity and specificity are 87% and 95%,respectively;The sensitivity and specificity of ONSD combined with ODH in the diagnosis of elevated ICP are 95% and 95%,respectively;(4)Compare the value of the three in diagnosing elevated ICP,ONSD is greater than ODH (P=0.036),ONSD combined with ODH is greater than ONSD(P=0.043)or ODH (P=0.001) alone. Conclusion Ultrasound measurement of ODH can be used to diagnose intracranial hypertension.ONSD combined with ODH can improve the sensitivity of diagnosing elevated ICP.

20.
Artigo em Chinês | WPRIM | ID: wpr-907729

RESUMO

Objective:To explore the value of ultrasonic measurement of optic nerve sheath diameter (ONSD) in predicting the risk of death in patients with severe brain injury.Methods:This was a prospective observational study based on 84 postoperative patients with severe brain injury from January 2020 to September 2020 in our department. The patients were divided into two groups: the survival group and the deceased group. The clinical features between the two groups were compared. Receiver operating characteristic (ROC) curves were used to evaluate the sensitivity and specificity of ONSD, neuron-specific enolase (NSE) and the combination of the two in predicting death in patients with severe brain injury. Binary logistic regression was used to analyze the independent risk factors for death. A prediction model for the risk of death was constructed.Results:There were 61 cases (72.6%) in the survival group and 23 cases (27.4%) in the deceased group. There were significant differences in age, Glasgow coma score (GCS), ONSD and NSE at 12 h after surgery between the two groups. According to the ROC curve, the optimal cutoff levels of ONSD and NSE for predicting death were 5.5 mm and 21.75 ng/mL, respectively. When the two indicators were combined, the area under the curve was 0.897 ( P<0.01). At this threshold, the sensitivity and specificity were 100% and 70.5%, respectively. ONSD ( OR=9.713; 95% CI: 1.192-79.147) and GCS scores ( OR=0.492; 95% CI: 0.318-0.763) at 12 h after surgery were independent risk factors for death in patients with severe brain injury (both P<0.05). Conclusions:Early postoperative ONSD is an independent risk factor for death in patients with severe brain injury. The combination of ONSD and NSE has the best predictive effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA