Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1009117

RESUMO

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Assuntos
Humanos , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Fixação Intramedular de Fraturas , Fraturas da Tíbia/cirurgia , Fraturas do Planalto Tibial
2.
Rev. bras. ortop ; 59(2): 206-212, 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1565376

RESUMO

Abstract Objective To compare the functional outcomes of two circular external fixation techniques to treat complex fractures of the proximal end of the tibia. Materials and Methods The present is a retrospective cohort study with 51 patients who underwent surgical treatment for complex fractures of the tibial plateau with a circular external fixator. There were two groups of patients: 12 subjects underwent treatment with the classic assembly technique, and 39 subjects underwent treatment with the simplified technique. The variables analyzed included age, sex, injury mechanism, trauma energy, associated injuries, fixator type, time of fixator use, and clinical-radiographic outcomes. The classic technique mainly uses transfixing Kirschner wires, while the simplified one replaces the Kirschner wires with Schanz pins in the distal block of the circular external fixator. Result There were no statistically significant differences (p> 0.05) between the two groups concerning the clinical-radiographic outcomes, including fracture consolidation, quality of joint fracture reduction, range of motion, lower limbs residual discrepancy, and postoperative pain. Conclusion We suggest that the simplified technique, using Schanz pins instead of Kirschner wires, can be a viable and effective alternative to treat complex fractures of the proximal end of the tibia with a circular external fixator. This simplified approach can offer benefits, such as a lower infection rate and greater patient comfort, without compromising clinical and radiographic outcomes, thus justifying its use.


Resumo Objetivo Comparar os resultados funcionais entre duas técnicas de fixação externa circular utilizadas no tratamento de fraturas complexas da extremidade proximal da tíbia. Materiais e Métodos Trata-se de um estudo de coorte retrospectivo, com 51 pacientes submetidos ao tratamento cirúrgico de fraturas complexas do planalto tibial com fixador externo circular. Os pacientes foram divididos em dois grupos: 12 pacientes tratados com a técnica clássica e 39 pacientes tratados com a técnica simplificada. As variáveis analisadas incluíram idade, sexo, mecanismo da lesão, energia do trauma, lesões associadas, tipo de fixador, tempo de uso do fixador e resultados clínico-radiográficos. A técnica clássica lança mão principalmente de fios de Kirschner transfixantes, e a simplificada substitui os fios de Kirschner por pinos de Schanz no bloco distal do fixador externo circular. Resultados A partir da comparação das montagens, não encontramos diferenças estatisticamente significativas (p> 00,5) entre os dois grupos em relação aos resultados clínico-radiográficos, incluindo a consolidação da fratura, a qualidade da redução da fratura articular, a amplitude de movimento, a discrepância residual na medida dos membros inferiores e a dor do paciente no pós-operatório. Conclusão Sugerimos que a técnica simplificada, utilizando pinos de Schanz no lugar dos fios de Kirschner, pode ser uma alternativa viável e eficaz no tratamento de fraturas complexas da extremidade proximal da tíbia com fixador externo circular. Essa abordagem simplificada pode oferecer benefícios, como menor taxa de infecção e maior conforto para o paciente, sem comprometer os resultados clínicos e radiográficos, o que justifica, o seu uso.


Assuntos
Humanos , Fios Ortopédicos , Fixadores Externos , Técnica de Ilizarov , Fraturas do Planalto Tibial/terapia
3.
Rev. venez. cir. ortop. traumatol ; 55(1): 20-28, jun. 2023. graf, tab, ilus
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1512025

RESUMO

Las fracturas de meseta tibial compleja se asocian a traumatismo de alta energía, principalmente en accidentes de motocicleta, siendo un desafío para el cirujano ortopedista. En la década de 1970, Schatzker propuso una clasificación radiológica para las fracturas de la meseta tibial, que destacaba la morfología de los seis tipos principales. Las imágenes de tomografía computarizada y tridimensional, han cambiado la comprensión y el tratamiento de las fracturas de la meseta tibial. Recientemente, esa clasificación original se complementó con una más amplia; puesto que, se introdujo el fragmento en cuña dividida y la continuidad de la columna posterior como determinantes de la estabilidad articular y el papel fundamental que desempeña en el tratamiento de las fracturas de la meseta tibial, con ellos también la importancia de abordajes quirúrgicos que permitan la visualización posterior para una adecuada reducción. El estudio documenta las técnicas de fijación interna y abordajes posteriores realizadas en el IAHULA, valorando los resultados clínicos en cuanto a dolor y satisfacción del paciente, como consolidación, pseudoartrosis o falla en la técnica de osteosíntesis realizada. El resultado a partir de las escalas de evaluación de la AO y KOOS, arrojaron que, con un efecto excelentes se agrupa un 28,6% y bueno a un 42,9%, indicando la importancia de la fijación de la columna posterior, para prevenir artrosis postraumática temprana e inestabilidad articular(AU)


A complex fracture of the posterior tibial plateau are related to high energy traumatisms, mainly during motorcycle accidents, becoming a challenge to the ortopedic surgen. During the seventies, Stchatzker proposed a radiologic classification for the tibial plateau fractures that pointed the morphology of six main types. The computarized and tridimensional tomographic images have changed the comprehension and treatment of these fractures. Recently, the original classification was complemented with a more broaded approach due to the introduction of the fragment in divided crib and the continuity of the posterior column as factors determining the articular stability and the fundamental roll played in the treatment of fractures of the tibial plateau, as well as the important roll of surgical approaches that allow the posterior visualization for a correct reduction. This research documents the technics of internal fixation and posterior approach developed in the IAHULA, evaluating the clinic results about patients' pain level and comfort, as well as the radiologic findings of consolidation, pseudoarthrosis, or fail in the technic of osteosynthesis developed. The results from a point of view of the evaluation scales of the AO and KOOS, show 28.6% with excellent outcomes, and 42.9% with good outcomes, indicating the importance of the fixation of the posterior column to prevent early start of posttraumatic arthrosis and articular instability(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Coleta de Dados , Fixação Interna de Fraturas , Acidentes de Transporte Terrestre , Fraturas do Planalto Tibial
4.
Artigo em Chinês | WPRIM | ID: wpr-981607

RESUMO

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Assuntos
Masculino , Feminino , Humanos , Adulto , Estudos Retrospectivos , Perda Sanguínea Cirúrgica , Fraturas do Planalto Tibial , Resultado do Tratamento , Placas Ósseas , Fraturas da Tíbia/cirurgia , Articulação do Joelho , Fixação Interna de Fraturas , Osteotomia , Suporte de Carga
5.
Artigo em Chinês | WPRIM | ID: wpr-981688

RESUMO

OBJECTIVE@#To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.@*METHODS@#Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.@*RESULTS@#Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.@*CONCLUSION@#Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.


Assuntos
Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Fraturas do Planalto Tibial , Placas Ósseas , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Articulação do Joelho/cirurgia , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
6.
Artigo em Chinês | WPRIM | ID: wpr-981734

RESUMO

OBJECTIVE@#To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.@*METHODS@#From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).@*RESULTS@#All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).@*CONCLUSION@#The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fraturas do Planalto Tibial , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Placas Ósseas , Estudos Retrospectivos
7.
Artigo em Chinês | WPRIM | ID: wpr-1009023

RESUMO

OBJECTIVE@#To investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial.@*METHODS@#A study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference ( P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion.@*RESULTS@#① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups ( P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant ( P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant ( P>0.05). There was no significant difference in the operation time between groups ( P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups ( P<0.05); there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant ( P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups ( P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups ( P>0.05), while there was a significant difference in IL-6 between groups ( P<0.05).@*CONCLUSION@#Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.


Assuntos
Humanos , Ácido Tranexâmico/uso terapêutico , Perda Sanguínea Cirúrgica/prevenção & controle , Interleucina-6 , Estudos Prospectivos , Fraturas do Planalto Tibial , Fraturas da Tíbia/cirurgia , Trombose
8.
Chinese Journal of Traumatology ; (6): 334-338, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1009486

RESUMO

PURPOSE@#Electric scooters (e-scooters) have become an increasingly popular mode of public transportation in recent years. As the incidence of related injuries rises, it is important to understand specific fracture patterns unique to e-scooters and electric bikes (e-bikes) to help guide management. The purpose of this study was to review the prevalence and describe specific fracture patterns of e-scooter and e-bike related injuries at the busiest level 1 trauma center in the borough of Manhattan.@*METHODS@#Chart review to determine mechanism of injury was performed on all patients for whom an orthopedic consult was requested from 1/1/2021 to 12/31/2021. All patients whose injuries were sustained due to an e-scooter or e-bike were further reviewed for demographics, injury characteristics including fracture pattern, and definitive injury management. Any patients who had an orthopedic consult placed for a reason other than an acute injury were excluded. Descriptive statistics are reported as frequency (percentage) for categorical variables and means for continuous variables.@*RESULTS@#Of the 1815 orthopedic consults requested, 1357 (74.8%) were for acute injury management. Of those with acute injuries, 119 (8.8%) sustained 136 e-scooter or e-bike related injuries. There were 92 (77.3%) males at an average age of (33.8 ± 15.7) years. Approximately one-fifth of all patients presented in June 2021 (26, 21.8%). There was a 9.2% rate of open fractures. The 136 injuries were evenly split between the upper and lower extremities, with 57 (47.9%) upper extremity, 57 (47.9%) lower extremity injuries, and 5 (4.2%) concomitant upper and lower extremity injuries. The most common fracture patterns were ankle fractures (16, 11.7%), followed by tibial shaft (14, 10.2%), tibial plateau (13, 9.5%), and radial head fractures (11, 8.0%). There was a 33.3% incidence of associated posterior malleolar fractures in the spiral tibial shaft fractures, 31.0% of posterior malleolar involvement and 18.8% of isolated vertical medial malleolar fractures in the ankle fractures, and 61.5% of posterior comminution in the tibial plateau fractures.@*CONCLUSION@#E-scooter and e-bike related injuries have a high incidence of tibial shaft fractures, ankle fractures, tibial plateau fractures, and radial head fractures. There should be a high index of suspicion for posterior and medial involvement in lower extremity fractures sustained due to e-scooter or e-bikes. Identifying specific fracture patterns seen in e-scooter and e-bike related mechanisms will help guide management of these injuries.


Assuntos
Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Fraturas do Tornozelo , Centros de Traumatologia , Incidência , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Planalto Tibial , Estudos Retrospectivos , Fraturas da Tíbia/complicações , Fraturas do Rádio
9.
Rev. med. Urug ; 39(1): e401, 2023.
Artigo em Espanhol | LILACS, BNUY | ID: biblio-1431903

RESUMO

Objetivo: comparar si existe diferencia en resultados clínicos, radiológicos y funcionales con el uso de diferentes tipos de injertos óseos o sustitutos sintéticos, así como tiempo quirúrgico y consolidación para el tratamiento de fracturas de platillo tibial con hundimiento articular en pacientes mayores de 18 años. Material y método: se realizó una búsqueda sistematizada en bases de datos de literatura médica, PubMed, Lilacs, Scielo, Cochrane y portal Timbó. Se utilizaron términos "tibial plateau fracture", "bone grafting", "bone substitutes". Se incluyeron estudios comparativos en seres humanos, pacientes mayores de 18 años, fracturas de platillo tibial que asociaron hundimiento articular, en los cuales se realizó aporte de injerto óseo o material sintético. Artículos en español, inglés, portugués. Publicaciones enero 1980 y diciembre 2021. Se obtuvieron 10 artículos. Resultados: los tipos de injertos y sustitutos óseos encontrados fueron 10. Las muestras en sumatoria total 524 pacientes. La edad promedio fue 49 años. El promedio de seguimiento fue de 12 meses. Se dividieron los estudios en tres grupos: comparación entre injerto autólogo (IOA) e injerto alogénico, IOA con sustitutos sintéticos, y los que comparan sustitutos sintéticos entre sí. El aloinjerto y los sustitutos sintéticos demostraron no ser inferiores en resultados clínicos, funcionales e imagenológicos, mejorando los tiempos intraoperatorios y disminuyendo complicaciones en el sitio donante con respecto al IOA. Conclusiones: el IOA continúa siendo el gold standard a pesar de sus posibles complicaciones vinculadas al sitio donante. El aloinjerto y los sustitutos sintéticos representan una opción válida para tratar estas lesiones.


Objective: to find out whether there are clinical, radiological and functional differences when using different types of bone grafts or synthetic substitutes, as well as surgical times and consolidation to treat depressed tibial-plateau fractures in patients older than 18 years old. Method: a systematized search was conducted in medical literature, PubMed, Lilacs, Scielo, Cochrane and Timbó portal databases using the following terms: "tibial plateau fracture", "bone grafting", "bone substitutes". The study included comparative studies in human patients older than 18 years old with depressed tibial-plateau fractures who were treated with bone grafts or synthetic materials. Publications in Spanish, English and Portuguese, between January, 1980 and December, 2021 were included in the search, what resulted in 10 articles found. Results: there were 10 kinds of bone grafts and bone substitutes found. Samples added up to 524 patients. Average age was 49 years old. Average follow up was 12 months. Studies were divided into 3 groups: comparison between autologous bone grafts and allogenic bone grafts, comparison between autologous grafts and synthetic substitutes and studies comparing synthetic substitutes with one another. Allogenic grafts and synthetic grafts proved at least equivalent in terms of clinical, functional and imaging studies results, improving intraoperative times and reducing complications in donor site when compared to autologous grafts. Conclusions: autologous grafts continue to be the gold standard despite possible complications associated to the donor site, and allogenic grafts and synthetic substitutes constitute a valid option to treat these lesions.


Objetivo: comparar os resultados clínicos, radiológicos e funcionais com o uso de diferentes tipos de enxertos ósseos ou substitutos sintéticos, bem como tempo cirúrgico e consolidação para o tratamento de fraturas do platô tibial com colapso articular em pacientes com mais de 18 anos. Material e método: foi realizada busca sistemática nas bases de dados da literatura médica, PubMed, Lilacs, SciELO, Cochrane e portal Timbó. Utilizaram-se os termos "tibial plateau fracture", "bone grafting", "bone substitutes". Foram incluídos estudos comparativos incluindo seres humanos maiores de 18 anos e fraturas do platô tibial associadas a colapso articular, nas quais foi realizado enxerto ósseo ou sintético, publicados entre janeiro de 1980 e dezembro de 2021 em espanhol, inglês e português. Foram obtidos 10 artigos. Resultados: foram identificados 10 tipos de enxertos e substitutos ósseos. 524 pacientes com idade média de 49 anos foram estudados. O seguimento médio foi de 12 meses. Os estudos foram divididos em 3 grupos: comparação entre enxerto autólogo (IOA) e enxerto alogênico, IOA com substitutos sintéticos e substitutos sintéticos entre si. O aloenxerto e os substitutos sintéticos mostraram-se não inferiores nos resultados clínicos, funcionais e de imagem, melhorando os tempos intraoperatórios e reduzindo as complicações da área doadora em relação à IOA. Conclusões: o IOA continua a ser o padrão ouro apesar de suas possíveis complicações relacionadas ao local doador; tanto o aloenxerto como os substitutos sintéticos representam uma opção válida para tratar essas lesões.


Assuntos
Fraturas da Tíbia/cirurgia , Substitutos Ósseos , Fraturas do Planalto Tibial/cirurgia
10.
Rev. Assoc. Méd. Rio Gd. do Sul ; 66(1): 01022105, 20220101.
Artigo em Português | LILACS | ID: biblio-1425002

RESUMO

O presente trabalho avaliou os aspectos epidemiológicos das fraturas do platô tibial tratados cirurgicamente no Serviço de Ortopedia e Traumatologia do Hospital Santo Antônio, em Blumenau/SC. O trabalho analisou, retrospectivamente, por revisão de prontuários, 62 casos de fratura do planalto tibial tratados entre 2016-2018, nos quesitos idade, gênero, lateralidade, mecanismo lesional, lesões associadas, classificação de Schatzker e complicações. A média de idade foi de 44,8 anos ±14,4; entre os homens foi de 48 anos ±17,3; entre as mulheres de 43,7 anos ±13,3 anos. A incidência foi de 14,2 casos/105 hab/ano; por gênero, em homens 21,1 casos/105 hab/ano em relação à de mulheres, de 7,6 casos/105 hab/ano. O lado mais acometido foi o esquerdo, 57% dos casos, 40% à direita e 3% com bilateralidade. Mecanismos lesionais relatados: acidente de motocicleta 63%; queda de nível 11%; atropelamento 6%; agressão 5%; bicicleta 3%; desportivo 3%; carro 3%; própria altura 3% e quadriciclo 2%. Lesões associadas estiveram presentes em 33,9% da amostra, mais comuns nos membros inferiores, 24%. Optou-se pela classificação de Schatzker, com tipo VI 53%, tipo II 20%, tipo I 12% , tipo III 7%, tipo IV 5%, tipo V 3%. As complicações registradas nos prontuários totalizaram 43,5% da amostra. Perda parcial de amplitude de movimento foi a mais relatada, com 17,7% da amostra. Infecção da ferida operatória apresentou-se em 11,7% da amostra.


This study evaluated the epidemiological aspects of tibial plateau fractures surgically treated in the Hospital Santo Antônio orthopedics and traumatology service in Blumenau, SC, Brazil. The medical records of 62 cases of tibial plateau fracture treated between 2016 and 2018 were retrospectively analyzed regarding age, sex, laterality, mechanism of lesion, associated injuries, Schatzker classification, and complications. The mean age was 44.8 years (SD, 14.4) for the overall sample, 48 years (SD, 17.3) for men, and 43.7 years (SD, 13.3) for women. The incidence was 14.2 cases per 100,000 residents per year for the overall sample, 21.1 cases per 100,000 residents per year for men, and 7.6 cases per 100,000 residents per for women. The left side was more affected (57%) than the right (40%), and 3% were bilateral. The reported mechanisms of injury were: motorcycle accident (63%), fall from a height (11%), being run over by a vehicle (6%), assault (5%), bicycle accident (3%), sports (3%), car accident (3%), fall from standing height (3%) and quadricycle accident (2%). There were associated injuries in 33.9% of the sample, most often in the lower limbs (24%). Fracture types were classified according to the Schatzker system: type VI 53%, type II 20%, type I 12%, type III 7%, type IV 5%, type V 3%. Complications were reported in 43.5% of the sample, with partial loss of range of motion being the most common (17.7%). Surgical wound infection occurred in 11.7% of the sample.


Assuntos
Fraturas do Planalto Tibial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA