Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1009209

RESUMO

OBJECTIVE@#To analysis and determine MR signs of Harris score ARCO stages 2-4 in osteonecrosis of femoral head (ONFH).@*METHODS@#Thirty-four patients with ONFH of ARCO stages 2 to 4 who underwent routine MR, T2 mapping, 3D-SPACE sequence examination and Harris score were retrospectively collected from January 2019 to June 2020, and 3 patients were excluded, and 31 patients were finally included, including 23 males and 8 females, aged from 18 to 62 years old with an average of(40.0±10.8) years old. Among them 21 patients with bilateral femoral head necrosis, totally 52 cases, including 17 with ARCO stage 2 patients, 24 ARCO stage 3, and 11 ARCO stage 4. MR imaging signs (femoral head collapse depth, ONFH index, bone marrow edema, hyperplasia, grade and T2 value of cartilage injury, and joint effusion) were scored and measured on the picture archiving and communication system (PACS) workstation, and the cartilage quantitative parameter T2 value was calculated and measured on Siemens postprocessing workstation. Pearson correlation analysis was used to evaluate the correlation between various MR signs and Harris score, and then multiple linear regression analysis was used to examine impact of MR signs on Harris hip score.@*RESULTS@#Femoral head collapse depth(r=-0.563, P=0.000), grade of cartilage injury(r=-0.500, P=0.000), and joint effusion (r=-0.535, P=0.000) were negatively correlated with Harris score by Pearson correlation analysis. Multiple linear regression analysis showed that joint effusion(β=-6.198, P=0.001) and femoral head collapse depth(β=-4.085, P=0.014) had a significant negative impact on Harris hip score.@*CONCLUSION@#Femoral head collapse depth and joint effusion both had significant negative relationship with Harris hip score. It is recommended to routinely evaluate femoral head collapse depth and joint effusion quantitatively and gradedly, so as to efficiently and accurately assist clinical diagnosis and treatment.


Assuntos
Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Estudos Retrospectivos , Cabeça do Fêmur/diagnóstico por imagem , Transplante Ósseo/métodos , Imageamento por Ressonância Magnética , Resultado do Tratamento
3.
Artigo em Inglês | WPRIM | ID: wpr-101617

RESUMO

BACKGROUND: Early stage osteonecrosis of the femoral head (ONFH) has many treatment options including core decompression with implantation of a tantalum rod. The purpose of this study was to evaluate clinical and radiological outcomes and potential complications during conversion total hip arthroplasty (THA) in such patients. METHODS: Six male patients (8 hips) underwent THA subsequent to removing a tantalum rod (group I) from April 2010 to November 2011. We retrospectively reviewed the medical records of these patients. We enrolled 12 age- and sex-matched patients (16 hips) during the same period, who had undergone primary THA without a previous operation as the control group (group II). All patients were followed for at least 3 years. We checked the Harris hip score (HHS), operative time, and volume of blood loss. Radiological results, including inclination, anteversion of the acetabular cup, presence of periprosthetic osteolysis, and subsidence of femoral stem were checked at the last follow-up. RESULTS: The mean preoperative HHS values were 56.5 (range, 50 to 62) and 59.1 (range, 42 to 70) in groups I and II, respectively. The HHS improved to 96.0 (range, 93 to 100) and 97.6 (range, 93 to 100), respectively, at the 3-year follow-up (p = 0.172). Mean operation time was 98.8 minutes (range, 70 to 120 minutes) in group I and 77.5 minutes (range, 60 to 115 minutes) in group II (p = 0.006). Total blood loss volumes were 1,193.8 mL (range, 960 to 1,360 mL) and 944.1 mL (range, 640 to 1,280 mL) in groups I and II, respectively (p = 0.004). No significant differences in inclination or anteversion of acetabular cup and no evidence of osteolysis or subsidence of the femoral stem were reported in either group in radiological follow-up results. However, one case of squeaking occurred in group I during the follow-up. CONCLUSIONS: The two groups showed no clinical or radiological differences except extended operative time and increased blood loss. However, the incidence of squeaking (1 of 8 hips) was higher, as compared to the control group or previously reported values.


Assuntos
Adulto , Humanos , Masculino , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Descompressão Cirúrgica/efeitos adversos , Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Tantálio/uso terapêutico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Yonsei Medical Journal ; : 510-515, 2013.
Artigo em Inglês | WPRIM | ID: wpr-149918

RESUMO

PURPOSE: There are no reports about bone graft and cell therapy for the osteonecrosis of femoral head (ONFH). We prospectively evaluated the clinical results of auto-iliac cancellous bone grafts combined with implantation of autologous bone marrow cells for ONFH. MATERIALS AND METHODS: Sixty-one hips in 52 patients with ONFH treated with bone graft and cell therapy were enrolled, and the average follow-up of the patients was 68 (60-88) months. Necrotic lesions were classified according to their size by the Steinberg method and location of necrosis. RESULTS: At the last follow-up, the percentage of excellent or good results was 80% (12/15 hips) in the small lesion group, 65% (17/26 hips) in the medium size group, and 28% (6/20 hips) in the large size group. The procedures were a clinical success in 4 of 5 hips (80%) of stage I, 23 of 35 hips (65.7%) of stage II, 7 of 18 hips (38.9%) of stage III, and 1 of 3 hips (33.3%) of stage IV grade, according to the Association Research Circulation Osseous grading system. Among the 20 cases with large sized necrotic lesions, 17 cases were laterally located and this group showed the worst outcomes, with 13 hips (76.5%) having bad or failed clinical results. CONCLUSION: The results of the present study suggested that patients who have a large sized lesion or medium sized laterally located lesion would not be good candidates for the head preserving procedure. However, for medium sized lesions, this procedure generated clinical results comparable to those of other head preserving procedures.


Assuntos
Humanos , Autoenxertos/diagnóstico por imagem , Transplante Ósseo , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Ílio/transplante , Transplante de Células-Tronco Mesenquimais , Transplante Autólogo , Resultado do Tratamento
5.
Yonsei Medical Journal ; : 186-192, 2012.
Artigo em Inglês | WPRIM | ID: wpr-145833

RESUMO

PURPOSE: We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS: One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems were followed for more than 10 years. Ninety-four hips in 80 patients were available for clinical and radiologic analysis. The mean age at the time of surgery was 47 years, and the mean duration of follow-up was 14.3 years. RESULTS: The mean Harris hip scores had improved from 58 points to 88 points at the time of the 10-year follow-up. Activity-related thigh pain was reported in nine hips (10%). At the last follow-up, 93 stems (99%) were biologically stable and one stem (1%) was revised because of loosening. No hip had distal diaphyseal osteolysis. Proximal femoral stress-shielding was reported in 86 hips (91%). We found no significant relationship between collar-calcar contact and thigh pain, stem fixation status, or stress-shielding. The cumulative survival of the femoral stem was 99% (95% confidence interval, 98-100%) after 10 years. CONCLUSION: The long-term results of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels were satisfactory; however, the high rate of proximal stress-shielding and the minimal effect of the collar indicate the need for some changes in the stem design.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Fraturas do Colo Femoral/diagnóstico por imagem , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Seguimentos , Prótese de Quadril , Osteoartrite do Quadril/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
6.
Benha Medical Journal. 2006; 23 (3): 733-748
em Inglês | IMEMR | ID: emr-105052

RESUMO

Avascular bone necrosis [AVN] of femoral head in renal allograft recipients receiving corticosteroid therapy is a disabling problem in this unique group of patients. We report the results of treatment of sixty two hips with radiologically proven AVN in 47 recipients who were categorized into two groups according to the grade of AVN. Group I included early AVN, positive MRI but normal X-ray. and that was encountered in 31 hips in 22 recipients [9 patients with bilateral hip affection]. while group II included advanced AVN and was encountered in 31 hips in 25 recipients [6 patients with bilateral hip affection]. The mean age in group I was 29 years [range 20-49 years]. while in group II was 30 [range 20-42 years]. Core decompression was performed in all hips of group I, while patients in, group II were subjected to either cemented or cementless total hip replacement. The average follow-up was 36 months [range 10-42 months]. The results were assessed by clinical and imaging follow-up examinations. MRI [for group I patients] and plain radiographic examinations were repeated within 4-12 months duration in group I, the outcome was considered successful if there was no clinical or radiographic progression of the operated hips. hence any need for subsequent surgery during the duration of the study. The success rate of core decompression was 82% in early AVN. In group II: Harris hip score improved from average 35 points preoperatively to 94 points postoperatively with excellent and good results in all patients [100%]. We believe that. although total hip arthroplasty would be the treatment of choice in disabling osteonecrosis in renal transplant recipient. early detection of AVN by MRI warrants special attention to avoid the potential hazards of total hip replacement in this group of immunocompromized patients


Assuntos
Humanos , Masculino , Feminino , Transplante Homólogo/efeitos adversos , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Imageamento por Ressonância Magnética , Seguimentos , Artroplastia de Quadril
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA