Your browser doesn't support javascript.
loading
Шоу: 20 | 50 | 100
Результаты 1 - 20 de 51
Фильтр
1.
Braz. oral res. (Online) ; 31: e2, 2017. tab, graf
Статья в английский | LILACS | ID: biblio-839510

Реферат

Abstract An early childhood carie (ECC) is an extremely destructive form of tooth decay. The aim of this study was to investigate the action of ozone (O3), and the association of sodium fluoride (NaF) with chlorhexidine (CHX) on bacteria related to ECC. Overnight culture of the bacteria was performed. On exponential phase the suspension was adjusted (101-108 CFU/mL). A drop (10μL) of each concentration of bacteria was applied on sheep blood agar plates and treated with O3 (2, 20, 200, and 2,000 ppm); after 18 hours, recovery analysis of CFU verified the reduction of bacterial activity. For NaF-CHX, sterile 96-well plates were prepared and divided into groups: G1 (150 µL TSB); G2 (20 µL of bacteria + 25 µL CHX + 25 µL NaF); and G3 (150 µL TSB + 20 µL of bacteria + 50 µL water). The plates were verified by analysis of the optical density (0, 12, 14, 16, and 18 hours). The data from O3 test were submitted to ANOVA and Tukey’s test (p < 0.05). For the data from NaF-CHX, the ANOVA 2-way and Bonferroni’s test (p < 0.05) were used. The number of CFU/mL showed death > 3log10 (99.9%) for all bacteria (ozone ≥ 20ppm), while the combination of NaF-CHX was more effective (p < 0.001) compared to each substance tested alone and the control group. The antimicrobial agents tested were able to inhibit all bacteria tested; O3 seemed to be a good alternative for controlling progression of carious lesions, while the association of NaF-CHX showed to be a good antimicrobial with easy and inexpensive application.


Тема - темы
Ozone/pharmacology , Sodium Fluoride/pharmacology , Cariostatic Agents/pharmacology , Chlorhexidine/pharmacology , Dental Caries/prevention & control , Anti-Infective Agents/pharmacology , Streptococcus mutans/growth & development , Streptococcus mutans/drug effects , Time Factors , Colony Count, Microbial , Reproducibility of Results , Analysis of Variance , Enterococcus faecalis/growth & development , Enterococcus faecalis/drug effects , Lactobacillus acidophilus/growth & development , Lactobacillus acidophilus/drug effects
2.
Braz. oral res. (Online) ; 30(1): e168, 2016. tab, graf
Статья в английский | LILACS | ID: biblio-951995

Реферат

Abstract The purpose of this study was to perform a microcomputed tomographic evaluation of the radioprotective effect of resveratrol on the volume of mandibular incisors of irradiated rats. A second aim was to make a quantitative assessment of the effect of x-ray exposure on these dental tissues. Twenty adult male rats were divided into four groups: control, irradiated control, resveratrol, and irradiated resveratrol. The resveratrol groups received 100 mg/kg of resveratrol, whereas the irradiated groups were exposed to 15 Gy of irradiation. The animals were sacrificed 30 days after the irradiation procedure, and their mandibles were removed and scanned in a microcomputed tomography unit. The images were loaded into Mimics software to allow segmentation of the mandibular incisor and assessment of its volume. The results were compared by One-way ANOVA and Tukey's post hoc test, considering a 5% significance level. The irradiated groups showed significantly diminished volumes of the evaluated teeth, as compared with the control group (p < 0.05). The resveratrol group presented higher values than those of the irradiated groups, and volumes similar to those of the control group. High radiation doses significantly affected tooth formation, resulting in alterations in the dental structure, and thus lower volumes. Moreover, resveratrol showed no effective radioprotective impact on dental tissues. Future studies are needed to evaluate different concentrations of this substance, in an endeavor to verify its potential as a radioprotector for these dental tissues.


Тема - темы
Animals , Male , Radiation Injuries, Experimental/prevention & control , Radiation-Protective Agents/pharmacology , Stilbenes/pharmacology , X-Ray Microtomography/methods , Incisor/radiation effects , Odontogenesis/radiation effects , Radiation Injuries, Experimental/diagnostic imaging , Time Factors , Rats, Wistar , Imaging, Three-Dimensional , Resveratrol , Incisor/drug effects , Incisor/diagnostic imaging , Mandible/drug effects , Mandible/radiation effects , Mandible/diagnostic imaging
3.
Rev. latinoam. enferm. (Online) ; 24: e2701, 2016. tab, graf
Статья в английский | LILACS, BDENF | ID: biblio-960959

Реферат

Abstract Objective: to assessed the prevalence of diabetes mellitus (DM) and drug abuse in mothers of children with orofacial clefts (OFC). Methods: 325 women who had children (0-3y) with clefts were interviewed. Data regarding type of diabetes, use of legal/illegal drugs during pregnancy, waist girth and fasting blood sugar at the first prenatal consult were collected. Results: twenty seven percent of the women had DM, out of these, 89% had gestational DM, 5,5% type 1 DM and 5,5% type 2 DM. The prevalence of DM in mothers of children with OFC was 27%, it is significantly higher than the average Brazilian population which is 7.6% (p<0.01) (OR=4.5, 95%CI=3.5-5.8). Regarding drug abuse during pregnancy, 32% of the mothers used drugs and a significant positive correlation was observed between drug abuse and the occurrence of clefts and other craniofacial anomalies (p=0.028) (OR=2.87; 95%CI=1.1-7.4). Conclusions: DM and drug abuse during pregnancy increases the risk for OFC and related anomalies and early diagnosis of DM and prevention of drug abuse, especially in pregnant women, should be emphasized.


Resumen Objetivos: esta investigación estableció la prevalencia de diabetes mellitus (DM) y el abuso de drogas en madres de niños con malformaciones creaneofaciales (MCF). Métodos: 325 mujeres que tuvieron hijos (0-3 años) con malformaciones fueron entrevistadas. Se obtuvieron datos referentes a: tipo de diabetes; uso de drogas lícitas o ilícitas durante el embarazo; circunferencia de la cintura; y, glucemia en ayunas en la primera consulta prenatal. Resultados: el veintisiete por ciento de las mujeres tenían DM. Entre estas, el 89% tuvieron DM gestacional, el 5,5% DM tipo 1 y el 5,5% DM tipo 2. La prevalencia de DM en madres de hijos con MCF fue de 27%. Esto es significativamente más alto que el promedio de la población brasileña afectada por esa enfermedad, que es de 7,6% (p<0.01) (OR=4,5, 95%IC=3,5-5,8). Observando el abuso de drogas durante el embarazo, el 32% de las madres había utilizado drogas y una correlación positiva significativa fue observada entre el abuso de drogas y la ocurrencia de hendiduras y otras malformaciones craneofaciales (p=0,028) (OR=2,87; 95%IC=1,1-7,4). Conclusiones: la DM y el abuso de drogas durante el embarazo aumentan el riesgo de MCF y de anomalías relacionadas; se enfatiza la importancia del diagnóstico precoz de DM y la prevención del abuso de drogas, especialmente entre las mujeres embarazadas.


Resumo Objetivos: avaliar a prevalência de diabetes mellitus (DM) e o uso de drogas em mães de crianças com fissuras orofaciais (FOF). Método: 325 mulheres que tiveram filhos (0-3 anos) com fissuras foram entrevistadas. Os dados referentes tipo de diabetes, uso de drogas lícitas / ilícitas durante a gravidez, circunferência abdominal e glicemia em jejum na primeira consulta pré-natal foram coletados. Resultados: vinte e sete por cento das mulheres tinham DM. Destes, 89% tinham DM gestacional, 5,5% DM tipo 1 e 5,5% DM tipo 2. A prevalência de DM em mães de crianças com FOF foi de 27%, significativamente mais elevado que a média da população brasileira que é de 7,6% (p <0,01) (OR = 4,5, IC de 95% = 3,5-5,8). Com relação ao uso de drogas, 32% das mães eram usuárias drogas durante a gravidez e uma correlação positiva foi observada entre o uso de drogas e a ocorrência de FOF e anomalias relacionadas (p = 0,028) (OR = 2,87; IC95% = 1,1-7,4). Conclusões: DM e uso de drogas durante a gravidez aumentam o risco de FOF e anomalias relacionadas e o diagnóstico precoce de DM e a prevenção do uso de drogas, especialmente em mulheres grávidas, devem ser enfatizados.


Тема - темы
Humans , Female , Pregnancy , Infant, Newborn , Infant , Child, Preschool , Adolescent , Adult , Middle Aged , Young Adult , Pregnancy in Diabetics , Cleft Lip/epidemiology , Cleft Palate/epidemiology , Diabetes, Gestational , Substance-Related Disorders/complications , Diabetes Complications/complications , Brazil , Prevalence , Cross-Sectional Studies , Risk Factors
4.
RFO UPF ; 14(2): 132-138, maio-ago. 2009. ilus, tab
Статья в португальский | LILACS | ID: lil-527862

Реферат

O objetivo deste estudo foi avaliar a microinfiltração e a resistência de união à dentina por meio do teste de microtração em restaurações classe III, usando dois sistemas adesivos - o autocondicionante Clearfil SE Bond®/ Kuraray (SE) e o sistema de condicionamento ácido total Single Bond®/3MEspe (SB) -, submetidas (C) ou não à ciclagem térmica (NC). Foram preparadas duzentas cavidades classe III em incisivos bovinos, divididas em quatro grupos: G1:SB/NC; G2:SB/C; G3:SE/NC; G4:SE/C. Após restaurados, os G1 e G3 foram imersos em solução corante e os dentes, levados à cortadora metalográfica, sendo as restaurações seccionadas no sentido V-L em fatias de 0,7 a 0,8 mm. Essas secções foram, primeiramente, avaliadas quanto à penetração de corante e, em seguida, submetidas ao teste de microtração (área adesiva: 1 mm2), confeccionando-se espécimes em forma de "hourglass". Para os G2 e G4 as amostras foram submetidas a 2000 ciclos térmicos (5-55 ºC) e, após, sofreram os mesmos procedimentos descritos para os G1 e G3. Quanto à microinfilitração, os resultados foram analisados pelo teste de Kruskal-Wallis (p < 0,05), não demonstrando diferença estatisticamente significativa entre os grupos. Os dados de microtração (MPa) foram submetidos ao teste Anova dois fatores e Tukey (p < 0,05): G1:18,80a; G2:19,78a; G3:13,29c; G4:6,23b. Independentemente da ciclagem térmica, os dois adesivos apresentaram a mesma permissibilidade de microinfiltração. O desafio térmico influenciou negativamente na força de adesão do autocondicionante SE, mas não interferiu nos valores do SB.


The aim of this study was to evaluate the microleakageand μTBS of class III composite resin restoration using two bonding systems – the self etching primer Clearfil SE Bond/Kuraray (SE) and the one-bottle Single Bond/3MEspe (SB) subjected (C) or not (NC) to thermal cycles. 200 box-type class III cavities were prepared on surfaces of bovine incisors and divided into 4 groups: G1:SB/NC; G2:SB/C; G3:SE/NC; G4:SE/C. After the restorative procedures, G1 and G3 were immersed in a dye solution and the restorations were sectioned perpendicular to the cervical margin interface into 0.7± 0.2 mm thick slabs. These sections were first evaluated according to dye penetration and then the slabs were further trimmed at the interface to produce samples with a hourglass shape (cross-sectional surfacearea of 1mm2) to μTBS test evaluation. The samples ofG2 and G4 were thermocycled (2.000 cycles, 5-55 oC) and then subjected to the same procedures described for G1 and G3. The microleakage results were analyzed by the de Kruskal-Wallis (p < 0.05) test, and no differences were observed among groups. The μTBS means were analyzed by the Anova 2 way and Tukey test:G1:18.80a; G2:19.78a; G3:13.29c; G4:6.23b. Regardless the thermal cycles, both adhesive systems present the same microleakage results. However, for SE thermal cycling had adversely affected the bond strength values,but for SB no differences were observed.


Тема - темы
Animals , Cattle , Dental Leakage , Composite Resins , Dental Restoration, Permanent , Dental Enamel , Shear Strength , Materials Science
5.
Rev. odonto ciênc ; 24(3): 305-308, July-Sept. 2009. tab
Статья в английский | LILACS, BBO | ID: biblio-873864

Реферат

Purpose: This study aimed to provide guidelines about the coefficient of variation (CV) of shear (SBS) and microtensile (µTBS) bond strength to enamel and dentin. Methods: A search of the English language peer-reviewed literature was conducted using the PubMed database from 2000 to 2009. Only bond strength studies (SBS and µTBS) that have tested both enamel and dentin substrates were selected. The following information was gathered from the 103 papers selected: groups mean and standard deviation (SD), repetition number, and type of statistical analysis. The CV of each study was calculated by using its mean and SD values, the normality of shear and microtensile CV was analyzed using Shapiro-Wilk test, and a CV classification was established for each variable. Results: According to the CV classification proposed, values below 10.3% and 11.3% could be considered low for shear bond strength to enamel and dentin, respectively; and values below 15.4% to enamel and 16.4% to dentin could be considered low for the microtensile test. Values higher than 46.8% and 62.1% (shear bond strength to enamel and dentin) and 45.9% and 45.5% (microtensile bond strength to enamel and dentin) showed a very high variability. Conclusion: Such classification can be useful for future experiments on adhesive materials to estimate statistical power and data precision.


Objetivo: Este estudo se propôs a fornecer diretrizes sobre o coeficiente de variação (CV) de ensaios de resistência ao cisalhamento (SBS) e à microtração (µTBS) em esmalte e dentina.Metodologia: Uma busca de artigos publicados de 2000 a 2009 foi realizada na base de dados PubMed. Apenas estudos (SBS e µTBS) que testaram esmalte e dentina foram considerados elegíveis. As seguintes informações foram coletadas dos 103 artigos selecionados: média e desvio-padrão (DP) dos grupos, número de repetições e análise estatística. O CV de cada estudo foi calculado utilizando-se média e DP, a normalidade dos CV de cada teste foi analisada pelo teste de Shapiro-Wilk e classificações para os CV foram estabelecidas. Resultados: De acordo com a classificação proposta, valores menores que 10,3% e 11,3% são baixos para estudos de cisalhamento ao esmalte e dentina, respectivamente. Para estudos de microtração, baixa variabilidade é obtida com CV menores que 15,4% (esmalte) e 16,4% (dentina). Experimentos com CV maiores que 46,8% e 62,1% (cisalhamento no esmalte e dentina) e 45,9% e 45,5% (microtração no esmalte e na dentina) apresentam variabilidade muito alta. Conclusão: Esta classificação pode ser útil para futuros experimentos em Odontologia adesiva para estimar o poder estatístico dos testes e a precisão dos dados.


Тема - темы
Dental Enamel , Dentin , Shear Strength , Data Interpretation, Statistical , Tensile Strength
6.
Braz. oral res ; 23(3): 333-339, 2009. graf, tab
Статья в английский | LILACS | ID: lil-530273

Реферат

The aim of this study was to compare different treatments for dentin hypersensitivity in a 6-month follow-up. One hundred and one teeth exhibiting non carious cervical lesions were selected. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment (baseline), immediately after topical treatment, after 1 week, 1, 3 and 6 months. Teeth were randomly assigned to five groups (n = 20): G1: Gluma Desensitizer (GD); G2: Seal&Protect (SP); G3: Oxa-gel (OG); G4: Fluoride (F); G5: Low intensity laser-LILT (660 nm/3.8 J/cm²/15 mW). Analysis was based on the non-parametric Kruskal-Wallis test that demonstrated statistical differences immediately after the treatment (p = 0.0165). To observe the individual effects of each treatment, data was submitted to Friedman test. It was observed that GD and SP showed immediate effect after application. Reduction in the pain level throughout the six-month follow-up was also observed. In contrast, LILT presented a gradual reduction of hypersensitivity. OG and F showed effects as of the first and third month respectively. It can be concluded that, after the 6-month clinical evaluation, all therapies showed lower VAS sensitivity values compared with baseline, independently of their different modes of action.


Тема - темы
Humans , Dentin Desensitizing Agents/administration & dosage , Dentin Sensitivity/therapy , Low-Level Light Therapy/methods , Administration, Topical , Random Allocation , Treatment Outcome
7.
Rev. ABO nac ; 14(4): 248-253, ago.-set. 2006. ilus
Статья в португальский | LILACS, BBO | ID: lil-544740

Реферат

O clareamento dental oferece ao cirurgião-dentista uma forma conservativa, simples e econômica para obter estética através da mudança de cor nos dentes. As técnicas disponíveis atualmente incluem o clareamento realizado em consultório, o clareamento caseiro e a associação de ambas. Este trabalho descreve casos clínicos realizados com a associação destas técnicas e empregando diferentes concentrações de agentes clareadores para obter resultados rápidos e satisfatórios.


Dental bleaching offers a conservative, simplified and economical approach to change the color of teeth. Current bleaching techniques include a dentist-prescribed in-office technique, an at-home applied technique or a combination of both. This paper describes clinical cases performed with the association of these techniques with different bleaching agents to obtain faster and satisfactory and results.


Тема - темы
Humans , Male , Female , Adult , Color , Tooth Bleaching , Esthetics, Dental
8.
Rev. ABO nac ; 13(5): 282-286, out.-nov. 2005. tab
Статья в португальский | LILACS, BBO | ID: lil-445035

Реферат

O objetivo deste estudo foi comparar a resistência de união em dentina de quatro sistemas adesivos de frasco único e dois autocondicionantes. Noventa fragmentos obtidos da porção coronária de dentes bovinos foram incluídos em resina de poliestireno e desgastados com lixas abrasivas até se obter uma superfície plana em dentina. Em seguida, os espécimes foram divididos aleatoriamente em seis grupos (n=15), de acordo com o sistema adesivo: [SB]Single Bond; [PB]Prime & Bond NT; [EX]Excite; [OCB]One Coat Bond; [CLF]Clearfil SE Bond e [OUB]One-Up Bond F. Sobre cada superfície dentinária foi aplicado o sistema adesivo e confeccionado um cilindro de resina composta Z250, utilizando-se uma matriz de teflon bipartida. Após 7 dias, o teste de cisalhamento foi realizado em uma máquina de ensaio universal (EMIC) com velocidade de O,5mm/min. Os dados obtidos em MPa foram submetidos à análise estatística (ANOV A e Tukey, p

Тема - темы
Animals , Cattle , Dentin , Dentin-Bonding Agents
9.
Ciênc. odontol. bras ; 8(2): 19-24, abr.-jun. 2005. tab
Статья в английский | LILACS, BBO | ID: lil-428135

Реферат

The aim of this study was to evaluate the microleakage of class II resin composite restorations polymerized with light-emitting diodes (LEDs) with different numbers of blue diodes. One hundred sixty-eight class II cavities were prepared in bovine teeth. A one-bottle adhesive system (Single Bond/3M ESPE) was applied. The microhybrid or packable resin composites were inserted in three horizontal increments and cured for 40 seconds each, according to the following groups (n=21): G1- Z250 + LED light curing unit with 19 LEDs (3M ESPE); G2- Surefil + LED light curing unit with 19 LEDs; G3- Z250 + LED light curing unit with 7 LEDs (DMC); G4- Surefil + LED light curing unit with 7 LEDs; G5- Z250 + LED light curing unit with 6 LEDs (MM Optics); G6- Surefil + LED light curing unit with 6 LEDs; G7- Z250 + conventional halogen light curing unit (Demetron-Kerr); G8- Surefil + conventional halogen light curing unit. After thermocycling, the specimens were immersed in 2% methylene blue solution and then evaluated for microleakage. The Kruskal-Wallis and non-parametric Multiple Comparison tests (p<0.05) showed statistically significant differences among groups median: G1: 1(d); G2: 4(a); G3: 1(cd); G4: 4(a); G5: 2(bc); G6: 4(a); G7: 1(cd); G8: 4(ab). The blue light-emitting diode units (LEDs) demonstrated similar results to the conventional halogen lamp unit and the microleakage of the packable resin composite was significantly more severe than that of the microhybrid resin composite


Тема - темы
Cattle , Composite Resins , Dental Leakage , In Vitro Techniques , Inlays , Light
10.
Rev. ABO nac ; 13(2): 81-85, abr.-maio 2005. ilus
Статья в португальский | LILACS, BBO | ID: biblio-872687

Реферат

Para realização de qualquer procedimento estético, deve-se considerar o conceito subjetivo e variável, respeitando-se certos princípios básicos. O objetivo deste estudo é levar informações mais detalhadas sobre esses princípios gerais e específicos da estética aplicados à Odontologia, ressaltando a importância da forma, tamanho, proporção, cor e textura dos dentes e sua relação direta com a simetria para obtenção de faces e sorrisos mais harmônicos...


Тема - темы
Esthetics, Dental , Mouth Rehabilitation , Oral Health , Smiling
11.
Braz. dent. j ; Braz. dent. j;15(3): 194-198, Sept.-Dec. 2004. tab, graf
Статья в английский | LILACS | ID: lil-431292

Реферат

O objetivo deste estudo foi avaliar a eficácia de 3 sistemas adesivos hidrófilos na redução da microinfiltração de restaurações classe II. Foram selecionados 60 dentes molares humanos. Foi realizado em cada dente dois preparos classe II do tipo "slot vertical" nas superfícies mesial e distal, com margem cervical em dentina. As 120 cavidades foram sorteadas aleatoriamente em 3 grupos (n = 40), de acordo com o sistema adesivo testado G1: OptiBondo SOLO® (Kerr); G2: Amalgambond Plus® (Parkell); G3: Etch & Prime 3.0® (Degussa). As cavidades foram restauradas com resina composta Z 100 (3M/ESPE). As amostras foram termocicladas 2000 vezes (5 ± 1ºC e 55 ± 1ºC), durante 1 min em cada banho. Após a termociclagem, os dentes foram imersos em uma solução de azul de metileno a 2%, pH 7,0, durante 4 h, seccionados e observados em microscópio ótico MEIJI 2000 (35X). A avaliação foi realizada utilizando-se escores (0-4) e os resultados expressos através da soma das ordens. G1: 1994.00; G2: 2294.00; G3: 2972.00. Os 3 grupos foram significativamente diferentes. Os resultados indicaram que o sistema adesivo auto-condiconante Etch & Prime 3.0 foi menos efetivo no controle da microinfiltração marginal. Já o sistema adesivo OptiBond SOLO foi o mais efetivo no controle da microinfiltração quando comparado com o Amalgambond Plus e o Etch & Prime 3.0.


Тема - темы
Humans , Dentin-Bonding Agents , Molar , Malocclusion, Angle Class II , In Vitro Techniques , Dental Leakage/prevention & control , Dental Restoration, Permanent/methods
12.
Braz. oral res ; 18(2): 162-167, Apr.-Jun. 2004. tab
Статья в английский | LILACS | ID: lil-363268

Реферат

Este estudo in vitro avaliou a resistência ao cisalhamento da dentina submetida ao tratamento com dois agentes clareadores contendo peróxido de carbamida a 10% depois de 15 dias de clareamento e armazenagem em saliva artificial. Fragmentos de dentina foram aleatoriamente distribuídos em 3 grupos (n = 20) para receber o tratamento com dois diferentes agentes clareadores (Rembrandt a 10% ou Opalescence a 10%) ou com um agente placebo, aplicados na superfície dental por 8 horas diárias. No restante do tempo, os espécimens permaneceram imersos em saliva artificial. Após o tratamento por 42 dias, os fragmentos foram armazenados em saliva artificial por 14 dias. Outro grupo (n = 20) somente recebeu a aplicação de água destilada e deionizada por 56 dias. Um sistema adesivo e uma resina composta microhíbrida foram utilizados para o preparo dos corpos-de-prova para o teste de cisalhamento. Após os ensaios, a superfície foi examinada visualmente com um estereoscópio com aumento de 30 X. A análise de variância (ANOVA) e o teste SIDAK mostraram que a dentina tratada com Opalescence a 10% apresentou maiores valores de resistência ao cisalhamento do que a tratada com o Rembrandt a 10% ou com o agente placebo. Os grupos tratados com Rembrandt a 10%, Opalescence a 10% ou agente placebo não diferiram do grupo que recebeu somente o tratamento com água destilada e deionizada. Agentes clareadores contendo peróxido de carbamida a 10% ou um agente placebo não alteraram a resistência ao cisalhamento da dentina após 15 dias de imersão em saliva artificial.


Тема - темы
Dentin/drug effects , In Vitro Techniques , Oxidants/pharmacology , Peroxides/pharmacology , Shear Strength , Tooth Bleaching/adverse effects , Analysis of Variance , Compressive Strength , Drug Combinations , Placebos , Saliva, Artificial
13.
Rev. bras. odontol ; 61(3/4): 203-206, 2004. mapas
Статья в португальский | LILACS, BBO | ID: lil-412350

Реферат

Este trabalho tem como objetivo apresentar dois casos clínicos onde a seleção inadequada de pinos intracanal pré-fabricados provocou fratura longitudinal em incisivos laterais, gerando abscessos periodontais e perda dental. Os pinos selecionados possuíam diâmetros exagerados, o que gerou a fratura por esforço mastigatório. Parâmetros clínicos são discutidos de modo a facilitar a seleção de pinos intracanal pré-fabricados, evitando possíveis danos iatrogênicos que ocasionam o colapso periodontal e de todo o tratamento


Тема - темы
Humans , Female , Aged , Periodontal Abscess/etiology , Tooth Fractures/etiology , Post and Core Technique , Tooth Loss/etiology , Incisor , Tooth, Nonvital
14.
Ciênc. odontol. bras ; 6(2): 80-87, abr.-jun. 2003. ilus
Статья в португальский | LILACS, BBO | ID: lil-385908

Реферат

Esse trabalho teve como objetivo avaliar a resistência adesiva entre uma cerâmica hidrotérmica (Symbio ceram, Degussa), silanizada ou não e aderida à uma resina composta (Filtec Z100-3M ESPE) por um cimento resinoso (Panavia F, Kuraray). Foram confeccionados 2 blocos, divididos em 2 grupos assim constituídos: Grupo I-tratamento de superfície da cerâmica com ácido fluorídrico a 10 por cento, aplicação de Silano (Dentisply) e união a um substrato (resina composta) com cimento resinoso. Os blocos foram armazenados em água destilada por 7 dias a 37ºC. Em seguida, foram cortados de forma a obter, para cada grupo, 10 corpos-de-prova com dimensões aproximadas de 10mmx1mmx1mm e área de avaliação de 1mm2+/- 0,1mm2, os quais foram tracionados em máquina de ensaios universal (EMIC) na velocidade de 0,5mm.min-1. Os valores médios (MPa) foram submetidos aos testes estatísticos T test (paramétrico) e U-Mann-Whitney (não paramétrico), mostrando que o Grupo I (média 15,09+/-3,97 e mediana 16,63) diferiu estatisticamente do Grupo II (média 27,06+/-10,59 e mediana 26,370) (t=3,78; gl=18; p-valor= 0,004). Em função da metodologia empregada e dos resultados obtidos conclui-se que a aplicação de silano aumentou a resistência adesiva do cimento resinoso à cerâmica.


Тема - темы
Ceramics , Resin Cements , Silanes
15.
Rev. ABO nac ; 11(1): 23-27, fev.-mar. 2003. ilus, tab
Статья в португальский | LILACS, BBO | ID: lil-351795

Реферат

Os primeiros adesivos dentinários hidrófilos caracterizavam-se pela aplicaçäo separada do primer e do bond na tentativa de reduzir o número de frascos do sistema e simplificar etapas na técnica restauradora. O objetivo deste estudo foi comparar a resistência ao cisalhamento dos adesivos convencionais e de frasco único. Foram utilizados os sistemas adesivos Scotchbond MP Plus (SB) e All Bond 2 (AB), e os adesivos de frasco único One Step (OS) e Prime & Bond 2.0 (PB). As superfícies dentinárias foram obtidas de pré-molares humanos extraídos. As médias de resistência ao cisalhamento, em MPa, foram: SB- 22,99 ñ 9,39; AB- 22,26 ñ 7,23; OS- 21,62 ñ 6,04 e PB- 23,43 ñ 9,05. A ANOVA indicou nenhuma diferença significativa na resistência de uniäo entre os adesivos (p > 0,05). Os resultados sugerem que sistemas adesivos convencionais e de frasco único apresentam similares médias de resistência ao cisalhamento


Тема - темы
Humans , Male , Female , Dentin , Dentin-Bonding Agents
16.
RGO (Porto Alegre) ; 51(1): 23-29, jan.-mar. 2003.
Статья в португальский | LILACS, BBO | ID: lil-365822

Реферат

Atualmente, um dos aspectos mais estimados no conjunto estético da face é o sorriso. Este fato estimulou o desenvolvimento de técnicas e materiais que proporcionem um resultado mais harmonioso, que satisfaça os anseios do paciente. Antigament, dentes que apresentavam anomalias de cor recebiam desgastes para, em seguida, serem reconstruídos através de procedimentos diretos ou indiretos. Hoje, o profissional pode contar com técnicas altamente eficazes e seguras que possibilitam a reversão destes quadros de alteração de cor. O clareamento é a tentativa mais conservadora de restabelecer a cor normal dos dentes, através da descoloraçã das manchas dentais por processos de oxidação ou redução. Sendo assim, o objetivo deste trabalho é elucidar, através de uma revisão de literatura, as principais técnicas e procedimentos necessários para o clareamento de dentes não vitais.


Тема - темы
Humans , Male , Female , Tooth Bleaching , Tooth, Nonvital
17.
Ciênc. odontol. bras ; 6(1): 60-66, jan.-mar. 2003. ilus, tab
Статья в португальский | LILACS, BBO | ID: lil-407295

Реферат

A proposta deste estudo foi investigar, in vitro, a microinfiltração marginal em restaurações classe II realizadas com três sistemas adesivos. Setenta e cinco cavidades classe II, do tipo slot vertical foram preparadas em dentes bovinos, com margem gengival localizada 1,0 mm além da junção esmalte/cemento. Em seguida, foram numeradas e divididas aleatoriamente em três grupos de acordo com o sistema adesivo utilizado: Grupo SBMP - Sistema adesivo múltiplos frascos, Scotchbond Multi Uso; Grupo PB2.1 - Sistema adesivo frasco único, Primer & Bond 2.1; Grupo CLB2V - Sistema adesivo "autocondicionante", Clearfil Liner Bond 2V. As cavidades foram restauradas com resina composta em três incrementos horizontais. Após polimento, os dentes foram submetidos a 1000 ciclos térmicos em água destilada em banhos de 5°C ñ 2°C e 55°C ñ 2°C. Após impermeabilização com esmalte cosmético, os dentes foram imersos em azul de metileno a 2 por cento tamponado por 4 horas. Logo depois, foram seccionados no centro das restaurações e analisadas quanto ao grau de infiltração em lupa estereoscópica com 50vezes de aumento. Os dados foram submetidos ao teste de Kruskal Wallis (p>0,05) e expressos através da soma das ordens: Grupo SBMP - 936,50; Grupo PB2.1 - 1053,00; Grupo CLB2V - 860,50. Embora Clearfil Liner Bond 2V tenha apresentado menores índices de microinfiltração, não houve diferença estatisticamente significante entre os grupos (a=0,4531). Concluiu-se que os três sistemas adesivos estudados não foram capazes de impedir a microinfiltração na margem gengival de restaurações classe II de resina composta, e o adesivo "autocondicionante" comportou-se da mesma forma que os adesivos que utilizam o ácido fosfórico como agente condicionador


Тема - темы
Dental Leakage , Dentin-Bonding Agents
18.
Ciênc. odontol. bras ; 5(3): 62-69, set.-dez. 2002. ilus, tab
Статья в португальский | LILACS, BBO | ID: lil-407981

Реферат

O objetivo deste trabalho foi avaliar a influência da técnica de inserção da resina composta condensável sobre a microinfiltração marginal. Foram preparadas 120 cavidades classe II em dentes bovinos, com margem gengival em dentina/cemento, que foram divididas em quatro grupos: G1 - inserção única; G2 - inserção em incrementos horizontais; G3 - inserção em incrementos oblíquos; G4 - inserção mista em incrementos vestíbulo-linguais. Todas as cavidades foram restauradas utilizando o sistema adesivo Prime & Bond 2.1 (Dentsply) e a resina composta Surefil (Dentsply). Os dentes foram submetidos à termociclagem (5+/- 2 C e 55+/-2 C, durante 1000 ciclos) e, em seguida, imersos em solução aquosa de azul de metileno a 2 por cento pH 7, por 4 horas. A avaliação da microinfiltração marginal foi realizada por dois examinadores, segundo o critério de escores de 0 a 4. As médias de microinfiltração para cada grupo foram: G1 = 3,0; G2 = 3,3; G3 = 2,6; G4 = 3,3; e o teste Kruskal-Wallis demonstrou não haver diferença estatisticamente significante na microinfiltração entre as diferentes técnicas ao nível de significância de 5 por cento. Nenhuma das técnicas de inserção foi capaz de eliminar a microinfiltração e não diferiram entre si


Тема - темы
Composite Resins/administration & dosage
19.
Rev. ABO nac ; 10(5): 292-6, out.-nov. 2002. ilus, tab
Статья в португальский | LILACS, BBO | ID: biblio-872374

Реферат

A detecção de leões cariosas dentinárias encobertas por um esmalte dental hígido exige um diagnóstico clínico mais minucioso. Esta lesão denominada "cárie oculta" é capaz de promover extensa destruição dentinária e, nesta fase, o tratamento é restaurador. Fatores etiológicos bem como métodos preventivos vêm sendo estudados, no entanto, o uso de uma criteriosa inspeção visual aliada às tomadas radiográficas interproximais, é essencial para seu diagnóstico


Тема - темы
Clinical Diagnosis , Dental Caries
20.
Rev. bras. odontol ; 59(5): 307-309, set.-out. 2002. ilus
Статья в португальский | LILACS, BBO | ID: lil-331280

Реферат

A existência de alteraçöes nos dentes anteriores causadas por lesöes de cárie, má formaçäo, traumatismos, alteraçöes de cor, mau posicioamento no arco dental e restauraçöes deficientes, normalmente geram um prejuízo estético significativo no paciente. Para o estabelecimento da harmonia do sorriso, o profissional pode lançar mäo de técnicas de clareamento dental vital e não vital aliadas ao avanço de sistemas adesivos e resinas compostas, que se constituem em uma opçäo menos invasiva, proporcionando alteraçöes significativas com ótimo resultado estético. Este trabalho visa descrever a associaçäo de técnicas de clareamento dental com condutas restauradoras diretas para pacientes insatisfeitos com seu sorriso


Тема - темы
Humans , Male , Composite Resins , Esthetics, Dental , Dental Restoration, Permanent/methods , Tooth Bleaching
Критерии поиска