文章 在 中文 | WPRIM | ID: wpr-1021329

摘要

BACKGROUND:In recent years,with the development of 3D printing,surgical surgery has become personalized and accurate.3D printed guide template technique can realize preoperative planning and intraoperative navigation,making surgery more accurate.In clinical orthopedic surgery for moderate and severe stiff scoliosis,there is still a problem that the accuracy of screw placement is not high,resulting in screw loosening and even nerve complications.There are few studies on 3D printed guide template technique to guide screw placement in surgery for severe stiff scoliosis. OBJECTIVE:To evaluate the clinical effect of the 3D printed guide template technique combined with multiple posterior derotation in the treatment of severe rigid scoliosis. METHODS:The clinical data of six patients with severe scoliosis undergoing 3D printed guide template technique of pedicle screw combined with multiple posterior derotation were retrospectively analyzed.There were 3 males and 3 females,with a mean age of(18.17±3.49)years(range,15-23 years).The changes of parameters related to lateral bending were analyzed at postoperative 2 weeks and 18 months,and the results were obtained by statistical analysis. RESULTS AND CONCLUSION:(1)The operation time was 280-540 minutes(mean 340.83±102.20 minutes).The intraoperative blood loss was 1 000-4 000 mL(mean 2 000.00±1 073.70 mL).The fixed segments were 9-14 vertebral bodies(mean 11.83±1.72),and no screw loosening occurred during the operation.(2)All patients were followed up.At postoperative 2 weeks,the anteroposterior and lateral radiography of the whole spine showed that the cobb angle,the distance between the vertical line of C7 on the coronal plane and the median line of S1,the distance between the vertical line of C7 in the sagittal plane and the posterior edge of S1,apical vertebral translation,thoracic kyphosis,and lumbar lordosis were significantly corrected.The average correction rate of the cobb angle in the main curve was 62.22%.After 18 months of follow-up,there was no significant change in all parameters compared with 2 weeks after operation;the orthopedic effect was satisfactory,and there was no infection or internal fixation fracture.(3)There was one case of delayed wound healing;scar healing appeared after dressing change treatment;no neurological complications occurred.(4)The results show that the 3D print-guide template combined with multiple posterior rod derotation technique is safe and effective in the treatment of severe rigid scoliosis,and the correction effect is satisfactory.

2.
文章 在 中文 | WPRIM | ID: wpr-484855

摘要

BACKGROUND:Knee-parameter measurements play an important role in the designing of the knee prosthesis. Currently, we have more and more research of the total knee replacement, while uni-condylar knee replacement study is few. OBJECTIVE: To obtain the parameters of the normal femoral condyles and explore its correlation with osteotomy and prosthesis design of the knee joint during uni-condylar knee replacement. METHODS: Normal knee joints of 60 cases (60 knees) were selected. We measured the parameters by using thin-section CT scan and post-processing techniques, including arc diameter of the lowest point of the femoral condyle on the coronal plane, arc diameter of the distal point of the posterior condyle of the femur on the transverse plane, arc diameter of the distal point of the posterior condyle of the femur on the sagittal plane, and arc diameter of the lowest point of the femoral condyle on the sagittal plane, and analyzed the correlation with sex and height. RESULTS AND CONCLUSION:The diameter of the arc that passes through the lowest point of femoral medial condyle in the coronal plane was (42.685±1.389) mm. The diameter of the arc that passes through the farthest point of posterior of femoral medial condyle in the cross-section was (42.732±1.440) mm. The diameter of the arc that passes through the lowest point of femoral medial condyle on the sagittal plane was (45.473±1.332) mm. The diameter of the arc that passes through the farthest point of posterior of femoral medial condyle on the sagittal plane was (42.587±1.446) mm. The results illustrate that knee condyle related parameters were positively correlated with height. Parameters in males were significantly greater than in females. The diameter of the arc that passes through the lowest point of femoral medial condyle on the sagittal plane was significantly larger than that of the farthest point of femoral posterior medial condyle on the sagittal plane (P < 0.001). There was no significant difference among the diameter of the arc that passes through the lowest point of femoral medial condyle on the coronal plane, the diameter of the arc that passes through the farthest point of posterior of femoral medial condyle on the cross-section and that of the farthest point of femoral posterior medial condyle on the sagittal plane.

3.
文章 在 中文 | WPRIM | ID: wpr-463889

摘要

Objective To obtain monoclonal antibodies ( mAbs ) against neutrophil gelatinase-associated lipocalin ( NGAL ) and a chemiluminescense immune quantification assay based one paired mAbs.Methods Six-to-eight weeks old female BALB/c mice were immunized with the purified recombinant human NGAL antigen( rhNGAL) that was produced by the Escherichia coil expression system.The spleen was fused with hybridoma for screening anti-NGAL monoclonal antibodies by indirect ELISA.Western blot was implemented to identify the reactivity with native NGAL. Results The rhNGAL antigen was found to form disulfide cross-linked dimers and present excellent immunogenicity.The reaction titer of the immune serum of NGAL immunized mice was about 106.Thirty mAbs were screened by indirect ELISA, hereinto;the EC50 values of mAb23C12 and 38D10 were 0.034 g/mL, 0.022 g/mL respectively.The antibodies pair, 38D10/23C12-SAE labeled with AcridiniumEster(AE), were shown to work well in chemiluminescense immune response quantitative detection which was screened by NGAL standardand clinical urine samples.This detection can resolve positive and negative samples with a statistically significant difference (P<0.0001).And the correlation coefficient R2between NGAL quantitative results and that of the Abbott's NGAL chemiluminescence immune assay kit was greater than 0.97.The detection linear range was 10-1500 ng/mL, analytical sensitivity of the method was 0.63 ng/mL.Conclusion Highly purified rhNGAL antigen and specific anti-NGAL monoclonal antibodies are generated in this study.The detection capability of method is comparable with that of the international commercial kit.

搜索明细