Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.779
Filtrar
1.
São Paulo; s.n; 20240301. 70 p.
Tese em Português | LILACS, BBO | ID: biblio-1532839

RESUMO

Objetivo: Esta revisão sistemática investigou se a precisão dos escaneamentos intraorais e modelos 3D com diferentes escâneres e softwares, é suficiente para os clínicos aceitarem e implementarem as novas tecnologias como critério de diagnóstico e planejamentos dos tratamentos. Material e métodos: Protocolo PROSPERO número CRD42020218151. Duas revisoras realizaram uma pesquisa avançada de banco de dados eletrônico, sem restrição de idioma ou data, no MEDLINE/PubMed; Embase; BVS/LILACS; Scopus; Cochrane Library; Google Scholar e Web of Science até janeiro de 2021. Os estudos foram escolhidos por título e resumo para triagem, de acordo com os seguintes critérios de inclusão: Estudos Clínicos in vivo e in vitro (pacientes, modelos de gesso de pacientes e manequins simulando bocas humanas) com os diferentes softwares e técnicas de escaneamento intraoral comparando a acurácia, fidelidade e/ou precisão como desfecho dos escaneamentos intraorais, dos modelos virtuais em 3D com modelos de gesso; com um mínimo de 5 pacientes escaneados sem limite de idade ou gênero; texto completo acessível; nos estudos de coorte, transversais e caso-controle. Após a leitura do texto completo os artigos foram excluídos de acordo com os seguintes critérios: 1) estudos com menos de 5 pacientes; 2) estudos em animais; 3) revisão sistemática, descrição de técnica, intervenções, protocolos; 4) escaneamentos por Ressonância Magnética ou Tomografia computadorizada; 5) estudos em que não foram utilizados scanners intraorais. Resultados. Dos 4410 estudos inicialmente identificados, 16 preencheram os critérios de inclusão. O guia PRISMA foi utilizado para redação da revisão e a ferramenta ROBINS-1 da Cochrane foi utilizada para análise de viés. Os estudos incluídos na sua maioria mostraram diferenças estatisticamente significativas entre os resultados das moldagens convencionais e digitais, porém também demonstraram que as diferenças não têm significância clínica. Conclusões: Esta revisão sistemática permitiu levantar dados que demonstraram que os escaneamentos intraorais não são superiores às moldagens convencionais, mas de acurácia equivalente com confiabilidade para o uso das imagens digitais conseguidas por escaneamento intraoral e dos modelos digitais provenientes destes escaneamentos.


Assuntos
Diagnóstico por Imagem , Modelos Dentários , Precisão da Medição Dimensional , Imageamento Tridimensional
2.
São Paulo; s.n; 20240222. 102 p.
Tese em Português | LILACS, BBO | ID: biblio-1531948

RESUMO

O presente estudo teve como objetivo avaliar a determinação do sexo por meio da análise geométrica e de mensurações a partir de imagens tridimensionais de dentes caninos, advindas de escaneamento intraoral, no Autodesk MeshMixer, bem como elaborar um roteiro prático para servir de guia na manipulação e coleta de dados nesse software. Trata-se de um estudo do tipo cego e transversal, dividido em duas etapas. Inicialmente, foram selecionadas imagens de 127 caninos (65 femininos e 63 masculinos) para a análise morfométrica geométrica, utilizando a marcação de 50 pontos, distribuídos em 27 pontos para contorno e 23 pontos para delimitação da forma das superfícies vestibular e lingual. Cada ponto de referência recebeu um valor para as coordenadas x, y e z, representando a sua posição. Na análise estatística dos dados foi utilizado um software específico para análise morfométrica geométrica, o MorphoJ, no qual foram importados os dados e submetidos à Análise Ajustada de Procrustes, Análise Discriminante e Análise da Variação Canônica. Não foram exibidas diferenças significativas para distribuição do sexo nas analises anteriores. Ainda, os dados relativos ao tamanho do centroide gerado no MorphoJ foram importados para o IBM SPSS Statistics 22.0 e submetidos ao teste t student, resultando em uma diferença estatística para o sexo. Para a aplicabilidade das mensurações digitais, foram utilizadas imagens de 345 caninos (191 femininos e 154 masculinos). Foram realizadas medidas das distâncias mesiodistais, vestibulolinguais, cervicoincisais (altura) e distâncias intercaninas de 5 pontos estabelecidos em cada canino (cúspide, cervical por vestibular e lingual, ponto máximo mesial e lingual). Todas as médias foram maiores para o sexo masculino e, com exceção da altura do elemento 33, apresentaram diferenças significativas para o sexo (p<0,05). As mensurações mesiodistais, vestibulolinguais e intercaninas (com exceção do ponto cervical por lingual), apresentaram uma boa acurácia, representadas por valores de áreas sobre a curva ROC maiores do que 0,7. O Autodesk MeshMixer apresentou-se como um ótimo auxiliar e de grande contribuição para análises dentro da Antropologia Forense. Apesar dos caninos serem elementos altamente dimórficos, para a análise morfométrica, não foram exibidas diferenças estatísticas na análise discriminante. Porém, o tamanho do centroide apresentou diferenças estatísticas e com médias maiores para o sexo masculino. As medidas realizadas nos dentes caninos apresentaram diferenças estatísticas para o sexo, com boas classificações na análise discriminante e com boas predições sexuais de acordo com os valores de especificidade e sensibilidade. A aplicabilidade de técnicas digitais de mensuração exibiu bons resultados, concordando esses dados obtidos com estudos que utilizaram as técnicas manuais de medida.


Assuntos
Análise para Determinação do Sexo , Antropologia Forense , Dente Canino , Imageamento Tridimensional
3.
Chinese Medical Journal ; (24): 329-337, 2024.
Artigo em Inglês | WPRIM | ID: wpr-1007634

RESUMO

BACKGROUND@#Pathological scars are a disorder that can lead to various cosmetic, psychological, and functional problems, and no effective assessment methods are currently available. Assessment and treatment of pathological scars are based on cutaneous manifestations. A two-photon microscope (TPM) with the potential for real-time non-invasive assessment may help determine the under-surface pathophysiological conditions in vivo . This study used a portable handheld TPM to image epidermal cells and dermal collagen structures in pathological scars and normal skin in vivo to evaluate the effectiveness of treatment in scar patients.@*METHODS@#Fifteen patients with pathological scars and three healthy controls were recruited. Imaging was performed using a portable handheld TPM. Five indexes were extracted from two dimensional (2D) and three dimensional (3D) perspectives, including collagen depth, dermo-epidermal junction (DEJ) contour ratio, thickness, orientation, and occupation (proportion of collagen fibers in the field of view) of collagen. Two depth-dependent indexes were computed through the 3D second harmonic generation image and three morphology-related indexes from the 2D images. We assessed index differences between scar and normal skin and changes before and after treatment.@*RESULTS@#Pathological scars and normal skin differed markedly regarding the epidermal morphological structure and the spectral characteristics of collagen fibers. Five indexes were employed to distinguish between normal skin and scar tissue. Statistically significant differences were found in average depth ( t = 9.917, P <0.001), thickness ( t = 4.037, P <0.001), occupation ( t = 2.169, P <0.050), orientation of collagen ( t = 3.669, P <0.001), and the DEJ contour ratio ( t = 5.105, P <0.001).@*CONCLUSIONS@#Use of portable handheld TPM can distinguish collagen from skin tissues; thus, it is more suitable for scar imaging than reflectance confocal microscopy. Thus, a TPM may be an auxiliary tool for scar treatment selection and assessing treatment efficacy.


Assuntos
Humanos , Cicatriz/diagnóstico por imagem , Pele/patologia , Colágeno , Imageamento Tridimensional/métodos
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 28-34, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1009104

RESUMO

OBJECTIVE@#To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.@*METHODS@#A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.@*RESULTS@#All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).@*CONCLUSION@#Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.


Assuntos
Humanos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Imageamento Tridimensional , Parafusos Ósseos , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Fraturas da Coluna Vertebral/cirurgia , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Complicações Pós-Operatórias , Lesões do Pescoço
5.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1536331

RESUMO

Para afrontar la reciente emergencia global por COVID-19, la comunidad científica y los profesionales de la salud en Cuba trabajan constantemente en el desarrollo de nuevos tratamientos y tecnologías que posibiliten el diagnóstico precoz de esta enfermedad, todo ello para facilitar el manejo general de esta pandemia.1) De ahí que se requiere el perfeccionamiento continuo de este proceso en correspondencia con los principios de la medicina, con una formación humanista, científica y con una visión integral de los problemas de salud como elemento esencial que caracteriza la formación de profesionales de la salud en territorio cubano donde la especialidad de Medicina General Integral constituye la principal disciplina integradora de contenidos, para ofrecer una atención preventiva, sistemática y continua al paciente a lo largo del tiempo, donde el médico en formación sea expresión de sus cualidades humanas. Coherente con esto, en 1984 se inició en Cuba la formación de especialistas en Medicina General Integral (MGI). Esta especialidad no tenía antecedentes en el país, por lo cual su propuesta constituye el perfeccionamiento del enfoque social de la medicina, que desde su implantación es la premisa básica del sistema de salud cubano. La formación de estos profesionales ocurre en la propia comunidad, con una alta calidad en los servicios que se brindan a la población.2 Para cumplir con esta función...(AU)


Assuntos
Humanos , Masculino , Feminino , Imageamento Tridimensional/métodos , COVID-19/epidemiologia , Cuba
6.
Int. j. morphol ; 41(4): 1107-1111, ago. 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1514329

RESUMO

SUMMARY: The aim of this research is to introduce the ideal lecture technique to the literature by explaining the anatomy of the skeletal system using the classical method, video-assisted method and 3D imaging techniques. The research was carried out with 180 students. The number of samples was determined by power analysis (a=0.05,b=0.20, effect size=0.25). Participants were pre-screened and divided into 4 groups with the closest group mean (group 1: control group: the group that did not take anatomy lessons, group 2: video-assisted anatomy education, group 3: 3D anatomy course, group 4: classical anatomy education group). The courses in the training groups were organised as 4 hours/day, 2 days/week for 5 weeks. At the end of the course, the students were re-examined and scaled to determine the difference in scores and self-efficacy between the groups. A one-way ANOVA test was performed because the data were normally distributed when comparing between groups. The mean scores were calculated as group 1=30.22±6.24, group 2=39.02±9.15, group 3=49.77±9.20 and group 4=59.28±8.95. In the post hoc comparison, in pairwise comparisons between all groups, the differences were highly significant (pgroup 3>group 2>group 1 (p<0.001). According to the results of this study, the laboratory method in skeletal anatomy teaching is the best alternative to 3D anatomy teaching.


El objetivo de esta investigación es introducir la técnica de lectura ideal en la literatura, explicando la anatomía del sistema esquelético, utilizando el método clásico, el método asistido por video y las técnicas de imágenes en 3D. La investigación se llevó a cabo con 180 estudiantes. El número de muestras se determinó mediante análisis de potencia (a=0,05, b=0,20, tamaño del efecto=0,25). Los participantes fueron preseleccionados y divididos en 4 grupos con la media de grupo más cercana (grupo 1: grupo de control: el grupo que no tomó lecciones de anatomía, grupo 2: educación de anatomía asistida por video, grupo 3: curso de anatomía 3D, grupo 4: grupo de educación en anatomía clásica). Los cursos en los grupos de formación se organizaron con 4 horas/día, 2 días/semana durante 5 semanas. Al final del curso, los estudiantes fueron reexaminados y escalados para determinar la diferencia en puntajes y autoeficacia entre los grupos. Se realizó una prueba de ANOVA de una vía debido a que los datos se distribuyeron normalmente al comparar entre grupos. Las puntuaciones medias se calcularon como grupo 1=30,22±6,24, grupo 2=39,02±9,15, grupo 3=49,77±9,20 y grupo 4=59,28±8,95. En la comparación post hoc, en comparaciones por pares entre todos los grupos, las diferencias fueron altamente significativas (pgrupo 3>grupo 2>grupo 1 (p<0,001). Según los resultados de este estudio, el método de laboratorio en la enseñanza de la anatomía esquelética es la mejor alternativa a la enseñanza de la anatomía en 3D.


Assuntos
Humanos , Imageamento Tridimensional , Educação Médica/métodos , Técnicas e Procedimentos Assistidos por Vídeo , Anatomia/educação , Aprendizagem , Sistema Musculoesquelético/anatomia & histologia , Inquéritos e Questionários , Análise de Variância , Avaliação Educacional , Sistema Musculoesquelético/diagnóstico por imagem
7.
Rev. Odontol. Araçatuba (Impr.) ; 44(2): 60-66, maio-ago. 2023. ilus
Artigo em Português | LILACS, BBO | ID: biblio-1428073

RESUMO

Sorriso gengival é comumente conhecido pela exposição excessiva das gengivas ao sorrir, acarretando assim na diminuição das coroas dos elementos. No que tange a etiologia dessa condição, ela se apresenta de maneiras diversas e sua identificação é fundamental para o desenvolvimento de um plano de tratamento eficaz. O planejamento clínico pode ser feito usando uma abordagem dinâmica e digital do sorriso, como softwares, exames de imagem, modelos virtuais 3D e guias cirúrgicos, melhorando a qualidade e precisão do tratamento, oferecendo diversos benefícios aos pacientes. Sendo assim esse estudo teve como objetivo demonstrar a importância dos processos digitais no planejamento e correção do sorriso gengival. Paciente queixou-se da desproporção do sorriso, caracterizado por coroas curtas nas regiões de pré-molares e incisivos ligadamente com a exposição excessiva da gengiva ao sorrir. Após estudos clínicos e de imagem, a etiologia foi diagnosticada como erupção passiva alterada, tipo I (fenótipo espesso). O tratamento de escolha foi o remodelamento gengival associado à osteotomia e osteoplastia obtendo assim uma maior precisão no tratamento, sendo confeccionado um guia cirúrgico duplo. Sendo assim, é possível contemplar que o planejamento digital permite uma maior previsibilidade da execução, compatibilidade em relação a expectativa do paciente e profissional, além da total individualização do caso, tornando os resultados mais favoráveis e exatos e minimizando as chances de iatrogenias(AU)


Gummy smile is commonly known for exposing the gums to the smile, thereby increasing the crowns elevation of the elements. Regarding a condition, it presents itself in different ways and its identification is fundamental for the development of a treatment plan. The clinician can be done using a dynamic and digital approach to image treatment, such as software, imaging exams, various 3D virtual models and elaborate guides, improving the quality and precision of treatment, offering benefits to patients. Therefore, this study aimed to demonstrate the importance of digital processes in planning and correcting the gummy smile. Patient complained of disproportion of the smile, facing the regions of premolar crowns and incisors of the smile, facing the exposure of the gingiva when smiling. After clinical and imaging exams, the diagnostic studies were diagnosed as passive eruption, type I (phenotype and specific). The choice of choice was remodeling associated with surgery treatment and surgery treatment, thus providing a greater precision in the treatment, being a double guide elaborated. Therefore, it is possible that the digital is possible a predictability of execution, compatibility in relation to patient and professional care, in addition to the greater possibility of individualization planning than it allows, making the results more planned as possibilities and exactly the iatrogenic(AU)


Assuntos
Humanos , Feminino , Adulto , Planejamento , Gengivoplastia , Osteotomia , Dente Pré-Molar , Coroas , Imageamento Tridimensional , Gengiva
8.
Rev. bras. ginecol. obstet ; 45(7): 409-414, July 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1507871

RESUMO

Abstract In this integrative review, we aimed to describe the records of time devoted by physicians to breast ultrasound in a review of articles in the literature, in order to observe whether the automation of the method enabled a reduction in these values. We selected articles from the Latin American and Caribbean Literature in Health Sciences (LILACS) and MEDLINE databases, through Virtual Health Library (BVS), SciELO (Scientific Electronic Library Online), PubMed, and Scopus. We obtained 561 articles, and, after excluding duplicates and screening procedures, 9 were selected, whose main information related to the guiding question of the research was synthesized and analyzed. It was concluded that the automation of breast ultrasound represents a possible strategy for optimization of the medical time dedicated to the method, but this needs to be better evaluated in comparative studies between both methods (traditional and automated), with methodology directed to the specific investigation of this potentiality.


Resumo Na presente revisão integrativa, objetivamos descrever os registros de tempo dedicado pelos médicos à ultrassonografia mamária em revisão de artigos da literatura, visando observar se a automação do método possibilitou redução destes valores. Selecionamos artigos nas bases de dados Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) e MEDLINE, através da Biblioteca Virtual em Saúde (BVS), Scientific Electronic Library Online (SciELO), PubMed e Scopus. Obtivemos 561 artigos e, após a exclusão de artigos duplicados e procedimentos de triagem, foram selecionados 9 artigos, cujas informações principais relativas à pergunta norteadora da pesquisa foram sintetizadas e analisadas. Foi concluído que a automação da ultrassonografia mamária representa uma possível estratégia de otimização do tempo médico dedicado ao método; porém, essa conclusão necessita ser melhor avaliada em estudos comparativos entre ambos os métodos (tradicional e automatizado), com metodologia direcionada à investigação específica desta potencialidade.


Assuntos
Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Mamária , Imageamento Tridimensional
9.
Int. j. morphol ; 41(3): 873-880, jun. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1514311

RESUMO

SUMMARY: Due to the complexity of head shape, limited 1D or 2D head anthropometry fail to fully capture its shape characteristics. Currently, there is limited research on clustering analysis of head shape from a shape difference perspective, especially for the head shape of Chinese people. Head shape is influenced by factors such as race, sex, and age, making it imperative to create a head shape database for Chinese individuals. In this study, three-dimensional head data of 339 Chinese young adult were collected, and the head shapes were clustered into 7 clusters using an improved k-medoids algorithm. The differences between clusters and the average head shape were further analyzed. It can be foreseen that the head shape database for Chinese young adult constructed in this study has important reference value for the ergonomic design of head-related products and head morphology research, among other fields.


Debido a la complejidad de la forma de la cabeza, la antropometría limitada de ésta, en 1D o 2D, no logra capturar completamente sus características de forma. Actualmente, existen estudios limitados sobre el análisis de agrupamiento de la forma de la cabeza, desde una perspectiva de diferencia de forma, especialmente en el caso de la población china. La forma de la cabeza está influenciada por factores como la raza, el sexo y la edad, por lo que resulta imperativo crear una base de datos sobre la forma de la cabeza de los individuos chinos. En este estudio, se recopilaron datos tridimensionales de la cabeza de 339 adultos jóvenes chinos, y las formas de la cabeza se agruparon en 7 grupos utilizando un algoritmo k-medoids mejorado. Las diferencias entre los grupos y la forma promedio de la cabeza se analizaron a profundidad. Se puede prever que la base de datos sobre la forma de la cabeza de adultos jóvenes chinos construida en este estudio, tiene un valor de referencia importante para el diseño ergonómico de productos relacionados con la morfología de la cabeza, entre otros campos.


Assuntos
Humanos , Adolescente , Adulto , Adulto Jovem , Antropometria , Imageamento Tridimensional , Cabeça/anatomia & histologia
10.
Int. j. morphol ; 41(2): 401-409, abr. 2023. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1440294

RESUMO

SUMMARY: Hyoid bone measurements have been proposed to vary between different genders and age groups. The aim of the study is to study hyoid morphometrics among Jordanian patients. 3D-CT scans of 637 patients were analyzed. Ten parameters of hyoid bone were measures, including the anteroposterior length, length of greater horns (right and left), height of greater horns (right and left), width of hyoid body, height of hyoid body, the distance between the midpoints of the posterior ends of the greater horns of the hyoid bone, the angle between right and left greater horns, and the distance of the hyoid bone to the vertebral column. Also, vertebral level, fusion rank, morphology of hyoid body lingula, and shape of hyoid bone were documented. All hyoid dimensions were longer in males, but greater horns angle was wider in females. In patients younger than 30 years, the parameters are the smallest with the widest angle. The distance from hyoid to vertebral column is higher in males (30-49) years of age. No fusion between hyoid body and greater horns was observed in patients younger than 10 years, but fusion (unilateral or bilateral) was found in only 73.2 % of patients ≥ 70 years. The hyoid was mostly at vertebra C3 level and "U" shaped. The lingula shape was mostly "Scar" in males (especially ≥ 50 years) and "Nothing" in females (especially < 50 years). The maximum growth of hyoid dimensions is before age of 30 years. Fusion between hyoid body and greater horns was not seen in patients younger than 10 years. Otherwise, the hyoid features failed to predict age or gender in our sample. Furthermore, 3D-CT scan is an excellent tool to assess the anatomy of head and neck region.


Se ha propuesto que las medidas del hueso hioides varían entre los diferentes sexos y grupos de edad. El objetivo del estudio fur estudiar la morfometría del hueso hioides en pacientes jordanos. Se analizaron tomografías computarizadas en 3D de 637 pacientes. Se midieron diez parámetros del hueso hioides, incluyendo la longitud anteroposterior, la longitud de los cuernos mayores (derecho e izquierdo), la altura de los cuernos mayores (derecho e izquierdo), el ancho del cuerpo hioides, la altura del cuerpo hioides, la distancia entre los puntos medios de los extremos posteriores de los cuernos mayores del hueso hioides, el ángulo entre los cuernos mayores derecho e izquierdo, y la distancia del hueso hioides a la columna vertebral. Además, se documentaron el nivel vertebral, el rango de fusión, la morfología de la língula del cuerpo hioides y la forma del hueso hioides. Todas las dimensiones del hioides fueron más largas en los hombres, pero el mayor ángulo de los cuernos fue más ancho en las mujeres. En pacientes menores de 30 años, los parámetros son los más pequeños con el ángulo más amplio. La distancia del hioides a la columna vertebral es mayor en el sexo masculino (30-49) años. No se observó fusión entre el cuerpo hioides y los cuernos mayores en pacientes menores de 10 años, pero se encontró fusión (unilateral o bilateral) en solo el 73,2 % de los pacientes ≥ 70 años. El hioides estaba mayormente al nivel de la vértebra C3 y en forma de "U". La forma de la língula era mayoritariamente "Cicatriz" en los hombres (especialmente ≥ 50 años) y "Nada" en las mujeres (especialmente < 50 años). El máximo crecimiento de las dimensiones del hioides es antes de los 30 años. La fusión entre el cuerpo hioides y los cuernos mayores no se observó en pacientes menores de 10 años. No obstante, las características del hueso hioides no pudieron predecir la edad o el sexo en nuestra muestra. Además, la tomografía computarizada 3D es una herramienta excelente para evaluar la anatomía de la región de la cabeza y el cuello.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Tomografia Computadorizada por Raios X/métodos , Imageamento Tridimensional/métodos , Osso Hioide/diagnóstico por imagem , Fatores Sexuais , Fatores Etários , Osso Hioide/anatomia & histologia
11.
Journal of Peking University(Health Sciences) ; (6): 343-350, 2023.
Artigo em Chinês | WPRIM | ID: wpr-986859

RESUMO

OBJECTIVE@#To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment.@*METHODS@#The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated.@*RESULTS@#DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points.@*CONCLUSION@#Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.


Assuntos
Imageamento Tridimensional , Software , Modelos Dentários
12.
Journal of Central South University(Medical Sciences) ; (12): 1267-1273, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1010351

RESUMO

Pelvic floor ultrasound can clearly visualize the position and morphology of pelvic floor organs, observe the pelvic organ prolapse in real-time, and quantify and analyze the degree of the levator ani muscle injury, which is the most common imaging method to assess the morphology and function of the levator ani muscle to date. The different ultrasound imaging techniques provide a variety of indicators, each with its own advantages and limitations.Furthermore, two-dimensional ultrasound is the basis of imaging, but it fails to detect cross-sectional images of the pelvic floor; three-dimensional ultrasound can acquire the axial plane of the levator hiatus; tomographic ultrasound imaging allows real-time observation of the levator ani muscle injury; shear wave elastography can provide a quantitative assessment of the contractility and elastic characteristics of the levator ani muscle in real-time. It is of great significance to summarize the basic principles of various ultrasound imaging techniques, summarize the ultrasound image characteristics of levator ani muscle and its hiatus in different populations and different states, and explore the cut-off values and diagnostic criteria-related ultrasound parameters for improving the diagnostic efficiency of pelvic floor ultrasound for levator ani muscle injury, leading to reducing missed diagnosis and misdiagnosis of lesions.


Assuntos
Humanos , Feminino , Diafragma da Pelve/patologia , Prolapso de Órgão Pélvico/patologia , Ultrassonografia/métodos , Imageamento Tridimensional
13.
Journal of Forensic Medicine ; (6): 129-136, 2023.
Artigo em Inglês | WPRIM | ID: wpr-981846

RESUMO

OBJECTIVES@#To investigate the reliability and accuracy of deep learning technology in automatic sex estimation using the 3D reconstructed images of the computed tomography (CT) from the Chinese Han population.@*METHODS@#The pelvic CT images of 700 individuals (350 males and 350 females) of the Chinese Han population aged 20 to 85 years were collected and reconstructed into 3D virtual skeletal models. The feature region images of the medial aspect of the ischiopubic ramus (MIPR) were intercepted. The Inception v4 was adopted as the image recognition model, and two methods of initial learning and transfer learning were used for training. Eighty percent of the individuals' images were randomly selected as the training and validation dataset, and the remaining were used as the test dataset. The left and right sides of the MIPR images were trained separately and combinedly. Subsequently, the models' performance was evaluated by overall accuracy, female accuracy, male accuracy, etc.@*RESULTS@#When both sides of the MIPR images were trained separately with initial learning, the overall accuracy of the right model was 95.7%, the female accuracy and male accuracy were both 95.7%; the overall accuracy of the left model was 92.1%, the female accuracy was 88.6% and the male accuracy was 95.7%. When the left and right MIPR images were combined to train with initial learning, the overall accuracy of the model was 94.6%, the female accuracy was 92.1% and the male accuracy was 97.1%. When the left and right MIPR images were combined to train with transfer learning, the model achieved an overall accuracy of 95.7%, and the female and male accuracies were both 95.7%.@*CONCLUSIONS@#The use of deep learning model of Inception v4 and transfer learning algorithm to construct a sex estimation model for pelvic MIPR images of Chinese Han population has high accuracy and well generalizability in human remains, which can effectively estimate the sex in adults.


Assuntos
Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Aprendizado Profundo , Imageamento Tridimensional , Pelve , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
14.
West China Journal of Stomatology ; (6): 483-490, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1007931

RESUMO

Using digital technologies in concurrently performing missing tooth implantation and preparation of remaining teeth is a solution to reduce the number of visits and improve efficiency. This paper proposes a digital process for simultaneously implanting and preparing teeth. It integrates implant surgical guide and 3D-printed tooth preparation guide into a single guide and completes guided implant placement and precise tooth preparation. Based on "repair-oriented" virtual implant planning, the implant surgical guide can improve the efficiency and predictability of implant placement, and its linear accuracy is about 1 mm. The tooth preparation guide precisely guides tooth preparation and restoration space visualization, ensuring the quality of the tooth preparation. The two guides have different design accuracy requirements, and thus their combination improves the overall guiding accuracy requirements. The concurrent application of the two guides minimizes the clinical operation time, number of visits, and economic burden of patients.


Assuntos
Humanos , Cirurgia Assistida por Computador , Implantação Dentária Endóssea , Impressão Tridimensional , Tecnologia , Preparo do Dente , Desenho Assistido por Computador , Implantes Dentários , Imageamento Tridimensional , Tomografia Computadorizada de Feixe Cônico
15.
West China Journal of Stomatology ; (6): 421-425, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1007923

RESUMO

OBJECTIVES@#This study aimed to explore the relationship between alveolar cleft and secondary nasal deformity post unilateral cleft lip repair in adults.@*METHODS@#A total of 27 patients aged 16-30 years old with unilateral secondary nasal deformity and alveolar cleft were included, 13 of whom underwent bone grafting. Spiral CT data of all preoperative and postoperative patients who had alveolar bone grafting were collected. Then, Mimics software was used for three-dimensional reconstruction to evaluate the correlation between the width, height, and volume of the alveolar cleft and those of the nasal deformity. The difference in nasal deformity before and after alveolar bone grafting was also explored.@*RESULTS@#The width of the alveolar cleft was positively correlated with the difference in bilateral nostril floor width (P<0.05). As the effective depth of the alveolar cleft increased, the sub-alare inclination angle largened (P<0.05). However, no significant difference was found in the nasal deformity between before and after alveolar bone grafting.@*CONCLUSIONS@#Alveolar cleft is closely related to secondary nasal deformities post unilateral cleft lip repair, especially nasal floor deformities. Alveolar bone grafting benefits adult patients for the improvement of secondary nasal deformities post unilateral cleft lip repair.


Assuntos
Humanos , Adulto , Adolescente , Adulto Jovem , Nariz/cirurgia , Fenda Labial/cirurgia , Rinoplastia/métodos , Imageamento Tridimensional , Resultado do Tratamento , Fissura Palatina/complicações
16.
China Journal of Orthopaedics and Traumatology ; (12): 487-489, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981719

RESUMO

OBJECTIVE@#To explore the technical aspects of the accuracy of cervical pedicle screw placement with O-arm guidance.@*METHODS@#The clinical data of 21 patients who underwent cervical pedicle screw fixation by O-arm real-time guidance from December 2015 to January 2020 were analyzed retrospectively. There were 15 males and 6 females, aged from 29 to 76 years old with an average of (45.3±11.5) years. The postoperative CT scan was utilized to evaluate the placement of the pedicle screw and classified according to the Gertzbein and Robbins classification.@*RESULTS@#A total of 132 pedicle screws were implanted in 21 patients, 116 at C3-C6 and 16 at C1 and C2. According to Gertzbein & Robbins classification, the overall breach rates were found to be 11.36% (15/132) with 73.33% (11 screws) Grade B, 26.67% (4 screws) Grade C, and no Grade D or E screw breaches. There were no pedicle screw placement related complications at final follow-up.@*CONCLUSION@#The application of O-arm real-time guidance technology can make cervical pedicle screw placement reliable. High accuracy and better intra-operative control can increase surgeon's confidence in using cervical pedicle instrumentation. Considering the high-risk nature of anatomical area around cervical pedicle and the possibility of catastrophic complications, the spine surgeon should have sufficient surgical skills, experience, ensures stringent verification of the system, and never relies solely on the navigation system.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Imageamento Tridimensional , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Parafusos Pediculares , Fusão Vertebral
17.
China Journal of Orthopaedics and Traumatology ; (12): 329-335, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981692

RESUMO

OBJECTIVE@#To explore correlation between femoral mechanical axis and Blumensaat line (FMBL) angle of knee joint (angle between Blumensaat line and femoral mechanical axis), α angle (angle between Blumensaat line and axis of distal femur in sagittal plane) on EOS biplane imaging and non-contact anterior cruciate ligament(ACL) injury, and evaluate angle for its accuracy in predicting the populations prone to non-contact ACL injury.@*METHODS@#From February 2018 to October 2020, EOS imaging and clinical data from 88 patients (176 knees) with unilateral non-contact ACL injury were retrospectively analyzed, including 53 males and 35 females, aged from 18 to 45 years old with an average of (30.3±6.2) years old, 48 patients on the left side and 40 patients on the right side. The patients were divided into ACL-affected group and ACL-health group according to side of ACL injuries, and 51 patients (51 knees) with non-ACL identified from EOS database were included in normal control group, including 28 males and 23 females, aged from 20 to 44 years old with an average of (31.6±5.5) years old, 26 patients on the left side and 25 patients on the right side. Full-length EOS imaging of skeleton extremitatis inferioris among three groups were reconstructed to 3D images of skeletal system with EOS software, and then FMBL angle and α angle were measured on the images. Univariate binary Logistic regression analysis was performed to determine the influence of the univariate(FMBL angle or α angle) on ACL status(normal or torn). And the angle cutoff value for univariate was selected based on receiver operating characteristics curve (ROC) to got the best accuracy.@*RESULTS@#There was no statistically significant difference in age, gender and side distribution between ACL-injured group and normal control group(P>0.05). Statistical analyses (one-way ANOVA) indicated no significant difference in FMBL angle between ACL-injured knee group (32.8±2.3)° and ACL-injured contralateral knee group(32.5±2.3)°(P>0.05), but the values between two groups were significantly lower than that in normal control group (37.0±2.0)°(P<0.001). There was no statistically significant difference in α angle among three groups (P>0.05). Univariate binary Logistic regression analysis demonstrated that FMBL angle was risk factor for non-contact ACL injury[OR=0.433, 95%CI(0.330, 0.569), P<0.001]. The area under ROC curve for FMBL angle was 0.909[95%CI(0.861, 0.958), P<0.001], and the sensitivity and specificity were 70.5% and 98.0% respectively, cut-off value was 33.7°.@*CONCLUSION@#FMBL angle formed by Blumensaat line and femoral mechanical axis is one of the risk factors for non-contact ACL injury and has good predictive accuracy. The general population with FMBL angle below 33.7° may be increased risk for ACL injury.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Estudos Retrospectivos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Ligamento Cruzado Anterior/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 551-555, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981630

RESUMO

OBJECTIVE@#To investigate the feasibility of MRI three-dimensional (3D) reconstruction model in quantifying glenoid bone defect by comparing with CT 3D reconstruction model measurement.@*METHODS@#Forty patients with shoulder anterior dislocation who met the selection criteria between December 2021 and December 2022 were admitted as study participants. There were 34 males and 6 females with an average age of 24.8 years (range, 19-32 years). The injury caused by sports injury in 29 cases and collision injury in 6 cases, and 5 cases had no obvious inducement. The time from injury to admission ranged from 4 to 72 months (mean, 28.5 months). CT and MRI were performed on the patients' shoulder joints, and a semi-automatic segmentation of the images was done with 3D slicer software to construct a glenoid model. The length of the glenoid bone defect was measured on the models by 2 physicians. The intra-group correlation coefficient ( ICC) was used to evaluate the consistency between the 2 physicians, and Bland-Altman plots were constructed to evaluate the consistency between the 2 methods.@*RESULTS@#The length of the glenoid bone defects measured on MRI 3D reconstruction model was (3.83±1.36) mm/4.00 (0.58, 6.13) mm for physician 1 and (3.91±1.20) mm/3.86 (1.39, 5.96) mm for physician 2. The length of the glenoid bone defects measured on CT 3D reconstruction model was (3.81±1.38) mm/3.80 (0.60, 6.02) mm for physician 1 and (3.99±1.19) mm/4.00 (1.68, 6.38) mm for physician 2. ICC and Bland-Altman plot analysis showed good consistency. The ICC between the 2 physicians based on MRI and CT 3D reconstruction model measurements were 0.73 [95% CI (0.54, 0.85)] and 0.80 [95% CI (0.65, 0.89)], respectively. The 95% CI of the difference between the two measurements of physicians 1 and 2 were (-0.46, 0.49) and (-0.68, 0.53), respectively.@*CONCLUSION@#The measurement of glenoid bone defect based on MRI 3D reconstruction model is consistent with that based on CT 3D reconstruction model. MRI can be used instead of CT to measure glenoid bone defects in clinic, and the soft tissue of shoulder joint can be observed comprehensively while reducing radiation.


Assuntos
Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Instabilidade Articular , Articulação do Ombro/diagnóstico por imagem , Luxação do Ombro , Imageamento por Ressonância Magnética/métodos
19.
Journal of Biomedical Engineering ; (6): 226-233, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981533

RESUMO

Magnetic resonance (MR) imaging is an important tool for prostate cancer diagnosis, and accurate segmentation of MR prostate regions by computer-aided diagnostic techniques is important for the diagnosis of prostate cancer. In this paper, we propose an improved end-to-end three-dimensional image segmentation network using a deep learning approach to the traditional V-Net network (V-Net) network in order to provide more accurate image segmentation results. Firstly, we fused the soft attention mechanism into the traditional V-Net's jump connection, and combined short jump connection and small convolutional kernel to further improve the network segmentation accuracy. Then the prostate region was segmented using the Prostate MR Image Segmentation 2012 (PROMISE 12) challenge dataset, and the model was evaluated using the dice similarity coefficient (DSC) and Hausdorff distance (HD). The DSC and HD values of the segmented model could reach 0.903 and 3.912 mm, respectively. The experimental results show that the algorithm in this paper can provide more accurate three-dimensional segmentation results, which can accurately and efficiently segment prostate MR images and provide a reliable basis for clinical diagnosis and treatment.


Assuntos
Masculino , Humanos , Próstata/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/diagnóstico por imagem
20.
Journal of Biomedical Engineering ; (6): 202-207, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981530

RESUMO

The registration of preoperative magnetic resonance (MR) images and intraoperative ultrasound (US) images is very important in the planning of brain tumor surgery and during surgery. Considering that the two-modality images have different intensity range and resolution, and the US images are degraded by lots of speckle noises, a self-similarity context (SSC) descriptor based on local neighborhood information was adopted to define the similarity measure. The ultrasound images were considered as the reference, the corners were extracted as the key points using three-dimensional differential operators, and the dense displacement sampling discrete optimization algorithm was adopted for registration. The whole registration process was divided into two stages including the affine registration and the elastic registration. In the affine registration stage, the image was decomposed using multi-resolution scheme, and in the elastic registration stage, the displacement vectors of key points were regularized using the minimum convolution and mean field reasoning strategies. The registration experiment was performed on the preoperative MR images and intraoperative US images of 22 patients. The overall error after affine registration was (1.57 ± 0.30) mm, and the average computation time of each pair of images was only 1.36 s; while the overall error after elastic registration was further reduced to (1.40 ± 0.28) mm, and the average registration time was 1.53 s. The experimental results show that the proposed method has prominent registration accuracy and high computational efficiency.


Assuntos
Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Algoritmos , Cirurgia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA