Your browser doesn't support javascript.
loading
Шоу: 20 | 50 | 100
Результаты 1 - 2 de 2
Фильтр
Добавить фильтры








Годовой диапазон
1.
Zhonghua xinxueguanbing zazhi ; (12): 490-496, 2023.
Статья в Китайский | WPRIM | ID: wpr-984680

Реферат

Objective: To explore the safety and efficacy of excimer laser coronary angioplasty (ELCA) for the treatment of degenerated great saphenous vein graft (SVG). Methods: This is a single-center, prospective, single-arm study. Patients, who were admitted to the Geriatric Cardiovascular Center of Beijing Anzhen Hospital from January 2022 to June 2022, were consecutively enrolled. Inclusion criteria were recurrent chest pain after coronary artery bypass surgery (CABG), and coronary angiography confirmed that the SVG stenosis was more than 70% but not completely occluded, and interventional treatment for SVG lesions was planned. Before balloon dilation and stent placement, ELCA was used to pretreat the lesions. Optical coherence tomography (OCT) examination was performed and postoperative index of microcirculation resistance (IMR) were assessed after stent implantation. The technique success rate and operation success rate were calculated. The technique success was defined as the successful passage of the ELCA system through the lesion. Operation success was defined as the successful placement of a stent at the lesion. The primary evaluation index of the study was IMR immediately after PCI. Secondary evaluation indexes included thrombolysis in myocardial infarction (TIMI) flow grade, corrected TIMI frame count (cTFC), minimal stent area and stent expansion measured by OCT after PCI, and procedural complications (Ⅳa myocardial infarction, no reflow, perforation). Results: A total of 19 patients aged (66.0±5.6) years were enrolled, including 18 males (94.7%). The age of SVG was 8 (6, 11) years. The length of the lesions was greater than 20 mm, and they were all SVG body lesions. The median stenosis degree was 95% (80%, 99%), and the length of the implanted stent was (41.7±16.3)mm. The operation time was 119 (101, 166) minutes, and the cumulative dose was 2 089 (1 378, 3 011)mGy. The diameter of the laser catheter was 1.4 mm, the maximum energy was 60 mJ, and the maximum frequency was 40 Hz. The technique success and the operation success rate were both 100% (19/19). The IMR after stent implantation was 29.22±5.95. The TIMI flow grade of patients after ELCA and stent implantation was significantly improved (all P>0.05), and the TIMI flow grade of all patients after stent implantation was Grade Ⅲ. The cTFC decreased significantly after ELCA (33.2±7.8) and after stent placement (22.8±7.1) than preoperative level (49.7±13.0) (both P<0.001). The minimum stent area was (5.53±1.36)mm2, and the stent expansion rate was (90.0±4.3)%. Perforation, no reflow, type Ⅳa myocardial infarction and other complications were not observed. However, postoperative high-sensitivity troponin level was significantly increased ((67.937±33.839)ng/L vs. (5.316±3.105)ng/L, P<0.001). Conclusion: ELCA is safe and effective in the treatment of SVG lesions and could improve microcirculation and ensure full expansion of stent.


Тема - темы
Male , Humans , Aged , Prospective Studies , Percutaneous Coronary Intervention , Lasers, Excimer/therapeutic use , Saphenous Vein/transplantation , Constriction, Pathologic , Atherectomy, Coronary/methods , Myocardial Infarction , Coronary Angiography , Stents , Treatment Outcome
2.
Zhonghua xinxueguanbing zazhi ; (12): 866-870, 2020.
Статья в Китайский | WPRIM | ID: wpr-941191

Реферат

Objective: To explore the utility and safety of leadless intracardiac transcatheter pacing system. Methods: The study was a prospective observational study. Patients underwent Micra transcatheter pacing system in Beijing Anzhen hospital from December 2019 to January 2020 were enrolled. The baseline characteristics, platelet count, hemoglobin, anticoagulation and/or antiplatelet therapy, mean procedural time, average fluoroscopy time, number of deployment and electrical parameters (threshold, R-wave amplitude, impedance) were recorded. Ultrasonography of bilateral femoral and iliac veins was performed in all patients. Patients were followed including access site complication, adverse event and device evaluation at implant, hospital discharge, 1 and 3 months post-implant. R-wave≥5 mV, impedance between 400 and 1 500 Ω and threshold increase≤1.5 V than implant is considered a stable parameter. Femoral access site complications included hematoma, hemorrhage, pseudoaneurysm, and arteriovenous fistula. Adverse events included dislodgement, cardiac effusion/perforation and infection. Left ventricular end diastolic diameter and ejection fraction before and at 1 month after implant were reported. Results: Five patients were enrolled and pacemaker implantation was successful in all 5 patients. Patients were all males and the average age was (78.4±8.4) years. 2 patients received aspirin and clopidogrel therapy, 1 patient suffered from anemia and thrombocytopenia occurred in 1 patient. No stenosis, occlusion and vascular malformation of bilateral femoral and iliac veins was observed. The mean implant time was (39.6±1.7) minutes. The average fluoroscopy time was (9.2±1.3) minutes and the number of deployment was (1.40±0.55). Electrical parameters(threshold, R-Wave amplitude and impedance) were as follows: (0.40±0.10) V/0.24 ms, (10.80±3.72) mV and (822.00±162.23) Ω at implant; (0.45±0.07) V/0.24 ms, (13.04±2.41) mV, and (748.0±91.5) Ω at discharge, (0.40±0.06) V/0.24 ms, (14.26±4.11) mV, and (700.0±91.7) Ω at 1 month post-implant and (0.39±0.05) V/0.24 ms, 14.40±3.97 mV, and (682.0±96.0) Ω at 3 months post-implant, respectively. Threshold increase was ≤1.5 V compared to that during implantation, electrical parameters were acceptable and stable. There was no difference in LVEDD [(44.00±5.24) mm vs. (44.00±5.34) mm,P=1.000] and EF [(62.00±3.39)% vs. (62.20±3.56)%, P=0.861] before and 1 month post-implant. No incidence of access site complications, cardiac effusion/perforation, dislodgment or infections occurred during the 3 months. Conclusions: The leadless transcatheter pacemaker implantation performed in our study archived a high implant success rate and favorable safety profile as well as associated with low and stable pacing thresholds. The long-term safety and benefit of leadless pacemaker need to be evaluated in future clinical studies.


Тема - темы
Aged , Aged, 80 and over , Humans , Male , Equipment Design , Follow-Up Studies , Pacemaker, Artificial , Prospective Studies , Treatment Outcome
Критерии поиска