Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 995
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1009107

RESUMO

OBJECTIVE@#To explore the effectiveness of Nice knot technique for wound closure in Gustilo type ⅢA and ⅢB open tibial fractures.@*METHODS@#A retrospective study was performed on 22 patients with Gustilo type ⅢA and ⅢB open tibial fractures, who underwent wound closure using the Nice knot technique and were admitted between June 2021 and June 2022. There were 15 males and 7 females. The age ranged from 18 to 67 years, with an average of 41.9 years. The causes of injury included traffic accident in 11 cases, falling from height in 7 cases, and heavy object injuries in 4 cases. Fractures were located on the left side in 9 cases and on the right side in 13 cases. And 9 cases were type ⅢA fractures and 13 were type ⅢB fractures according to Gustilo classification. All patients had extensive soft tissue injuries, and no vascular or neurological damage was observed. The time from injury to debridement was 3-8 hours (mean, 6.5 hours). The sizes of wounds before operation and at 2 weeks after operation were measured and wound healing rate at 2 weeks after operation were calculated. The wound healing time and wound healing grading were recorded. The Vancouver Scar Scale (VSS) score was used to assess the wound scar after wound healed and the excellent and good rate was calculated.@*RESULTS@#The wound area was 21.0-180.0 cm 2 (mean, 57.82 cm 2) before operation, and it was 1.2-27.0 cm 2 (mean, 6.57 cm 2) at 2 weeks after operation. The wound healing rate at 2 weeks after operation was 76%-98% (mean, 88.6%). After operation, 2 cases needed to adjust Nice knot due to skin cutting and 1 case occurred soft tissue infection on the wound. The other patient's wounds healed. The average wound healing time was 27.8 days (range, 18-44 days). And the wound healing were grade A in 13 cases and grade B in 9 cases. VSS score was 2-9, with an average of 4.1; 10 cases were rated as excellent, 10 as good, and 2 as poor, with an excellent and good rate of 90.9%. All patients were followed up 9-24 months (mean, 14.6 months). During follow-up, no deep infection or osteomyelitis occurred. Two cases experienced fracture non-union, and were treated with compression fixation and bone grafting. The fractures of the other patients all healed, with a healing time of 85-190 days (mean, 148.2 days).@*CONCLUSION@#Nice knot technique can be used in wound closure of Gustilo type ⅢA and ⅢB open tibial fractures effectively, which is easy to operate.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Cicatriz , Estudos Retrospectivos , Resultado do Tratamento , Fraturas da Tíbia/cirurgia , Cicatrização , Fixação Interna de Fraturas/métodos , Fraturas Expostas/cirurgia
2.
Artigo em Chinês | WPRIM | ID: wpr-1009117

RESUMO

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Assuntos
Humanos , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Fixação Intramedular de Fraturas , Fraturas da Tíbia/cirurgia , Fraturas do Planalto Tibial
3.
Rev. bras. ortop ; 59(2): 318-322, 2024. graf
Artigo em Inglês | LILACS | ID: biblio-1565379

RESUMO

Abstract A middle-aged female patient with a tibial plateau fracture combined with an avulsion of the tibial eminence was treated with a combination of medial plate fixation for the plateau and an arthroscopic aided nonabsorbable suture of the eminence. Our technique for tibial eminence avulsion fractures has no interference with tibial plateau osteosynthesis materials and has proven, once again, to have good results in the treatment of combined and complex injuries of the knee.


Resumo Uma paciente de meia-idade com fratura do platô tibial e avulsão da eminência tibial foi tratada com uma combinação de fixação do platô com placa medial e sutura da eminência com fio não absorvível auxiliada por artroscopia. Nossa técnica para fraturas com avulsão da eminência tibial não interfere nos materiais de osteossíntese do platô tibial e, mais uma vez, teve bons resultados no tratamento de lesões combinadas e complexas do joelho.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Artroscopia , Fraturas da Tíbia , Fixação Interna de Fraturas , Traumatismos do Joelho
4.
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1552154

RESUMO

Introducción: Las fracturas de tibia por estrés son un cuadro muy frecuente en el personal militar recién incorporado. Nuestro objetivo fue demostrar que existe una asociación entre fracturas por estrés y otros hallazgos patológicos. materiales y métodos: Se evaluaron retrospectivamente 42 fracturas por estrés en 34 pacientes, entre noviembre de 2012 y septiembre de 2014. Todos se habían incorporado recientemente al Ejército Argentino y consultaron por cuadros dolorosos en la tibia. Se realizó el diagnóstico clínico y centellográfico de fractura por estrés. Se documentaron datos filiatorios, hallazgos patológicos asociados y factores de riesgo. Los criterios de inclusión fueron: reciente incorporación, mismo entrenamiento, edad 16-23 años. Se excluyó a pacientes con traumatismos, enfermedad tumoral o centellograma negativo, y a los simuladores. Resultados: Se evaluaron 42 fracturas por estrés en 34 pacientes (14 hombres y 20 mujeres). La edad promedio era de 20 años. No hubo diferencias significativas en el número de lesiones respecto al miembro afectado. El 64,7% tenía hallazgos patológicos asociados (mujeres 73%, hombres 27%). El 80% de las mujeres y el 43% de los hombres tenían un hallazgo patológico asociado. Se detectaron diversos hallazgos patológicos asociados con desejes de miembros inferiores en varo y en valgo, los primeros fueron los que más se asociaron con fracturas. Conclusiones: La tasa de asociación con hallazgos patológicos en los miembros inferiores fue alta, con predominio de los desejes en varo. Las mujeres con fracturas por estrés tenían más hallazgos patológicos asociados que los hombres. Nivel de Evidencia: IV


Introduction: Tibial stress fractures are a very common condition in military recruits. Our objective is to demonstrate that stress fractures are associated with other pathologies. materials and methods: 42 stress fractures in 34 patients were retrospectively evaluated. Every patient had recently joined the Argentine Army and consulted for painful symptoms in the tibia. A clinical and scintigraphic diagnosis of stress fracture was made. Patient data, associated pathologies, and risk factors were documented. Inclusion criteria: recent incorporation, same training, age between 16 and 23 years. Trauma, simulators, tumoral pathology, and cases with negative scintigraphy were excluded. Results: We studied 42 stress fractures in 34 patients, 14 were men and 20 were women. The average age was 20 years. There were no significant differences in the number of injuries regarding the affected limb. 64.7% had associated pathologies, 73% in women and 27 % in men. Among the women with stress fractures, 80% had associated pathologies, compared to 43% for men. Different pathologies were found with lower limb varus and valgus imbalances. Varus was the most associated with fractures. Conclusions: A high rate of associated pathologies was found in patients with tibial stress fractures with a predominance of lower limb varus imbalances. Associated pathologies were more likely to be found in women with stress fractures than in men. Level of Evidence: IV


Assuntos
Adolescente , Adulto , Fraturas da Tíbia , Fraturas de Estresse , Traumatismos da Perna , Militares
5.
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1552156

RESUMO

La fijación elástica en las lesiones de la sindesmosis es un procedimiento que se realiza ampliamente y brinda buenos resultados. Presentamos un caso de una fractura de tibia como complicación de la fijación elástica de la sindesmosis, su tratamiento y una revisión bibliográfica en la cual no hemos encontrado reportes sobre esta complicación. Nivel de Evidencia: IV


Elastic fixation in syndesmosis injuries is a widely performed procedure with good outcomes. We report a case of a tibial fracture as a complication of the elastic fixation of the syndesmosis, its treatment, and a literature review, in which we have not found reports of this complication. Level of Evidence: IV


Assuntos
Pessoa de Meia-Idade , Fraturas da Tíbia , Traumatismos do Tornozelo , Fixação Interna de Fraturas , Articulação do Tornozelo
6.
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1556246

RESUMO

Introducción: Las epifisiólisis de la tuberosidad anterior de la tibia en adolescentes representan el 1% de las lesiones fisarias y el 3% de las fracturas de la tibia proximal, y pueden comprometer la fisis; por lo tanto, ameritan un diagnóstico y un tratamiento correctos para evitar complicaciones. El objetivo de este artículo es comunicar un caso clínico, compararlo con casos similares publicados, analizar las diferencias y, sobre la base de la experiencia, llegar a una conclusión para su resolución. Presentamos a un varón de 13 años que consultó tras sufrir un traumatismo directo en la rodilla derecha, durante la carrera en la práctica deportiva, un mes atrás. La radiografía mostró epifisiólisis por avulsión de la tuberosidad anterior de la tibia (Ogden IIIA, Jones III), por lo que fue sometido a reducción abierta y fijación. Como la recuperación y el retorno a la actividad habitual fueron rápidos, se tomaron un par radiográfico para el diagnóstico y una tomografía para la planificación quirúrgica. Conclusión: Si bien no hay un consenso sobre el diagnóstico y el tratamiento por la baja cantidad de casos publicados, es conveniente sospechar este cuadro en pacientes jóvenes que sufren un traumatismo en la rodilla que limita la extensión. Nivel de Evidencia: IV


Epiphysiolysis of the anterior tibial tubercle in adolescents accounts for 1% of physeal injuries and 3% of proximal tibial fractures, and it may involve the physis, necessitating diagnosis and treatment to prevent complications. Objective: To present a case, compare it existing literature, analyze differences, and propose resolutions based on our experience. A 13-year-old male consulted after suffering direct trauma to his right knee while running in sports practice one month earlier. Radiography revealed epiphysiolysis due to avulsion of the anterior tibial tubercle (Odgen IIIA and Jones III), prompting open reduction and internal fixation with two partially-threaded cannulated screws and washers. After six weeks of cast immobilization, he began rehabilitation. Given his swift recovery, AP and lateral radiographs were obtained for diagnosis and a CT scan for surgery planning, leading to a second surgery involving open reduction and internal fixation with two cannulated screws surrounding the physis, although the patellar tendon was explored first to mitigate the risk of invagination within the fracture line. Conclusion: Despite the scarcity of reported cases, a rising trend due to increased youth sports participation underscores the importance of considering this injury in young patients presenting with knee trauma and restricted extension. Level of Evidence: IV


Assuntos
Criança , Fraturas da Tíbia , Fratura Avulsão , Traumatismos do Joelho
7.
Rev. bras. ortop ; 58(5): 808-812, Sept.-Oct. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1529944

RESUMO

Abstract The present study reports a rare case of avulsion fracture of the tibial tuberosity in an adolescent. A 14-year-old male patient sprained his left knee during a soccer match. At the first emergency-room visit, he presented pain in his left knee, 2 +/4+ edema, and inability to walk and flex the affected knee, but no neurovascular changes or signs of compartment syndrome. Radiographs revealed a physeal fracture at the left proximal tibia, classified by Ogden, Tross and Murphy, and modified by Ryu and Debenham, as type IV, and complemented by Aerts et al. as type IV-B. Immobilization was performed with a plaster cast from the inguinal to malleolar regions, followed by analgesia. The patient was operated on the next day, when open reduction and internal fixation using 4.5-mm cannulated screws were performed. The patient was discharged one day after surgery, with plaster cast immobilization and load restraint for four weeks, and bone consolidation was radiologically confirmed three months after the procedure. The patient evolved with a range of motion similar to that of the contralateral limb, no length discrepancy in the lower limbs, and no complaints after one year of follow-up.


Resumo O presente estudo tem como objetivo relatar um caso raro de fratura por avulsão da tuberosidade da tíbia em adolescente. Um paciente de 14 anos, do sexo masculino, sofreu entorse de joelho esquerdo durante partida de futebol. No primeiro atendimento em pronto-socorro, ele apresentava dor no joelho esquerdo, edema 2 +/4 + , incapacidade de deambulação e de flexo-extensão do joelho acometido, sem alterações neurovasculares ou sinais de síndrome compartimental. Nas radiografias, identificou-se fratura fisária na tíbia proximal esquerda, classificada por Ogden, Tross e Murphy, com modificação por Ryu e Debenham, como tipo IV, e complementada por Aerts et al. como tipo IV-B. Foi realizada imobilização com tala gessada inguino-maleolar e analgesia, e o paciente submetido a cirurgia no dia seguinte, com redução aberta e fixação interna utilizando parafusos canulados 4,5 mm. O paciente recebeu alta no dia seguinte à cirurgia, sendo mantida a imobilização com tala gessada e a restrição de carga por quatro semanas, e apresentou consolidação óssea confirmada por radiografia com três meses do pós-operatório. O paciente evoluiu sem discrepância de comprimento dos membros inferiores, arco de movimento igual ao do membro contralateral, e sem queixas no seguimento de um ano.


Assuntos
Humanos , Masculino , Adolescente , Fraturas da Tíbia , Fratura Avulsão , Traumatismos do Joelho
8.
Rev. venez. cir. ortop. traumatol ; 55(1): 74-80, jun. 2023. ilus, tab
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1513225

RESUMO

Las fracturas triplanares de tibia distal, son fracturas complejas caracterizadas por afectación multiplanar, clasificándose como Salter Harris tipo IV, en el periodo de cierre fisiario. Son poco frecuentes, representando el 5-15% de las fracturas pediátricas. El mecanismo de lesión que ocurre con mayor frecuencia, consiste en supinación y rotación externa. La tomografía computarizada es actualmente el Gold Standard para el diagnóstico de este tipo de fractura, nos permite evaluar todos los planos, siendo la radiografía simple insuficiente para el diagnóstico ya que puede pasar desapercibida. Paciente de 14 años de edad con fractura triplanar en 2 partes de tibia distal, con resolución quirúrgica. Nuestro caso es un ejemplo de una fractura triplanar de tibia distal, la cual es de baja frecuencia, difícil diagnostico e interpretación. Presentamos imágenes preoperatorias, intraoperatorias y postoperatorias del manejo de esta lesión, obteniendo resultados satisfactorios clínicos, funcionales y en estudios de imágenes. Es indispensable lograr una reducción anatómica de la superficie articular para lograr una evolución satisfactoria. Se recomienda una tomografía computarizada para diagnosticar y manejar esta lesión de manera adecuada. El seguimiento postoperatorio es crucial para el manejo de este paciente, ya que se espera una discrepancia en la longitud de las extremidades y/o deformidad(AU)


Triplane fractures of the distal tibia are complex fractures characterized by multiplane effects. They are classified in the Salter-Harris system as type IV in the period of physeal closure. These fractures are rare and represent 5-15% of pediatric fractures. The most common mechanism of injury is supination and external rotation. Computed tomography is currently the Gold Standard for the diagnosis of this type of fracture since it allows us to evaluate all planes, while plain radiography is insufficient because the fracture can go unnoticed. The objective is to report the clinical case of a 14-year-old patient with triplanar fracture in 2 parts of the distal tibia with surgical resolution. This case is an example of a triplanar fracture of the distal tibia, which is of low frequency, and difficult to diagnose and interpret. Preoperative, intraoperative and postoperative images of the management of this lesion are presented, obtaining satisfactory clinical, functional and imaging study results. It is essential to achieve an anatomical reduction of the joint surface to achieve a satisfactory evolution. A CT scan is recommended to properly diagnose and manage this injury. Postoperative follow-up is crucial for the management of this patient, as a limb length discrepancy and/or deformity is expected(AU)


Assuntos
Humanos , Masculino , Adolescente , Rotação , Fraturas da Tíbia/cirurgia , Supinação
9.
Rev. bras. ortop ; 58(2): 313-319, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449792

RESUMO

Abstract Objectives To describe a series of cases of tibial fractures surgically treated using the posterior approach as described by Carlson, focusing on evaluating its functional results and complication rate. Methods Eleven patients with tibial plateau fractures, who underwent surgical treatment using the Carlson approach from July to December 2019, were followed-up. The minimum follow-up period was defined as 6 months. The American Knee Society Score (AKSS), American Knee Society Score/Function (AKSS/Function) and the Lysholm score were used to check treatment results at 6 months after the fracture. The patients underwent standard anteroposterior and lateral radiographs to assess fracture healing, and clinical healing was determined by the absence of pain during full weight-bearing. Results The mean follow-up period was 12 months (9-16 months). The primary mechanism of trauma was motorcycle accident, and the most prevalent side of fracture was the right side. Eight participants were male. The mean age of the patients was 28 years. All fractures healed, and none of the patients presented complications. The AKSS was excellent in 11 patients, with a mean AKSS/Function of 99.1±3, and Lysholm scores with a median of 95.0±5.6. Conclusions The Carlson approach for posterior fractures of the tibial plateau can be considered safe, presenting a low complication rate and satisfactory functional results.


Resumo Objetivos O objetivo deste trabalho é descrever uma série de casos de fraturas de tíbia submetidas ao tratamento cirúrgico pela via posterior de Carlson para avaliação de resultados funcionais e frequência de complicações. Métodos Onze pacientes com fraturas do platô tibial foram submetidos a tratamento cirúrgico pela via de Carlson de julho a dezembro de 2019 e acompanhados por um período mínimo de 6 meses. As pontuações American Knee Society Score (AKSS), American Knee Society Score/Function (AKSS/Função) e de Lysholm verificaram os resultados do tratamento 6 meses após a fratura. Os pacientes foram submetidos a radiografias comuns em incidência anteroposterior e de perfil para avaliação da consolidação da fratura e a cicatrização clínica foi determinada pela ausência de dor à descarga total de peso. Resultados O período médio de acompanhamento foi de 12 meses (9 a 16 meses). O principal mecanismo de trauma foi acidente motociclístico e a fratura foi mais prevalente no lado direito. Oito pacientes eram do sexo masculino. A média de idade dos pacientes foi de 28 anos. Todas as fraturas cicatrizaram e nenhum paciente apresentou complicações. A AKSS foi excelente em 11 pacientes, com AKSS/Função média de 99,1 ±3, e a mediana das pontuações de Lysholm foi de 95,0 ±5,6. Conclusões Nas fraturas posteriores do platô tibial, a abordagem de Carlson pode ser considerada segura, apresentando baixo índice de complicações e resultados funcionais satisfatórios.


Assuntos
Humanos , Masculino , Feminino , Avaliação de Processos e Resultados em Cuidados de Saúde , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/complicações
10.
Chinese Journal of Surgery ; (12): 675-680, 2023.
Artigo em Chinês | WPRIM | ID: wpr-985797

RESUMO

Objective: To explore the long-term effect of combined surgery for the treatment of congenital tibial pseudarthrosis in children. Methods: The clinical data of 44 children with congenital tibial pseudarthrosis who underwent combined surgery (tibial pseudarthrosis tissue resection, intramedullary rod fixation, Ilizarov external fixator fixation, wrapped autologous iliac bone graft) from August 2007 to October 2011 at the Department of Pediatric Orthopedics, Hunan Children's Hospital were collected retrospectively. There were 33 males and 11 females. The age at the time of surgery was (3.7±2.2)years (range:0.6 to 12.4 years), including 25 cases under 3 years old and 19 cases above 3 years old.Among them, 37 cases were complicated with neurofibromatosis type 1.The operation status, postoperative complications and follow-up results were recorded. Results: The follow-up time after surgery was (10.9±0.7)years (range:10 to 11 years).Thirty-nine out of 44 patients (88.6%) achieved initial healing of tibial pseudarthrosis, with an average healing time of (4.3±1.1)months (range:3 to 10months).In the last follow-up, 36 cases (81.8%) had unequal tibial length, 20 cases (45.4%) had refractures, 18 cases (40.9%) had ankle valgus, 9 cases (20.4%) had proximal tibial valgus, and 11 cases (25.0%) had high arched feet.Nine cases (20.4%) developed distal tibial epiphyseal plate bridging.17 cases (38.6%) had abnormal tibial mechanical axis.Seven cases (15.9%) developed needle infection, and one case (2.3%) developed tibial osteomyelitis. 21 patients (47.7%) had excessive growth of the affected femur.Five patients (11.3%) had ankle stiffness, and 34 patients (77.2%) had intramedullary rod displacement that was not in the center of the tibial medullary cavity.Among them, 8 cases (18.1%) protruded the tibial bone cortex and underwent intramedullary rod removal.18 children have reached skeletal maturity, while 26 children have not been followed up until skeletal maturity. Conclusion: Combined surgery for the treatment of congenital pseudarthrosis of the tibia in children has a high initial healing rate, but complications such as unequal tibia length, refracture, and ankle valgus occur during long-term follow-up, requiring multiple surgical treatments.


Assuntos
Masculino , Feminino , Humanos , Criança , Pré-Escolar , Pseudoartrose/congênito , Seguimentos , Estudos Retrospectivos , Tíbia/cirurgia , Neurofibromatose 1 , Fraturas da Tíbia/cirurgia
11.
Artigo em Chinês | WPRIM | ID: wpr-981607

RESUMO

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Assuntos
Masculino , Feminino , Humanos , Adulto , Estudos Retrospectivos , Perda Sanguínea Cirúrgica , Fraturas do Planalto Tibial , Resultado do Tratamento , Placas Ósseas , Fraturas da Tíbia/cirurgia , Articulação do Joelho , Fixação Interna de Fraturas , Osteotomia , Suporte de Carga
12.
Artigo em Chinês | WPRIM | ID: wpr-981634

RESUMO

OBJECTIVE@#To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.@*METHODS@#The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.@*RESULTS@#There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).@*CONCLUSION@#For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.


Assuntos
Humanos , Ligamento Cruzado Posterior/lesões , Âncoras de Sutura , Fratura Avulsão/cirurgia , Estudos Retrospectivos , Fraturas da Tíbia/cirurgia , Artroscopia/métodos , Fixação Interna de Fraturas/métodos , Articulação do Joelho/cirurgia , Parafusos Ósseos , Técnicas de Sutura , Resultado do Tratamento
13.
Artigo em Chinês | WPRIM | ID: wpr-981648

RESUMO

OBJECTIVE@#To explore the effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament (PCL) tibial insertion fractures in adults.@*METHODS@#Between October 2019 and October 2021, 16 patients with PCL tibial insertion fractures were treated with arthroscopic binding fixation using suture through single bone tunnel. There were 11 males and 5 females with an average age of 41.1 years (range, 26-58 years). The fractures were caused by traffic accident in 12 cases and sports in 4 cases. The time from injury to operation ranged from 2 to 10 days with an average of 6.0 days. The fractures were classified as Meyers-McKeever type Ⅱ in 4 cases and type Ⅲ in 9 cases, and Zaricznyi type Ⅳ in 3 cases. There were 2 cases of grade Ⅰ, 7 cases of grade Ⅱ, and 7 cases of grade Ⅲ in the posterior drawer test. There were 3 cases combined with lateral collateral ligament injury and 2 cases with meniscus injury. The visual analogue scale (VAS) score, Lysholm score, International Knee Documentation Committee (IKDC) score, and knee range of motion were used to evaluate knee joint function. The posterior drawer test and knee stability tester (Kneelax 3) were used to evaluate knee joint stability. The X-ray films were used to evaluate fracture reduction and healing.@*RESULTS@#All incisions healed by first intention after operation. There was no incision infection, popliteal neurovascular injury, or deep venous thrombosis of lower limbs. All patients were followed up 6-12 months, with an average of 10 months. X-ray films at 6 months after operation showed the fractures obtained bone union. There were 11 cases of grade 0, 4 cases of gradeⅠ, and 1 case of grade Ⅱin posterior drawer test, showing significant difference when compared with preoperative results ( Z=23.167, P<0.001). The VAS score, Lysholm score, IKDC score, knee range of motion, and the results of Kneelax3 examination all significantly improved when compared with preoperative results ( P<0.05).@*CONCLUSION@#For adult patients with PCL tibial insertion fractures, the arthroscopic binding fixation using suture through single bone tunnel has the advantages of minimal trauma, good fracture reduction, reliable fixation, and fewer complications. The patient's knee joint function recovers well.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Lesões do Ligamento Cruzado Anterior/cirurgia , Artroscopia/métodos , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/lesões , Técnicas de Sutura , Suturas , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
14.
Artigo em Chinês | WPRIM | ID: wpr-981688

RESUMO

OBJECTIVE@#To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.@*METHODS@#Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.@*RESULTS@#Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.@*CONCLUSION@#Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.


Assuntos
Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Fraturas do Planalto Tibial , Placas Ósseas , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Articulação do Joelho/cirurgia , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
15.
Artigo em Chinês | WPRIM | ID: wpr-981734

RESUMO

OBJECTIVE@#To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.@*METHODS@#From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).@*RESULTS@#All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).@*CONCLUSION@#The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fraturas do Planalto Tibial , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Placas Ósseas , Estudos Retrospectivos
16.
Artigo em Chinês | WPRIM | ID: wpr-981752

RESUMO

OBJECTIVE@#To explore the effect of a modified three-point bending fracture device for establishing a rabbit model of closed tibial fracture.@*METHODS@#The model of closed tibial fracture was established in 40 6-month-old male New Zealand white rabbits with a body weight of 2.5 to 3.0 kg, and the model was verified at 6 weeks after operation. Five rabbits underwent pre modeling without temporary external fixation before modeling, and then were fractured with a modified three-point bending fracture device;35 rabbits underwent formal modeling. Before modeling, needles were inserted, and splints were fixed externally, and then the fracture was performed with a modified three-point bending fracture device. The fracture model and healing process were evaluated by imaging and histopathology at 2 hours, 4 weeks, and 6 weeks after operation.@*RESULTS@#Two hours after modeling, the prefabricated module showed oblique fracture in varying degrees and the broken end shifted significantly;Except for 1 comminuted fracture, 2 curved butterfly fractures and 2 without obvious fracture line, the rest were simple transverse and oblique fractures without obvious displacement in formal modeling group. According to the judgment criteria, the success rate of the model was 85.71%. Four weeks after modeling, the fixed needle and splint of the experimental rabbits were in good position, the fracture alignment was good, the fracture line was blurred, many continuous callus growths could be seen around the fracture end, and the callus density was high. Six weeks after modeling, many thick new bone trabeculae at the fracture, marginal osteoblasts attached, and a small number of macrophages were seen under the microscope. The intramembrane osteogenesis area was in the preparation bone stage, the medullary cavity at the fracture had been partially reopened, the callus was in the absorption plastic stage, and many osteoclasts were visible. The X-ray showed that the fracture line almost disappeared, part of the medullary cavity had been opened, the external callus was reduced around, the callus was in the plastic stage, and the bone cortex was continuous. It suggests that the fracture model showed secondary healing.@*CONCLUSION@#The improved three-point bending fracture device can establish a stable rabbit model of closed tibial fracture, and the operation is simple, which meets the requirements of closed fracture model in basic research related to fracture healing.


Assuntos
Coelhos , Masculino , Animais , Calo Ósseo , Consolidação da Fratura , Fraturas da Tíbia/cirurgia , Osteogênese , Radiografia
17.
Chinese Journal of Traumatology ; (6): 106-110, 2023.
Artigo em Inglês | WPRIM | ID: wpr-970982

RESUMO

A cruciate ligament avulsion is a much less common form of injury than a cruciate ligament tear. Simultaneous tibial avulsion fractures of both cruciate ligaments occur even more rarely. Over the last decades, many studies have described arthroscopic fixation of acute cruciate tibial avulsion fractures, but arthroscopic treatment in a late presenting patient has not been reported in the literature. This case report presents a 32-year-old female with a chronic tibial avulsion fracture of both anterior cruciate ligament and posterior cruciate ligament. Simultaneous fixation of both fractures was performed arthroscopically at week four post-injury. At one year of follow-up, the patient had demonstrated full knee range of motion and stable knee with no complaints, and achieved excellent clinical outcomes. Radiographs showed union of both fractures, and the patient had resumed high-impact exercises.


Assuntos
Feminino , Humanos , Adulto , Fratura Avulsão/cirurgia , Artroscopia , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Técnicas de Sutura , Resultado do Tratamento
18.
Artigo em Chinês | WPRIM | ID: wpr-1009023

RESUMO

OBJECTIVE@#To investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial.@*METHODS@#A study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference ( P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion.@*RESULTS@#① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups ( P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant ( P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant ( P>0.05). There was no significant difference in the operation time between groups ( P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups ( P<0.05); there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant ( P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups ( P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups ( P>0.05), while there was a significant difference in IL-6 between groups ( P<0.05).@*CONCLUSION@#Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.


Assuntos
Humanos , Ácido Tranexâmico/uso terapêutico , Perda Sanguínea Cirúrgica/prevenção & controle , Interleucina-6 , Estudos Prospectivos , Fraturas do Planalto Tibial , Fraturas da Tíbia/cirurgia , Trombose
19.
Artigo em Chinês | WPRIM | ID: wpr-1009065

RESUMO

OBJECTIVE@#To investigate the effectiveness of arthroscopic multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of anterior cruciate ligament (ACL) involving the anterior root of lateral meniscus (LM).@*METHODS@#A retrospective analysis was conducted on the clinical data of 28 patients with tibial insertion avulsion fracture of ACL involving the anterior root of LM who were treated with arthroscopic multi-point fixation with anchor and suture between October 2017 and January 2023. There were 12 males and 16 females with the mean age of 26 years (range, 13-57 years). There were 20 cases of sports injury and 8 cases of traffic accident injury. In 2 cases of old fracture, the time from injury to operation was 45 days and 90 days, respectively; in 26 cases of fresh fracture, the time from injury to operation was 3-20 days (mean, 6.7 days). According to the Meyers-McKeever classification, there were 4 cases of type Ⅱ, 11 cases of type Ⅲ, and 13 cases of type Ⅳ. The preoperative Lysholm knee function score was 42.1±9.0, the International Knee Documentation Committee (IKDC) score was 40.0±7.3, and the Tegner score was 0.7±0.7.@*RESULTS@#All operations were successfully completed, and the incisions healed by first intention. All the 28 patients were followed up 5-60 months (mean, 20.4 months). During the follow-up, there was nocomplication such as infection, vascular or nerve injury, loosening or breakage of internal fixator, or stiffness of knee joint. Postoperative X-ray films showed satisfactory fracture reduction and firm fixation. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 10.3 weeks). At last follow-up, Lachman test and anterior drawer test were negative. At last follow-up, Lysholm knee function score was 92.4±5.5, IKDC score was 91.6±4.4, and Tegner score was 5.2±1.1, which significantly improved when compared with preoperative scores ( t=-22.899, P<0.001; t=-29.870, P<0.001; t=-19.979, P<0.001).@*CONCLUSION@#Multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of ACL involving the anterior root of LM can not only fix the LM, but also effectively reduce and fix the avulsion fracture, which can obtain good effectiveness.


Assuntos
Masculino , Feminino , Humanos , Adulto , Ligamento Cruzado Anterior/cirurgia , Meniscos Tibiais/cirurgia , Fratura Avulsão/cirurgia , Estudos Retrospectivos , Lesões do Ligamento Cruzado Anterior/cirurgia , Resultado do Tratamento , Artroscopia , Fraturas da Tíbia/cirurgia , Articulação do Joelho/cirurgia , Suturas , Técnicas de Sutura
20.
Artigo em Chinês | WPRIM | ID: wpr-1009067

RESUMO

OBJECTIVE@#To compare the effectiveness between the posterolateral approach and the posterolateral combined posteromedial approaches in the treatment of Mason type 2B posterior malleolar fracture.@*METHODS@#A retrospective analysis was performed on the clinical data of 79 patients with posterior ankle fracture who met the selection criteria between January 2015 and January 2022. There were 62 cases of Mason 2B Pilon subtype and 17 cases of avulsion subtype. Among Mason 2B Pilon subtype patients, 35 were treated with posterolateral approach (group A), 27 patients were treated with combined approach (group B). There was no significant difference in gender, age, injured side, cause of injury, time from injury to operation, preoperative hospital stay, preoperative visualanalogue scale (VAS) score, and intraoperative internal fixation between the two groups ( P>0.05). All patients with Mason 2B avulsion subtype were treated by posterolateral approach, including 7 males and 10 females, aged from 25 to 68 years, with an average of 46.1 years. The operation time, intraoperative blood loss, postoperative hospital stay, and complications were recorded. The reduction quality was evaluated by Ovadia deals radiographic score, and the ankle function and pain were evaluated by VAS score, American Orthopaedic Foot and Ankle Society (AOFAS) score, and ankle range of motion.@*RESULTS@#Mason 2B Pilon subtype: There was no significant difference in operation time, intraoperative blood loss, postoperative hospital stay, and follow-up time between the two groups ( P>0.05). The radiological evaluation of Ovadia deals in group A was significantly worse than that in group B ( P<0.05). The VAS score in the two groups significantly improved at each time point after operation, and the VAS score and AOFAS score further improved with the extension of time after operation, and the differences were significant ( P<0.05). Except that the AOFAS score of group A was significantly lower than that of group B at last follow-up ( P<0.05), there was no significant difference in VAS score and AOFAS score between the two groups at other time points ( P>0.05). At last follow-up, the ankle range of motion in group A was significantly less than that in group B ( P<0.05). There was no significant difference in the incidence of sural nerve injury, deep tissue infection, limitation of toe movement, and traumatic ankle arthritis between the two groups ( P>0.05). Mason 2B avulsion subtype: The operation time was (119.47±20.61) minutes and the intraoperative blood loss was 50 (35, 55) mL. Seventeen patients were followed up 13-25 months, with an average of 18 months. The Ovadia deals score was excellent in 10 cases, good in 6 cases, and poor in 1 case at 1 week after operation, and the excellent and good rate was 94.1%. All fractures healed in 8-18 weeks with an average of 12.35 weeks. There were 1 case of sural nerve injury and 3 cases of traumatic ankle arthritis after operation. No deep tissue infection or limitation of toe movement occurred. The VAS score decreased significantly and AOFAS score increased significantly with time, and the differences were significant between different time points before and after operation ( P<0.05). The ankle range of motion at last follow-up was (56.71±2.47)°.@*CONCLUSION@#Compared with the posterolateral approach, the combined approach is a better choice for the treatment of Mason 2B Pilon subtype. If the posteromedial bone block does not affect the reduction of the medial malleolus, the posterolateral approach can achieve good effectiveness for Mason 2B avulsion subtype.


Assuntos
Feminino , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas do Tornozelo/cirurgia , Artrite/etiologia , Fixação Interna de Fraturas/efeitos adversos , Hemorragia Pós-Operatória , Estudos Retrospectivos , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA