Your browser doesn't support javascript.
loading
節目: 20 | 50 | 100
结果 1 - 5 de 5
过滤器
添加過濾器








研究类型
年份範圍
1.
文章 在 中文 | WPRIM | ID: wpr-1019222

摘要

Objective Evaluation of the efficacy and safety of intravenous(IV)combined with intrathecal/intraventricular injection(ITH/IVT)of polymyxin against intracranial infection with multidrug-resistant bacteria.Methods The databases,including Wanfang,VIP,Chinese Biomedical Literature,Pubmed,Embase,ScienceDirect,and Cochrane Library were searched,case-control studies on IV+ITH/IVT polymyxin against intracranial infection with multidrug-resistant bacteria by January 2023 were screen.RevMan 5.4 software was used for meta-analysis.Results A total of 9 retrospective studies were included.The fatality rate in IV+ITH/IVT polymyxin group was significantly lower than that in IV group(OR =0.19,95%CI:0.11-0.35,P<0.01).There was no significant difference in ICU hospitalization days(OR =-2.32,95%CI:-23.59-18.89,P =0.83)and adverse reaction rate(OR =0.93,95%CI:0.26-3.38,P =0.91)between IV+ITH/IVT group and IV group.Conclusion IV+ITH/IVT polymyxin in treating the intracranial infection with multidrug-resistant bacteria can significantly reduce fatality rate,and does not significantly increase adverse reactions.

2.
文章 在 中文 | WPRIM | ID: wpr-1019485

摘要

Objective:To explore the experience and learning curve of single-line suspension suction rod-assisted hybrid cavity-building thyroid surgery via the oral vestibular approach.Methods:Clinical data of 138 patients undergoing single-line suspension suction rod-assisted hybrid cavity-building thyroid surgery via oral vestibular approach from Sep. 2019 to Dec. 2021 in the Department of Thyroid and Breast Surgery of Affiliated Hospital of North Sichuan Medical College were retrospectively analyzed. The cumulative sum (CUSUM) method and best-fit curve analysis were used to compare the differences in each index such as operative time, intraoperative bleeding, number of lymph nodes cleared in the central region and postoperative related complications at various stages of the learning curve.Results:All 138 patients underwent single-line suspension rod-assisted hybrid cavity-building thyroid surgery via the oral vestibular approach, and one patient was converted to open surgery due to large intraoperative bleeding in the mass. There were 14 males and 124 females, mean age (36.07±8.49) years (20-55 years), thyroid tumor size (7.74±6.49) mm (2.4-50mm), 5 cases underwent Subtotal thyroidectomy, 129 cases underwent Unilateral lobectomy + lymph node dissection in the middle region, and 4 cases total thyroidectomy + central zone lymph node dissection. The number of surgical cases corresponding to the apex of the CUSUM learning curve was 45, and the learning curve was divided into two stages: the learning improvement stage (1-45 cases) and the mastery stage (46-138 cases). The operative time, intraoperative bleeding, postoperative hospital stay, and chin numbness were all lower in the proficiency period than in the learning and training period ( P<0.05), and the number of lymph nodes cleared in the central region was larger than that in the learning and improvement stage ( P<0.05), while the differences in other indexes between the two stages were not statistically significant ( P>0.05) . Conclusion:The single-line suspension suction rod-assisted hybrid cavity-building thyroid surgery via the oral vestibular approach has clinical application value and is worth promoting, and the number of surgical cases to be accumulated to master this technique is 45.

3.
Chinese Journal of Orthopaedics ; (12): 97-103, 2023.
文章 在 中文 | WPRIM | ID: wpr-993415

摘要

Objective:To investigate the effect of 3D-printed customized flanged cup in hip revision with severe acetabular bone defects.Methods:Since February 2017, 10 cases of 3D-printed customized flanged cups were used in hip revision with severe acetabular bone defects, including 2 cases of Paprosky type IIIA and 8 cases of Paprosky type IIIB. There were 5 males and 5 females, mean age 73.6±8.1 yrs (range, 62-87 yrs), 5 left and 5 right cases. The preoperative thin-layer CT scan was preformed to reverse reconstruct digital pelvis. Five cases of one-piece flanged cups and 5 cases of decomposed flanged cups, including 3 cases of composite one-piece cups were designed by computer. The surgery was performed strictly according to the plan.Postoperative follow-up was performed to evaluate the Harris score. Operation time,intraoperative bleeding and other complications such as vascular and nerve injury, postoperative infection, and dislocation were counted. Pelvic X-ray was used to assess the height and horizontal position of the center of rotation and the stability of the prosthesis.Results:The surgical procedure was successful, with an average operative time of 147.9±48.3 min (range, 96-212 min) and an average intraoperative bleeding of 730.4±262.6 ml (range, 500-1 300 ml). The mean time of final follow-up was 40.8±18.7 months (range, 16-70 months) after surgery. At the last follow-up, the average Harris score was 83.80±6.73, with 4 cases excellent, 5 cases good, and 1 case fair. The excellent and good rate was 90%. The last Harris score was significantly higher than that before operation 28.60±8.40 ( t=16.84, P<0.001). The height of affected hip joint rotation center decreased from 46.24±7.74 mm before operation to 15.54±2.54 mm after operation with significant difference ( t=14.61, P<0.001). It was slightly higher than the opposite side (13.81±1.48 mm), which had no significant difference ( t=1.83, P=0.100). The horizontal distance of affected hip joint rotation center increased from 33.79±5.27 mm before operation to 40.53±4.50 mm after operation with significant difference ( t=3.62, P=0.006). It had no significant difference ( t=1.28, P=0.232) compared with the opposite side (38.54±3.46 mm). All incisions were healed in one stage without infection, vascular or nerve injury. During the following-up, all prostheses were in satisfied position without loosening, dislocation or screw breaks. Conclusion:Digitally assisted 3D-printed flanged cups can be used in hip revision with severe acetabular bone defect. It can not only improve hip joint function, but also restore the acetabular rotation center and the prosthesis stability, which can achieve good early and mid-term effect.

4.
文章 在 中文 | WPRIM | ID: wpr-1025553

摘要

Objective:To revise the family resilience assessment scale (FRAS) in patients with stroke and to evaluate its psychometric properties and applicability.Methods:FRAS was authorized and translated into Chinese.The scale items were revised based on the interview results of 13 patients with stroke and 11 caregivers and the opinions of 20 experts in related fields.A convenience sampling method was used to sample neurology and neurosurgery inpatients from 2 tertiary hospitals in Hangzhou twice from June to November 2022, with 325 questionnaires (sample 1) distributed the first time for item analysis and exploratory factor analysis, and 285 questionnaires (sample 2) distributed the second time for confirmatory factor analysis, criterion validity and reliability test.Data analysis was conducted by SPSS 26.0 and AMOS 24.0.Results:The exploratory factor analysis extracted 6 common factors(family beliefs, family spirit, family connection, family resources, family communication, family collaboration) with 32 items.Confirmatory factor analysis showed that the model fit well( χ2/ df=2.67, RMSEA=0.025, CFI=0.98, GFI=0.90, IFI=0.98, RMR=0.031). The cronbach's α coefficient of the total scale was 0.96, and 0.82-0.92 for the dimensions.The 2-week retest reliability was 0.99.The total scale score was positively correlated with the validity scale (family resilience scale) ( r=0.882, P<0.001). Conclusion:The family resilience scale for patients with stroke has good reliability and validity and can be used to assess the family resilience of patients with stroke.

5.
文章 在 中文 | WPRIM | ID: wpr-327128

摘要

Edge detection is an absolutely necessary step in medical image processing, and the use of differential operators to detect edge is one of the most common and effective methods. In this paper are analyzed the frequency features of the Roberts operator, Prewitt operator, Sobel operator and Laplacian operator from the viewpoint of frequency domain, and it is proposed that the frequency features of the differential operators should be considered when differential operator is being used and/or constructed. Because edge detection operator is sensitive to the edge type, the appropriate operator should be adopted in different edge type detection. Finally, the importance and necessity of selecting edge detection operator are validated in the MRI image edge processing.


Subject(s)
Humans , Algorithms , Brain , Pathology , Image Enhancement , Methods , Image Interpretation, Computer-Assisted , Methods , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Pattern Recognition, Automated , Methods
搜索明细